Heat Pump Fluidised Bed Dryer with CO 2 as Refrigerant Measurements of COP and SMER

Similar documents
Heat Pump Assisted Drying - Freeze Drying Technology

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant

International Journal of Engineering Research (IJOER) [Vol-1, Issue-3, June- 2015]

COMPACT HEAT EXCHANGERS FOR MOBILE CO 2 SYSTEMS

Experimental Investigate on the Performance of High Temperature Heat Pump Using Scroll Compressor

REFRIGERATION CYCLES

REFRIGERATION CYCLES

WORK STUDY ON LOW TEMPERATURE (CASCADE) REFRIGERATION SYSTEM

INFLUENCE OF DRYING CONDITIONS ON THE MOISTURE DIFFUSION DURING SINGLE STAGE AND TWO STAGE FLUIDIZED BED DRYING OF BOVINE INTESTINE FOR PET FOOD

SEWAGE SLUDGE THERMAL DRYING AND HYGIENIZATION IN A CLOSED LOOP ENERGY RECOVERING SYSTEM

Experimental Study on Compact Heat Pump System for Clothes Drying Using CO 2 as a Refrigerant. Abstract

4th International Conference on Sensors, Measurement and Intelligent Materials (ICSMIM 2015)

A Theoretical investigation on HC Mixtures as Possible Alternatives to R134a in Vapor Compression Refrigeration

REVERSIBLE R744 (CO 2 ) HEAT PUMPS APPLIED IN PUBLIC TRAINS

Experimental performance evaluation of heat pump by using CO 2. as a refrigerant. IOP Conference Series: Materials Science and Engineering

Carbon Dioxide based Heat Pump Dryer in Food Industry

International Journal of Research in Engineering and Innovation Vol-1, Issue-5 (2017), 68-72

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview

EFFECT OF PAG OIL CIRCULATION RATE ON THE HEAT TRANSFER PERFORMANCE OF AIR-COOLED HEAT EXCHANGER IN CARBON DIOXIDE HEAT PUMP SYSTEM

Experimental Research On Gas Injection High Temperature Heat Pump With An Economizer

Effects of Oil on atranscritical Carbon Dioxide Air Conditioning Systems some experiences -

FS 231: Final Exam (5-6-05) Part A (Closed Book): 60 points

Performance of CO2 Cycles with a Two-Stage Compressor

SIDDHARTH GROUP OF INSTITUTIONS :: PUTTUR Siddharth Nagar, Narayanavanam Road AUTONOMOUS QUESTION BANK (DESCRIPTIVE) UNIT I

Development and Performance Measurements of a Small Compressor for Transcritical CO2 Applications

Thermodynamics I. Refrigeration and Heat Pump Cycles

Thermodynamic Calculations of Two-Stage Vapor Compression Refrigeration Cycle with Flash Chamber and Separate Vapor Mixing Intercooler

A Comparison Between Refrigerants Used In Air Conditioning

A study of Transient Performance of A Cascade Heat Pump System

Exploring the Performance Characteristics of CO2 Cycles in a Breadboard-Type Test Facility

AN EXPERIMENTAL REFRIGERATOR WITH AN INVERSE AIR CYCLE FOR FREEZING IQF FOOD PRODUCTS

CO 2 AS REFRIGERANT FOR SYSTEMS IN TRANSCRITICAL OPERATION PRINCIPLES AND TECHNOLOGY

3. (a) Explain the working of a rotary screw compressor. [10] (b) How the capacity control is achieved in refrigerant compressor?

Experimental Study on Match for Indoor and Outdoor Heat Exchanger of Residential Airconditioner

EXERGY ANALYSIS OF DOMESTIC REFRIGERATOR WITH DIFFERENT REFRIGERANTS

Thermodynamics II Chapter 5 Refrigeration

Performance Comparison of Ejector Expansion Refrigeration Cycle with Throttled Expansion Cycle Using R-170 as Refrigerant

Introduction of Transcritical Refrigeration Cycle Utilizing CO2 as Working Fluid

THE ANALYSIS AND EXPERIMENTAL INVESTIGATION OF HEAT PUMP SYSTEM USING THERMOBANK AND COS EJECTOR CYCLE

Effects of Frost Formation on the External Heat Transfer Coefficient of a Counter-Crossflow Display Case Air Coil

Refrigeration Cycle And Compressor Performance For Various Low GWP Refrigerants

TYPICAL INITIAL OUTPUT OF A CO 2 HEAT PUMP

Technical Presentation on

Thermodynamics: Homework A Set 7 Jennifer West (2004)

PREDICTION OF THE PRESSURE DROP OF CO 2 IN AN EVAPORATOR USED FOR AIR COOLING ABSTRACT 1. INTRODUCTION 2. EXPERIMENTAL SET-UP AND PROCEDURE

INTERNSHIP REPORT 1/3

Transcritical CO2 Bottle Cooler Development

Refrigeration Cycles MOHAMMAD FAISAL HAIDER. Bangladesh University of Engineering and Technology

Introduction of Panasonic CO2 refrigeration system. Panasonic Corporation Refrigeration and Air-Conditioning Devices Business Division

Experimental Investigation of a New High Temperature Heat Pump Using Water as Refrigerant for Industrial Heat Recovery

THE FIVE W s SYSTEMES LMP MECHANICAL SUB-COOLING. I.G.A. GIRARD, TERREBONNE, Qc. INCREASED SYSTEM EFFICIENCY & LOWER ENERGY COSTS

2. CURRICULUM. Sl. No.

Volume 3, Issue 4 (2015) ISSN International Journal of Advance Research and Innovation

Performance of R-22, R-407C and R-410A at Constant Cooling Capacity in a 10

Comparison Simulation between Ventilation and Recirculation of Solar Desiccant Cooling System by TRNSYS in Hot and Humid Area

Air Conditioning Inspections for Buildings Efficiency of Air Conditioning Systems

INTERNSHIP REPORT 1/3

Application of two hybrid control methods of expansion valves and vapor injected compression to heat pumps

Experimental Investigation of Hot water Fired R134A-DMAC VARS System at Various Heat Source Temperatures

Chapter 10. Refrigeration and Heat Pump Systems

Development of R744 Two Stage Compressor for Commercial Heat Pump Water Heater

HVAC Water chiller selection and optimisation of operation

Healthy Buildings 2017 Europe July 2-5, 2017, Lublin, Poland. Experimental study of a novel dew point indirect evaporative cooler

Specific Energy Consumption of Heat Pump Drying System

CHAPTER 7 PERFORMANCE ANALYSIS OF VAPOUR COMPRESSION REFRIGERATION SYSTEM IN HYBRID REFRIGERATION SYSTEM

Performance analysis of ejector refrigeration system with environment friendly refrigerant driven by exhaust emission of automobile

Purdue e-pubs. Purdue University

Volume 2, Issue 4 (2014) ISSN International Journal of Advance Research and Innovation

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid

Performance Investigation of Refrigerant Vapor- Injection Technique for Residential Heat Pump Systems

HICOSYS FOR PROCESS CONTROL OF SPRAY DRYERS

Heat pump supplemental heating system for motor vehicles

HFO-1234yf Performance in a Beverage Cooler

Welkom. Optimalisatie CO2 systemen m.b.v. ejecteur

Drying Process and Energy Economics

Main Anthropogenic Sources of Greenhouse Gases Refrigerants

Experimental Investigation of a Heat Pump Assisted Fluidized Bed Dryer

DEVELOPMENT OF A DYNAMIC HEAT PUMP DRYER TEST BENCH TO DEMONSTRATE ENERGETICAL OPTIMIZATION POSSIBILITIES BY REPLICATING REAL LIFE DRYING PROCESSES

Air Conditioning Inspections for Buildings Efficiency of Air Conditioning Systems

Scientific Principals and Analytical Model. Charcoal Cooler. Lisa Crofoot MECH 425, Queens University

Thermodynamic analysis of air cycle refrigeration system for Chinese train air conditioning

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

A study on retrofit methodologies for legacy air-conditioning systems to reduce their impact on global warming and ozone depletion

TEST REPORT #43. System Drop-in Tests of Refrigerants L-41-1, L-41-2, and R-32 in Water-to- Water Heat Pump

DRYPACK - A CALCULATION AND ANALYSIS TOOL. Kongsvang Allé 29, DK-8000 Aarhus, Denmark

Oxyvap Evaporative Cooling Applications

Screw compressors SCK Capacity: m 3 /min

Combination unit to support instruction in Thermodunamics, Fluid Mechanics, and Heat Transfer

Vapour Compression-Absorption Cascade Refrigeration System- Thermodynamic Analysis

SHS AS A TECHNOLOGY PLATFORM FOR SUSTAINABLE & COMPETETIV ADVANTAGE

Refrigeration dryer series AS Highest level of operational reliability

Refrigerants Type Expensive Coefficient of Performance Toxic

Math. The latent heat of fusion for water is 144 BTU s Per Lb. The latent heat of vaporization for water is 970 Btu s per Lb.

Adsorption refrigeration system using waste heat

IP TRONIK. Project Scope: Simulation of car refrigerant circuit with the software GT SUITE and its comparison with real test bench measurements

ErP. ErP READY. The Eco-Design Directive ErP for refrigerator systems and heat pumps. READY

Refrigerator and Heat Pump Objectives

An Experiment of Heat Exchanger Produces Hot Water Using Waste Heat Recovery from Air Conditioning

Chapter 11 REFRIGERATION CYCLES

Modelling the Performance of a Diffusion Absorption Refrigeration System

Transcription:

Heat Pump Fluidised Bed Dryer with CO 2 as Refrigerant Measurements of COP and SMER Trygve M. Eikevik, Ingvald Strømmen, Odilio Alves-Filho Norwegian University of Science and Technology (NTNU) Department of Energy and Process Engineering Trondheim, Norway, +47 73593860, +47 73593950, Trygve.M.Eikevik@ntnu.no Odilio.Alves@sintef.no, Ingvald.Strommen@ntnu.no ABSTRACT A prototype fluidised bed heat pump dryer with CO 2 as the working medium is constructed and build at the Dewatering R&D Laboratory at SINTEF and NTNU. The dryer is designed to use different inert gasses in the drying chamber, also included to run in under and over atmospheric pressure. This opens up for possibilities to test product under different conditions and investigate influence on the heat and mass transfer during the drying. The drying chamber can be changed and can operate in both fluid bed and static bed, and can be run in continues and batch operations. The options of the drying chamber gives possibilities to dry granulates or peaces/particles, foamed products, and liquids. It is also possible to coat, granulate particles and to agglomerate new particles. To meet hygienic regulations the plant is build in stainless steel with CIP washing system, including 2.2 bar steam for sterilising. The heat pump circuit is constructed to use CO 2 as working media with maximum working pressure of 130 bars. To operate in a wide range of temperatures ( 20 o C to +90 o C) in the drying chamber the heat pump process will operate in a traditional way with evaporating and condensing mode, in a transcritical mode and also in a pure gas mode at high temperatures. These running conditions are depending of the product and its sensitivity of heat. In this paper tests of the plants are described and measured coefficient of performance and specific moisture extraction ratio are presented. INTRODUCTION Heat pump drying requires proper design of the size of the components of the refrigeration cycle. In reality the compressor capacity will control the efficiency of the plant together with the size of the heat exchangers, especially the evaporator. To large compressor capacity will give to low temperature in the evaporator and an inefficient energy use. It is therefore a challenge to make a laboratory heat pump dryer that shall operate at a wide range of temperatures. The size is optimal at only one temperature and that is at the lowest operation temperature level. At all other temperature levels the laboratory heat pump is out of design point due to the large compressor. At some extent this can be adjusted by installing a frequency controller. In a plant with CO 2 as refrigerant the thermodynamic process will operate at different operational modes such as; ordinary refrigeration cycle with condensation 1

and evaporation; transcritical operation with cooling of the refrigerant at pressures above the critical point (cooling of a compressed gas without condensation) and evaporation; gas cycle where the refrigerant is totally above the critical point of the refrigerant. This is shown in figure 1. Figure 1 TS-diagram for the three different refrigeration cycles for the CO 2 process The CO 2 process in the transcritical operation can be optimized bay increasing the pressure on the outlet of the compressor. The CO 2 gas temperature out from the air heater is kept constant and the pressure is increasing. As shown in the figure 2 the specific evaporation capacity will increase. At a given pressure the process will have the optimum COP. The optimized pressure level is controlled by the expansion valve with a high pressure sensor. It is then necessary to have a low pressure receiver at the outlet of the evaporator to accumulate the variation in the refrigeration charge at the high pressure side. Figure 2 Log P-h diagram for the CO 2 process in transcritical operation The refrigeration capacity needed over the operational temperature range of the dryer is relatively constant. In figure 3 this is shown for the temperature range from -20 o C to +90 o C and at a relative humidity of 30% at the inlet of the dryer and 70% at the outlet of the dryer. As shown the necessary cooling capacity varies from 2.5 kw to 3.2 kw. This is not possible to achieve with one compressor because of the thermodynamic properties of the refrigerant. 2

To meet this challenge it is necessary to have more than one compressor and in addition the compressor speed should be tuned by at frequency controller. Figure 3 Air cooler capacity at different temperature levels at the inlet of the drying chamber The laboratory plant (see figure 4) at the Dewatering R&D Laboratory at NTNU and SINTEF is designed to operate at the temperature range from -20 o C to +90 o C. The plant is build in stainless steel and is equipped with CIP washing system and with steam sterilizations system. The diameter of the fluid bed is possible to vary from 10cm to 35cm and the air flow can vary from 100 to 800m 3 /h. The variation in air flow gives an oversized air fan with higher energy consumption than a normal plant is requiring. Figure 4 Photo of the laboratory fluid bed dryer with CO2 as refrigerant Figure 5 shows the drawing of the laboratory plant. The plant has two external heat exchangers cooled with water to remove the excess heat form the plant. A heat pump dryer with closed loop will require energy to circulate the air in the drying system and to transport energy from the heat exchanger for cooling of the air and the heat exchanger for heating of the air to make the drying potential. This energy used to run the fan and the compressor has to be removed in the external heat exchanger. 3

Figure 5 Schematic drawing of the fluid bed dryer with CO2 as refrigerant The new fluid bed dryer with CO 2 as refrigerant has shown very stable drying conditions within ±0.5 o C temperature variations at the inlet of the drying chamber. The relative humidity at the inlet of the drying chamber is given by the cooling capacity of the air cooler. To have the possibility to control the relative humidity at the inlet of the drying chamber there have been installed a spray nozzle for water after the air heater. RESULTS There have been run test of the heat pumping system at temperatures at +30 o C, +40 o C and +50 o C. The product in the drying chamber has been plastic bids with a size of 3mm length and a diameter of 1.5mm. There has been added water in the fluid bed chamber with a water spray nozzle to simulate the drying process. The amount of water added has been controlled to meet 60% relative humidity at the outlet of the drying chamber. This is shown in figure 6. At this test the relative humidity at the inlet of the dryer was 20%. Figure 7 shows the CO 2 process in the Ts-diagram Figure 6 Mollier-diagram for drying process at air inlet temperature of 40 o C Due to the relative high capacity of the air blower the total energy consumption of the plant is higher than expected. This reduces the coefficient of performance for the plant. To reach the 20% relative humidity at the inlet of the dryer, the air is cooled to a lower temperature than 4

the dew point. In figure 7 the yellow line (at high pressure) shows the heat removed in the external heat exchanger. The dark blue line is the air heating energy. Figure 7 Ts-diagram for the CO2 process with drying process at 40 o C air inlet drying temperature The following data have been measured for the three tests. Table I. Results from the tests performed on the CO 2 heat pump Air inlet temperature of drying chamber 30,3 40,6 50,7 Relative humidity inlet air 23,9 20,0 12,8 Air outlet temperature of drying chamber 22,3 28,6 32,5 Relative humidity outlet air 60,5 60,1 60,8 COP 2,71 2,31 4,18 SMER 1,73 1,65 3,73 CONCLUSIONS There have been installed a new fluid bed dryer in the dewatering laboratory at NTNU and SINTEF with CO 2 as refrigerant. The plant is designed to operate at a wide range of temperatures. This gives operating conditions for the heat pump far out from the design point. The fan is oversized and reduces the COP for the process. The SMER values for the plan have been measured from 1.65 to 3.73 at different drying air temperatures. REFERENCES 1. Eikevik, T.M., Alves-Filho, O., Strømmen, I.: Carbon-dioxide heat pump dryer and measurements on coefficient of performance and specific moisture extraction ratio. 2 nd Nordic Drying Conference, NDC2003, Copenhagen, Denmark, June 2003. 2. Eikevik, T.M.; Alves-Filho, O.; Strømmen, I.: Potential applications for a new CO 2 heat pump dryer. NDC 2001, Trondheim, Norway, June 27-29, 2001. 3. Alves-Filho, O.; Lystad, T.; Eikevik, T.M.; Strømmen, I.: 2000, A new carbon diocide heat pump dryer An approach for better product quality, energy use and environmentally friendly technology. IDS 00, Nordwijkerhout, Nederland, August 28-31, 2000. 4. Eikevik, T.; Alves-Filho, O.; Strømmen, I.: Dimensioning of heat pump dryer components An economical operation for quality, energy use and water removal. IDS 00, Nordwijkerhout, Nederland, August 28-31, 2000. 5. Eikevik, T.M.; Strømmen, I.; Alves-Filho, O.: Design and dimensioning criteria of heat pump dryers. The 20 th International Congress of Refrigeration, IIF/IIR, Sydney, Australia, 1999 5