MassBioLogics Welcomes. The New England Chapter Parenteral Drug Association. March 12, 2008

Similar documents
BARRIER TECHNOLOGY RABS & ISOLATORS FOR ASEPTIC PROCESSING

VEGA SERIES ROTARY WASHING MACHINES

Micro 6. Main Features

Fedegari Aseptic Technology Integration: Case Study. Sergio Mauri, Director, Global Integrated Projects

Engineered for the world, designed for you. Cleaning, Sterilizing, Liquid and Powder Filling, and Closing Machines

Compact machine for automatic infeed, filling, and closing of injection vials.

MAR, THE RIGHT SOLUTION FOR YOUR PHARMACEUTICAL FILLING PROJECTS.

XTREMA PWD ASEPTIC POWDER FILLING & STOPPERING MACHINE

HYDRA LINEAR WASHING MACHINE

The Logistics of Filling and Freeze Drying using Multiple Isolators. The use of isolator technology to fill and lyophilize pharmaceuticals

A company for the design and manufacture of cleanroom equipment

PhEn-602. Pharmaceutical Facility Design

Isolators, RABs and Mobile Clean Rooms in Aseptic Processing. Gary Partington Walker Barrier Systems

Aseptic Barrier Systems

SMA Microbial Air Sampler System Product Guide

EOUIPNET. Pre-Owned Pharma Equipments. Macofar. Unused Macofar Dry Powder Injectable Line - 150VPM YOM 2008 / Imported in Jaunary 2009

MULTIFILL SERIES PHARMA HIGH SPEED ROTARY FILLING & CLOSING MACHINES

BLUE GALAXY DEPYROGENATION TUNNELS. Solid Dose Sol

FREEZE DRYER SMH RANGE The production freeze dryers for Pharmaceutical and Biotechnology industries

Clarification Proposal Annex 1, PDA: A Global. Cleanroom and. Association. Clean Air Devices. Hasim Solmaz Lighthouse Worldwide Solutions

Rapid transfer port technology

CBC s Inspection Findings and Possible Remedies Thereto

INDEX 45 FILTER DRYER VALVE CLEANING 46 FILTER DRYER CAKE REMOVAL 47 X-AXIS CENTRIFUGE CONTAINMENT

PASSION THAT DRIVES PERFORMANCES. WASHINGSOLUTIONS

Cleanroom Technology. Complete solutions for pharmacies.

Differences Matter: Knowing BMS and EMS Systems By: Jason Kelly

HALCO PRODUCTS COMPANY

For the sterilization of pharmaceutical products using the hot water cascade system.

Aseptic filling solutions. Sensofill FMa Combi Sensofill FMa Combi Predis FMa

GP Cage and Rack Washers

SOLUTIONS TO STATIC PROBLEMS

Adv. 8.4 Guidelines for Biosafety Cabinets Rev

Industrial and cgmp conform Cleaning Equipment

Load type and process/autoclave selection

Introducing The Reliance 200 and 250 Glassware Washing Systems.

Laboratory Line. Vertical and Bench-Top Life Science Autoclaves

Stability & Shelf Life

Animal Tissue Culture SQG 3242 Equipment and Lab design. Dr. SITI PAULIENA MOHD BOHARI

GMP compliant cleaning in the Pharmaceutical Industry. Andreas Trochsler 06. November 2012

Washing and sterilization systems Serving the pharma industry worldwide

Cleaning and sterilization solutions

SMART FILLING MACHINES

Stability Chambers & Rooms

LAB DIVISION. WASHING & DRYING cglp Process Equipment for Research and Microbiological Laboratories

PHARMACEUTICAL INDUSTRY CLEANING SYSTEMS

Safe Use of a Class II Biological Safety Cabinet

PhEn Semester Review. J. Manfredi Spring 09

Laboratory Equipment LAMINAR FLOW CABINETS ENVAIR ECO AIR H ISO CLASS 3 HORIZONTAL PRODUCT PROTECTION CABINET

Sterile filling of tubes

Guidelines for Ideal Layout for an Operating Theater Complex. Dr.R.D.Ravindran Aravind Eye Hospital Madurai

Fact Sheet. Recovery of Steam Condensate Utilizing Membrane Technology at Carlisle SynTec Inc., Greenville, Illinois

Hygiene Rotary Filler & Capper. AFRB Series Servo Driven CNC Rotary Filler and Capper

Basic System Includes:

August 3, Marshal Sterio Surgically Clean Air, Inc 3451 Lake Shore Blvd. W. Toronto, ON M8W 1N2. Dear Mr. Sterio:

LABOKLAV. Autoclaves Made in Germany

Stability Studies? Walk in Stability Chamber BUY RENT SERVICE. Thermolab is a one stop solution for all your stability requirements

Introduction to Pharmaceutical Freeze Drying

Factory & Hospital hygiene, Chap 21(7 th edition) Principles of GMP, Chap 23 (8 th edition )

SYRINGES PROCESSING OF PRE-STERILIZED SYRINGES

Glassware Washers: Cleaning Glassware and Implements Used in Compounding, Part 2. Abstract. Kate James, RPh Deborah Ruriani

COMPLETELY AUTOMATED HYDROLYSIS

Inspection Machines Ampoules, Vials, Cartridges, LVP, Pre-filled Syringes. When Inspection Needs Perfection

SECTION LABORATORY EQUIPMENT CONSTRUCTION STANDARD PART 1: GENERAL Scope of Standard

Model 800 Instruction Manual. Juiced Rite Juiced Rite, LLC 1243 Columbia Ave Unit B4 Riverside, CA 92507

STERILE FILLING. Products catalogue

Inline Cup Filler. AFIC - Series

The power of innovation. For better media preparation. Media preparators Systec MediaPrep.

Teknomar Brand Industrial Type ETO Sterilizer ETO C 1445 Data Sheet

Pharmaceutical washing systems

The right side of technology

Lyophilization Product Line Overview

Laminar Flow Cabinets eco air V

Pharmaceutical washing-systems

The valves feeding on containers by pack and place rebooting system mechanism. The pump valves feeding by vibratory bowl unit rotary and liner

Community Development and Recreation Committee

Best Practice Guidelines For Cleaning, Disinfection and Sterilization of Critical and Semi-critical Medical Devices

Cleanroom Air Showers

This policy has been adopted by UNC Health Care for its use in infection control. It is provided to you as information only. Infection Control Manual

Pharmaceutical Facility Design

cgmp, FDA and EHEG Compliant Cleaning Equipment (Pharma Grade)

WELCOME TO ROSEVILLE UNIVERSITY

Monitoring Insecticide Resistance on Planthopper Pests of Rice (Draft of procedures)

Class II Biosafety Cabinets

NUMBER: R&C-ARF-4.0 ISSUED: REV. A: REV. B: REV. C: REV. D: REV. E: 2.1. Frequency of Contact and Non-Contact Bedding Changes:

ADVANCED Series 15P1 17P2 19P2

Containment of Basket Filtration Centrifuges ABSTRACT

Prevas Disposable Dosing System. Department 3/5/2008 Interphex Robert Bosch LLC and affiliates. All rights reserved.

Sustainability in commercial laundering processes. Management Systems

SBS Design Considerations for Autoclave Sterilization

Faster UltraSafe Class II Microbiological Safety Cabinets. Protection, safety, reliability. And more.

Prevention of Fires and Dust Explosions within the Biomass Handling Process. PFI July 20, 2015

GUIDE TO INSPECTIONS OF LYOPHILIZATION OF PARENTERALS

BS En 285:2006+a2:2009 Description: Sterilization.

ESTEEM AUTOCLAVE SLIDING SINGLE DOOR:-

GUIDE TO INSPECTIONS OF LYOPHILIZATION OF PARENTERALS

IQ/OQ Protocol Installation Qualification/ Operation Qualification zz FreeZone Stoppering Tray Dryer & Bulk Tray Dryer Freeze Dry Systems

Part B - Health Facility Briefing and Planning. PLANNING Operational Models Functional Areas Functional Relationships

Thermo Scientific Heratherm Microbiological Incubators. safe. Part of Thermo Fisher Scientific

SDAPharma AUTOCLAVE CHART CHECKING & TESTS. Symonds Davies Associates. e-

3000 series. bottle filling machines rinsers-fillers-cappers

Transcription:

MassBioLogics Welcomes The New England Chapter Parenteral Drug Association March 12, 2008 1

MassBioLogics & NEPDA Welcome and thank sponsors: Althea Technologies Aramark Cleanroom Services B&V Testing, Inc BioVigilant Systems, Inc Eisai Machinery Formatech Genesis Machinery Co. Hyaluron Masy Systems Microtest Rapid Micro Biosystems Sartorius-Stedim 2

MBL MassBioLogics MBL - Medicine for Better Lives 3

Agenda - Facility Description - Equipment Description - Validation Approach - Product Characteristics - Aseptic Simulation Approach - Lessons Learned 4

Facility Layout Shipping, Receiving, Warehousing Fill and Finish Area Monoclonal Antibody Production Administration & Common Areas Laboratories 5

Facility Layout 6

Filling & Visual Inspection Equipment Support Equipment Parts Washer Lancer Autoclave Primus PMS non-viable sampler SMA viable sampler HVAC / Room Environment Process Control System ; Superior Controls Cold / Warm Rooms Utilities WFI MECO vapor compression Clean Steam MECO Clean Air Filling Line Vial Washer Penntech Depyrogenation Tunnel Bosch Filler / Stopper Bosch Capper Bosch Encoder Bosch Visual Inspection Eisai VIS-1000 Dual Semi-Automatic Machine 7

Warehouse Storage 8

Vial Washer Depyrogenation Tunnel 9

Product Line Pass-thru from Filler 10

Aseptic Filling 11

Capper 12

KIV 2D Matrix Imprinter on Seal 13

Vial Tray Loader 14

Eisai Visual Semi-Automated Visual Inspection 15

WIP Coldroom 2-5 C 16

Filling Line Commissioning & Qualification Unit FAT SAT IQ OQ PQ Vial Washer -- Depyro Tunnel Depyro Sterilization Filler / Stopper Cleaning Validation SIP Filler Capper -- 17

Project Timeline PAS July, 2007 > PAI October, 2007 > Nov. 2007 18

PRODUCT CHARACTERISTICS 19

PREVIOUS PRESENTATION: TETANUS AND DIPHTHERIA TOXOIDS ADSORBED FOR ADULT USE 10 ml molded vial, 9 ml fill volume 1888 gray natural rubber stopper Preservative containing multi-dose vial 20

NEW AND CURRENT PRESENTATION: PRESERVATIVE FREE TETANUS AND DIPHTHERIA TOXOIDS ADSORBED FOR ADULT USE 3 ml tubular vial, 0.72 ml fill volume 4588/40 rubber stopper Preservative free, single dose vial 21

Product Characteristics Aluminum Phosphate Adjuvant - Cannot be sterile filtered - Requires continuous mixing or recirculation - Challenge to clean - Requires cold storage Batch volume 200 L or 280,000 vials / batch - 16 hours of run time at maximum efficiency (IF everything goes smoothly) PLANNED FOR 2 TEN HOUR FILLING EVENTS AND A BACK UP 22

Line Characteristics No Barrier or Isolator No RABs Conventional!! However.. Rigid Workspace to Ceiling Barriers High Speed Automated Line Automated check weighing Air Changes exceed 400 per hour 23

Facility Characteristics Zone concept and cascade -areas of different class > 0.05 inches of water -areas of the same class > 0.02 inches of water Continuous monitoring of room conditions and pressures. Air changes per hour are very high room 1061 > 400 ACH Nearly 100% HEPA ceiling in the filling room Cleanable surfaces Daily, thorough cleaning with a dedicated crew Large viewing corridor 24

EM Monitoring Strategy We did not grid map; risk analysis prevailed. Continuously monitor NVPs and VPs ; including 5 um particles. In process monitoring once per shift of class 10000. Full monitoring and contact plates end of fill. Personnel monitored at each exit. Routine Montoring all areas on a weekly basis viables and non-viables 25

EM Data Fill Area Total Routine Monitoring InProcess Monitoring Alert 22 2 Action 10 0 Totals By Area Routine Monitoring InProcess Monitoring %Alert 0.19% 0.17% Grand Total %Action 11,588 0.09% 1,192 0.00% 26

Nearly Fully Automatic 27

Simulation Approach TR-22 Process Simulation Testing for Aseptically Filled Products 28

Aseptic Simulation GOAL Complete 3 fills, each one representing at least 20% of the filled lot size or at least 30,000 vials, with no evidence of microbial contamination. 29

Aseptic Simulation Challenges Easy Vial Size Vial configuration Fill volume Product flow / mixing characteristics 30

Aseptic Simulation Challenges Not So Easy Worst case filling speeds Duration of each fill or 12.5 hrs estimated Shift changes and staffing levels Routine and non routine interventions Atypical circumstances (manual check weigh) Holding times post sterilization Delivery from tank to filling line via a manifold 31

Filling Manifold 32

Aseptic Simulation Challenges Interventions Remove stabilization bar at outfeed of tunnel Remove downed vials at infeed table, conveyor, and outfeed conveyor Replenish stoppers Reference the Filler Clear jam at reject station, stopper hopper, and stopper chute Clean the balances, starwheel, and grippers Send vials to the reject station 33

Aseptic Simulation Outcome Qualification # Media Lot # # Vials Filled Date # pos TSB-180A 32,333 8-06 0 PQ-06309-1 TSB-182 TSB-183A 31,390 31,997 8-06 9-06 0 0 TSB-183B 37,704 9-06 0 PQ-06309-2 TSB-189 36,083 5-07 0 PQ-06309-3 TSB-191 38,283 1-08 0 Total 207,790 0 34

Aseptic Simulation Issues Reconciliation Personnel Monitoring Results Equipment issues 483 Observation: Stopper charging in class 10000 area 483 Response: Vestibule installation 35

Stopper Charging Issue 36

Lessons Learned (hard and agonizing) FAT & SAT should include full-shift testing Shorter runs may not sufficiently challenge the line mechanically Overall run productivity must be met at FAT and SAT Gain more run time experience before MF protocol Develop a bullet-proof method of reconciliation Investigate component charging during a run Pre-determine a checklist of all inserts and attachments to the protocol 37

Lessons Confirmed Keep intervention list updated for next media fill Document all rationales for media fill test procedures in protocol; document and mimic worst case fill scenarios Number and duration of runs Number of vials filled per run Staffing Interventions Equipment configuration 38

CONCLUSION PEOPLE ARE OUR GREATEST AND OUR STRONGEST LINK BUT. TECHNOLOGY AND DESIGN DO HELP!!! (Non-microbiologically speaking!) 39