Product Instruction Manual. Jetstream JET1600 (white) & JET1600BSS (brushed stainless steel) 1.6 kw automatic hand dryer V15.

Similar documents
TSL hand dryer. installation + maintenance

Handyflow Undersink HF05MVC

SC2000Y, SC2000YST, SC2000YM

TH01B, TH02B, TH03B, TH04B

Automatic Infrared Tap TAPIFR. Instruction Manual

HS&S Alert No: 103 Date: 9 March 2017

AC500T, AC1000T, AC1500T, AC2000T

Zen Boiling Tap Range

Powerflow Unvented water heater

Biobot Hand dryer. Automatic. High Speed

Eco. Hand dryer. Automatic. High Speed

Speedflow Undersink Unvented Water Heater. Models SF05K, SF10K and SF15K. Instruction Manual

I storm. Circular High Speed Hand Dryer. Model N2 : I storm...,. Patent Pending. Operating Instructions and Parts Manual

MICATHERMIC PANEL HEATER

10L Dehumidifier. Model Number: LDH V AC 50/60Hz 290W

Heated Display. Instruction manual. Model: CW147 / CW148

Owner's Manual. Please read this document carefully before installing and/or using your vacuum cleaning system.

Business². Hand dryer. High Speed

Contact Details. Please note that some of the contact details on this PDF document may not be current.

POWERFLOW Series. Unvented Electric Storage Water Heaters. Installation & Operating Instructions Manual

ELECTRIC FIREPLACE with Remote Control

SP16. 08/50740/1 (UK) - Issue 1

PTC Ceramic Heater. Instruction Manual THE SCIENCE BEHIND HEAT

Contact Details. Please note that some of the contact details on this PDF document may not be current.

Business Hand dryer High Speed

Saletto. Operating Instructions. Low Profile Panel Heaters Models: LPP050 LPP075 LPP100 LPP150. A world of expertise

YOUR SAFETY & INSTRUCTION MANUAL PLEASE READ CAREFULLY HAIR DRYER MODEL C80002

INFRARED IP55 HEATER INSTRUCTIONS FOR: MODEL:- QZWP45N 1. SAFETY INSTRUCTIONS

HERSCHEL SUMMIT 2600 HERSCHEL SUMMIT 2600R Ceiling or Wall-mounted Infrared Heaters

Trimbox Mixed Flow Fans. Product Manual. ventilation systems TP220T TP221T TP222T TP223T

Business² Hand dryer

OPERATING INSTRUCTIONS

7 Fin Oil Filled Radiator

ZIP InLine. Models: ES3, ES4 & ES6. Electronic Instantaneous Water Heaters. ES3, ES4 & ES6 Instructions. V1.09 Page 1 November / 2015

FAN-FORCED UTILITY HEATER

Hand Dryer Installation & User Manual

Girona. Operating Instructions. Glass Panel Heaters. Models: GFP050 W/B GFP075 W/B GFP100 W/B GFP150 W/B GFP200 W/B. A world of expertise

INSTALLATION MANUAL Wolfen Slimline Hand Dryer Stainless Steel. Installation Details Warranty

USER MANUAL. ICON60H Version 00. Vertical Glass Hood

Radiant Heater. Instruction Manual QH-200 N13275

PRACTICAL USER S GUIDE FOR THE DIMPLEX ELECTRIC FIREPLACE WITH REMOTE CONTROL

BLOW DRY & GO HAIR KIT

INSTALLATION & USER INSTRUCTIONS

airooncentre.co.uk irconcentre.co.uk Xpelair Low Energy Wall/Window Fan Range GX6 EC2 GXC6 EC2 Quick Order Hotline or

PRACTICAL USER S GUIDE FOR THE DIMPLEX PURIFIRE ELECTRIC STOVE

User Instructions for Remote Controlled 2kW Rotisserie Effect Fan Heater Model 1276

IMPORTANT- RETAIN FOR FUTURE REFERENCE CALL:

Contact Details. Please note that some of the contact details on this PDF document may not be current.

Contact Details. Please note that some of the contact details on this PDF document may not be current.

PORTABLE AIR CONDITIONER

Hardwired Electric Garage Heater

JUNEAU JUN. 08/51193/0 Issue 0

PRACTICAL USER S GUIDE FOR THE ELECTRIC STOVE

ELIX 1003 IPX4. Energy Efficient Centrifugal Fan with EC Motor Installation and Operating Instructions

Installation Instructions & Operating Manual IMPORTANT

Ecostrad Amalfi. Wall-mounted Infrared Heater INSTALLATION & OPERATING INSTRUCTIONS. 3kg 2 Years (excludes lamp & remote control) IP65

CG60/ 70/ 80/ 90/ 100 SS/BK

INSTALLATION AND USER INSTRUCTION GUIDE. Electric Fire With Remote Control. Model: WM-3522CF. Please read all instructions carefully and

Electronically controlled instantaneous water heater. MCX: 27300, and models. Installation instructions

EH kW Panel Heater

Wall Mount Electric Fire Place with Remote Control

Hot Chocolate Dispenser

Series Automatic Hand Dryer. Operating Instructions for the User & Installation Instructions for the Licensed Installer

100cm Chimney Hood GB IE


2.8KW ELECTRIC FAN HEATER

Electric Garage Heater

2kW Wall Mounted Electric Fire Complete with flat glass front panel. Installation Instructions & Operating Manual

AMBION FLAME. INSTALLATION AND USER INSTRUCTIONS

IM-H12A Hand Held Vacuum Cleaner. Instruction Manual Model Ref: H12 / Cat Number: DN907

Models: RP-10, RP-15, RP-20. User Manual

IMPORTANT SAFETY INSTRUCTIONS DANGER: WARNING:

FAN HEATER FH118 User Manual

Food Steamer. Instruction manual. Model: CL205-A

IMPORTANT SAFETY INFORMATION:

THERMOFILM CONVECTIVE PANEL HEATER INSTALLATION, OPERATION AND MAINTENANCE MANUAL. Models: CP 2400 CP 2000 CP 1500 CP 1000 TABLE OF CONTENTS

20L Dehumidifier. Model Number: LDH V AC 50/60Hz 440W

Executive. Hand dryer. High Speed

OPTIMYST WALL ENGINE OMWFC20 RTOPW20 PEM20

Fundamental safety warnings

SH3020 USER INSTRUCTIONS

HAZEL OWNER S MANUAL INSTALLATION GUIDE WARRANTY

ART cm Island Curved Glass

Electronic Instantaneous Water Heaters Models: ES3, ES4 & ES6

INSTANT HOT WATER DISPENSER

ELECTRIC HEATER WITH CARBON FIBER HEATING ELEMENTS

Stick Mixer Set brushed stainless steel housing

The Arden Oscillating Floor Fan

Infrared Portable Space Heater

ISCG90SS _03 ISCG90SS

Contact Details. Please note that some of the contact details on this PDF document may not be current.

Model 1174 Electric Heater User instructions for LED effect 2kw Inset Heater

Contact Details. Please note that some of the contact details on this PDF document may not be current.

Convection Panel Heater

IM-H Hand Held Vacuum Cleaner. Instruction Manual Model Ref: H14 / Cat Number: DN909

CELSI ELECTRIFLAME XD

2kW UPRIGHT FAN HEATER INSTRUCTIONS FOR USE

Contact Details. Please note that some of the contact details on this PDF document may not be current.

e Bath Fan with Light User s Guide

ELECTRIC WALL HANGING FIREPLACE SUITE FUI0005_V2_ USE & CARE MANUAL

Transcription:

Product Instruction Manual Jetstream 1600 JET1600 (white) & JET1600BSS (brushed stainless steel) 1.6 kw automatic hand dryer V15.6/2 Version 3.2 Jan 2015

Thank you for purchasing the Hyco Jetstream hand dryer. The JET1600 is suitable for many public washroom applications including restaurants, shops and shopping centres, office buildings, pubs, motorway services, factories and supermarkets. Please read and understand these instructions before commencing installation, and leave them with the user when installation is complete. 1. Important safety points The Electrical installation must be carried out by a qualified electrician in accordance with the current edition of the I.E.E. Wiring Regulations. This appliance must be earthed. Means for electrical disconnection must be incorporated in the fixed wiring in accordance with the wiring rules. Only connect the hand dryer to a single phase supply with a mains voltage as specified on the rating plate. The hand dryer must be fixed out of reach of a person taking a bath or shower. This appliance can be used by children aged from 8 years and above and persons. with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision. Do not cover the air inlet or outlet. 2

2. Installation Wall Mounting The hand dryer must be fixed out of reach of a person taking a bath or shower. Place the supplied template against the wall at the desired height (see mounting height recommendations) and mark locations of 4 mounting holes and cable entry at knockout (KO) location. Note: For 2 or more dryers, dryers should be no closer than 610mm on centre. Remove and retain 2 cover screws and front cover. Drill 4 holes holes at locations A, B,C and D of 8mm diameter x 35mm deep. Using the fixings supplied, attach the dryer to the wall. Electrical This appliance must be earthed. Means for electrical disconnection must be incorporated in the fixed wiring in accordance with the wiring rules. The power cord should be connected following the colour coding below: Brown: L Blue: N Green / Yellow: E Hand Dryer 3

3. Operation Shake excess water from hands. To activate the hand dryer, place your hands underneath the air outlet to operate the sensor. Rub hands together lightly and rapidly. The dryer will stop automatically 1 second after removing hands. The dryer will also automatically cut-out after 1 minute of consecutive use. To re-start the hand dryer, put hands back underneath and re-operate the sensor. Air speed adjustment Gently prise the filter off from the underneath of the unit so the grille is exposed. Use a flat bladed screwdriver small enough to git through the access hole (4.8mm diameter) in the bottom grille (1). The adjustable potentiometer (20) is visible through the slots of the grille. Gently turn the potentiometer clockwise (CW) to increase power to maximum (shaft will meet a stop, DO NOT OVERTURN!). Turn the screwdriver gently CCW to reduce power as required. At minimum power the unit may not start if low line voltage condition exists. Sensor adjustment 1. The range is 2 to 13 (50mm to 330mm), standard settings is 7 (170mm + 20mm) 2. Clockwise: Increases the sensing range (+) 3. Counterclockwise: decreases the sensing range (-) 4. DO NOT OVERTURN! 4

4. Maintenance Periodic cleaning of the unit is recommended to ensure optimum performance. Disconnect the electrical supply. Remove the two cover-mounting screws. Remove the cover. Clean all dust lint from the interior of the dryer. Clean the exterior of the unit using a soft, damp cloth. Do not soak; never use abrasives to clean the cover. Replace the cover. Do not overtighten the screws. 5

5. Specifications Voltage Power Air speed (adjustable) Air volume (adjustable) Sound level IP Rating Weight 230V~50Hz 1.6kW 75-100m/s 87-116m3/h 77dB IPX1 5.8kg 287mm 205mm 180mm 6

6. Troubleshooting Symptom The dryer will not run The dryer cycles by itself or runs constantly The dryer makes a loud noise and does not run for a complete cycle The dryer runs but air stream is low pressure and/or low velocity Corrective action - Failure on installation Ensure that the breaker supplying the dryer is operational. If it is, disconnect the power and remove the dryer cover. Taking suitable precautions to avoid electric shock, reconnect the power and check for voltage at the terminal block. Verify that connections are made correctly. Ensure that there is no obstruction on or in front of the IR sensor. Clean any dirt or debris off the sensor lens. If problem persists replace sensor. Ensure that the supply voltage is correct as specified on the rating plate. If circuit board has been damaged, replace the circuit board and IR sensor module. Ensure that the supply voltage is correct as specified on the rating plate. The dryer will run weakly if the input voltage is too low. 7

Symptom The dryer will not run The IR sensor only sees close range objects The heater gets hot but the dryer is not blowing any air The dryer only blows cold air during a full cycle The dryer runs but air stream is low pressure and/or low velocity Corrective action - In service failure Ensure that the breaker supplying the dryer is operational. If it is, disconnect the power and remove the dryer cover. Taking suitable precautions to avoid electric shock, reconnect the power and check for voltage at the terminal block. Verify that connections are made correctly. Ensure that there is no obstruction on or in front of the IR sensor. Clean any dirt or debris off the sensor lens. Check variable resistor (VR) for sensor range setting. If problem persists replace sensor and/or circuit board module. Disconnect the power and remove dryer cover. Check variable resistor (VR) for speed setting. Disassemble the motor housing. Replace the fan motor. Reassemble. Disassemble the blower- motor/fan housing. Test the thermostat for open circuit. Check the heater element for signs of burning or breakage. Damaged element must be replaced. Check the air outlet for obstructions. If none are present, disconnect the power. Remove the dryer cover. Remove any dust/lint build up from the intake vent slots. Check VR for speed setting. Disassemble the motor/fan housing. Check the motor brushes for worn condition and replace them if necessary.

Repair parts list Key Part 1. C0109-4024 C0109-4025 2. D0109-0005 3. G0309-0005 4. A0110-0001 5. G0109-0002 6. E0109-0002 7. G0109-0004 8. AA0110-0002 9. TO209-0017 10. F0209-0007 11. A0110-0003 12. C0109-0013 13. F0301-0006 14. C0110-0001 15. CO109-0026 16. A0101-0022 17. A0101-0020 18. F0801-0003 19. D0101-0008 20. F0509-0001 21. C0109-0018 22. F0209-0011 23. C0101-0031 24. TO110-0005 Description Steel - White porcelain enamelled - JET1600 Stainless steel - Satin finished - JET1600BSS Security hex screw (2 reqd.) Shock absorber Blower housing - Top Motor rubber - Large Motor 700W Motor rubber - Small Blower housing - Bottom Heater element 900W LED assembly Air outlet Sensor bracket Sensor module Blower housing bracket Base plate Nylon hole bushing Cable clamp Terminal block Grounding screw VR (variable resistance) 100K VR bracket Circuit board module Security nex wrench Filter assembly

7. Guarantee and service policy This product is guaranteed against faulty materials and manufacture for a period of one year from the date of purchase. Hyco will in its sole discretion replace, repair or refund any faulty unit. Incorrect installation and failure to follow correct operating instructions are excluded. Consequential costs such as labour charges or damage to surroundings are expressly excluded.

INFORMATION FOR CORRECT DISPOSAL OF THE PRODUCT IN ACCORDANCE WITH THE EUROPEAN DIRECTIVE 2002/96/E. At the end of its working life this equipment must not be disposed of as household waste. It must be taken to a local authority waste collection centre or to a dealer providing this service. Disposing of electrical and electronic equipment separately enables its components to be recovered and recycled to obtain significant savings in energy and resources. In order to underline the duty to dispose of this equipment separately, the product is marked with a crossed out dustbin. Hyco Manufacturing Ltd Normandy Court Express Way Castleford, WF10 5NR T 01924 225 200 F 01924 225 210 E sales@hyco.co.uk hyco.co.uk