Subject: BSR Uniform Mechanical Code, 2015 Edition: Appeal on Proposal #333

Similar documents
Location of Requirements Listed Category I appliances Type B gas vent 12.7 Listed appliances equipped with. Chimney Single wall metal pipe 12.

ASC Z223 SECOND PUBLIC REVIEW DRAFT

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

2018 National Fuel Gas Code Summary List of Revisions Updated: 7/27/17

FACT SHEET 2018 National Fuel Gas Code Summary List of Revisions rev

MEMORANDUM. Technical Committee on Mercantile and Business Occupancies. NFPA 101 Second Draft Technical Committee FINAL Ballot Results (A2017)

Public Input No. 1-NFPA [ Global Input ] Additional Proposed Changes. Statement of Problem and Substantiation for Public Input

2015 National Fuel Gas Code Summary List of Revisions Updated: 04/24/14

Second Revision No. 5-NFPA [ Section No ] Supplemental Information. Submitter Information Verification. Committee Statement

Public Input No. 16-NFPA [ Section No ] Additional Proposed Changes. Statement of Problem and Substantiation for Public Input

CSST Installation Requirements in the Fuel Gas Codes

First Revision No. 49-NFPA 17A-2015 [ Detail ] Submitter Information Verification. Committee Statement 7/30/2015 1:35 PM

M E M O R A N D U M. NFPA Technical Committee on Building Services and Fire Protection Equipment

IFGC-2012 AMENDED IFGC-2015 IFGC-2018 CHAPTER 1 SCOPE AND

Circulation Report for SIG-TMS Comments Document # 72

NFPA 37 Public Comment Responses Page 1 of 32

Public Comment No. 23-NFPA [ Section No ] Statement of Problem and Substantiation for Public Comment Related Item

NFPA 54 UPDATE. Paul Cabot American Gas Association

Analysis of Changes for the 5 th Edition (2014) of the Florida Codes

SECTION REGULATORY REQUIREMENTS. A. Relationship between Code, Ordinances, Standards and Contract Documents

26 of 128 9/23/2014 9:25 AM

Information on IAPMO Codes and Standards Development

First Revision No. 2-NFPA [ Global Input ] Submitter Information Verification. Committee Statement. 1 of 11 1/18/2016 5:43 PM

The following preprint is based on the First Revision Draft of the 2018 edition of NFPA 54/Z223.1.

M E M O R A N D U M. NFPA 5000 A2011 ROP Letter Ballot

First Revision No. 82-NFPA [ Detail ] Submitter Information Verification Submitter Full Name: Organization:

Public Input No. 1-NFPA 90B-2015 [ Chapter 2 ]

First Revision No. 20-NFPA [ Section No ]

Public Safety [661] Chapter 226, Liquefied Petroleum Gas, Amended for Application within the State of Iowa

NFPA Talking Points on NFPA 1 Fire Code update to the 2015 Edition:

ARTICLE 25. FUEL GAS CODE

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

Changes for the New Edition. Senior Engineer, NFPA NFPA

U.S. Codes & Standards for Energy Storage Systems. Joe Cain, P.E. Chair, SEIA Codes & Standards Working Group

The Current (2017) State of the Art for Air Leakage in Ductwork

Uniform Mechanical Code

MEMORANDUM. NFPA Technical Committee on Fire Code (FCC-AAA) Subject: NFPA 1 Proposed Tentative Interim Amendment (TIA) No.1045

Errata ANSI Z223.1 National Fuel Gas Code 2015 Edition

2012 ICC Code Development Hearings 2012 Code Development Cycle:

Navigating The Product Certification Maze: Building Codes and Product Standards. AGENDA be Covered

A NATIONAL SET OF HYDROGEN CODES AND STANDARDS FOR THE US

Adobe Connect - Invitation to NFPA 385 Second Draft Web Conference

Update all extract references to NFPA documents (including NFPA 72) in Chapter 3 and related annex material to the latest editions.

ICC Update - Laboratory Issues Code Changes / Proposals / Trends of Interest 10/2005

Compliance Guidance for non-technical managers

SECTION (15486) - FUEL-FIRED, DOMESTIC WATER HEATERS

Second Revision No. 3-NFPA [ Section No. 2.3 ]

Gas Equipment. Volume 4 June/July Issue date: June 25, 2008

Throughout standard remove references to the following and replace with the following:

1 of /3/ :03 PM. Public Input No. 1-NFPA 13D-2015 [ Chapter 2 ]

Committee Input No NFPA [ Global Input ] Submitter Information Verification. Committee Statement. 1 of /20/ :02 AM

DEPARTMENT OF PUBLIC SAFETY DIVISION OF FIRE PREVENTION AND CONTROL

Committee on 51A M E M O R A N D U M. NFPA Technical Committee on Industrial and Medical Gases

Pismo Beach, CA Municipal Code. Chapter 8.08 FIRE PREVENTION REGULATIONS

Standards and Safety Update

NEW YORK CITY FIRE DEPARTMENT. Notice of Public Hearing and Opportunity to Comment on Proposed Rule

SECTION GENERAL-SERVICE COMPRESSED-AIR SYSTEMS

CUMULATIVE ANALYSIS OF UNIFORM MECHANICAL CODE CHANGES to 2003

Remove the "Exception" text to be consistent with direction provided in the MOS.

DRAFT MEETING MINUTES PENDING APPROVAL AT NEXT NFPA/ASC Z223 MEETING

Riverside County Fire Department Office of the Fire Marshal Market St., Ste. 150, Riverside, CA Ph. (951) Fax (951)

CAN/ULC S Integrated Systems Testing of Fire Protection and Life Safety Systems and Fire Protection Commissioning

Second Revision No. 1-NFPA 17A-2016 [ Section No ] Submitter Information Verification. Committee Statement. 1 of 14 6/22/2016 3:15 PM

Page 1 of 5 1/29/2016 4:08 PM. First Correlating Revision No. 3-NFPA [ Section No ] Submitter Information Verification


National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

MEMORANDUM. Subject: NFPA 1124 Proposed Tentative Interim Amendment (TIA) No. 1094

MEMORANDUM. NFPA Technical Committee on Fundamentals of Fire Alarm and Signaling Systems (SIG- FUN)

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

BECS COMMITTEE POSITIONS ICC 2015 Public Hearings Memphis, TN April 19-28, 2015

National Fire Protection Association M E M O R A N D U M. Technical Committee on Testing and Maintenance of Fire Alarm and Signaling Systems

1 Batterymarch Park, Quincy, MA Phone: Fax: M E M O R A N D U M

INTERNATIONAL FIRE CODE

Resolution: FR-2-NFPA Statement: The new language requires the action completed by NFPA 557 be prepared by a person that is approved.

CAN/ULC-S INTEGRATED SYSTEMS TESTING OF FIRE PROTECTION AND LIFE SAFETY SYSTEMS

Engineering Specifications

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

Agenda Item 4. European Union Mixed Competence Member States Vote. Original text Proposed text Reason for the change / inclusion

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

U.S. Department of Energy Washington, DC

TECHNICAL COMMITTEE ON SAFETY AT MOTORSPORTS VENUES. NFPA 610 First Draft Meeting. October 17-18, 2016

Gas Equipment. Volume 3 April Issue date: April 29, 2009

Public Comment No. 7-NFPA 30A-2013 [ Section No ]

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

The distances in shall be reduced to 130 ft (39.7 m) when manual dry standpipes are installed in open parking garages.

2006/2007 INTERNATIONAL FUEL GAS CODE DEVELOPMENT COMMITTEE

Re: AHRI Comments on Proposed Addendum be to ASHRAE Standard 189.1

Second Revision No. 104-NFPA [ Section No ] Submitter Information Verification. Committee Statement

NFPA Fire Inspector I Study Guide



Transition to a New Hazard Based Safety Standard, IEC

2015 IRC Significant Changes For Mechanical and Fuel Gas with LSUCCC Amendments

Oklahoma. 265: Incorporated national codes and standards The following national codes and standards are incorporated by reference:

Page 1 of 6 10/19/2016 9:49 AM. Public Input No. 4-NFPA [ Section No ] Statement of Problem and Substantiation for Public Input

NFPA 2001: Standard for Clean Agent Fire Extinguishing Systems NFPA 70: National Electrical Code (NEC) NFPA 72: National Fire Alarm Code

Pre-First Draft Meeting Technical Committee on Wastewater Treatment Plants On line/conference Call November 20, PM EDT

Item #: 1. Revise text as follows: Scope.

4/18/2017. *2012 edition of NFPA 99 has gone through a major overhaul. *This document is now a Code.

Transcription:

Paul Cabot Administrator National Fuel Gas Ms. Gabriella Davis Recording Secretary, IAPMO Standards Council International Association of Plumbing and Mechanical Officials (IAPMO) IAPMO Group World Headquarters 4755 E. Philadelphia St Ontario, CA 91761 October 3, 2014 Subject: BSR Uniform Mechanical Code, 2015 Edition: Appeal on Proposal #333 Ms. Davis, In accordance with IAPMO Regulations Governing Committee Projects, Section 1.6, I am appealing the approval of BSR Uniform Mechanical Code, 2015 Edition. In accordance with subsection 1-6.3, I am providing the following details: Appellant: Specific Items: Paul Cabot Administrator National Fuel Gas Code American Gas Association 400 N Capitol St, NW Washington, DC 20001 Committee acceptance of public comment on proposal #333 regarding Section 1308.5.10.1 [UMC ROC pages 378 see attached]. Appeal Grounds: The UMC TC accepted public comment on UMC item #333 which results in creating a conflict between the code requirements of ANSI Z223.1/NFPA 54, National Fuel Gas Code, and the UMC. The conflict between ANSI Standards violates the goal of the American National Standards Institute to promote a cohesive family of American Standards. More importantly, conflicts will impact the willingness of ANSI Standard Developer Organizations (SDOs) to provide extracts from their ANSI Standards and lessen their full participation in the UMC code development process. The participation of SDOs is crucial for ensuring that the UMC stays current on the latest life safety code requirements occurring within the various industries covered by the UMC. Without such regular updates, the UMC will be less adoptable. American Gas Association 400 N. Capitol St., NW Washington, DC 20001 202.824.7312 pcabot@aga.org

Relief Requested: Two areas of relief: Publication of the 2015 UMC with Section 1308.5.10.1 as shown in Proposal #333 not modified by the public comment. Revision of the IAPMO Operating Procedures to provide protection of extracted materials provided by ANSI SDOs to ensure that the neither the committee nor the membership can alter such material. Please let me know if an appeal hearing will be necessary or if you need any additional clarification from me. Regards, Paul Cabot Administrator National Fuel Gas Code Attachment: UMC ROC page 378

1312.4 Appliance Shutoff Valves and Connections. Appliances connected to a piping system shall have an accessible, approved manual shutoff valve with a nondisplaceable valve member, or a listed gas convenience outlet. Appliance shutoff valves and convenience outlets shall serve a single appliance and shall be installed within 6 feet (1829 mm) of the appliance it serves. Where a connector is used, the valve shall be installed upstream of the connector. A union or flanged connection shall be provided downstream from this the valve to permit removal of appliance controls. Shutoff valves serving decorative gas appliances shall be permitted to be installed in fireplaces where listed for such use. [NFPA 54:9.6.4, 9.6.4.1] (remaining text unchanged) 1312.5 Quick-Disconnect Devices. Quick-disconnect devices used to connect appliances to the building piping shall be listed to CSA Z21.41. Where installed indoors, an approved manual shutoff valve with a nondisplaceable valve member shall be installed upstream of the quick-disconnect device. [NFPA 54:9.6.5] 1314.0 Safety Shutoff Devices for Unlisted LP-Gas Appliance Used Indoors. 1314.1 General. Unlisted gas utilization appliances for use with undiluted liquefied petroleum gases and installed indoors, except attended laboratory equipment, shall be equipped with safety shutoff devices of the complete shutoff type. [NFPA 54:9.1.4] 1316.4 New Branches. Where new branches are installed from the point of delivery to new appliances, the newly installed branches shall be required to be pressure-tested. Connections between the new piping and the existing piping shall be tested with a noncorrosive leak-detecting fluid or approved leak-detecting methods. [NFPA 54:8.1.1.4] 1316.8.4 Designed for (less than) Operating Pressures. Where the piping system is connected to appliances, equipment, or equipment components designed for operating pressures of less than the test pressure, such appliances, equipment, or equipment components shall be isolated from the piping system by disconnecting them and capping the outlets. [NFPA 54:8.1.3.4] SUBSTANTIATION: 1. Sections 1301.3, 1308.5.3.4, 1308.5.10.1, 1308.5.10.4, 1308.5.11.3, 1308.7, 1308.7.2, 1308.7.5.1, 1308.7.5.4, 1308.8, 1310.1, 1311.1.1, 1311.1.6, 1311.1.6.1, 1311.1.7.2, 1311.5, 1311.8.1, 1311.8.1.1, 1311.10.1.1, 1311.14.4, 1312.4, 1312.5, 1314.1, 1316.4, and 1316.8.4 are being revised to correlate with NFPA 54-2012. 2. Section 1308.5.11.2 is being revised to correlate with NFPA 54-2012. The standard AWS B2.4 is being deleted as this standard is not in the extraction and does not pertain to heat-fusion or welding of joints, it pertains to the qualifications of the welder. 3. Section 1308.7.5.3 is being deleted as this information is duplicated in Section 1308.7.5.4 COMMITTEE ACTION: Accept as Submitted A PUBLIC COMMENT(S) WAS SUBMITTED FOR REVIEW AND CONSIDERATION. PUBLIC COMMENT: SUBMITTER: Curtis Dady, Viega, LLC RECOMMENDATION: Request to accept the code change proposal as modified by this public comment. 1308.5.10.1 Pipe Joints. Pipe joints shall be threaded, flanged, brazed, or welded, or made by press-connect fittings in accordance with CSA LC 4. Where nonferrous pipe is brazed, the brazing materials shall have a melting point in excess of 1000 F (538 C). Brazing alloys shall not contain more than 0.05 percent phosphorus. [NFPA 54:5.6.8.1] SUBSTANTIATION: Table 1701.1 lists CSA LC4-2007 (Press-Connect Copper and Copper Alloy Fittings for Use in Fuel Gas Distribution Systems) (Same as CSA 6.3.2). Furthermore, CSA LC4 is referenced in Section 1308.5.10.2 (Tubing Joints). The scope (Section 1.1) of CSA LC4 has been revised to include steel and stainless steel materials, as well as pipe 378

Curtis Dady Technical Manager Ms. Gabriella Davis Recording Secretary, IAPMO Standards, Council International Assoc. of Plumbing and Mechanical Officials IAPMO Group World Headquarters 4755 E. Philadelphia St. Ontario, CA 91716 October 30, 2014 Subject: BSR Uniform Mechanical Code, 2015 Edition: Appeal No. 11-15 to UMC Item #333 Submitted: Curtis Dady Viega, LLC 301 N. Main, 9 th Floor Wichita, KS 67202 Statement: Opposition to Appeal No. 11-15 Grounds: The appeal makes a good point regarding conflicts between code requirements. However we firmly believe these points listed below indicate a need and justification for modification to the otherwise extracted NFPA 54 verbiage: The vote for acceptance of this Public Comment was overwhelmingly in favor with 19 approving and only 1 vote of disapproval to the TCC correlated verbiage between the UPC Item #301and UMC Item #333. *Note that UPC Item #301includes the same verbiage for the same section of that code and UPC Item #301is not under appeal. If this appeal (11-15) is successful then the two sections will not correlate. The 2015 NFPA 54 does already include the updated version (v. 2012) of CSA LC4 in the Chapter 2 Referenced Publications section. Section 5.6.8.1 Pipe Joints has not yet been updated to match the scope of the current (2012) standard version. This is due to the timing described in the next bullet point. This inclusion of the 2012 version does give evidence that the 2018 version of NFPA 54 will be updated so that the body of the code will match the scope of the current standard version. The updated version of CSA LC4 (2012) was finally published in January of 2013. Proposals to the 2015 NFPA 54 were due by June of 2012 so this precluded making a proposal to section 5.6.8.1. SDO s have a later due date to submit updates to standards already included in the code. CSA did submit and the updated version is included. The proposed verbiage poses no risk for making a substantive change to what will happen in the next code cycle of NFPA 54. The proposed verbiage is a direct addition to the Pipe Joints Page 1

section of that which is already existing in the Tubing Joints section, i.e., or made by pressconnect fittings in accordance with CSA LC-4. Is there a precedent related to never modifying extracted language? The appeal does not mention a divergence from the past, i.e., that the existing code does not include extracted language that has been modified. We believe that the existing code does include changes to extracted language when necessary to improve the code. Most AHJ s are accepting that press-connect fittings listed to ANSI LC-4/CSA 6.32 are code compliant, but not all. It is too common across the country for contractors to be happily installing press-connect fittings for fuel gas distribution systems then switch into an adjacent AHJ where the inspector red tags the installation. Even though the product is listed to a standard that is referenced in the code, and even though there is a separate listing confirming compliance to the adopted code of that AHJ, the inspectors are sometimes confused because it is not spelled out in the section they are looking to for guidance. Best case is that the code official finally makes the connection and approves, during which time the contractor frets over the economic loss of having to redo the installation. But in some instances the code official will not relent and there is one current action that will pose a severe hardship for many if a favorable resolution is not reached. Having the codes up to date with the standards eliminates this type of conflict. Recommendation: Uphold the existing action and maintain the verbiage included in UMC Preprint section 1308.5.10.1. Regard, Curtis Dady Technical Manager, Viega, LLC Attachment: UMC ROC Item #333 *Just excerpt of relevant section UPC ROC Item #301 Page 2

Page 3