Field Installed Options: * Louvered or non-louvered ceiling access panels. * Time delay relay.

Similar documents
DEDICATED VERTICAL/WALL MOUNT

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

DH SERIES HORIZONTAL DIRECT DRIVE CHILLED WATER/DX AIR UNITS. OPTIONAL ACCESSORIES Two Row Hot Water Coil

Product Data. FF1DNA, FF1DNE Fan Coil Units. Sizes 018 thru 030 FEATURES/BENEFITS

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series

Fan Coils & Air Handlers Product Catalog

MX Series Indoor Modular Blowers Electric Heat, Hot Water Heat, or No Heat

Product Specifications NEW OPTION AVAILABLE: AUTOSPEED 24V CONTROL PACKAGE

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH

Product Specifications NEW OPTION AVAILABLE: AUTOSPEED 24V CONTROL PACKAGE

INSTALLATION AND OWNERS MANUAL

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D

MH1WC4W-06-1-B Chilled/Hot Water 1-Way Cassette Fan Coil

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

MHWW-24-H-1 Chilled/Hot Water Hi-Wall Fan Coil 2-Pipe Heat / Cool Fan Coil 24,000 BTUH

MHWW-09-H-1 Chilled/Hot Water Hi-Wall Fan Coil 2-Pipe Heat / Cool Fan Coil 9,000 BTUH

CWA2 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000-60,000 BTUH

TECHNICAL GUIDE HIGH EFFICIENCY, STANDARD ECM VERTICAL WALL MOUNT AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: EWX*18-36

PAJ3. Product Specifications

ACNF Series. Ceiling-Mount Air Handlers 1½ to 2½ Tons

The Premium Quality Fan Coil Units for Vertical, Horizontal (Left or Right) Application with Direct Expansion, Hydronic or Electric Heat

CFFWA4P-16-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 48,000 BTUH

CFFWA4P-12-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 36,000 BTUH

maintenance should only be performed by a trained, qualified person. Consumer service is recommended only for filter replacement.

CFFWA4P-08-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 24,000 BTUH

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

AEPF. 1½ to 5 Tons. Contents Nomenclature... 2 Product Specifications... 3 Dimensions... 4 Wiring Diagram... 6 Accessories... 7

PC SERIES 50 Hertz PRODUCT SPECIFICATIONS. Self-Contained Packaged Air Conditioners. 4 and 5 Ton [14.1 kw to 17.6 kw]

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

Cooling/Heat Pump Convertible Air Handlers

WAHL A Product Specifications

ADPF PRODUCT SPECIFICATIONS THREE-SPEED AIR HANDLER 1½ TO 5 TON DEDICATED DOWNFLOW

CWA4 Chilled & Hot Water Fan Coil

Technical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ)

COMMERCIAL PACKAGED HEAT PUMP AIR HANDLER UNITS, 6 20 TONS

PAD3. Product Specifications. 13 SEER PACKAGE AIR CONDITIONER, 2 to 5 TONS Single Phase, 208/230 V, 60 Hz REFRIGERATION CIRCUIT

14 SEER, 12 EER, 8.0 HSPF, PACKAGE HEAT PUMP, 2 to 5 TONS 208/ , Single Phase

Product Data. 50EES--ZP (50Hz) Single Package Air Conditioners 3-5 Nominal Tons

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

WPH4 Product Specifications

MHCFC4W Chilled/Hot Water Cassette Fan Coil

MHCFC4W Chilled/Hot Water Cassette Fan Coil

MHCFC4W Chilled/Hot Water Cassette Fan Coil

FEM4X. Product Specifications FAN COILS /14/15

14 SEER, 12 EER, 8.0 HSPF, PACKAGE HEAT PUMP, 2.5 to 5 TONS 208/ , Operating Model Number

Product Data. FPMA Sizes 018 thru 036 FPMB Sizes 018 thru 030 Base Series Horizontal Fan Coil

INSTALLATION & OPERATING INSTRUCTIONS AEM SERIES VARIABLE SPEED MULTI-POSITION ELECTRIC HEAT AIR HANDLER

PARTS LISTS GAS/T... 1 GAW... 3 GBS/T... 5 GES/T... 6 GFS/T... 8 GFW... 9

Ameristar SUBMITTAL M4AH4E26B1A00AA. 2.0 Ton Multi-position Air Handler M4AH4E26B1A00AA TAG:

Cooling/Heat Pump Convertible Air Handlers

Product Data FEATURES/BENEFITS. 524J PACKAGED AIR -HANDLING UNITS WITH PURONr REFRIGERANT SIZES 07, 08, 12, 14, 16. Indoor air quality features

SPXB-HW Series Single Package Vertical Unit Cooling with Hot Water Heat 1 through 2 tons, up to 47,800 BTUH Heating

36,000-62,000 BTUH Nominal Capacity

Commercial High-Efficiency Condensing Units

Product Data. Features/Benefits. 40QKB024,036 40QKE024,036,048 Cooling Only and Heat Pump In-Ceiling Cassettes. 2to4NominalTons

Models PF1A PF1B PACKAGED AIR-HANDLING UNITS. 6to10Tons. Form No. PDS PF1A.72.1 FEATURES/BENEFITS

15 SEER, PACKAGE AIR CONDITIONING UNITS, 2-5 TONS Single Phase, 208/230 V, 60 Hz COOLING

ARPT Series. Multi-Position. 1½ to 5 Tons. Internal TXV, Multi-Speed PSC Motor

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

Product Data. 50ZPB Single---Packaged Air Conditioner System With R---410A Refrigerant Single Phase 2 to 5 Nominal Tons (Sizes )

BCE4 PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER WITH VARIABLE SPEED APPLICATION INSTALLATION CABINET COMPONENTS CONTROLS WARRANTY

Product Data. 50ZP (60Hz) Single-Package. Air Conditioners 3-5 Nominal Tons

CB18/CBS18 Bulletin # September 1994 Supersedes August 1986

PHD3. Product Specifications

Product Data FEATURES/BENEFITS 524J***H 6 TO 20 TON DIRECT EXPANSION PACKAGED HEAT PUMP AIR -HANDLING UNIT. Indoor air quality features 524J-H 07-12

EER PACKAGE AIR CONDITIONER, 6.9 to 14.4 kw, 2 4 TONS 3 Phase, Standard CFM / Ls EER

REM4P, REM4X. Product Specifications

157 (71) 3-1/ (661) 49 5/8 x 21 1/8 x 22 1/16 (1261 x 537 x 560) 19 7/8 x 21 1/2 (505 x 546) FSM4P4200AL 156 (71) FEM4P4800AL

C13-Series Engineering Guide

PAR5. Product Specifications

WJH4 Product Specifications

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units

FXM4X. Product Specifications FAN COILS FXM4X

Product Data. 50ZP Single-Package Air Conditioners. 2 to 5 Tons

AEPT SERIES PRODUCT SPECIFICATIONS. Multi-Position Air Handler. 2 to 5 Ton

49 5/8 x 17 5/8 x 22 1/16 (1261 x 448 x 560) 49 5/8 x 17 5/8 x 22 1/16 (1261 x 448 x 560) 53 7/16 x 21 1/8 x 22 1/16 (1357 x 537 x 560)

Product Data. FV4B Direct Expansion Variable Speed Fan Coil Puron Refrigerant. Sizes 002 thru 006

2TEH3F18A1000A 2TEH3F24A1000A 2TEH3F30A1000A 2TEH3F36A1000A 2TEH3F42A1000A 2TEH3F48A1000A 2TEH3F60A1000A 1½

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

CATALOG. SKYPAK Self-Contained Heating/Cooling Units

Technical Development Program

WITH HOT WATER HEAT 2 THRU 5 TONS SPLIT SYSTEM AHXW Series

Product Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons

Product Data. PA4Z SINGLE -PACKAGED AIR CONDITIONER SYSTEM WITH PURONr (R -410A) REFRIGERANT SINGLE PAHSE 2 TO 5 NOMINAL TONS (SIZES )

BAC / BHC SERIES 7-1/2 to 20 Ton Air Handlers

ISERIES VERTICAL AHU ENGINEERING SPECIFICATIONS

Cooling/Heat Pump Convertible Air Handlers

Data Aire LCS TM (Large Ceiling System) R-407C. 6, 8, 10, and 13 ton. ISO 9001 Certified

VertiCool Aurora Engineering Guide

Split System Heat Pump Product Data

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

Product Data PF4MNB DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 019 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES:

VERSECON Indoor Vertical Self-Contained Air Conditioner YSWU Ton Water-Cooled

ASUF Series. Multi-Position. Air Handler 1½ to 5 Tons

TECHNICAL SPECIFICATIONS

49 x 21 x 22. (1261 x 448 x 560) (1261 x 448 x 560) 59 x 24 x 22. (1357 x 537 x 560) (1261 x 537 x 560) (1261 x 537 x 560) (1357 x 627 x 560)

Data Aire Mini Ceiling Systems 1, 1.5, 2, and 2.5 ton capacities R-410A. ISO 9001 Certified

Product Data. 50ZHB 13 SEER Single--Packaged Heat Pump System with Puronr (R-- 410A) Refrigerant Single Phase 2 to 5 Nominal Tons ( )

Transcription:

Description: These air handlers are designed for horizontal mounting into a furred down ceiling, and will handle up to 1150 CFM and up to 3 ton of cooling with a DX cooling or heat pump coil, or Chilled Water coil. These units will provide up to 10 KW of electric heat or up to 51,000 MBTUH of hot water heating. For DX cooling requirements these air handlers can be matched with most manufacturer's condensing units and heat pumps. The "S" series air handlers are exposed blower type, and the "C" series is equipped with an insulated cabinet over the top and sides. The bottom of the case is open to accomidate a louvered/filtered access panel. The cased units have a knock-out for rear return air. Return air duct flanges and filter racks are field supplied Standard Features: * Electric heat models are 208/230/1/60. * Hot water heat models are 115/1/60. * Water circulating pump is factory installed on hot water heat models. * Space saving design. * Galvanized steel blower wheels. * Prewired for cooling and heating. * Control transformer. * Primary and secondary condensate drain pans. * Easy access for service and maintenance. * High efficeince copper tubs aluminum fin coils. Field Installed Options: * Louvered or non-louvered ceiling access panels. * Time delay relay. Factory Installed Options: * Thermostatic expansion valve, either R-22 or R-410A, all expansion valves are suitable for heat pump application. * Deduct for removing hot water circulating pump for boiler loop applications. Form: SEHX/070106-1

Series S-Uncased C-Cased UNIT NOMENCLATURE S EHX 24 10 0 7 O C 62 Type EHX CWE DXW CWW Capacity Nominal Cooling BTUH Nominal Heating Capacity Electric Expressed in KW HW Expressed in BTUH Expansion Device Code (DX Coil) 0 - Orifice/Piston E - TXV (Non-Bleed) Orifice or TXV Code DX Coil) 7 - # 47 Orifice A - # 49 Orifice (or) "A" TXV) E - # 55 Orifice 9 - # 59 Orifice H - # 61 Orifice J - # 63 Orifice 5 - # 65 Orifice K - # 68 Orifice 1 - @ 71 Orifice B- "B" TXV Time Delay Relay O - Without TDR (Standard) 1 - With TDR (Option) Unit Voltage A - 115/1/60 C - 208/230/1/60 Motor & Fan Wheel Code 62-1/10 HP 208/240 (2) 6.25X6.88 64-1/6 HP 208/240 (2) 6.25X6.88 65-1/4 HP 208/240 (2) 6.25X8.00 67-1/10 HP 115 (2) 6.25X6.88 69-1/6 HP 115 (2) 6.25X6.88 70-1/4 HP 115 (2) 6.25X8.00 Form: SEHX/070106-2

PRODUCT NOMENCLATURE EVAPORATOR COIL C F 030 S D6B COIL C = Cooling/Heat Pump TYPE S = Slant Coil NOMINAL CAPACITY 18 = 18000 BTUH 24 = 24000 BTUH 30 = 30000 BTUH 36 = 36000 BTUH SLAB CONFIGURATION S = 1 Slab (Single Slab Coil) SLAB CODE Factory Use Form: SEHX/070106-3

SEHX / CEHX SCWE / CCWE -18-XX-0A-0C64-19-XX-0E-0C64-24-XX-09-0C64-25-XX-0H-0C65-30-XX-0J-0C65-31-XX-05-0C65-34-XX-0K-0C65-35-XX-01-0C65-36-XX-0K-0C65-37-XX-01-0C65 FAN DATA Motor CFM @ External Static Pressure HP 0.00" 0.05" 0.10" 0.15" 0.20" 0.25" 0.30" 1/6 810 785 765 740 720 700 680 1/6 910 880 855 830 805 785 765 1/6 950 920 890 875 850 825 805 1/4 1160 1130 1100 1070 1040 1020 985 1/4 1180 1145 1115 1085 1055 1025 1000 1/4 1160 1130 1100 1070 1040 1020 985 1/4 1256 1212 1172 1133 1084 1059 1029 1/4 1216 1172 1138 1108 1049 1024 995 1/4 1275 1230 1190 1150 1100 1075 1045 1/4 1235 1190 1155 1125 1065 1040 1010 SDXW / CDXW SCWW / CCWW -18-21-0A-0C69-19-21-0E-0C69-24-23-09-0C69-25-23-0H-0C69-30-27-0J-0C70-31-28-05-0C70-34-30-0K-0C70-35-30-0K-0C70-36-32-0K-0C70-37-32-0K-0C70 FAN DATA Motor CFM @ External Static Pressure HP 0.00" 0.05" 0.10" 0.15" 0.20" 0.25" 0.30" 1/6 794 769 750 725 706 686 666 1/6 892 862 838 813 789 769 750 1/6 931 902 872 858 833 809 789 1/4 1137 1107 1078 1049 1019 1000 965 1/4 1156 1122 1093 1063 1034 1005 980 1/4 1137 1107 1078 1049 1019 1000 965 1/4 1231 1188 1149 1110 1062 1038 1008 1/4 1192 1149 1115 1086 1028 1004 975 1/4 1250 1205 1166 1127 1078 1054 1024 1/4 1210 1166 1132 1103 1044 1019 990 Form: SEHX/070106-4

Physical Data: Model Motor HP DX CW HW Suction Liquid CW HW Shp. No. HP Rows Rows Rows Conn. Conn. Conn. Conn. Wght. SEHX & CEHX Series DX Cooling Electric Heat 18 1/6 3 N/A N/A 3/4 3/8 N/A N/A 60 19 1/6 4 N/A N/A 3/4 3/8 N/A N/A 65 24 1/6 3 N/A N/A 3/4 3/8 N/A N/A 60 25 1/4 4 N/A N/A 3/4 3/8 N/A N/A 75 30 1/4 3 N/A N/A 3/4 3/8 N/A N/A 70 31 1/4 4 N/A N/A 3/4 3/8 N/A N/A 75 34 1/4 3 N/A N/A 3/4 3/8 N/A N/A 74 35 1/4 4 N/A N/A 3/4 3/8 N/A N/A 80 36 1/4 3 N/A N/A 3/4 3/8 N/A N/A 85 37 1/4 4 N/A N/A 3/4 3/8 N/A N/A 90 SDXW & CDXW Series DX Cooling Hot Water Heat 18 1/6 3 N/A 2 3/4 3/8 N/A 5/8 64 19 1/6 4 N/A 2 3/4 3/8 N/A 5/8 69 24 1/6 3 N/A 2 3/4 3/8 N/A 5/8 64 25 1/4 4 N/A 2 3/4 3/8 N/A 5/8 79 30 1/4 3 N/A 2 3/4 3/8 N/A 5/8 74 31 1/4 4 N/A 2 3/4 3/8 N/A 5/8 79 34 1/4 3 N/A 2 3/4 3/8 N/A 5/8 78 35 1/4 4 N/A 2 3/4 3/8 N/A 5/8 84 36 1/4 3 N/A 2 3/4 3/8 N/A 5/8 89 37 1/4 4 N/A 2 3/4 3/8 N/A 5/8 94 SCWE & CCWE Series Chilled Water Cooling Electric Heat 18 1/6 N/A 4 N/A N/A N/A 5/8 N/A 65 19 1/6 N/A 5 N/A N/A N/A 5/8 N/A 70 24 1/6 N/A 4 N/A N/A N/A 5/8 N/A 65 25 1/4 N/A 5 N/A N/A N/A 5/8 N/A 80 30 1/4 N/A 4 N/A N/A N/A 5/8 N/A 75 31 1/4 N/A 5 N/A N/A N/A 5/8 N/A 80 34 1/4 N/A 4 N/A N/A N/A 5/8 N/A 79 35 1/4 N/A 5 N/A N/A N/A 5/8 N/A 85 36 1/4 N/A 4 N/A N/A N/A 5/8 N/A 90 37 1/4 N/A 5 N/A N/A N/A 5/8 N/A 95 SCWW & CCWW Series Chilled Water Cooling Hot Water Heat 18 1/6 N/A 4 2 N/A N/A 5/8 5/8 67 19 1/6 N/A 5 2 N/A N/A 5/8 5/8 72 24 1/6 N/A 4 2 N/A N/A 5/8 5/8 67 25 1/4 N/A 5 2 N/A N/A 5/8 5/8 82 30 1/4 N/A 4 2 N/A N/A 5/8 5/8 77 31 1/4 N/A 5 2 N/A N/A 5/8 5/8 82 34 1/4 N/A 4 2 N/A N/A 5/8 5/8 81 35 1/4 N/A 5 2 N/A N/A 5/8 5/8 87 36 1/4 N/A 4 2 N/A N/A 5/8 5/8 92 37 1/4 N/A 5 2 N/A N/A 5/8 5/8 97 Form: SEHX/070106-5

PERFORMANCE & ELECTRICAL DATA (ELECTRIC HEAT) Model Number Electric Heat Nominal Nominal Capacity (BTUH) @ 230/1/60 KW @ KW @ Tons CFM 230/1 208/1 230/1 208/1 MCA * MOCP 0 0 0 0 2.5 10.0 3.0 2.3 10245 7684 18.0 20.0 SEHX/CEHX-18,19 5.0 3.8 17075 12806 28.0 30.0 1.5 600 SCWE/CCWE-18,19 6.0 4.5 20490 15368 33.0 40.0 8.0 6.0 27320 20490 43.0 45.0 10.0 7.5 34150 25613 55.0 60.0 0 0 0 0 2.5 10.0 3.0 2.3 10245 7684 18.0 20.0 SEHX/CEHX-24 5.0 3.8 17075 12806 28.0 30.0 2.0 800 SCWE/CCWE-24 6.0 4.5 20490 15368 33.0 40.0 8.0 6.0 27320 20490 43.0 45.0 10.0 7.5 34150 25613 55.0 60.0 0 0 0 0 2.5 10.0 3.0 2.3 10245 7684 18.0 20.0 SEHX/CEHX-25,30,31 5.0 3.8 17075 12806 28.0 30.0 2.5 1000 SCWE/CCWE-25,30,31 6.0 4.5 20490 15368 33.0 40.0 8.0 6.0 27320 20490 43.0 45.0 10.0 7.5 34150 25613 55.0 60.0 0 0 0 0 3.8 15.0 3.0 2.3 10245 7684 19.0 20.0 SEHX/CEHX-34,35 5.0 3.8 17075 12806 29.0 30.0 3.0 1100 SCWE/CCWE-34,35 6.0 4.5 20490 15368 35.0 40.0 8.0 6.0 27320 20490 45.0 45.0 10.0 7.5 34150 25613 55.0 60.0 0 0 0 0 3.8 15.0 3.0 2.3 10245 7684 19.0 20.0 SEHX/CEHX-36,37 5.0 3.8 17075 12806 29.0 30.0 3.0 1200 SCWE/CCWE-36,37 6.0 4.5 20490 15368 35.0 40.0 8.0 6.0 27320 20490 45.0 45.0 10.0 7.5 34150 25613 55.0 60.0 * Amp Ratings @ 240/1/60 - Derate 25% for 208/1/60 PERFORMANCE & ELECTRICAL DATA (HOT WATER HEAT) Hot Water Heating Model Number SDXW/CDXW SCWW/CCWW -18-21-0A-0C69-19-21-0E-0C69-24-23-09-0C69-25-23-0H-0C69-30-27-0J-0C70-31-28-05-0C70-34-30-0K-0C70-35-30-0K-0C70-36-32-0K-0C70-37-32-0K-0C70 Nominal Tons Nominal CFM HORIZONTAL CEILING MOUNTEDAIR HANDLER FLA @ 115/1 MCA @ 115/1 MOCP @ 115/1 Capacity 1.5 680 21,000 2.32 2.0 15 1.5 765 21,000 2.42 3.0 15 2.0 805 23,000 2.42 3.0 15 2.5 985 23,000 2.42 3.0 15 2.5 1000 27,000 3.82 4.8 15 2.5 985 28,000 3.82 4.8 15 3.0 1029 30,000 3.82 4.8 15 3.0 995 30,000 3.82 4.8 15 3.0 1045 32,000 3.82 4.8 15 3.0 1010 32,000 3.82 4.8 15 Form: SEHX/070106-6

Model Number SCWE/CCWE18 SCWW/CCWW18 SCWE/CCWE19 SCWW/CCWW19 SCWE/CCWE24 SCWW/CCWW24 SCWE/CCWE25 SCWW/CCWW25 SCWE/CCWE30 SCWW/CCWW30 SCWE/CCWE31 SCWW/CCWW31 SCWE/CCWE34 SCWW/CCWW34 SCWE/CCWE35 SCWW/CCWW35 SCWE/CCWE36 SCWW/CCWW36 SCWE/CCWE37 SCWW/CCWW37 CHILLED WATER COOLING CAPACITY Cooling Capacity @ E.W.T. PD Water PD Air CFM GPM 80 F / 67 F / 45 F 80 F / 67 F / 42 F (Ft.Wtr) (IWC) Total Sensible Total Sensible 2.0 14,700 12,900 15,800 13,400 1.2 3.0 18,100 14,600 19,700 15,300 2.6 600 4.0 20,600 15,800 22,700 16,600 4.4 0.29" 5.0 22,600 16,700 25,000 17,600 6.8 6.0 24,200 17,300 26,882 18,400 9.6 2.0 17,900 14,500 19,400 15,000 2.1 3.0 21,500 16,000 23,500 16,900 4.6 600 4.0 24,100 17,100 26,600 18,200 7.9 0.35" 5.0 26,000 17,900 28,300 19,100 12.0 6.0 27,400 18,500 30,600 19,900 17.0 2.0 16,400 15,000 17,500 15,800 1.2 3.0 20,400 17,500 22,100 18,300 2.6 800 4.0 23,500 19,000 26,000 20,000 4.4 0.44" 5.0 25,800 20,100 28,300 21,200 6.8 6.0 27,700 21,000 30,600 22,200 9.7 2.0 20,300 17,200 21,800 18,000 2.1 3.0 24,700 19,500 26,750 20,400 4.6 800 4.0 27,800 20,900 30,500 22,000 7.9 0.55" 5.0 30,300 22,000 33,300 23,300 12.0 6.0 32,100 22,800 35,600 24,300 17.0 2.0 19,500 17,800 20,800 18,700 1.3 3.0 24,500 21,200 26,500 22,200 2.8 1000 4.0 28,300 23,200 30,700 24,300 4.9 0.40" 5.0 31,200 24,600 34,190 25,900 7.5 6.0 33,800 25,700 37,000 27,200 10.6 2.0 24,300 20,500 25,800 21,400 2.4 3.0 29,600 23,600 31,800 24,700 5.2 1000 4.0 33,500 25,500 36,300 26,800 9.0 0.53" 5.0 36,500 26,900 40,000 28,400 13.6 6.0 38,800 27,900 42,900 29,700 19.2 2.0 20,900 19,100 22,400 20,100 1.4 3.0 26,500 22,900 28,500 24,100 3.0 1200 4.0 30,500 25,200 33,100 26,400 5.1 0.41" 5.0 33,800 26,800 37,000 28,200 7.8 6.0 36,400 28,000 40,000 29,600 11.1 2.0 26,100 21,900 27,700 22,900 2.6 3.0 31,900 25,600 34,200 26,700 5.6 1200 4.0 36,100 27,700 39,200 29,100 9.5 0.52" 5.0 39,400 29,200 46,300 30,800 14.4 6.0 42,000 30,300 46,300 32,200 20.3 2.0 22,300 19,900 23,700 20,900 1.5 3.0 28,000 23,800 30,200 24,900 3.2 1200 4.0 32,300 26,100 35,100 27,300 5.6 0.31" 5.0 35,800 27,800 39,100 29,200 8.5 6.0 38,600 29,100 42,350 30,700 12.0 2.0 27,400 22,600 29,100 23,600 2.9 3.0 33,400 26,300 35,900 27,500 6.1 1200 4.0 37,800 28,600 41,000 29,950 10.4 0.40" 5.0 41,300 30,100 45,200 21,800 15.9 6.0 43,850 21,200 48,500 33,250 22.3 Form: SEHX/070106-7

Model Number SDXW/CDXW-18-21 SDXW/CDXW-19-21 SDXW/CDXW-24-23 SDXW/CDXW-25-23 SDXW/CDXW-30-27 SDXW/CDXW-31-28 SDXW/CDXW-34-30 SDXW/CDXW-35-30 SDXW/CDXW-36-32 SDXW/CDXW-37-32 HOT WATER HEATING CAPACITY ( 2 ROW HW COIL) Coil Heating PD Heating Capacity @ E.W.T. CFM Rows GPM Ft. Wt. 140 F 160 F 170 F 180 F 2 600 3.0 3.3 21,100 27,300 30,500 33,600 2 600 3.0 3.3 22,500 29,100 32,400 35,800 2 800 3.0 3.3 22,700 29,400 32,700 36,100 2 800 3.0 3.3 22,700 29,400 32,700 36,100 2 1000 3.0 3.7 27,800 36,000 40,100 44,300 2 1000 3.0 3.7 28,000 36,300 40,500 44,600 2 1200 3.0 3.7 29,600 38,300 42,700 47,100 2 1200 3.0 3.7 29,800 38,500 42,900 47,300 2 1200 3.0 4.2 31,800 41,200 45,900 50,600 2 1200 3.0 4.2 32,200 41,600 46,300 51,100 HOT WATER HEATING CAPACITY ( SEPARATE HW COIL 4 PIPE SYSTEM) Model Number Coil Heating PD Heating Capacity @ E.W.T. CFM Rows GPM Ft. Wt. 140 F 160 F 170 F 180 F SCWW/CCWW-18-21 2 600 3.0 3.3 21,100 27,300 30,500 33,600 SCWW/CCWW-19-21 2 600 3.0 3.3 22,500 29,100 32,400 35,800 SCWW/CCWW-24-23 2 800 3.0 3.3 22,700 29,400 32,700 36,100 SCWW/CCWW-25-23 2 800 3.0 3.3 22,700 29,400 32,700 36,100 SCWW/CCWW-30-27 2 1000 3.0 3.7 27,800 36,000 40,100 44,300 SCWW/CCWW-31-28 2 1000 3.0 3.7 28,000 36,300 40,500 44,600 SCWW/CCWW-34-30 2 1200 3.0 3.7 29,600 38,300 42,700 47,100 SCWW/CCWW-35-30 2 1200 3.0 3.7 29,800 38,500 42,900 47,300 SCWW/CCWW-36-32 2 1200 3.0 4.2 31,800 41,200 45,900 50,600 SCWW/CCWW-37-32 2 1200 3.0 4.2 32,200 41,600 46,300 51,100 HOT WATER HEATING CAPACITY ( SINGLE COIL 2 PIPE SYSTEM) Model Number Coil Heating PD Heating Capacity @ E.W.T. CFM Rows GPM Ft. Wt. 140 F 160 F 170 F 180 F SCWW/CCWW-18-21 4 600 3.0 3.3 38,103 46,000 50,900 55,870 SCWW/CCWW-19-22 5 600 3.0 3.3 41,108 49,690 54,980 60,275 SCWW/CCWW-24-23 4 800 3.0 3.3 45,193 54,510 60,380 66,265 SCWW/CCWW-25-23 5 800 3.0 3.3 49,288 59,550 65,910 72,270 SCWW/CCWW-30-27 4 1000 3.0 3.7 53,517 64,600 71,530 78,470 SCWW/CCWW-31-28 5 1000 3.0 3.7 58,048 70,170 77,640 85,115 SCWW/CCWW-34-30 4 1200 3.0 3.7 59,617 72,020 79,745 87,415 SCWW/CCWW-35-30 5 1200 3.0 3.7 64,592 78,100 86,410 94,710 SCWW/CCWW-36-32 4 1200 3.0 4.2 61,448 74,220 82,150 90,100 SCWW/CCWW-37-32 5 1200 3.0 4.2 66,031 79,890 88,350 96,820 Form: SEHX/070106-8

HORIZONTAL CEILING MOUNTEDAIR HANDLER PHYSICAL DIMENSIONS (UNCASED) SEHX/SCWE/SDXW/SCWW A B C 18, 19, 24, 37.00 34.25 30.00 30, 31 45.00 45.25 38.00 34, 35 49.00 46.25 42.00 36, 37 56.00 53.25 49.00 Form: SEHX/070106-9

Ceiling Access Panels: Part Frame Fan Coil Ship Number Dimensions Type Model Number Wt. CPL1 27-1/2 X 43 Louvered 18,19,24 18 CPNL1 27-1/2 X 43 Non-Louvered 18,19,24 18 CPL2 27-1/2 X 49 Louvered 30,31 20 CPNL2 27-1/2 X 49 Non-Louvered 30,31 20 CPL3 27-1/2 X 55-1/2 Louvered 34,35 21 CPNL3 27-1/2 X 55-1/2 Non-Louvered 34,35 21 CPL4 27-1/2 X 62-1/2 Louvered 36,37 22 CPNL4 27-1/2 X 62-1/2 Non-Louvered 36,37 22 Form: SEHX/070106-10

SDXW/CDXW SCWW/CCWW 18 19 24 25 30 31 34 35 36 37 HOT WATER HEATING CAPACITY ( 2 ROW HW COIL) Coil Heating PD Heating Capacity @ E.W.T. CFM Rows GPM Ft. Wt. 140 F 160 F 170 F 180 F 2 600 3.0 3.3 21,100 27,300 30,500 33,600 2 600 3.0 3.3 22,500 29,100 32,400 35,800 2 800 3.0 3.3 22,700 29,400 32,700 36,100 2 800 3.0 3.3 22,700 29,400 32,700 36,100 2 1000 3.0 3.7 27,800 36,000 40,100 44,300 2 1000 3.0 3.7 28,000 36,300 40,500 44,600 2 1200 3.0 3.7 29,600 38,300 42,700 47,100 2 1200 3.0 3.7 29,800 38,500 42,900 47,300 2 1200 3.0 4.2 31,800 41,200 45,900 50,600 2 1200 3.0 4.2 32,200 41,600 46,300 51,100 Operation of SunTherm Air Handler W/ Hot Water Heat Circulating pump and Air Handler blower are energized by conventional heating thermostat. Pump circulared hot water from hot water heater to heating coil in Air Handler and blower circulated warm air throught the duct system. When thermostat is satisified, pump and blower are de-energized. Equipment Sizing 1. Calculate heat loss of structure by ACCA or ASHRAE load calculation method. Air Handler heating capacity should be equal to, or exceed load calculation. 2. Select a water heater whose BTUH input/recovery effeciency exceeds heating capacity of Air Handler. Note: The heating capacity of the Air Handler will not exceed the net output of the water heater. 3. Air Handlers are capable of using hot water from other sources such as boilers as long as hot water does not exceed 180 F. 4. Call a SunTherm Distributor for assistance in sizing. Form: SEHX/070106-11

ACCESSORIES AND OPTIONS FIELD INSTALLED ACCESSORIES AND FACTORY INSTALLED OPTIONS Thermal Expansion Valves (Factory or Field) All Units Downflow Conversion Kits (Multi-Position) TXV3-A Expansion valve 1.5-3.0 tons R-22 DFK41-10 Fits CA0XX820 coils TXV3-B Expansion valve 3.0-5.0 tons R-22 DFK41-12 Fits CA0XXA821,861 coils TXV4-A Expansion valve 1.5-3.0 tons R-410a DFK41-14 Fits CA0XXA822,862,892 coils TXV4-B Expansion valve 3.0-5.0 tons R-410a Specify Field or Factory Installed DFK15-16 DFK15-18 DFK15-20 Fits CA0XXA863 coils Fits CA0XXA864,894 coils Fits CA0XXA865,895,695 coils Hydronic Accessories All Units Accessories for Dedicated Vertical/Wall Mount 68AC002 Pump timer for hydronic coil pruge. WPD02 Wall panel door for 02 models RPA-01 Remote pump assembly 4 GPM 1/2" WPD03 Wall panel door for 03 models RPA-02 Remote pump assembly 4 GPM 3/4" LCD02 Louvered coil door for 02 models RPA-03 Remote pump assembly 7 GPM 3/4" LCD03 Louvered coil door for 03 models Deduct available to remove pump for boiler loop applications. BRP02 BRP03 WB Bottom return air panel for 02 model Bottom return air panel for 03 models Wall Mounting Brackets Field Installed Electric Heaters "S41" Multi-Position S41HK-03 3 KW without breaker B41HK-03 3 KW with breaker S41HK-05 5 KW without breaker B41HK-05 5 KW with breaker S41HK-06 6 KW without breaker B41HK-06 6 KW with breaker S41HK-08 8 KW without breaker B41HK-08 8 KW with breaker S41HK-10 10 KW without breaker B41HK-10 10 KW with breaker B41HK-12 12 KW with breaker Field Installed Electric Heaters "S15" Multi-Position 5 KW without breaker 5 KW with breaker S15HK-05 B15HK-05 S15HK-06 B15HK-06 S15HK-08 B15HK-08 S15HK-10 B15HK-10 B15HK-12 B15HK-15 B15HK-20 6 KW without breaker 6 KW with breaker 8 KW without breaker 8 KW with breaker 10 KW without breaker 10 KW with breaker 12 KW with breaker 15 KW with breaker 20 KW with breaker CPL1 CPNL1 CPL2 CPNL2 CPL3 CPNL3 CPL4 CPNL4 TDR Accessories For Furr Down Horizontal Louvered Access Panel (18,19,24) Non-louvered Access Panel (18,19,24) Louvered Access Panel (25,30,31) Non-louvered Access Panel (25,30,31) Louvered Access Panel (34,35) Non-louvered Access Panel (34,35) Louvered Access Panel (36,37) Non-louvered Access Panel (36,37) Time Delay Relay 3 Typical Thermostat Wiring C 1 AIR HANDLER W W2 G R Y 2 W G R TYPICAL THERMOSTAT LOW VOLTAGE WIRING C Form: -SEHX/070106-12