SYSTEM FIELD CUTTABLE SERIES

Similar documents
SERIES. LINE OF LIGHT (No Pixelation) FLEXIBLE DIRECT VIEW LINE VOLTAGE 150 MAXIMUM RUN LOW VOLTAGE 32 MAXIMUM RUN OUTDOOR RATED

EFFICIENT LONG LIFE & ENERGY SERIES

SYSTEM. field cuttable. lipleds 8200 Series

SYSTEM. field cuttable LLED8000

OPTIONS. Mounting LUMEN OUTPUT FLAT. 3000K lm/ft PERFORMANCE. Lumen Maintenance SERIES SHAPE COLOR VOLTAGE LENGTH CONFIGURATION

ACCESSORIES. Mounting LUMEN OUTPUT 2400K 1 PERFORMANCE. Lumen Maintenance. Warranty SERIES SHAPE COLOR VOLTAGE LENGTH CONFIGURATION

4 LED Recessed Adjustable. Energy efficient, stylish downlighting for residential and commercial applications

OPTIONS. Mounting LUMEN OUTPUT. Flat. Round PERFORMANCE. Color Temperature. Lumen Maintenance Binning Tolerance Warranty + +

LINKABLE UNDERCABINET

Product Specifications MaxLumen MRI LED Diffused Lighting

Data Sheet Version 1.0

Lamp: K K K K K K

Lamp: K K K K K K

FLEX DC SIDE EMITTING

JBE LED2000 INDUSTRIAL SOLUTIONS FOR LED & INCANDESCENT MAINS LIGHTING FLICKER FREE TRAILING EDGE DIMMER

Product Specifications MaxLumen MRI LED Diffused Lighting

2200TD-3000TD Dim to Warm* 2700T-6500T Tunable White* *Must be ordered with D05 or DS5 Driver options; excludes 2' and 3' lengths

P5500 LED Architectural Downlighting

LIGHT CHANNEL.3 SURFACE MOUNT COMPLETE FIXTURE

PRELIMINARY 2000K PERFORMANCE. CRI Lumen Maintenance Binning Tolerance Warranty

12 inches to 120 inches

CFX2-RGB SPECIFICATIONS LUMEN DATA DESCRIPTION FEATURES. Type. Project LED FLEXIBLE LINEAR CFX2 RGB FLEXIBLE LED STRIP. Catalog No.

Running Magnet 2.0 Suspension Down High-tech LED lighting system for interior architecture

High Lux Performance White LED MR16 Lamp

Product Specifications MaxLumen MRI LED Diffused Lighting

USER MANUAL INSTALLATION GUIDE FOR: 2X2: MLFP22DS4035 MLFP22DS4041 MLFP22DS4050

Lamp: Average Lamp Life: 50,000 hours. 24VDC Power Supply (sold separately): PSB-4X96W VDC VAC input, 4x96 watt output

LED Fire Rated Downlight

Max Load. Max. Load. Red (+) Black (-) Gray Violet. Part number: CV 96 24DC. Solidrive constant voltage 0-10V dimmable LED driver

Type: Project : Luminaire characteristics: Source: Lumen maintenance: Optics: Material: Mounting: Electrical: Finish: Weight:

Performance Chart Electrical Data

12 inches to 120 inches. Applications: Indoor and Wet Location - Task lighting, under/above cabinet, cove and retail. ETL listed for wet location.

Performance Chart Electrical Data

Running Magnet 2.0 Suspension Up&Down High-tech LED lighting system for interior architecture

GL BAL GLEDAL 150W B L A Z E AISL E L IGHT SPECIFICATION SHE ET OPTICAL SPECS ELECTRICAL SPECS CERTIFICATIONS OTHER DETAILS DIMENSIONS BEAM ANGLES

INDICATOR LAMPS & LED REPLACEMENT LAMPS

LIGHT CHANNEL 45 COMPLETE FIXTURE

Energy Solutions LED Accelerator Program PRODUCT QUALIFICATION REQUIREMENTS 2015

Classix 6" 6" Round Adjustable C3

Controlling LEDs to meet. Russ MacAdam Director of Engineering Development

LIGHT CHANNEL.6 MILLWORK COMPLETE FIXTURE

FPLHB - Fidelux Premier Linear Highbay

Fino Healthcare. Asymmetric Wall Mount Indirect LED

E10 & L9 Low Wattage Light Cone Data

Etch 2' x 2' Recessed LED

LED RETROFIT SOLUTIONS

Recessed LED Wall/Slot SAE 202

Classix 6" 6" Round Adjustable C3

INSTALLATION MANUAL. ION-CUBE Series. LED Wall Washer CLASS 2 E359853

Performance Chart Electrical Data

Classix 6" 6" Round Adjustable C3M

ULTRA RT6 and RT6 Gimbal LED Recessed Downlight Kit

JLLP DESIGN AND CONSULTING

LIGHT CHANNEL TRIM 1.6

Modular & linear architectural lighting for residential and commercial environments.

*REPRESENTS 3500K/80CRI 2 FT 4 FT 6 FT 8 FT 2 FT 4 FT 6 FT 8 FT *REPRESENTS 3500K/80CRI LINEAR


Technical Application LED Pendant Light LUZ-PL W-W

Product Bulletin for Decora Rocker Slide Controls

LM Series LED Architectural Downlighting HIGH LUMEN OUTPUT RECESS / SURFACE MOUNT GREEN ENERGY EFFICIENT LIGHTING

Catalog # Project. Comments. Prepared by


CPPG ENERGY EFFICIENT CANOPY LIGHTS FOR PARKING AREAS

Performance Chart Electrical Data

Fino Healthcare. Asymmetric Wall Mount Indirect LED

DOME SERIES. Data will be subject to change without notice. COMMERCIAL 1

For more information, please visit 3-form.com or call

Ivalo Lumaris. LED Linear Lighting. High quality, even lines of illumination and guaranteed LED compatibility with 1% Lutron dimming IVALO COLLECTION

Handrail Lighting System

Murro HP. 3.5" Round Surface Canopy Wall Wash

Universal Dimmer N 528D01, 2 x 300VA, AC 230 V 5WG DB01

Technical Application Guide for UP-SHINE LED Ceiling light UP-AL W-B

LED Linear Design Highlights

Ivalo Lumaris LED Linear Lighting

Technical Application Guide for UP-SHINE LED Frameless Panel Light

Half Inch Round LED Rope Light

DRD5S & SurfaceFrame Alt/EM 18" Linear Surface Mount LED Area Light

CIRRUS CEILING WALL GRAZER WITH REMOTE POWER

FLEX. Innovative lighting engineered for seamless integration into the DESIGNFlex ceiling system by

Evoke Round Adjustable C3

DRD5S & SurfaceFrame Alt/EM Surface Mount LED Downlight

Dimmable LED Retrofit Kit

T8 Self Ballasted UL & CSA LED TUBE RETROFITS

Performance Chart Electrical Data

DHL-LP-LED Low Profile LED Linear High/Low Bay

SDL4 LED Strip Diffused Lens

Fino. Asymmetric Wall Mount Indirect LED

JEDI COMPACT IP67 INTEGRAL

BAS SDL8' LED Strip Diffused Lens

Step-Dimming and/or 0-10v Dimming Drivers Electro Galvanized Steel Welded Construction. Photocell Sensor - On/Off Stainless Steel Fasteners Standard

ENVISAGE V LED CEILING & ADA WALL THIRD EDITION JESCO LIGHTING

Versa-Pak DMX. DMX 512 Dimmer. User Manual Revision 1, August , Electronics Diversified, Inc.

DALI Product Range. Designed in Australia to be compatible for all DALI systems. gerardlighting.com.au

ITC 2000 HEATING CONTROL CABINET. Installation & Operation Manual

TOKISTAR LIGHTING INSTRUCTION MANUAL. Advantage Series. Xenon Lamp. Socket. Side View. 2.4 O.C. (60 mm) 3 O.C. (75 mm) 4 O.C. (100 mm) 6 O.C.

LED retrofits! 4 T8 Specification Guide. Retrofit your existing Fluorescent Lights in Seconds No Electrician Needed! Pure Bright

RECESSED DOWNLIGHTING

LED lighting for light industrial areas IHB series high bay LED luminaires. IHB series. High bay LED luminaires for light industrial areas

Basics Series Surface Mount LED Fixtures. Affordable and easy-to-install, 4" and 6" fixtures. It s a. Snap

HALO. 2700K nominal. 3000K nominal. RA4 LED Very Wide Flood (VWFL)

Transcription:

festlite SERIES FIELD CUTTABLE LOW CURVEABLE REPLACEABLE LED MODULES FIELD CUTTABLE SYSTEM LOW VOLTAGE 24VDC DIMMING Forward Phase (TRA) 0-10V (TRA-E) CRI >80 festlite Series is a field cuttable system designed with long life, energy efficient LEDs that result in low maintenance installations. festlite creates a warm, pleasant environment in restaurant interiors office buildings, retails and other venues.

Standard Applications and Performance Designed for indoor use, the festlite series is ideal for many applications including the amusement, recreation, and architectural industries. festlite is excellent for cove lighting, undercabinet lighting, accent lighting, and many more applications. festlite is used in: Restaurants, Casinos, Retail Stores, Shopping Malls, Hotels, Homes and many more. Polar Graph 71 53 35 18 2 1 Maximum Candela = 70.95 Located At Horizontal Angle = 0, Vertical Angle = 0 # 1 - Vertical Plane Through Horizontal Angles (0-180) (Through Max. Cd.) # 2 - Horizontal Cone Through Vertical Angle (0) (Through Max. Cd.) Chromaticity Diagram Y 0.9 Applications voltage socket base Indirect, Cove, Accent Lighting 24VDC Festoon 0.8 0.7 0.6 0.5 510 500 520 530 540 550 560 570 580 Length Built to Order viewing angle 220 watts.75w per LED 0.4 0.4264, 0.3879 590 600 MAX LAMPS 220 LEDs per Run 0.3 0.2 0.1 0 0 490 480 470 460 440 430 380 610 620 630 640 650 700 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 X LISTING CRI >80 EFFICACY DIMMING Dry Location 76 Lumens Per Watt Forward Phase (TRA) 0-10V (TRA-E) 2 festlite California Accent Lighting Inc. 800.921.CALI

festlite LED FL4000 FL4000-UC 4.00 1.17 FL4000-UCLE 1.67 FL4000-VR.87.99 1.40 1.17 0.8.87 1.18 1.0 0.8 FL4000-VRLE FL4000-X600 2.4.27 1.81 1.81 2.41 2.27 1.81 FL4000-X700 FL4000-X800 1.93 1.7 1.93 4.22 1.82 How to Order or Specify Series LED SPACING LAMP Dry or wet 2.00 DIMMING FL4000 2 O/C (3.8W) LED-2.4K Indoor 0-10V (10V) FL4000-UC (289 Lumens/ft)* LED-2.7K (DRY) Forward Phase (FP) FL4000-UCLE FL4000-VR 3 O/C (3W) (228 Lumens/ft) LED-3.0K LED-3.5K Outdoor (WET)** Leave Blank for Non-Dimming FL4000-VRLE FL4000-X600 4 O/C (2.3W) (175 Lumens/ft) LED-4.0K LED-4.5K FL4000-X700 FL4000-X800 6 O/C (1.5W) (114 Lumens/ft) LED-5.0K LED-5.7K EXAMPLE: FL400-2 -5.0K-DRY-277V * Nominal spacing 2 = 2.5 ** Only available for FL4000-X800 calilighting.com California Accent Lighting Inc. festlite 3

Accessories Mounting Clips 1.23 Mounting Clip (#FL4000-MC).36 Mounting clip applies to FL4000 product only. End Cap.18 1.47 End Cap (#FL4000-EC).40 Junction Box 1.25 2.00 Junction Box (#FL4000-JB) 1.75 Power Connector Continuous Connector.63.68 Power Connector (#FL4000-PC).81 8 Continuous Connector (#FL4000-CC) 4 festlite California Accent Lighting Inc. 800.921.CALI

DESIGN GUIDELINES Option A - Straight Runs Detail C Detail E Detail D Detail B Detail A 8 Option B - Rectangular and Radius Continuous Connector (#FL4000-CC) Detail C Detail A Detail B Detail E Detail C.81 Power Connector (#FL4000-PC) 1.75 Detail D Junction Box (#FL4000-JB).36 Detail D Detail E Mounting Clip (#FL4000-MC) Detail A Detail A.40 End Cap (#FL4000-EC) calilighting.com California Accent Lighting Inc. festlite 5

transformer Electronic: 0-10V Dimming Transformer (Indoor or Outdoor Rated) Product Code Max. Watts Input Output Input AC Current Power Factor Width (W) Height (H) Depth (D) TRA16-E TRA16-E-UNV-24VDC-10V 16 120V-277V 24VDC.2A / 277VAC or.4a / 120VAC.92 12.7 3.43 2.66 TRA25-E TRA25-E-UNV-24VDC-10V 25 120V-277V 24VDC.2A / 277VAC or.4a / 120VAC.92 12.7 3.43 2.66 TRA40-E TRA40-E-UNV-24VDC-10V 40 120V-277V 24VDC.25A / 277VAC or.6a / 120VAC.92 12.7 3.43 2.66 TRA60-E TRA60-E-UNV-24VDC-10V 60 120V-277V 24VDC.3A / 277VAC or.64a / 120VAC.92 12.7 3.43 2.66 TRA80-E TRA80-E-UNV-24VDC-10V 80 120V-277V 24VDC.4A / 277VAC or.85a / 120VAC.94 12.7 3.43 2.66 TRA90-E TRA90-E-UNV-24VDC-10V 90 120V-277V 24VDC.4A / 277VA or.85a / 120VAC.95 12.7 3.43 2.66 TRA100-E TRA100-E-UNV-24VDC-10V 100 120V-277V 24VDC.5A / 277VAC or 1.2A / 120VAC.93 15.7 4.42 2.92 TRA120-E TRA120-E-UNV-24VDC-10V 120 120V-277V 24VDC.55A / 277VAC or 1.4A / 120VAC.93 15.7 4.42 2.92 TRA150-E TRA150-E-UNV-24VDC-10V 150 120V-277V 24VDC.7A / 277VAC or 1.7A / 120VAC.92 15.7 4.42 2.92 TRA185-E TRA185-E-UNV-24VDC-10V 185 120V-277V 24VDC.8A / 277VAC or 2.1A / 120VAC.92 15.7 4.42 2.92 TRA240-E TRA240-E-UNV-24VDC-10V 240 120V-277V 24VDC 2A / 277VAC or 4A / 120VAC.95 15.7 4.42 2.92 TRA320-E TRA320-E-UNV-24VDC-10V 320 120V-277V 24VDC 1.45A / 277VAC or 3.5A / 120VAC.94 15.7 4.42 2.92 ** Class II 24VDC TRA16-E, TRA25-E, TRA40-E, TRA60-E, TRA-80E, TRA90-E Dimming Protocol (0-10V) TRA-E Compatible Dimmers Technical Requirements For Control Equipment (0-10V Protocol) The output current level of the dimmable driver is controlled by DC voltage (0-10V) applied to the control terminals (blue and white). The light output of LEDs is controlled by the amount of output current from the dimmable driver. The control device must be capable of sinking a DC current flow from the driver. The maximum amount under any condition is 500 microamps (ua) per driver. The control terminals of the dimmable driver are isolated from the power lines and are suitable for use as Class 2 wiring. Multiple drivers are desired for use with same control device, the control terminals may be connected in parallel in a bus configuration. Since the control bus is Class 2 wiring, all control devices that are connected to the power line must have proper isolation between the power line and the control terminals/bus. The control device, which intends to control more than one dimmable driver, must be capable of sinking the total current supplied to control bus by the drivers. If the control terminals/bus is shorted in any case, the current on the control terminals/bus will be 500 microamps (ua) per driver maximum. If the control terminals are opened, the voltage on the control terminals will then be 10V ± 0.5 volt. As a result, dimmable driver supplies maximum output current to LEDs under this condition. The driver is intended for use with control voltages between 0 and 10 VDC. The control equipment must not impose a voltage greater than 11 V peak maximum on the driver control terminals. 120V-277V TRAXXX-E-UNV-24VDC-10V Brown (Hot) Blue (Neutral) Transformer enclosure Red (+) Black (-) TRAXXX-E-UNV-24VDC-10V 24VDC to Lighting White (-) Blue (+) Dimmer (Supplied by others) 0-10V Line 6 festlite California Accent Lighting Inc. 800.921.CALI

transformer Magnetic: Forward Phase Dimming Transformer (Indoor or Outdoor Rated NEMA 3R) - Primary Fusing Included Product Code Max. Watts Input Output Input Current No Load-Full Load Power Factor Width (W) Height (H) Depth (D) TRA5 TRA5-120V-24VDC 5 120V 24VDC.4-1.4 Amps 0.961 1.975 6 1.43 TRA5-277V-24VDC 5 277V 24VDC 0.2-0.6 Amps 0.961 1.975 6 1.43 TRA10 TRA10-120V-24VDC 10 120V 24VDC 0.3-2.2 Amps 0.964 1.975 6 1.43 TRA10-277V-24VDC 10 277V 24VDC 0.12-0.8 Amps 0.964 1.975 6 1.43 TRA20 TRA20-120V-24VDC 20 120V 24VDC 0.3-2.6 Amps 0.979 1.975 6 1.43 TRA20-277V-24VDC 20 277V 24VDC 0.12-1.2 Amps 0.979 1.975 6 1.43 TRA35 TRA35-120V-24VDC 35 120V 24VDC 0.4-4.3 Amps 0.973 1.975 6 1.43 TRA35-277V-24VDC 35 277V 24VDC 0.15-1.8 Amps 0.973 1.975 6 1.43 TRA40 TRA40-120V-24VDC 40 120V 24VDC 0.8-5.3 Amps 0.978 1.975 6 1.43 TRA40-277V-24VDC 40 277V 24VDC 0.3-2.3 Amps 0.978 1.975 6 1.43 TRA50 TRA50-120V-24VDC 50 120V 24VDC 0.8-5.3 Amps 0.978 1.975 6 1.43 TRA50-277V-24VDC 50 277V 24VDC 0.3-2.3 Amps 0.978 1.975 6 1.43 TRA60 TRA60-120V-24VDC 60 120V 24VDC.4-1.4 Amps 0.961 3.00 7.50 2.75 TRA60-277V-24VDC 60 277V 24VDC 0.2-0.6 Amps 0.961 3.00 7.50 2.75 TRA75 TRA75-120V-24VDC 75 120V 24VDC.4-1.4 Amps 0.961 3.00 7.50 2.75 TRA75-277V-24VDC 75 277V 24VDC 0.2-0.6 Amps 0.961 3.00 7.50 2.75 TRA90 TRA90-120V-24VDC 75 120V 24VDC.4-1.4 Amps 0.961 4.1875 8 3.25 TRA90-277V-24VDC 75 277V 24VDC 0.2-0.6 Amps 0.961 4.1875 8 3.25 TRA100 TRA100-120V-24VDC 100 120V 24VDC.4-1.4 Amps 0.961 4.1875 8 3.25 TRA100-277V-24VDC 100 277V 24VDC 0.2-0.6 Amps 0.961 4.1875 8 3.25 TRA150 TRA150-120V-24VDC 150 120V 24VDC.4-1.4 Amps 0.961 4.1875 8 3.25 TRA150-277V-24VDC 150 277V 24VDC 0.2-0.6 Amps 0.961 4.1875 8 3.25 TRA200 TRA200-120V-24VDC 200 120V 24VDC.4-1.4 Amps 0.961 4.1875 8 3.25 TRA200-277V-24VDC 200 277V 24VDC 0.2-0.6 Amps 0.961 4.1875 8 3.25 TRA250 TRA250-120V-24VDC 250 120V 24VDC 0.3-2.2 Amps 0.964 4.1875 8 3.25 TRA250-277V-24VDC 250 277V 24VDC 0.12-0.8 Amps 0.964 4.1875 8 3.25 TRA300 TRA300-120V-24VDC 300 120V 24VDC 0.3-2.6 Amps 0.979 4.1875 8 3.25 TRA300-277V-24VDC 300 277V 24VDC 0.12-1.2 Amps 0.979 4.1875 8 3.25 * Class II 24VDC TRA5, TRA10, TRA20, TRA35, TRA40, TRA50, TRA60, TRA75, TRA90 Dimming Protocol (Forward Phase Dimming) TRA Compatible Dimmers Technical Requirements For Control Equipment Magnetic Low Voltage (MLV) - Magnetic (core and coil, toroidal) transformer-supplied low voltage lighting Electrical Characteristics - Inductive Special Requirements - Symmetric cycles (VDC 2), smooth turn off (positive and negative periods are equal for safe MLV transformer operation) TRAXXX-120V-24VDC TRAXXX-277V-24VDC Transformer enclosure Transformer enclosure Red (+) Red (+) Blue (-) Green (Ground) Blue (-) Green (Ground) 24VDC to Lighting 24VDC to Lighting Optional Dimmer (not included) Optional Dimmer (not included) White (Neutral) White (Neutral) Black Dimmed (Hot) Orange (277V) Primary Voltage 120VAC Line Primary Voltage 277VAC Line calilighting.com Forward Phase Dimming California Accent Lighting Inc. Forward Phase Dimming festlite 7

California Accent Lighting, Inc. 2034 E. Lincoln Ave. #431, Anaheim, CA 92806 ph. 800.921.CALI or 714.535-7900 \ fx. 714.535.7902 info@calilighting.com \ calilighting.com CALI. All rights reserved. CALI reserves the right to make changes or withdraw specifications without prior notice. 8 festlite California Accent Lighting Inc. 800.921.CALI