Instructions for use Vacuum regulation valve with water trap

Similar documents
RVTM3 SUCTION VACUUM REGULATORS

Technical Datasheet. Suction Controllers, Flow Meters & Accessories

RVTM3 SUCTION VACUUM REGULATORS

MODEL 7000 SUCTION UNIT

Schuco byallied MEDICAL ASPIRATOR. USER'S MANUAL A Caution

The new mains-operated ATMOS respiratory tract suction devices in the reliable 26 l and 16 l class

Screw-in heater (EHK)

AS Medizintechnik GmbH Sattlerstrasse 15, Tuttlingen, Germany Tel 07461/ Fax 07461/

FTA-1 Aspirator with trap flask

OMNIVAC secretion aspiration system Description of device and instructions for use

ASPIRE Laboratory Aspirator

Surgical Suction: Silent and powerful!

Karlsruher Glastechnisches Werk KGW-ISOTHERM

Product overview Suction Guns, suction machines, Vac-Blast Cleaners

Operating / User Manual

Instruction Cum User Manual For EUROLITE

INSTRUCTIONS FOR CLEANING AND STERILIZATION OF ALL B.BRAUN AESCULAP HAND HELD SURGICAL INSTRUMENTS AND POWER PRODUCTS (UNITED KINGDOM REQUIREMENTS)

VarioVac vacuum regulators Consumables and Accessories

Specifications. Vacuum motor power consumption(w/hp) 1200 / 1.6. Exhaust water pump power consumption(w/hp 800 / 1.1

1 L Rotary Vacuum Evaporator Instruction Manual

MBWeich 100. Operating manual. 1. Introduction. 2. Use

Instruction Manual Spray Booth SK 66

Getz Equipment Innovators 450 lb Dual Portable Dry Chemical Fill System

OPERATION MANUAL. LED Coupling OM-TR355E. Please read this operation manual carefully and file for future reference.

I.F.U Re/Processing Reusable Medical Devices

CONSTANT SUCTION UNIT

PORTER INSTRUMENT COMPANY, INC. 245 TOWNSHIP LINE RD. P.O. BOX 907 HATFIELD, PA USA [215] / FAX [215]

SUCTION UNIT SUCTION UNIT

Short Instruction for Use for in-home care ASSKEA procuff M and ASSKEA procuff S

Söring Ultrasonic Generator Sonoca 300

EVAPORATIVE COOL MIST HUMIDIFIER Instruction Manual

1 Intended Use of the Breas HA 01 Humidifier

Instructions. Portable Absorb Phlegm. Apparatus

INSTRUCTIONS FOR USE & STERILIZATION FOR INSTRUMENTS

CBU144. Compact Booster Unit - single pump To ensure the quality of potable water according to EN1717. Product specification sheet

DIRECTIONS FOR USE. Keeping you insafehands to avoid needlestick injuries. see for demo video

Instructions for use. BA Optima. Air motors BA602 (BA640081) BA604 (BA640060)

Instructions for use. 301 plus

Important Safeguards. Topic 2 SAVE THESE INSTRUCTIONS - FOR HOUSEHOLD USE ONLY SAVE THESE INSTRUCTIONS - FOR HOUSEHOLD USE ONLY 3

Care instructions ESTETICA E80. Always be on the safe side.

Suction Pump F-30.xx

INSTRUCTIONS CertoClav EL

Remote alarm case VENTIremote alarm 10 m WM VENTIremote alarm 30 m WM Device description and instructions for use

SEPTIC FLUID ASPIRATOR MEDAP-VENTA SP 26 N MEDAP-VENTA SP 26 A

VarioAir Medical Suction Solutions Consumables and Accessories

HYDROCYCLONE ISO 18 INDEX. Page

O-PEP Hygiene-Beileger

3000W Pressure Washer RAC - HP006

DIRTY WATER SUBMERSIBLE PUMP

VAPORE 3000 ASPIRA IT IS RECOMMENDED TO CAREFULLY READ THE FOLLOWING MANUAL BEFORE USING THE MACHINE.

USER S MANUAL ATH WH220

Powerful universal suction devices for gynaecology and obstetrics. ATMOS S 351 Natal ATMOS C 451

AS Medizintechnik GmbH Sattlerstrasse 15, Tuttlingen, Germany Tel 07461/ Fax 07461/

Sip Vacuum Cleaner 1400/35 Wet & Dry

GEM-C Wireless User & Installation Manual. Revision October Apollo Solar Electric Limited. Documentation

Model # VWK-2 INSTRUCTION MANUAL

Operator s Guide. Autoclavable Internal Handles with Integrated Paddles Rev. M

FOR THE FOLLOWING MODELS: If you have any questions about the operation of your ultrasonic humidifier, please contact Crane Customer Care.

SERRES SUCTION BAG SYSTEM MANUAL

Integra Salto Talaris and Integra XT Non-Sterile Device Reprocessing. Instructions for Use. 4. Manual Cleaning Instructions

Lyovapor L-300 Technical data sheet

INFRARED IP55 HEATER INSTRUCTIONS FOR: MODEL:- QZWP45N 1. SAFETY INSTRUCTIONS

Aspirator with trap flask FTA-1

s l it l on for Infrared Heaters

Manual. Above-counter dispenser for hot drinks OTHG /12

INSTRUCTION MANUAL HETO CBN 8 / 18 / C Cooling Baths ID: IM.doc Revision 1

The most powerful allrounder

Waste water ejection unit

DIRTY WATER SUBMERSIBLE PUMP KIT

Xaact Spot. Xaact Hot Spot

Storm pets cylinder vacuum cleaner

OPERATING INSTRUCTIONS AND MAINTENANCE MANUAL

OPERATING INSTRUCTIONS AND MAINTENANCE MANUAL

DIGITAL Warm & Cool Mist Humidifier

CFS-2000 CHILLER TM. Operating Instructions P/N (110 VAC) P/N (230 VAC)

ADORABLE Ultrasonic Cool Mist Humidifier

FUNCTION DESCRIPTION. Air - Humidifier / Air - Washer

Operating manual UNIQUE UNIQUE [HAZER]

RONDA 2-58 Duo Heavy Duty Industrial Vacuum Cleaner For Liquid Filtration and Transport

SURGICAL ASPIRATOR FOR THE OPERATING THEATRE MEDAP-TWISTA SP 1070

AS Medizintechnik GmbH Sattlerstrasse 15, Tuttlingen, Germany Tel 07461/ Fax 07461/

A basic introduction about the principles of humidity

INSTRUCTION- AND MAINTENANCE MANUAL FOR ELECTROMAGNETIC AIR PUMP JDK-60, JDK-80, JDK-100, JDK-120

THE MEDIX Actineb. Technical Specifications. % Particles < 5 um 75% * Class II BF. Intermittent (use for 60 Type Rating

Suction unit Victoria

OWNER S MANUAL FOR AIR ADMIRAL VACUUM/PRESSURE STATION MODELS:

INSTALLATION INSTRUCTIONS TXV Horizontal Slab Coils WLSH

Cleaning & Care. Washing Breast Pump Parts

PIPELESS WHIRLPOOL FOOT BATH OWNER S MANUAL. Model: FB2-S115

BEFORE OPERATING THE MACHINE: WARNING

X99 Series. Dental Handpiece. Instruction For Use

DISPOSABLE CONTAINERS FOR SUCTION APPLICATIONS FLOVAC CONTAINER WITH MECHANICAL VALVE

Accessories. Maybachstraße. Symmetry Fax: Revised 10/15

RENZ FOR QUALITY PRODUCT CATALOGUE.

2500 Electric Blower Vac

OPERATIONAL & INSTRUCTION MANUAL. Model: 2400FA (120v 1Ø) Model: 3200FA (220v-240V 1Ø) Voltage Supply to Machine:

HANDS-ON MODULE 5. CLEANING FLOW-i V3.0

Tropic 2.0 ultrasonic nebuliser

Gas Fire Patio Heater Q9

AIR OPERATED CLUTCH & BRAKE BLEEDING KIT. MODEL NO: CHT637 Part No: OPERATING & MAINTENANCE INSTRUCTIONS GC01/12

Transcription:

Instructions for use Vacuum regulation valve with water trap

Table of Contents Introduction 1. Description of Functions 2. Putting into Operation 3. Instructions for Cleaning and Care 3.1 Disassembling 3.2 Disinfection and Cleaning 3.2.1 Manual Disinfection and Cleaning 3.2.2 Mechanical Disinfection and Cleaning 3.3 Sterilisation 4. Technical Data 5. Spare Parts 6. Customer Service / Warranty / Maintenance 7. Manufacturer s Data Seite 2 von 16

INTRODUCTION These instructions for use are meant to support you to operate the outlet systems for vacuum. In addition, you will find a description of the various options available to combine the products with different systems. If any failures or questions should come up during service please do not hesitate to contact our customer service department for help.. 1. DESCRIPTION OF FUNCTIONS and MODELS The vacuum regulation valve with water trap combined with a collecting device has been designed for secretion removal by suction over a longer period of time. In addition, this system allows for the very precise and consistent adjustment of small vacuums and the competent, professional application of a secretion removal system by suction. By means of the vacuum regulator, the vacuum available from the central supply system is adjusted to the vacuum value required. Depending on the setting of the infinitely variable regulating valve, this suction is capable of generating a vacuum between 0 and -0.8 bar. This vacuum is limited by the immersion depth of the immersion tube in the water trap. Seite 3 von 16

The maximum immersion depth is 40 cm. This corresponds to a maximum vacuum of 0.04 bar. - water column of 1 cm = 0.001 bar = 1 mbar When the resistance of the secretion rises the vacuum increases as well and the atmospheric pressure of the surrounding presses the water level in the immersion tube more and more under the water level in the bottle. The difference in height (h) of the two water levels in cm corresponds to the currently generated negative pressure in mbar. When the water level in the immersion tube reaches the lowest end (h max.) air escapes through the immersion tube and goes up in the form of air bubbles. This prevents the vacuum from increasing more and it is limited. Due to the fact that the position of the immersion tube can be modified in its height, different limiting positions may be chosen, i.e. it is possible to infinitely adjust different vacuums. Illustr. 1: System plan Seite 4 von 16

The vacuum regulation valve with water trap is available in the following designs: Vacuum regulation valve for direct connection to the vacuum outlet Article No.: 623-0330 The vacuum regulation valve comes equipped with a connector standardised for this particular gas. Vacuum regulation valve for wall rail with NIST screw joints Article No.: 623-0320 The vacuum regulation valve is connected to the medical gas supply by means of a gas-type coded connecting hose. Seite 5 von 16

Accessories required Vac connecting hose for vacuum regulation valve with water trap rail ISO 6600127 / Neutral 6600126 Accessories recommended for vacuum regulation valve direct and rail Illustr.: Suction set with finger tip and bacteria filter 606-2400 Bacteria filter In order to avoid contamination, the bacteria filter has to be installed between the vacuum regulation valve and the secretion-collecting jar. Secretion-collecting jar The secretion which has been sucked off is collected in the secretioncollecting jar which has been equipped with a float ball to prevent it from overflowing. Once the maximum filling height has been reached, this float ball will lock the connection to the vacuum-regulation valve. Seite 6 von 16

The following secretion-collecting jars may be connected: Secretion-collecting jar 1.0 l Rail 6600255 Secretion-collecting jar 1.0 l Jar-carrying rack 6600265 Carrying rack for secretioncollecting jar 1.0 l 6600260 Illustr. Size 2.0 l 6231000 Also available in Size 1.0 l 6231050 Size 3.0 l 6231060 Secretion-collecting jar with bayonet joint The scaling on all secretion-collecting jars is only meant as an approximate value without measuring function. Alternatively, disposable collecting jars may be used. Seite 7 von 16

Immersion tube Clamp screw for immersion tube Hose adapter for secretion-collecting jar Regulating unit Collecting jar with scaling for negative pressure Seite 8 von 16

2. PUTTING INTO OPERATION of vacuum regulation valve with water trap Please make sure that all the components connected, i.e. connecting hose, drainage systems, bacteria filter, safety jar, secretion-collecting jar etc., have been properly and firmly adapted. Screw off the collecting jar and fill it with distilled water up to the marking maximum filling height. Before putting into operation, place the immersion tube with the lower edge onto the marking of the vacuum that you require. The position of the immersion tube is fixed by means of the clamp screw. Please make sure that the clamp screw has been fastened properly. The suction power is set by opening the regulating valve. This process will open the vacuum flow and create the undertow required for suction. Turn the regulating unit anti-clockwise until with closed suction connector air bubbles can be seen at the lower end of the immersion tube. This means that the preset negative pressure has been reached. In order to avoid contamination, a bacteria filter has to be installed between the vacuum regulation valve and the secretion-collecting jar. Seite 9 von 16

Before putting the system into operation, a function test should be carried out in accordance with the following schedule: Connect the vacuum regulation valve with the outlet Fill the collecting jar Set the lower edge of the immersion tube to the marking 5 mbar Open the regulating unit completely (by turning anti-clockwise until reaching the stop) Please make sure that, with an open hose adapter, there are no air bubbles at the end of the immersion tube. Close the regulating unit completely (by turning clockwise until reaching the stop). Please make sure that, with a closed hose adapter, there are no air bubbles at the end of the immersion tube. In the case of a negative test result, please urgently correct the failure yourself or contact our service department. Make sure that the apparatus is not put into operation. Seite 10 von 16

recommended Drainage system Seite 11 von 16

3. INSTRUCTIONS FOR CLEANING AND CARE 3.1 Disassembling For disinfection, cleaning or sterilisation purposes, screw off the bottle and empty it. Attention: Do not autoclave the collecting jar at 134 C. Do not sterilise the sound absorber. 3.2 Disinfection and cleaning 3.2.1 Manual disinfection and cleaning All those parts which get in contact with the patients breathing air have to be disinfected in any case. Put the corresponding application elements into the disinfecting bath; the exposure time will depend on the type of disinfecting agent which is used (see the package insert of the disinfectant). Take the elements out of the disinfecting bath and rinse them with running sterile water. Dry the cleaned elements. Please make sure that there is no humidity left in the apparatus. For those parts which do not get into contact with the patients breathing air wiping disinfection will be sufficient 3.2.2 Mechanical disinfection and cleaning Please make sure that you only use non-aggressive detergents, for example neo disher MA, neo disher FA or similar products. 3.3. Sterilisation Disposable application elements must not be autoclaved (see order data). Seite 12 von 16

4. Technical Data Vacuum regulation valve with water trap Direct Vacuum regulation valve with water trap Rail Article No.:: 6230330 6230320 Control range 0 to 40 mbar Suction power Material Anodized aluminium / Stainless steel Connection Connector acc. to DIN 13260-2 1) NIST screw joints Fastening ---------------------- Exit Hose adapter for silicone hose 6 x 2 H x W x D mm For device-holding rail 25 x 10 mm 2) 710 x 140 x 180 710 x 140 x 160 Weight 1,400 g 165 g Accessories Art. No. Accessories Art. No.. 1) Various other connections, e.g. BS, AFNOR or AGA available 2) Also available for other rail dimensions See pages 6 to 7 Connecting hose AIR 1.5 mtr DIN 1) - NIST ISO 660-0117 / Neutral 660-0116 Seite 13 von 16

5 Spare Parts Illustration Designation of article Article number Immersion tube with O-ring 043-2330 O-ring for immersion tube 17 x 2 mm 049-3232 Flat gasket for collecting jar 037-1340 Collecting jar complete 019-2510 Clamping ring 043-3211 O-ring for clamping ring 8 x 2 mm 049-3020 No illustration Filter insert water trap 1570130 Seite 14 von 16

6. CUSTOMER SERVICE / WARRANTY / MAINTENANCE The period of warranty for the equipment is 12 months starting from the date of sale in accordance with the following conditions: During the period of warranty, we will eliminate, free of charge, any damage or failures of the equipment caused by verifiable faults in production or in the material, provided that these failures have been reported without delay after detection. Deviating from this, the warranty for engines of any type, compressors, electric switching devices, semiconductor elements, electric displays and measuring equipment is six months. This warranty is not applicable to fragile parts made of glass, for example, or consumable and wearing parts, e.g. filters. In the case of a guarantee, the decision of whether to repair or exchange the equipment will be at our own option. Cases of guarantee will neither extend the period of warranty nor will they represent the start of a new period of warranty. Spare parts which are installed will not be subject to an individual period of warranty. Any damage caused by improper use, faulty operation, mechanical damage or nonobservance of the instructions for use as well as any damage caused by force majeure or any other unusual environmental conditions will not be covered by the warranty. The warranty claim will expire when interventions, changes or repairs of the equipment have been carried out by people who have not been authorised by us to do so or when the equipment has been used with additional accessories or spare parts of strange origin. The faulty equipment has to be sent in its original packaging - to the address mentioned below with carriage and postage paid. Further claims as well as any so-called consequential damage will be excluded as long as liability is not required by law. Equipment may be subject to technical changes without notice! Maintenance The flawless condition and proper functioning of all the silicone seals in the equipment have to be checked once a year and to be replaced if necessary. Also once a year, the system has to be checked for damage and improper functioning. Seite 15 von 16

7 Manufacturer s Data Manufacturer: Heyer Aerotech GmbH Nieverner Straße 30 D - 56132 Nievern Tel.: +49 (0)2603-2004 Fax: +49 (0)2603-4020 E-Mail: office@heyer-aerotech.de Homepage: www.heyer-aerotech.de Sales office: Heyer Aerotech GmbH Nieverner Straße 30 D - 56132 Nievern Tel.: +49 (0)2603-2004 Fax: +49 (0)2603-4020 E-Mail: office@heyer-aerotech.de Homepage: www.heyer-aerotech.de Rev. 2.1 as per 01 June 2010 Seite 16 von 16