SMART FIRE CURTAINS INTISI7. for invisible fire protection closures

Similar documents
ACTIVE FIRE CURTAINS INTISI7

ROLL-DOWN FIRE DOORS AND SMOKE CURTAINS

AUTOMATIC FIRE CURTAIN FIRE CURTAIN FM 1

FIREMASTER ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES LEADING THE WAY IN FIRE PROTECTION

Microcontroller based design for Tele-sensing and extinguishing fire

Schueco Fire and Smoke Protection Systems

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

THE WASH WORLD S NEW EXPERIENCE.

FIREMASTER ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES LEADING THE WAY IN FIRE PROTECTION

Smoke and Fire Curtains. Performance Door sets for security and Fire resistant applications. Northern Doors (UK) Ltd

THE WASH WORLD S NEW EXPERIENCE.

FIREMASTER ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES LEADING THE WAY IN FIRE PROTECTION

CI/SfB (68.5) February Intelligent security and fire protection. SecureFire S e c

Fire PROtec. Manual for automatic Fire Curtains. copyright by SIMON RWA Systeme GmbH Passau

ISTOBAL M NEX. Simply brilliant

The Application of Double-deck Inorganic Composite Fire Resisting Shutters in Constructional Engineering Bai-Xia ZHOU*

Underfloor Catalogue Heating products that define the market

FIREMASTER PLUS 2 TENABLE ZONE / HEAT PROTECTION ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES LEADING THE WAY IN FIRE PROTECTION

FIBERSHIELD V FIREIRE CURTAINSURTAINS (COMPACT FLEXIBLE AUTOMATIC FIRE BARRIERS)

fire protection glass

SAC 100 Automatic Smoke Curtain System. - Specifier Information -

+ = FIRE LABORATORY INTRODUCTION. APPLUS+ LGAI - Our company history. High Technology Knowledge. Customer Confidence. Branding

CATALOGUE FURNITURE & INTERIORS

fire protection glass

Workplace FIRE SAFETY

Printing works and warehouse area Press Lane, 21 Ink Street, Presstown. PR3 3SS Postcode: Assessor signature:

Western Firex. Heat & Smoke Ventilator. EAGLE series Natural Ventilation

Corporate Presentation

TX7100. Intelligent Addressable Optical Smoke Detector Installation and Operation Manual. TANDA UK Technology Copyright 2015, All right reserved.

External venetian blinds sunlight included 40% ENERGY SAVINGS WITH INTELLIGENT SUN SHADING

Flygt Top-Entry Agitators CONVENIENT AND EFFICIENT

HART XL High Sensitivity Smoke Detection

Active Infrared Multi Beam Sensors

AUTOMATIC FIREFIGHTING SYSTEMS IN HOSPITALS

Viega Prestabo. Press systems made of galvanised steel in 12 to 108 mm dimensions.

PRODUCT SPECIFICATION FireMaster Plus Concertina

IQ8Control C Fire Alarm Panel

NOXSYS A SYSTEM FOR THE HIGHEST LEVEL OF SECURITY

SMOKESTOP evacu8 ACTIVE SMOKE BARRIERS WITH EGRESS LEADING THE WAY IN FIRE PROTECTION

COLD STORE AIR CURTAIN MAT

HART XL High Sensitivity Smoke Detection

Flexibility right from the start. PAVIRO Public Address and Voice Evacuation System with Professional Sound Quality. boschsecurity.

High-Speed Roll Doors An intelligent entrance solution for every location. ASSA ABLOY Entrance Systems

CONTENTS PRODUCTS AND INNOVATIONS OF THE HELLA GROUP. SINTESI 12 The innovative pergola. Pergolas 06 Overview. Design characteristics 18 HELLA 22

Moffitt Firex. Heat & Smoke Ventilator. MoffittCorp.com (800) th Ave S. Suite 130 Jacksonville Beach, FL

CR SERIES. Special doors for clean room applications

TPW-900ETS01. Product Manual. Intelligent Swing Gate Turnstile

External venetian blinds

Firetex steel fire shutters

USER MANUAL COMBINED FIRE & EXTINGUISHING CONTROL PANEL COMPLIES WITH BS EN PART 1 & EN54 PARTS 2 & 4

Outdoor Enclosures. Outdoor Enclosures Protected like a bunker for all harsh environments

GENERAL STAND BUILDING REGULATIONS AND INFORMATION

Active Infrared Multi Beam Sensors. R Series

HRS Hand Rail System 1

Güntner Info GVX. with microox technology kw. Always a step ahead: microox condenser system with maximum installation flexibility

Instructions for Robust Fiber Appendix 4 Robust sites and nodes. Ver 1.2

FIRE SAFETY PRACTICES AND PROCEDURES

Fire Risk Assessment. Guidance Notes. Location details. Risk Rating. Assessors. General notes

ROLLER SHUTTER SOLUTIONS AS UNIQUE AS YOUR VISION. RollUp Serranda (Pty) Limited 0860 ROLLUP ( )

Elite. GJD022 /GJD023 35m External PIR. Multi Beam Lens Data

Room sealed circuit appliance sold without the terminal or the combustion air supply and exhausted gas ducts. TYPE C 63 TYPE B TYPE B 23

PASSIVE FIRE PROTECTION FTI-MARNEROS LTD

INTEGRATED PIPING SYSTEMS. The complete piping system with M-profile press fittings. VSH XPress

SCREEN VISION SV 3% KOOLBLACK TM

PRODUCT SPECIFICATION FireMaster NVS Horizontal Simplex

The Owner will provide the QEI inspection and certification services.

SmartStruxure Lite Small Building Systems

FIRE DOOR CLOSING SYSTEMS

NYU RESIDENTIAL FIRE SAFETY PLAN PART I - BUILDING INFORMATION SECTION

LASER SAFETY BARRIER

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

Optimal work climate with open doors. Industrial air curtains Model IndAC

SIMPLY THE WIDEST FOLDING DOOR. FFT FLEX Green. Maximum clear opening widths and best thermal separation.

RG1,5SA Self Adhesive

Different types of Fire Alarm System

The Social Accountability International (SAI) Fire Safety Checklist

Performance Based Fire Protection With Water Mist

SECTION ELEVATOR FIRE RATED SMOKE CONTAINMENT SYSTEM

L900 series USER MANUAL

30RB Air-Cooled Liquid Chillers PRODUCT SELECTION DATA. Easy and fast installation. Compact, reliable and efficient

Zerio Plus EDA-R6000 Radio Combined Optical Smoke Detector and Sounder Installation Instructions

Fire damper DESIGN GENERAL FIRE CELL DIVISION DISTRIBUTION OF RESPONSIBILITIES FIRE PROTECTION DOCUMENTATION HAGAB FIRE DAMPER DESIGN

SKG-IKOB Certificatie B.V. Trading under the names SKG, IKOB-BKB and SKW Certificatie

LINDOFLAMM thermal engineering.

Total Connect Box. User manual

Movement by Perfection. The Royal League in ventilation, control and drive technology. Fans for agriculture. Durable, efficient, well designed

MultiSensor 6. Make your home really intelligent. 6 sensors. 6 times the smarts. Motion sensor. One tiny device packed full of intelligence.

Model 17A00 Expansion Enclosure

EN54-23 Beacons & Sounder Beacons

TX7110. Intelligent Heat Detector Installation and Operation Manual. TANDA UK Technology Copyright 2015, All right reserved.

Unit 2 Fire Safety (Zone 2)

Energy Saving Results for Cheetah. Cheetah Energy Saving in Commercial Kitchens

Instruction Manual WARNINGS

A. Codes and Standards that are Standard at the University:

This annex is valid from: to Replaces annex dated: Locations where activities are performed under accreditation

Passive fire protection. 6 Passive fire protection. 6.1 Fire compartmentation. Passive fire protection

Fire-Cryer. Plus Application Guide APPLICATION GUIDE FIRE EXIT VIMPEX. Shaping Alarm Technology

2-way. One source of elements. Many opportunities for greater profits. communication

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

Who we are? - Nº 1 Spanish fire alarm systems manufacturer years experience in the fire detection field countries worldwide.

Transcription:

SMART FIRE CURTAINS INTISI7 for invisible fire protection closures

2 INTISI INTISI ı Fire Engineered FABRICS was founded with the aim of being a technological partner for the development and production of textile solutions for fire protection, smoke control and insulation. From Barcelona, a team of technical experts and engineers design and manufacture textile technology products under premises of INTELLIGENCE, INTEGRITY and INNOVATION. What does engineering require? How can anyone perfect anything?? From which approach we start?? FOCUS? PROVIDE ANSWERS THEN WE BEGIN TO CRAFT AROUND OUR IDEAS SIMPLIFYING REINVENTING INNOVATING IMPROVING UNTIL EVERYTHING WE CREATE ENHANCES ITS VALUE PERSONALISED PERIPHERAL SERVICES Technical advice and consultancy Repair of curtains at own Technical Service facilities Development of personalised solutions

INVISIBLE FIRE PROTECTION CLOSURES BY MEANS OF TEXTILE FIRE CURTAINS 3 INTISI REQUIREMENT Construction regulations require dividing zones to prevent fire from spreading from one area to another in a building, containing the fire at the site of its source. The standard UNE EN 1634-1 regulates fire resistance tests and classifies textile fire curtains as an asymmetric enclosure, since they consist of roll-up closures. OBJECTIVE Create fire protection closures under different protection requirements according to UNE EN 13501-2 standard. In order to ensure the integrity against fire on both sides, asymmetrical fire curtains must be tested against fire on the side where its components are located (supporting items, guide rails and motor). E + Integrity + Guarantee for containing flames and hot gases on the side exposed to fire. EI + Integrity + Insulation + Guarantee for containing flames and hot gases on the side exposed to fire. + Guarantee that heat transfer does not cause a fire on the side not exposed to the flames.* EW + Integrity + Reduced heat radiation + Guarantee for containing flames and hot gases on the side exposed to fire. + Limiting of heat radiation transfer, preventing ignition of materials and people damages on the side not exposed to the fire. * Thermal insulation by means of sprinklers with low pressure closed nozzles and quick response thermal-fuses.

4 INTISI INTISI FIRE CURTAIN DESIGN 5 3 4 2 1 6 7 8

5 INTISI 1 CHASSIS Metal chassis with dimensional stability to house the fabric and different system components. Its blunt edge design limits its friction with the fabric to ensuring full integrity and durability of the different components. 2 3 4 LTP24 MOTOR BLOCK 24V high performance tubular motor block, tested to 2350 continuous cycles, now more silent and reliable. The advanced Gravity Fail Safe technology ensures closing of the system by gravity which does not require any cooling stops during operation. TUBULAR SHAFT WITH EASY-FAST SYSTEM Ball bearing rotation mechanism to guarantee aligned spin of the fabric without rubbing, thus eliminating any risk of wear by friction, noise, and overloads on the LTP 24 motor. ANCHORING SYSTEM WITH SKATIP DESIGN A 21 mm thickness, twin-body securing mechanism designed to guarantee system effectiveness and efficiency. 5 TELESCOPIC ROLLER BRIDGE A bridge mechanism with telescopic ROLBRID system to support and align large size Intisi fire curtains (WIDE series). 6 Intisi tex TECHNICAL FABRIC Latest generation technical fabric made from fibreglass reinforced with stainless wire to guarantee integrity at high temperatures. 7 8 GL SIDE GUIDES The fabric guiding system consisting of rigid angular strengtheners, guiding bearings, stainless tubular axle and low-friction guiding ring to guarantee tightness and integrity of the Intisi fire curtain against gases and flames in the event of a fire. SEALING STRIP A compact angular rigid counterweight mechanism with joining nozzles and carriers to guarantee the secure operation of the Intisi fire curtain without electrical power by means of Gravity Fail Safe technology at a low and controlled speed. The device is attached to the Intisi tex fabric by means of a looping system over one securing axle.

6 INTISI intisi 7 INVISIBLE VERTICAL FIRE CURTAINS A change of perspective. Guaranteed safety, control and integrity Intisi 7 is the future in textile fire curtains intended for an invisible fire protection closure, for it is the first smart fire closure system. Its advanced components mean a fire resistance classification E120, EI120 and EW120 up to 1100ºC with maximum dimensions up to 22 metres wide. Intisi 7 fire curtains guarantee compliance with current European legislation.

RELIABILITY SPEED 7 INTISI SIMPLICITY IS NOT SOMETHING SIMPLE GRAVITY FAIL SAFE TECHNOLOGY Gravity closure at a controlled speed. INTELLIGENCE All components are conferred with technology to enable fire curtains to solve problems. ULTRA SIZE 22 m non overlapped maximum dimensions certified as per EXAP pren 15269-11. REVERSIBLE They are the only fire curtains certified to protect 2 fire sectors. The advanced technology applied to each Intisi 7 fire curtain component ensures optimisation of assembly and maintenance time, not disregarding the integrity of the system against fire. ULTRA COMPACT The small size of the system means it can be fully integrated in the space. EASY TO ASSEMBLE The design of each part is ideal for simple assembly and maintenance. CERTIFIED QUALITY Intisi 7 fire curtains have been tested to the most demanding European standards. GUARANTEED SAFETY All the advantages of Intisi 7 fire curtains are meant to provide complete safety against fire. MINIMUM SPRINKLERS Intisi 7 fire curtains are EI120 fire rated, with sprinklers distributed every 2 metres only.* CLOSED SPRINKLERS Invisible EI120 fire closure through the certified Intisi-SC sprinkler system. *Advantages for the Intisi fire curtain range with EI120 fire rating. SAFETY

8 INTISI intisi 7 GUARANTEED EI INTEGRITY AND INSULATION SUITABLE FOR PROTECTING TWO FIRE SECTORS In order to guarantee complete effectiveness and reliability of vertical Intisi 7 fire curtains; as an ASSYMETRIC closure item, the curtains have been tested under the least favourable conditions, i.e.: with all components exposed to direct attack from fire. This enables its installation to divide two fire sectors, in accordance with EN UNE 1634-1. Fire curtain tested with the chassis and side guides outside the fire zone. Valid for protecting areas with fire in 1 single fire sector. Intisi 7 vertical fire curtains Fire curtain tested with the chassis and side guides inside the fire zone, for they are designed to withstand direct fire. Valid for protecting areas with a fire affecting 2 fire sectors.

9 INTISI intisi-sc SPRINKLER SYSTEM Intisi 7 vertical fire curtains are rated EI 120, based on the Intisi-SC closed nozzle sprinkler system. The only certified closed nozzle system K80 sprinkler with quick response bulb type thermal fuses. Sprinklers fitted every two linear metres of the system 1.1 bar working pressure. Fitting of sprinklers on the side opposite to the chassis First hidden sprinkler system above the false ceiling

10 INTISI intisi 7 VERTICAL FIRE CURTAIN SERIES intisi 7 LIGHT The Intisi 7 light vertical fire curtain, developed for fire protection closures of small areas with fire curtains. System width (A) System height (H) Fabric Frame size (P x C) 5metres 3 metres Tex-FPI 1.7 metres Tex-EW120 3 m < H 10 metres Tex-FPI 1.7 m < H 5.5 metres Tex-EW120 COMPACT 190 x 200 mm COMPACT+ 235 x 290 mm intisi 7 WIDE The Intisi 7 wide vertical fire curtain, developed when it is necessary an invisible fire protection closure in a large space. System width (A) System height (H) Fabric Frame size (P x C) 5 > to 22 metres 8 metres Tex-FPI 4 metres Tex-EW120 8 < H 10 metres Tex-FPI 4 < H 5.5 metres Tex-EW120 COMPACT+ 235 x 290 mm COMPACT pro 260 x 315 mm Telescopic roller bridges Supporting mechanism for the Intisi 7 wide system.

intisi TEX FABRIC RANGE 11 INTISI Technical fabric to ensure integrity against fire based on fibreglass reinforced with stainless steel wire, to provide the system with tensile strength, and a primer coating which, depending on the required application, prevents the loss of properties of the textile technology. It is identified with a quality mark based on black coloured longitudinal threads. It reaches an E120 fire rating, and in conjunction with the Intisi-SC sprinkler system, guarantees an EI120 fire rating. High temperature resistant textile technology, to guarantee the integrity while limiting the heat radiation of fire by providing EW120 rating thanks to the aluminized finish on both sides. intisi 7 GL SIDE GUIDES Type Guide size (G x F) Max. height (H) Max. width (A) GL120 120 x 74 mm 6 metres 13 metres GL175 175 x 74 mm 10 metres 13 < to 22 metres intisi 7 APPLICATIONS Intisi 7 indoor vertical fire curtains Intisi 7e fire curtains for outdoor façades Indoor vertical fire protection closures Closure of inner windows Indoor fire closures of doors and lifts Protection for halls Kitchens or areas containing devices intended for preparing food that could cause ignition Fire protection closure of building façades Vertical closure of façades on adjoining buildings Closing of windows on façades Fire closure of rooflight domes or skylights with façades Façade protection in inner courtyards Fire closure for automatic extinguishing systems

12 INTISI SMART CONTROL CORE SI03c CONTROLLED SAFETY FEATURES Operability. Makes the closure function of Intisi 7 fire curtains effective, in a controlled manner. Personalised programming. The advanced processor permits a large number of programming parameters to be stored. Intelligence. Enables Intisi 7 fire curtains to resolve problems autonomously through its permanent status of self-diagnosis and selfanalysis. Memory. Up to 255 events can be stored. Communication. Users are provided information about the system status in real time, via WIFI, TCP-IP, GSM, etc. Safety. Permits evacuation of people found in the area of the fire and action by the firefighter. Multi-purpose. Fitted with an area to connect fire detection devices. The Intisi SI03c smart control core governs the Intisi 7 fire curtains efficiently and effectively. FLASH INTISI 7 Siren Alarm MAX. 32 DETECTORS EMERGENCY EXIT WIFI TCP-IP GSM FIRE CENTRE

13 INTISI SPECIFICATIONS Advanced i3 processor, designed with 32 bit architecture. Remote connectivity to advanced applications (WIFI, TCP-IP, GSM, etc). Pulse width modulation technique PWM. Hall effect encoder, providing over 6000 information bits per minute. 24V back-up UPS device with automatic monitoring and charging of its battery pack. 230V AC / 50 Hz power supply. Dimensions: 315 x 320 x 85 mm. PROGRAMMING The advanced technology featured in the SI03c Smart Core Control permits personalised programming to adapt to the requirements of each client. Basic programming is permitted directly from the Core Control. Advanced programming may be carried out through the Intisoft application. A special programming option is available for emergency exit to evacuate trapped persons. Intisoft Permits remote monitoring of events log and status (in real time) for the Intisi 7 fire curtains.

14 INTISI WE ADAPT OUR SOLUTIONS TO YOUR NEEDS LOGISTICS SECTOR Logistics centres are buildings that are carefully designed to optimise the logistics activity with maximum use of space. INDUSTRIAL SECTOR Industrial activities require high levels of safety and protection with maximum optimisation of space. PETRO-CHEMICAL SECTOR Petro-chemical plants require a culture of preventive safety for the risks involved in their own activity. NUCLEAR POWER PLANTS Nuclear power plants involve high specific risks which need to be controlled and foreseen. FOOD AND AGRICULTURE SECTOR The food and agriculture industry must ensure the healthiness, hygiene and freshness of the products, and provide a safe environment for employees and animals. MALLS AND BUILDINGS Non-industrial establishments are pioneers in new construction trends, constantly facing new architectural challenges. CULTURAL ESTABLISHMENTS Theatres and concert halls are public establishments, that could involve the use of equipment and activities that can be hazardous to people and pose a threat to the integrity of the building.

CERTIFIED SAFETY AND INTEGRITY INTISI APPROVALS 15 INTISI Intisi systems prove their high quality, reliability and accuracy in many tests, certifications and approvals by accredited official laboratories, in accordance with European standards. intisi 7 TEXTILE FIRE CURTAINS Fire resistance test according to UNE EN 1634-1. Certified fire classification according to UNE EN 13501-2. Measurement extension test according to EXAP or EN 15269-11. Self-closing durability test to 2350 cycles according to UNE EN 14600 and UNE EN 12605. Technical evaluation of suitability for use. All this is in accordance with current European standards. INDEX 2 THE COMPANY 3 FIRE PROTECTION CLOSURES 4 FIRE CURTAIN design INTISI 7 6 INTRODUCTION 7 FEATURES 8 FIRE RESISTANCE 9 INTISI-SC SPRINKLERS 10 TECHNICAL DETAILS 12 S103C SMART CONTROL CORE 14 SOLUTIONS 15 CERTIFICATES

Fire Engineered Fabrics Carrer Indústria, 28D P.I. La Bóbila 08320 El Masnou (Barcelona Spain) T. (+34) 935 401 913 E. intisi@intisigroup.com W. www.intisigroup.com INTISI7-EN03-05/2016