CORE Protection Fire System Specification

Similar documents
24V PCU CORE FIRE PROTECTION INSTALLATION SUMMARY

24V PCU CORE FIRE PROTECTION INSTALLATION SUMMARY

08/17/2011 Rev. 4 PULL STATION EXHAUST HOOD 10 TO 20 FEET FROM HOOD LOCATE ONE NEAR EVERY POINT OF EGRESS FROM HOOD

Project Name: Project Address: Installer Name: Installer Address: Date of Inspection:

R-102 RESTAURANT FIRE SUPPRESSION SYSTEM

ONLY CORE CERTIFIED PERSONNEL MAY INSTALL OR PERFORM MAINTENANCE AND REPAIRS ON CORE SYSTEMS.

Types of Detection. Fusible Link Detection - Most Common

PriceList Category PartNbr Part Description Weight (l MSRP

ANSUL TO-ANSUL. For more information... Check your local Yellow Pages for your authorized Ansul Restaurant Systems Distributor.

SPECIFICATION: DRY CHEMICAL FIRE SUPPRESSION SYSTEM FOR INDUSTRIAL APPLICATIONS MODEL IND

Agent Tanks PCL PCL PCL PCL - 600

SECTION KITCHEN HOOD AND DUCT FIRE SUPPRESSION SYSTEM

ANSUL ANSUL AUTOMAN II-C RELEASING DEVICE

KITCHEN HOOD AND DUCT FIRE SUPPRESSION SYSTEM

ANSUL. Twin-Agent Fire Fighting/Securing Systems Specifications. Models 450/50-B, 450/100-B, 900/100-B INDEX SPECIFICATIONS

The D1000. Typical Specifications: activate the mechanical fire suppression system. (pressurized potassium citrate / potassium acetate mix)

Twin-Agent Fire Fighting/Securing Systems Specifications

Second Revision No. 1-NFPA 17A-2016 [ Section No ] Submitter Information Verification. Committee Statement. 1 of 14 6/22/2016 3:15 PM

Carbon Dioxide Fire Suppression Systems

MINOOKA FIRE PROTECTION DISTRICT Fire Prevention Bureau Fire Inspector Rodney Bradberry

The D1000. Typical Specifications: Standard Options*: Model: D1030-I_-DF Spec & Submittal Version 2.3 D1000-I_-DF D1000-I_-DF-NFPA101

SPECIFICATION: CARBON DIOXIDE ENGINEERED FIRE SUPPRESSION SYSTEM

ANSUL AUTOMAN II-C EXPLOSION PROOF RELEASING DEVICE Installation, Operation, and Maintenance Manual

First Revision No. 49-NFPA 17A-2015 [ Detail ] Submitter Information Verification. Committee Statement 7/30/2015 1:35 PM

NFPA 96, 2017 REVIEW SUMMARY

2-SUPPRESSION REQUIREMENTS - CODE REQUIRED INSPECTIONS TEST Page 1 of 7

*** Inspection *** Please identify yourself as a Cintas representative when arriving onsite.

ISO INTERNATIONAL STANDARD. Ships and marine technology Fire-extinguishing systems for protection of galley cooking equipment

System Test Report CLEAN AGENT

Ships and marine technology Fireextinguishing. of galley cooking equipment

SPECIFICATION: ARGONITE Engineered Fire Suppression System

KITCHENShield WCK Kitchen Fire Suppression System. Advanced fire protection systems

K Series - Fire Suppression Systems for the Catering Industry

Special solution KS marine. Kitchen protection system KS marine Fire prevention for galleys

ANSUL I-101 INDUSTRIAL FIRE SUPPRESSION SYSTEM TECHNICAL MANUAL VEHICLE PAINT SPRAY BOOTH PROTECTION MANUAL

Design & Construction Standards, Revised January

SPECIFICATION MICROMIST FIRE SUPPRESSION SYSTEM WITH SHP-PRO CONTROL PANEL

VENTLESS EXHAUST HOOD OPERATORS MANUAL AND PARTS LIST REV. MAY 2016

Osceola County Department of Fire Rescue and Emergency Medical Services

ENGINEERING SPECIFICATIONS FOR FM-200 CLEAN AGENT INDIRECT PRE-ENGINEERED FIRE SUPPRESSION SYSTEMS

Data/ Specification Sheet

SECTION FM-200 FIRE SUPPRESSION SYSTEM

SPECIFICATION MICROMIST FIRE SUPPRESSION SYSTEM WITH CHEETAH Xi 50 CONTROL PANEL

Global Property. SEMIANNUAL FIRE PROTECTION EQUIPMENT INSPECTION REPORT Date of Inspection Location:

THE IDEAL SOLUTION FOR KITCHENS

Specification/ Data Sheet

D. Reference Standards (Utilize latest editions available):

The D1000. Typical Specifications: Standard Options*: Model: D1030-R Spec & Submittal Version 2.1 D1000-R_ D1000-R_-NFPA101

ICC CODE CORNER 2015 International Fire Code

60 Years of Commercial Kitchen Fire Suppression

The D1000. Typical Specifications: Standard Options*: Model: D1036-F Spec & Submittal Version 2.2 D1000-F_ D1000-F_-NFPA101

TWO TIMES THE FIGHT Twin-Agent Fire Suppression Systems

Basic Vehicle Fire Protection Manual

MAXIMUM KNOCKDOWN ABILITY Large Dry Chemical Fire Suppression Systems

SECURITY BLANKET Foam Fire Protection Products

2007 Fire Equipment Product Catalog

Industrial Dry Chemical Fire Suppression System

Kitchen Fire Suppression Systems Post-Event Analysis

Swiftclean and ANSUL. AXA s Commercial Kitchen Fire Safety Service. Ansul is a leading brand of Johnson Controls International PLC

COMMERCIAL KITCHEN FIRE SAFETY

TECHNICAL MANUAL OPERATOR'S, ORGANIZATIONAL AND DIRECT SUPPORT MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST)

IMO. Resolution A.951(23) Adopted on 5 December 2003 (Agenda item 17) IMPROVED GUIDELINES FOR MARINE PORTABLE FIRE EXTINGUISHERS

PORTABLE PERFORMANCE ANSUL Stored Pressure Fire Extinguishers

The Combustion Process THE FIRE TETRAHEDRON FUEL TEMPERATURE

SECTION COMMERCIAL-KITCHEN HOODS

DEPARTMENT OF LICENSING AND REGULATORY AFFAIRS DIRECTOR S OFFICE GENERAL INDUSTRY SAFETY STANDARDS PART 8. PORTABLE FIRE EXTINGUISHERS

Extinguishers. Commercial Industrial High rise buildings

GAS FLOODING SYSTEM FOR CIFF AT BASEMENT

CALIFORNIA DEPARTMENT of FORESTRY and FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL UL 300

Hospitals and Major Medical Centers

FIre Extinguishers. K-GUARD Wet Chemical Fire Extinguishers Manual INSTALLATION 2014-DEC-29 REV. 03 PAGE 1 EXTINGUISHERS

Fire Suppression Installation (R-102) for AVI Hoods & XLT Ovens

SPECIFICATION: ECS SERIES CLEAN AGENT FIRE SUPPRESSION SYSTEM

STORED PRESSURE YES TEST STANDARDS: CAN/ULC S504 & ANSI/UL 229 CAN/ULC S508 & ANSI/UL 711. Available Options: Stationary Design Tow Loop

TOTALPAC2 Integrated Fire Protection System

SPECIFICATION: Kidde Engineered Fire Suppression System Designed for use with 3M Novec 1230 Fire Protection

A. NFPA 2001 Standard for Clean Agent Fire Extinguishing Systems 2004 edition.

TotalPac X Single interlock SUREFIRE system

TotalPac X Firecycle III Preaction Double interlock system

SERVICE VERSUS REMOVAL OF OBSOLETE COMMERCIAL KITCHEN PRE-ENGINEERED FIRE SUPPRESSION SYSTEMS

KIDDE WHDR WET CHEMICAL FIRE SUPPRESSION AND INTELLIGENT CONTROL SYSTEM FOR COOKING OPERATIONS WITH ARIES-NET MULTI-LOOP INTELLIGENT CONTROL UNIT

XRRS Specification Fire Ready Hood

INDEPENDENT FIRE EXTINGUISHER SALES & SERVICES. Your First Line of Defense Since 1971

Ventless Operation Supplement GBF-D-VH

UNIVERSITY OF ROCHESTER ENVIRONMENTAL HEALTH & SAFETY

Dear Concessionaire,

MIST-A-FIRE SYSTEM OPERATORS MANUAL Mendell Davis Drive Jackson, MS , fax avtecind.com

DUST COLLECTION TRAINING. Revision 2013

Fire Safety Compliance

Badger Universal Control Head

CARBON DIOXIDE FIRE EXTINGUISHING SYSTEM

Service Bulletin No. 2930

Introduction to the Exhaust Fan Interceptor Commercial Exhaust Fans from a Service Perspective

READY FOR CHANGE. A Guide for Meeting the NFPA Compliance Standard for Portable Fire Extinguishers

Deluge & Preac tion Systems

BP U.S. Pipelines and Logistics (USPL) Safety Manual Page 1 of 6

PRICE BID. UNIT QTY Rate in Figure Rate in words Amount DESCRIPTION OF ITEM D: FIRE PROTECTION SYSTEM

SUPPRESSION SALES I INSTALLATION I SERVICE

F-CLASS MODEL M6L WET CHEMICAL FIRE EXTINGUISHER Installation, Operation, Recharge and Maintenance Manual

SPECIFICATION FOR A TOTAL FLOOD ECARO-25 TM CLEAN AGENT FIRE SUPPRESSION SYSTEM FOR USE WITH THE SHP PRO CONTROL PANEL SYSTEM

Transcription:

CORE Protection Fire System Specification The CORE restaurant fire suppression system is a pre-engineered, duct and plenum water spray system in conjunction with a wet chemical, cartridge-operated, regulated pressure type with a fixed nozzle agent distribution network. It is listed with ETL to UL Standard 300. The system is capable of automatic detection and actuation and/or remote manual actuation. The detection portion of the fire suppression system allows for automatic detection by means of an electric thermal detector located in the hood duct connection. The FSF103 Pull station is provided to allow for manual activation of the fire system. A microprocessor-based control board supervises all devices that are critical for proper operation. This includes the ductwork sensors, manual pull stations, cartridges and regulated releases. Also, the control board monitors all additional CORE protection system and will alert the user if any one device encounters an issue. With the electric fire detection, a battery backup system is provided. The battery powers the automatic detection and pull station circuits, as well as monitoring those devices. The basic system consists of an electric ANSUL AUTOMAN regulated release assembly, which includes a regulated release mechanism and a wet chemical storage tank housed within a single enclosure. Nozzle blow-off caps, cartridges and agent are supplied in separate packages in the quantities needed for fire suppression system arrangements. Tanks can be used in multiple arrangements to allow for larger hazard coverage. Each tank is limited to a listed maximum amount of flow numbers. The tank is constructed of stainless steel. A system owner's guide is available containing basic information pertaining to system operation and maintenance. A detailed technical manual is also available including system description, design, installation, recharge, and maintenance procedures, plus additional equipment installation and resetting instructions. The system is installed and serviced by authorized distributors that are trained by the manufacturer. Certifications The CORE Protection Fire System is ETL Listed under Report number 3132231SAT-004; meets requirements of NFPA 96 (Standard for the Installation of Equipment for the Removal of Smoke and Grease-Laden Vapors from Commercial Cooking Equipment); NFPA 17A (Standard on Wet Chemical Extinguishing Systems).

Suggested Specifications Duct and Plenum Spray Bar The spray bar extends the full length of the hood immediately behind the filters in the hood. The bar is ¾ brass fittings with nozzles that spray directly toward the back of the hood. Water enters the spray bar via a ¾ quick-seal. All fittings and pipe will be brass. Nozzle(s) covering the riser(s) will be ¼ NPT and is a wide angle, high flow nozzle. The first six feet of ductwork will be sprayed with the nozzle. The extinguishing agent for the duct and plenum is water injected with SC-5 surfactant. Electric Detection System with Battery Backup The detection and pull station for CORE comprise an electric circuit that is connected to a battery backup system. In the event of a power outage, the power to all gas and electric appliances must be disrupted through the use of electric gas valves or shunt trip breakers. The battery powers the automatic detection and pull station circuits, as well as monitoring those devices. Wet Chemical Agent and Tanks for Appliances The extinguishing agent is a potassium carbonate, potassium acetate-based formulation designed for rapid flame knockdown and foam securement of grease related fires. The agent tank is installed in a stainless steel enclosure or wall bracket. The tank is constructed of stainless steel. Tanks are available in two sizes: 1.5 gallon (5.7 L) and 3.0 gallon (11.4 L). The tanks have a working pressure of 110 psi (6.9 bar), a test pressure of 330 psi (20.7 bar), and a minimum burst pressure of 600 psi (41.4 bar). The tank includes an adaptor/tube assembly. The adaptor is chromeplated steel with a ¼-inch NPT female gas inlet and a 3/8-inch NPT female agent outlet. The adaptor also contains a bursting disc seal, which prevents the siphoning of agent up the pipe during extreme temperature variations. Regulated Release Mechanism When more than two agent tanks are required, the regulated actuator is available to provide expellant gas for additional tanks. It is connected to the cartridge receiver outlet of the regulated release mechanism providing simultaneous agent discharge. It contains a regulated actuator deadset at 100 psi (6.9 bar) with an internal relief of approximately 145 psi (10.0 bar). The regulated actuator assembly contains a regulated actuator, regulator, expellant gas hose, and agent tank housed in a stainless steel enclosure with cover. The enclosure contains knockouts to permit installation of the expellant gas line. Appliance Discharge Nozzle Each discharge nozzle is tested and listed with the R-102 system for a specific application. Nozzle tips are stamped with the flow number designation (1/2, 1, 2, and 3). Each nozzle must have a metal or rubber blow-off cap to keep the nozzle tip orifice free of cooking grease build-up. CORE Protection Fire System Timer The timer included in the electrical control package is energized when the fire system is activated. The fire system is activated either by the Firestat in the duct or a remote pull station. The timer holds the fire system duct and plenum protection on for a factory setting of 30 minutes. CORE Protection Firestat The Fenwal Firestat is a device installed in the hood s duct connection that measures temperature. The standard temperature setting is 360 F, but other temperature s are available. If a temperature higher then the set point is sensed, the Firestat contacts will close and energize the fire system.

Typical CORE Utility Cabinet End View QuickTime and a decompressor are needed to see this picture. Typical Wall Mounted CORE Control Cabinet View QuickTime and a decompressor are needed to see this picture.

CORE Firestat CORE Surfactant Tank

CORE Fire Protection System