SMOKE & FIRE THE LEADING EDGE IN. Smoke & Fire Curtains

Similar documents
AUTOMATIC FIRE CURTAIN FIRE CURTAIN FM 1

FIREMASTER ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES LEADING THE WAY IN FIRE PROTECTION

FIREMASTER ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES LEADING THE WAY IN FIRE PROTECTION

FIREMASTER ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES LEADING THE WAY IN FIRE PROTECTION

FIREMASTER CONCERTINA TM

Technical Manual (European Standards)

THE LEADING EDGE IN Smoke & Fire Curtains

CI/SfB (68.5) February Intelligent security and fire protection. SecureFire S e c

SMOKESTOP evacu8 ACTIVE SMOKE BARRIERS WITH EGRESS LEADING THE WAY IN FIRE PROTECTION

ACTIVE FIRE CURTAIN BARRIER FOR DOMESTIC & COMMERCIAL APPLICATIONS

FIREMASTER PLUS 2 TENABLE ZONE / HEAT PROTECTION ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES LEADING THE WAY IN FIRE PROTECTION

FIRE & SMOKE CURTAINS

FireMaster. The Fire Curtain Barrier WITHOUT CORNER POSTS. Inspiring design, maximising floor space and increasing income.

SAC 100 Automatic Smoke Curtain System. - Specifier Information -

PRODUCT CATALOGUE ACTIVE FIRE AND SMOKE CURTAIN BARRIER ASSEMBLIES LEADING THE WAY IN FIRE PROTECTION

Smoke and Fire Curtains

Won-Door FireGuard T H E P E R F E C T F I T I N A V A R I E T Y O F A P P L I C A T I O N S

FIRE & SMOKE CURTAINS

A REVOLUTIONARY APPROACH TO FIRE SAFETY

incorporating Guidance to Shafts for Smoke Control A useful guide to practical smoke shaft principals and specifications

Smoke and Fire Curtains. Performance Door sets for security and Fire resistant applications. Northern Doors (UK) Ltd

ACTIVE FIRE CURTAINS INTISI7

SECTION ELEVATOR FIRE RATED SMOKE CONTAINMENT SYSTEM

Mechanical Smoke Extract Shaft Systems

Fire Suppression Systems

PASSIVE FIRE PROTECTION FTI-MARNEROS LTD

Notifier by Honeywell: Non-Addressable Audible & Visual Alarm Devices. Approved to EN54-3/EN54-23

PRODUCT SPECIFICATION FireMaster Plus

BLE Smoke and Fire Curtains

Mechanical smoke ventilation systems. CI/SfB 37.4 Xy

PRODUCT SPECIFICATION FireMaster NVS Horizontal Simplex

FIRE SAFE NOTICE BOARDS Education Buildings SPECIFYING FIRE RATED NOTICE BOARDS. Issue #1

In accordance with: Period of Fire Resistance: 180 minutes (3 hours) integrity (single) 120 minutes (2 hours) integrity (overlapped)

PRODUCT SPECIFICATION FireMaster Plus Concertina

Maximum Dimensions: Approved for spans unlimited in width, heights up to 10.5 m ( in), minimum panel overlap 400 mm (15.

REPORT HOLDER: SMOKE GUARD, INC. 287 NORTH MAPLE GROVE ROAD BOISE, IDAHO EVALUATION SUBJECT:

PRODUCT SPECIFICATION FireMaster Concertina

Commercial. Tel:

Insulation AN INTRODUCTION. Low Energy Low Carbon Buildings. Second Issue April See rear cover for applicable countries

technical specification smoke venting systems

MANSION A HAND-PICKED COLLECTION FOR LUXURY LIVING

Product Guide. The highest possible standards. The best possible solutions. Manufactured in the UK. Cert No 5893 ISO 9001

Evacuate everyone Sonos Pulse & Nexus Pulse

Appendix A: US Fire Statistics Tables

FGS 35 SLIMLINE SLIDING DOOR SYSTEM

Loss Prevention Standards

Fire Risk Assessment

Fire Alarm Systems Design. incorporating Amendment No.2. a guide to BS5839. Part1:2002

22 BISHOPSGATE Lift Evacuation Strategy

CONVENTIONAL AUDIBLE VISUAL

General Principles of Smoke Control

Aspirating Smoke Detection for Large Area Coverage Applications

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT NO 68 (ENGLISH AND PHILOSOPHY)

Beautifully Designed Bespoke Doors & Windows 1

/WON BuyLine 3726 WON-DOOR. FireGuard. The ORIGINAL horizontal sliding accordion fire door.

Evolution in Emergency Lighting 7 March 2018

Uniclass L442 CI/SfB (34) X. Architectural Handrail and Balustrade. Architectural metalwork systems

YOUR SINGLE SOURCE FOR EMERGENCY RESPONSE CLOSURE PRODUCTS

All by design. ASSA ABLOY Door Controls

GLASS THAT WILL SHAPE YOUR THINKING

AVAILABLE TO DOWNLOAD ON THE APOLLO APP. Pocket guide to. Fire Alarm Systems Design BS Standard

Fire Safety Policy Date: 0

PARTNER PRESENTATION 2016

Outdoor Enclosures. Outdoor Enclosures Protected like a bunker for all harsh environments

enhance your view Manufactured Your local Liniar stockist: For more information and to find your nearest fabricator visit

Construction Products Regulation (CPR) and BS 6701

Remote Control Garage Doors

Element C3.5 Means of Escape

PASSIVE FIRE PROTECTION GETTING IT RIGHT

INTRODUCTION HOW DO RADIANT PANELS WORK? A common misconception, even among heating professionals, is that heat rises. In fact, hot air rises and cold

REGULATORY REFORM (FIRE SAFETY) ORDER 2005 PERIODIC REVIEW OF FIRE RISK ASSESSMENT

Trimless In-Ceiling & In-Wall

REGULATORY REFORM (FIRE SAFETY) ORDER 2005 PERIODIC REVIEW OF FIRE RISK ASSESSMENT

Fire resistance. Appendix E. E.1 Fire resistance. Appendix. (A copy of this Appendix is available on /)

Maintenance Solutions from SE Controls

This document is a preview generated by EVS

1 P a g e w w w. s m o k e c o n t r o l. c o m. a u

FIBERSHIELD V FIREIRE CURTAINSURTAINS (COMPACT FLEXIBLE AUTOMATIC FIRE BARRIERS)

RADIANT PANELS COMMERCIAL BUILDINGS INNOVATIVE VENTILATION & HEATING

fire resistance testing

Transaction Windows and Security Entrances

KEEP THE FIRE FROM SPREADING

WORLDWIDE VENTILATION SOLUTIONS

Dangerous Assumptions

The new generation. Solus. for straight stairs. Better by design

BS EN ISO : 2010

Fire Risk Assessment

Prescriptive Requirement for Smoke Control

Specified Systems List

Window blinds and Soft furnishings for the Healthcare and Education markets

9/23/ :47 AM. Second Revision No NFPA [ New Section after ] Submitter Information Verification. Committee Statement

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Fire Door Maintenance Guide.


Managing Fire Safety in Occupied Buildings FM Ireland Fire Safety Theatre

THE RIGHT PRODUCT IN THE RIGHT PLACE

Foxpond Northside Birtley County Durham DH3 1RB

Create your dream living space to enhance your lifestyle and compliment your home. The Conservatory Collection

2. Curtains. 2.3 Curtains: Introduction

TILT AND SLIDE WINDOW

Transcription:

THE LEADING EDGE IN > Automatic Smoke Curtains > Automatic Fire Curtains > Static Smoke Curtains > Accordion & Horizontal Curtains > Service & Maintenance L&F SMOKE & FIRE Smoke & Fire Curtains A Lowe & Fletcher Group Company

Welcome to BLE Why Choose BLE? At BLE we are continually striving to improve the safety of your world. In the event of a fire, our gravity fail-safe curtains automatically deploy to contain smoke & fire. This slows down how quickly it can spread across a building, crucially allowing more time for safe emergency evacuation. As a market leading global supplier, our products protect millions of people every day. Our curtains are rigorously tested and manufactured to the highest technical and quality standards, including BS, EN and UL. Smoke & Fire Curtains Simple, efficient and cost effective smoke and fire curtains from BLE are invaluable for protecting the occupants within large open buildings from the threat of fire, smoke and hot gasses. Active smoke barriers provide an unobtrusive and aesthetically neutral solution to compartmentation issues throughout the most complex of buildings. Using the latest CAD and manufacturing technology, we are able to create bespoke smoke barriers for the most complex smoke control system, regardless of what type of building it is protecting or where it is in the world. Active fire barriers are similarly discreet in design and are suitable for use in a range of fire scenarios. Control systems require minimal maintenance and are designed to be robust and simple, whilst also providing advanced features such as emergency retract, obstruction sensors and audio / visual warnings. Tel: 0114 251 4703 Email: enquiries@blecurtains.com

Contents Applications Protected Means of Escape 4 Elevator Doors 4 Elevator Lobbies 4 Escalators & Stairs 4 Fire Door Replacement 5 Fire Compartmentation 5 Smoke Compartmentation 5 Smoke Channelling 5 Fire Curtains FC1 / FC60 (British, European & UL Standards) 6 FC2 / FC240 (British, European & UL Standards) 6 FC4 (British, European & UL Standards) 7 Smoke Curtains SC1 / SD60 (British, European & UL Standards) 8 SC2 Fixed (British & European Standards) 9 Accordion & Horizontal Curtains Accordion AC1 (UL Standard) 10 Horizontal HC1 (British & European Standards) 11 Service & Maintenance Why Do I Need to Service? 12 How Often Do I Need to Service? 13 How Can BLE Help? 13 BLE Service Packages 13 Case Studies Warwick Hotel - Doha 14 US Embassy - London 15 Beekman Hotel - New York 15 Website: www.ble-smokeandfirecurtains.com 03

Applications Protected Means Of Escape Elevator Doors BLE fire curtains can provide a protected means of escape that when not in use allows designers the freedom to achieve modern open plan spaces. While most elevator doors provide a fire integrity rating they do not prevent smoke leakage. BLE offer a UL approved smoke containment curtain that can be discreetly installed around the elevator door, making the curtain invisible when retracted. Elevator Lobbies Escalators & Stairs It may be required to create a protected lobby in front of a bank of elevator doors. Where this would previously have required the construction of a physical smoke and fire rated partition, a three sided lobby can now be produced using curtains. Smoke curtains can be used around the lower level to create a deep reservoir to prevent smoke moving to upper levels. Fire curtains can be used to seal off the stairwell completely if required. Intelligent control systems linked to the escalator operation can be provided to ensure effective means of escape are maintained. Tel: 0114 251 4703 Email: enquiries@blecurtains.com

Fire Door Replacement Fire Compartmentation A BLE fire curtain can be specified as an alternative, offering the same levels of integrity. The curtain can be recessed within the ceiling and walls, or face fixed depending on customer requirements. It will then remain there hidden, but always ready to deploy in the event of a fire. Curtains installed to form a compartment must be able to provide a physical barrier to the fire and prevent heat flux transfer of levels sufficient to ignite materials either side of the compartment. Smoke Compartmentation Smoke Channelling Often in conjunction with an integrated ventilation system, smoke compartments are formed to prevent smoke spreading throughout a building. They must be impermeable to smoke leakage, within set criteria, but also offer a level of resistance to heat. Smoke channels should be designed with due consideration given to the potentially large extraction units. BLE smoke curtains can be easily combined with ventilation systems to provide an integrated solution. Website: www.ble-smokeandfirecurtains.com 05

Fire Curtains FC1 / FC60 FC2 / FC240 Key Info Cost effective & reliable the FC1 is the ideal solution for smaller projects. Material Glass cloth with a micronized aluminium polymer coating on each side of the fabric. Fire Integrity Rated at 1000 o C for up-to 60 minutes Integrity and 60 minutes Radiation to BS EN 1634-1. Key Info The highest performing fire curtain in the BLE product range. Material Stainless steel, wire reinforced, woven glass fibre fabric coated on each side with silver polyurethane. Fire Integrity Rated at 1000 o C for up to 240 minutes Integrity & 60 minutes radiation to BS EN 1634-1 & BS476 Part 22. Tel: 0114 251 4703 Email: enquiries@blecurtains.com

FC4 Key Info A fire curtain that can also provide radiant heat protection Material Built up of two layers of wire reinforced glass fabric with aluminium foil laminated to the outer sides.the fabric is silver & reflective in colour. Fire Integrity Rated upto 1000 o C for 120 minutes with enhanced resistance to the irradiance of heat. British & European Standards Model Width (M) Drop (M) Fire Resistance (mins) Integrity (E) Irradiance (W) FC1 3.0 3.0 60-2.8 2.5 60 30 1.4 2.5 60 60 FC2 7.0 8.0 60 30 7.0 7.0 120 30 7.0 6.0 180 30 7.0 5.0 240 30 2.4 2.7 240 60 Unlimited 6.0 240 - FC4 2.6 2.7 120 120 UL Standards Test Standard BSEN 1634 BSEN 1634 BSEN 1634 Certificate / Reports Certifire CF5432 Certifire CF5433 WF341904 WF342381 7.0 4.0 60 60 WF349970 Model Width (M) Drop (M) Classification Test Standard FC60 45.0 12.0 60 mins fire rating UL 10D UL1784 FC240 45.0 12.0 120 mins fire rating in gypsum 180 mins fire rating in masonry UL 10D UL1784 Certificate / Reports 20151020-R26410 20120808-R26410 20151020-R26410 20120808-R26410 Website: www.ble-smokeandfirecurtains.com 07

Smoke Curtains SC1 / SD60 Key Info Specified by Building Owners, Architects and Engineers in buildings across the world, our SC1 active smoke curtains protect some of the world s most high-profile buildings. Material Glass cloth with a micronized aluminium polymer coating on each side of the fabric. Fire Integrity Rated at 600 C for 120 minutes to BSEN12101-1 British & European Standards Model Width (M) Drop (M) Classification Test Standard SC1 Unlimited 10.0 D120 / DH60 BSEN 12101 UL Standards Model Width (M) Drop (M) Classification Test Standard SD60 45.0 12.0 60 mins fire rating UL 10D UL1784 SD240 45.0 12.0 120 mins fire rating in gypsum 180 mins fire rating in masonry UL 10D UL1784 Certificate / Reports Certifire CF5030 EC CoC 1121 CPR FA001 Certificate / Reports 20151020-R26410 20120808-R26410 ICC-ESR-3322 20151020-R26410 20120808-R26410 Tel: 0114 251 4703 Email: enquiries@blecurtains.com

SC2 Fixed Key Info The SC2 fixed smoke curtain can be manufactured to suit any shape or size and is used extensively in aircraft hangars and warehouses where the barrier is able to stay permanently in position. Material Glass cloth with a micronized aluminium polymer coating on each side of the fabric. Fire Integrity Rated at 600 C for 120 minutes to BSEN12101-1 British & European Standards Model Width (M) Drop (M) Classification Test Standard Certificate / Reports SC2 Unlimited 10.0 D120 BSEN 12101 Certifire CF5030 EC CoC 1121 CPR FA001 Website: www.ble-smokeandfirecurtains.com 09

Accordion & Horizontal Accordion AC1 Key Info Developed for applications where there are no structural columns or posts to fit side guides at corners. An ideal solution for buildings with large open spaces. Material Stainless steel, wire reinforced, woven glass fibre fabric coated on each side with silver polyurethane. Fire Integrity Upto 180 minutes integrity to the UL10D Standard Accordion (UL Standards) Model Accordion AC1 (SD240A) Width (M) Drop (M) Classification 45.0 5.0 120 mins fire rating in gypsum 180 mins fire rating in masonry Test Standard Certificate / Reports UL 10D 20120808-R26410 Tel: 0114 251 4703 Email: enquiries@blecurtains.com

Horizontal HC1 Key Info For use in multi-story buildings to prevent fire & smoke progressing through stairwells and atrium voids to upper floors. Material Stainless steel, wire reinforced, woven glass fibre fabric coated on each side with silver polyurethane. Fire Integrity Rated at 1000 C for a period of up to 180 minutes integrity to BS EN 1634-1. Horizontal (British & European Standards) Model Horizontal HC1 Width (M) Drop (M) Fire Resistance (mins) Integrity (E) Irradiance (W) Test Standard Certificate / Reports 6.0 6.0 180 - BSEN 1634 WF333819 WF333952 WF337802 Website: www.ble-smokeandfirecurtains.com 11

Service & Maintenance Why Do I Need to Service? Smoke and fire curtains are life safety systems. Designed to prevent the spread of smoke and fire through a building, they help protect human life in the event of an emergency. In accordance with the Regulatory Reform (Fire Safety) Order 2015 (Section 17, Part I) it is a legal requirement that ALL life safety systems are regularly serviced and maintained. Tel: 0114 251 4703 Email: enquiries@blecurtains.com

How Often Do I Need to Service? The frequency of service and maintenance required is determined by various factors, including the use and occupancy of the building. BLE offer a number of comprehensive service packages to maintain installed smoke and fire curtains including emergency call outs for malfunctioned barriers, whatever the cause. How Can BLE Help? BLE can provide servicing for all existing types of BLE smoke & fire curtains - whether we installed them or if they were installed by a BLE distributor. Unfortunately we are not able to offer service packages for non BLE systems. However we are able to quote for a BLE replacement curtain, which would then be eligible for one of our service packages. BLE Service Packages We offer a variety of service options to suit your needs, including 1, 2 & 3 year packages. Each package allows for 1 annual visit. For more information about Service & Maintenance, or to discuss your requirements call 0114 251 4703 or email enquiries@blecurtains.com Website: www.ble-smokeandfirecurtains.com 13

Case Studies At BLE, not only do we provide smoke & fire containment solutions across the UK, but also across Europe, the Middle East, Far East, Asia, India and the USA.The following case studies highlight just a few of the high profile projects we have worked on in recent years - visit the BLE website for more. Warwick Hotel, Doha Blending classic and contemporary styling the Warwick Hotel provides a new standard of luxury amid Doha s busy city centre. The hotel offers elegant suites, refined dining options and rejuvenating spa facilities, as well as a breathtaking rooftop swimming pool. Working in partnership with Energy International, BLE were delighted to supply the hotel with a number of fire curtains - primarily for the generator and transformer rooms. In the event of a fire, the curtains will automatically descend to contain smoke & fire for a set period of time, allowing for safe evacuation. Speaking of the project, Energy International s Ziad Khaled has said Working with BLE is always such a pleasure. They listened to our requirements and delivered a cost effective solution on time. Tel: 0114 251 4703 Email: enquiries@blecurtains.com

US Embassy, London Located in Nine Elms, South West London, the new US Embassy is quickly becoming one of the most talked about developments in recent memory. Developed specifically to provide a much higher level of security than ever before, including bollards, ditches and a reflective pool that doubles as a moat. Working with main contractor Sir Robert McAlpine, BLE were tasked to supply and install a number of FC1 Fire Curtains for the elevators on each floor of the Embassy. The project presented several new challenges for BLE s team of installation experts, from the high levels of security onsite, to having to work around the building s unique architectural design. New US Embassy Image Copyright Kieran Timberlake Beekman Hotel, New York An iconic part of the New York skyline since 1761, the Beekman Hotel combines traditional architecture with luxury accommodation. Working with US Smoke & Fire, BLE were asked to supply a number of SD60 Smoke Curtains (UL Specification) for use in the hotel. Speaking of the project, US Smoke & Fire s CEO Steven Sadeghian PhD This was a challenging project for all involved but BLE were able to manufacture ultra compact housings with varying headbox sizes on single runs to not obstruct historic metal medallions that could not be touched on each floor, whilst also maintaining a full fabric seal throughout the length of the corridor. Website: www.ble-smokeandfirecurtains.com 15

BLE SMOKE & FIRE CURTAINS IS RECOGNISED AS THE LEADING EXPERT IN THE DESIGN, MANUFACTURE, COMMISSIONING, INSTALLATION AND MAINTENANCE OF FIRE DETECTION AND PROTECTION SYSTEMS. CONTACT BLE BLE Smoke & Fire Curtains, Unit 3 Holbrook Commerce Park, Holbrook Rise, Sheffield, England, S20 3FJ Call 0114 251 4703 Email enquiries@blecurtains.com Visit www.ble-smokeandfirecurtains.com THE LEADING EDGE IN Smoke & Fire Curtains Office Tel: 0114 251 4703 Email: enquiries@blecurtains.com Website: www.ble-smokeandfirecurtains.com L&F A Lowe & Fletcher Group Company