D5.1.12_Drain_Water_Heat_Recovery_in_Retro fits

Similar documents
The importance of hot water system design in the Passivhaus

ENERGY ANALYSIS OF HEAT PUMP WITH SUBCOOLER

DWHR Testing at the CCHT. ACE 3 Hot Water Forum Pacific Grove, California 9 June 2009 John Gusdorf

Installation Instructions

WP2 European Product Analysis, Task 2.1 Determining energy efficiency criteria, D 2.1 Periodic Criteria Papers (first set)

Standard Assessment Procedure Instantaneous Waste Water Heat Recovery Systems Design Checklist for 'System A' Installation Configuration

FREQUENTLY ASKED QUESTIONS

Heat loss via internal drainage vent pipes

Standard Assessment Procedure Instantaneous Waste Water Heat Recovery Systems Design Checklist for Configurations A, B & C

Comparison of energy efficiency requirements of the energy labels and ecodesign legislations

Energy efficient swimming pools 1.1 A SMART, EFFICIENT CLIMATE SHELL REFURBISHMENT SOLUTION

Modelling the Performance of a Diffusion Absorption Refrigeration System

VARIABLE HEAT RECOVERY IN DOUBLE BUNDLE ELECTRIC CHILLERS. Richard J Liesen 1, Rahul J Chillar 2 1 University of Illinois at Urbana Champaign

Drain Water Heat Recovery (DWHR) Energy Efficient Installations

Beneficiary: Multifamily-house building. Valladolid Spain. Consultant: ROTARTICA FAGOR ELECTRODOMÉSTICOS IKERLAN

Technical Sheet. Heat recovery appliance Renovent Excellent 400 (Plus) Renovent Excellent 400 1

> ENERGY NEED FOR A STANDARDIZED SUPERMARKET: HEATING, COOLING, REFRIGERATION. > Deliverable 8. With the support of : November 2007

Performance of Heat Recovery Ventilation System with Ground Source Brine Heat Exchanger Pre- Heating System in the Context of nzeb

Energy Labels. Common appliance policy All for one, One for all

Come On Labels Common appliance policy All for one, One for all Energy Labels. New EU legislation related to energy labels on household appliances

PAMA PRODUCT PASTEURIZATION, HEATING AND COOLING SYSTEMS

PRODUCT DATA SHEETS HEAT PUMPS

BNDH EWH01: Domestic Electric Water Heaters Government Standards Evidence Base 2009: Key Inputs

Both regulations are due to be reviewed by Key topics to be assessed during the reviews include:

Desiccant Cooling with Solar Energy

China Bathroom Study 2014

your comfort. our world. Altherma Flex Type Renewable heat pump system for every environment

EXHAUST AIR HEAT PUMPS EVALUATED FOR NORDIC CIRCUMSTANCES

Copyright 2003 IBACOS, Inc. All rights reserved.

Ventilation. Product Information

Installation Manual WARNING. Add-on Controller Installation Kit NPE-180A/210A/240A

HYBRID GAS HEAT PUMP WATER HEATER WITH THERMAL EFFICIENCY 120% 23rd World Gas Conference, Amsterdam Main Author. Atsuya Tajima Japan

Installation instructions. RECOUP Retrofit+ Shower Waste Water Heat Recover unit

Energy Efficiency Solutions

Residential Heat Recovery Ventilation. REHVA European Guidebook No 25

DOMESTIC LINE DUPLEX EASY

QUALITY CONTROL Passive House Checklist

RHEEM CONTINUOUS FLOW GAS HOT WATER YEAR WARRANTY ENERGY L/MIN GAS HOT WATER THAT NEVER RUNS OUT. factor COMES ON STEADY, HOT AND STRONG INSTALL A

UNIQ HEAT BATTERIES REFERENCE MANUAL_V2.2. Version: 2018_07_19_v2.2

Distribution Restriction Statement

Energy Options for Residential Heating. Juergen Korn, P.Eng.

57 Cae Brackla Brackla Bridgend. CF31 2HE

Case Virkakatu, Oulu, Finland

Hot water on demand with incorporated energy saving function

Time to rethink heating

Emergency Wall Communicator

Installation Manual NPE-180A/240A WARNING. Add-on Controller Installation Kit

B COMMISSION REGULATION (EU)

Scholars Research Library

Comprehensibility of the Energy Label for space heaters and water heaters and of the new Efficiency Label for old space heaters in Germany

Modular Construction. Live/Work Urban Infill Townhome. Modular Construction. Enclosure Design. San Francisco Bay Area Net Zero Urban Infill

Energy Efficiency Standards

THE RISK OF LEGIONELLA DEVELOPMENT IN SANITARY INSTALLATIONS

Open Cycle Liquid Desiccant Air Conditioning Systems Theoretical and Experimental Investigations

Workshop The Future of Social Acceptance SuedLink BESTGRID pilot project

of the liquid prior to it entering the expansion device. By doing so, the capacity for

Synergy Potential of Smart Domestic Appliances in Renewable Energy Systems

Drain Water Heat Recovery

NATURAL CONVECTION HEAT EXCHANGERS FOR SOLAR WATER HEATING SYSTEMS. Technical Progress Report April 1,1995 to May 31,1995

VENTILATIVE COOLING CONTROL STRATEGIES APPLIED TO PASSIVE HOUSE IN ORDER TO AVOID INDOOR OVERHEATING

ME 410 MECHA ICAL E GI EERI G SYSTEMS LABORATORY

Temperature Rises as Products Compete in the Heat. Market. Contact: Tim Page Press Release No: 20. Release date: Immediate Date: 11/11/09

Vireo Fresh intelligence

Energy smart living. Baltic Environmental Forum Latvia Antonijas iela 3-8 LV-1010 Riga, Latvia

Christof Horvath, Austrian Energy Agency. Eva Geilinger, Bush Energie GmbH

A SIMPLIFIED MODEL FOR SIZING AND CHARACTERIZING A NATURAL CONVECTION HEAT EXCHANGER SYSTEM

Domestic Hot Water production

Measurement and modelling of a multifunctional solar plus heatpump system from Nilan. Experiences from one year of test operation.

(Non-legislative acts) REGULATIONS

Parameter guide 95M-200 GAS-FIRED DIRECT VENT MODULATING HOT WATER BOILER WARNING WARNING

For the owner and the heating engineer. Operating and Installation Manual VRC 400. Programmable weather compensator with separat HW time control

Applications of Thermodynamics: Heat Pumps and Refrigerators

Daikin VRV Sizing & Simulation Plug-in User Guide

21 Exley Lane Elland HX5 0SW 235,000. Professionalism with Independence. 12 Victoria Road, Elland, HX5 0PU t:

Some Heat Transfer Problems. A hydrocarbon oil (mean heat capacity = 0.50 BTU/(lb m

IWT-TETRA: ZON-WARM. Solar Thermal and Heat Pump Systems. Domestic Hot Water production. Jan Verheyen. Warmtepomp Symposium 11/09/2013

Installation and Servicing Instructions. Alpha GasSaver GS-2

Beneficiary: Unifamily-house. Seville Spain. Consultant: ROTARTICA FAGOR ELECTRODOMÉSTICOS IKERLAN

ME 410 MECHANICAL ENGINEERING SYSTEMS LABORATORY MASS & ENERGY BALANCES IN PSYCHROMETRIC PROCESSES EXPERIMENT 3

Next Generation Passivhaus Archives

Commercial and Professional Refrigeration Products: Promoting Energy Efficiency with Legislation, Empowered Stakeholders and Rebates

*Bioenergy GmbH Gewerbepark Haag 3, 3250 Wieselburg Land, Austria

Developer, new connection and infrastructure charges

THERMOSTATIC CONTROL TECHNOLOGY HORNE 40 AND 50 THERMOSTATIC MIXING SYSTEMS

Open and Closed Door Moisture Transport and Corresponding Energy Consumption in Household Refrigerator

4 th Generation District Heating. Dr. Oddgeir Gudmundsson Director of Projects Application Center Danfoss Heating Segment

AERECO DEMAND CONTROLLED VENTILATION COMBINING INDOOR AIR QUALITY AND ENERGY SAVINGS

September 11, 2012 Ministry of Economy, Trade and Industry

Efficiency of Application the Condensing Heat Utilizers in the Existing Boiler's Unit in Heat Power Station

Seasonal Performance and Exergy Analysis of Multi-Function Heat Pump Units

Installation and Servicing Instructions. Alpha GasSaver GS-1

Zehnder ComfoAir flat 150

Building services installation. Sustainable retrofitting of buildings- Sub module 3

Green Energy Waste Heat Recovery Solutions

DPC-1 Programmable digital thermostat with communication Versión 2.0. Technical Information. Ref: N

Specs for endconsumers. communication

for family composition, time allocation of people, ownership and specification of home appliances. This paper first presents the simulation procedure

Energy Check in Superbrugsen, Samso

Specialized in the design and the tailor-made production of dryers, coolers and thermal processing equipment for industrial use.

Installation and Servicing Instructions

Transcription:

D5.1.12_Drain_Water_Heat_Recovery_in_Retro fits INTELLIGENT ENERGY EUROPE II Energy efficiency and renewable energy in buildings IEE/12/070 EuroPHit [Improving the energy performance of step-by-step refurbishment and integration of renewable energies] Contract N : SI2.645928

Technical References Project Acronym Project Title Project Coordinator Project Duration EuroPHit Improving the energy performance of step-by-step refurbishment and integration of renewable energies Jan Steiger Passive House Institute, Dr. Wolfgang Feist Rheinstrasse 44/46 D 64283 Darmstadt jan.steiger@passiv.de 1 April 2013 31 March 2016 (36 Months) Deliverable No. Dissemination Level Work Package Lead beneficiary Contributing beneficiary(ies) Author(s) D5.1.12 PU WP5_Product Development 05_iEPD 01_PHI Jürgen Schnieders Co-author(s) Date 29.09.2015 File Name EuroPHit_D5.1.12_DWHR_PHI.doc The sole responsibility for the content of this publication lies with the authors. It does not necessarily reflect the opinion of the European Union. Neither the EACI nor the European Commission are responsible for any use that may be made of the information contained therein. - 2 -

Table of Contents Abstract 4 1 Drain Water Heat Recovery in Retrofits 5 1.1 Principle 5 1.2 Calculation of Energy Savings 5 1.2.1 Symbols, Units, Explanations 7 1.3 Requirements 8 2 Application in Retrofits 9 List of figures and tables Figure 1 - Examples for DWHR systems... 5 Table 1 - Symbols, Units & Explanations... 7 Table 2 - Passive House Efficiency Classes for Drain Water Heat Recovery... 8-3 -

Abstract The goal of a step-by-step refurbishment is to minimize the total energy consumption of a building. At the end of the retrofit, the building s heating consumption may be smaller than its domestic hot water consumption. Therefore, hot water should be considered in a step-bystep refurbishment plan, too. One of the options to reduce hot water energy consumption is the principle of heat recovery from flowing, warm drain water. The corresponding devices are small, simple, and without moving parts. They can save approximately one third of the useful hot water consumption. This document describes the principle of drain water heat recovery, outlines a calculation procedure for the resulting energy savings, informs about certification and efficiency classes, and provides hints for the construction of such devices. - 4 -

1 Drain Water Heat Recovery in Retrofits 1.1 Principle In this publication, the term drain water heat recovery (DWHR) describes a passive method to reduce the total energy demand of buildings. In particular, DWHR reduces the useful energy required for water heating by using heat from flowing waste water to preheat the domestic hot water (DHW). Typically, these systems do not require large storage tanks, heat is only transferred from the flowing drain water to the incoming water. Figure 1 - Examples for DWHR systems Due to the high heat transfer coefficient of water it is possible to achieve steady-state efficiencies of the heat exchanger itself of more than 70%. The systems recover heat only when the flows of waste water and fresh water occur simultaneously. They are particularly interesting for heat recovery from showers, but do not e.g. reduce the energy required for bathing. Storage and distribution losses also remain unaffected. 1.2 Calculation of Energy Savings The calculation methodology that is outlined here refers to showering because it is the most important application in this respect. Other hot water uses can be treated similarly. The method has been implemented in the Passive House Planning Package PHPP in version 9. The steady-state efficiency of the heat exchanger itself at balanced mass flows can be calculated from (cf. Table 1 in section 1.2.1 for an explanation of the symbols) - 5 -

η T, HX T = T DW ' T ' T It is important to note that there are relevant heat losses in the shower between the shower head and the drain (whereas heat losses in the pipes can be neglected). Considering these, the fraction of the hot water load that is actually covered by the system under steady-state conditions is given by η DWHR DW ( T T ) ( T T ) m& ' = & m SW Differences between the mass flows will occur if only one of the hot and cold water connections of the shower are connected to the DWHR. In this case, the mass flows can be calculated from the temperatures T SW, T, and T HW. Assuming a counterflow heat exchanger, the following equation holds: η T, HX 1 e = W 1 W DW X e X where X 1 1 = UA W DW W For balanced mass flows these formulae become 1 η T, HX = W + 1 UA If η T,HX is measured under balanced mass flows, the above relationships allow for the determination of UA, from which η T,HX can also be calculated for unbalanced mass flows. Furthermore, the efficiency of the heat exchanger at higher or lower mass flows can be estimated by a method based on the Number of Transfer Units of the heat exchanger. Finally, considering just steady-state conditions is not adequate. There is some delay before all components have achieved their steady-state temperature. Such dynamic processes typically reduce the amount of heat recovered by another 10%. Altogether, calculations as well as measurements show that for efficient DWHR units and appropriate installations the total reduction of heat consumption is approximately 35% of the energy used to provide the useful hot water demand. - 6 -

1.2.1 Symbols, Units, Explanations Table 1 - Symbols, Units & Explanations Symbols Unit Explanation m& [kg/min] Water mass flow on fresh water side m& [kg/min] Water mass flow on drain water side DW T [ C] Fresh water temperature at entrance of heat exchanger T ' [ C] Fresh water temperature at exit from heat exchanger T DW [ C] Drain water temperature at shower drain T DW' [ C] Drain water temperature at heat exchanger T HW [ C] DHW system temperature T SW [ C] Water temperature used for showering UA [W/K] Heat transfer coefficient of the heat exchanger W [W/K] Capacitance rate on fresh water side W DW [W/K] Capacitance rate on drain water side η DWHR [-] Fraction of shower water heat load covered by DWHR under steady-state conditions η T,HX [-] Steady-state efficiency of heat exchanger - 7 -

1.3 Requirements From the above it can be seen that it is sufficient both for the characterisation of DWHR units and for the calculation of the expected savings to measure two properties: the steady-state efficiency at a typical flow rate the dead time These values are used for certification as a Certified Passive House Component. To obtain the certificate, the units have to provide at least a reduction of the useful energy expenditure for shower water, i.e. η DWHR from above, by 30% The steady-state efficiency of the DWHR typically needs to be 25 to 30% higher because of the temperature loss in the shower and the dynamic losses in the DWHR itself. To distinguish between units of different efficiencies, Passive House efficiency classes were determined as given in Table 2. Table 2 - Passive House Efficiency Classes for Drain Water Heat Recovery Shower water - useful heat saved Passive House Efficiency Class Description 60% pha+ Very advanced component 50% pha Advanced component 40% phb Basic component 30% phc Certifiable component < 30% Not certifiable - 8 -

2 Application in Retrofits The installation of a DWHR requires sufficient space for the unit and connections to the drain water as well as, ideally, to both the hot and cold water connection of the mixing tap. This is simple in new buildings, but may be very difficult in retrofits unless a major renovation of the whole hot and cold water system is required anyway. Nevertheless, in many deep retrofits the bathrooms will be remodelled sooner or later to adapt to current comfort and design standards. This is a good opportunity to install a DWHR. Design recommendations for DWHR systems in retrofits can be given as follows: 1. For any DWHR device whatsoever, there is some cost and effort involved in production and installation. Designers should consider aiming at the maximum possible efficiency to warrant this effort. Often high efficiency can be achieved by changing small details that provide turbulent flow, equal flow distribution, and optimized heat transfer in the solid parts of the heat exchanger. 2. If the flow of the drain water remains undisturbed, like in the duct-type DWHR units as shown in Figure 1 on the right, the units can be totally maintenance-free. For systems where regular cleaning is required it should be made as simple as possible. 3. Shower basins with an integrated DWHR (at a reasonable height difference), as shown in Figure 1 on the left, are particularly advantageous in retrofits. They can be installed as soon as the shower basin is changed and the cold water side of the mixing tap becomes accessible. It is not necessary to wait for all pipework in the building to be exchanged. In addition, the heat exchanger is situated very close to the drain and the shower head, thus minimizing dynamic lossses. 4. Horizontal drain pipe runs of several meters length are often available. It is possible to install duct-type DWHRs horizontally instead of the default exactly vertical installation, but their efficiency is reduced dramatically. Dedicated horizontal units with high efficiency would open the door for additional applications. 5. For typical DHW consumption levels in larger dwelling units, DWHR systems are economically interesting when considered over their total expected lifetime. For households with one or two persons, however, the economics become questionable. With increasing sales figures manufacturers should aim at reducing sales prices below the current levels. Given that DWHR units do not provide customers with additional benefits like increased comfort or prestige, the main argument for their installation will be the savings in DHW production cost. - 9 -