Performance Evaluation of Mini-Mesh Fabric

Similar documents
Delivering the Comfort and Performance Your Customers Demand

Definition. Temperature regulation of the human body. Function and problems of clothing

HOT or COLD. Condensation Happens. Chill Out! Boost Productivity. Keeping Up to Standard AS SEEN IN. August 2004

PERFORMANCE TESTERS. Performance Textile Testing

100% Cotton Moisture Management. Cotton Incorporated, Cary, North Carolina ABSTRACT

15. Heat Pipes in Electronics (1)

TABLE OF CONTENTS. 1.0 INTRODUCTION Scope References Test Specimen Description Summary 1

HUMIDITY IN INCUBATION

LAB EQUIPMENT DETAILS

Impact of Relative Humidity on Loom Shed Efficiency

Exhaust. a) For an arbitrary ambient temperature develop an expression for Q chiller in terms of M amb and M total.

Thermodynamic Calculations of Two-Stage Vapor Compression Refrigeration Cycle with Flash Chamber and Separate Vapor Mixing Intercooler

Drop-in Testing of Next-Generation R134a Alternates in a Commercial Bottle Cooler/Freezer

Hydrostatic Head Tester TEST INSTRUMENT

Research-Scale Fire Performance Evaluation of a Wood Floor Joist/Tin Ceiling Panel Assembly

Can painted glass felt or glass fibre cloth be used as vapour barrier?

Usage of Woven Geo-Textiles in the Construction Subgrade in Flexible Pavements

Humidity Measurement Technology pros & cons. Helping you make a better measurement.

THERMAL ENGINEERING LABORATORY II. To train the students with principles and operation of thermal Engineering equipments.

DEHUMIDIFICATION DRYING OF SPRUCE STUDS. M. Y. Cech and F. Pfaff Eastern Forest Products Laboratory Ottawa, Ontario

The Potential of Osmotic Membrane Dehumidification

Thermo Scientific ULT Freezers: Superior Thermal Performance

THE ROLE OF DESICCANT IN INSULATING GLASS

Textile quality management. Mr Dale Carroll CSIRO, Textile and Fibre Technology

Heat Pump Water Heaters: Laboratory and Field Evaluation of New Residential Products

Heat and Smoke Release of a Ceiling-Installed Speaker

Mechanical Analysis Energy Savings Graph 1 Built-up Roof Graph 2 Green Roof

Chapter 5: Atmospheric Moisture

Textiles and moisture

Estimate the energy stored in unit gram of the food in J per gram.

How Wicks and Orientation

1 Determination of soil moisture content by theromogravimetric method.

EVAPORATION NEEDS ENERGY

FS 231: Final Exam (5-6-05) Part A (Closed Book): 60 points

TESTS OF ADSIL COATING

ME 410 MECHANICAL ENGINEERING SYSTEMS LABORATORY MASS & ENERGY BALANCES IN PSYCHROMETRIC PROCESSES EXPERIMENT 3

Hygrometry. The art or science of humidity observation

The Refrigeration Cycle

Changes of phase usually involve a transfer of energy Evaporation

Recommendations to retrofit positive existing installations running with HFCs (R404A & R507) RETROFIT POSITIVE & MEDIUM REFRIGERATING SYSTEMS

Combination unit to support instruction in Thermodunamics, Fluid Mechanics, and Heat Transfer

Thermal Performance of a Loop Thermosyphon

Thermal Properties and Temperature

Title: Indicative fire test. WF Report No: /A. Prepared for: Hoody Speaker Hoods Ltd

The Refrigeration Cycle

UNIQUE SCIENCE ACADEMY

AATCC TM Dimensional Changes of Fabrics after Home Laundering. AATCC TM Dimensional Changes of Garments after Home Laundering

RADIATION BLOCKAGE EFFECTS BY WATER CURTAIN

LABORATORY STUDY ON THE CONSOLIDATION SETTLEMENT OF CLAY-FILLED GEOTEXTILE TUBE AND BAGS

ARTI Charcoal Solar Briquette Dryer Improvement Project Report

EVALUATING LOOP HEAT PIPE PERFORMANCE IMPROVEMENT USING CIRCUMFERENTIAL GROOVES. Nadjara dos Santos, Roger R. Riehl

Refrigerator/Heat pump

SBS5311 HVACR II Experiment 2: Analysis of the Combined Rankine and Vapour Compression Cycle

Thick-Film Heater achieves Superior Performance in Thermal Response, Uniformity and Efficiency.

Humidity Measurement Technology Pros & Cons. Helping you make a better measurement.

WARRES No Page 1 of 27. Fire Resistance Test Generally In Accordance With BS 476: Part 22: 1987, Clause 5, on an Insulated Fabric Barrier

Types of Wicking Beds

Experimental Study to Evaluate Smoke Stratification and Layer Height in Highly Ventilated Compartments

Test Practice for Efficacy Evaluation of Encapsulate Solutions

Some Demonstration Experiments: Effects of Air Motion, Evaporation, and Pressure Changes on Temperature

COMPACT ADSORPTION CHILLERS WITH COATED ADSORBER HEAT EXCHANGERS

Brine Generation Study

Active Dry Air Venting for Water Contamination Control

Lab 1b Cooling Tower Performance and Sensors for Thermal-Fluid Systems

Standard Operating Procedure Glovebox and Thermal Evaporator

GEOTEXTILE DEFORMATION ANALYSIS OF GEOSYNTHETIC CLAY LINERS WITH FEM

Exercise 8: Soil Compaction. CE337, Section 006, Team 3. Experimental data acquired on April 16, 2015 by:

CONVECTION OVENS FOR FOOD SERVICE APPLICATIONS BLODGETT SHO-E

ME 410 MECHA ICAL E GI EERI G SYSTEMS LABORATORY

Title: Fire resistance test utilising the general principles of BS 476: Part 20: 1987 on four specimens of Uninsulated Air Valves.

CRAWL SPACE MOISTURE CONTROL - A Fundamental Misunderstanding By Peter Carpenter, member ASHRAE, SBCCI

STICK TO YOUR WORKOUTS, NOT YOUR CLOTHES. _

Welcome to the World of Aavid Heat Pipes

mysugarcase / MedAngel Test

LEAKAGE MONITORING OF SEAL PLUG FOR INDIAN PRESSURIZED HEAVY WATER REACTOR BY PSYCHOMETRICS ANALYSIS METHOD

MARIYA INTERNATIONAL SCHOOL AL-JUBAIL L-8 PHYSICS WORKSHEET(Heat & energy )

More heat energy means more of what type of energy? Does the mass change? So, what must change? What is the same in both containers?

Performance Enhancement of Mini Refrigerator with Phase Change Materials

PERFORMANCE OF GEOSYNTHETICS IN THE FILTRATION OF HIGH WATER CONTENT WASTE MATERIAL

ULT Freezer Performance Testing Emerson Design Services Network Project #

Performance of Geosynthetics in the Filtration of High Water Content Waste Material

An Experimental Study on Clothes Drying Using Waste Heat from Split Type Air Conditioner

Simco Calibration Laboratory

Development of a Psychrometric Test Chamber. Michael J. Swedish. Associate Professor Mechanical Engineering Department Milwaukee School of Engineering

SOILS SPEEDY 2000 MOISTURE TESTER MICROWAVE MOISTURE METER PERMEAMETER MODELS MODELS DESCRIPTION STANDARDS

IJARI. 1. Introduction: Heat Pipes. Volume 3, Issue 3 (2015) ISSN International Journal of Advance Research and Innovation.

An Introduction of Below-Freezing and Humidity Environment Controlling Technology Equipped on Brake Test Equipment

Humidity An excuse for the 80s

Electric radiator tests

CHAPTER 1 INTRODUCTION

MD and Its Impact on Lab Facilities

AUTHOR(S) Jan Ove Busklein CLIENT(S) Nittedal Torvindustri AS CLASS. THIS PAGE ISBN PROJECT NO. NO. OF PAGES/APPENDICES. Restricted 3C /1

Water Movement in Soils

MEASURING SPONTANEOUS HEATING TENDENCY OF ART MATERIALS

SOLAR COOLING TECHNOLOGIES

Select an agricultural ventilation fan for the

CHAPTER 7 PERFORMANCE ANALYSIS OF VAPOUR COMPRESSION REFRIGERATION SYSTEM IN HYBRID REFRIGERATION SYSTEM

Minutes with Lamp On

AIR CONDITIONING. Carrier Corporation 2002 Cat. No

Sodium Heat Pipes for Spacecraft Fission Power Generation

Transcription:

Performance Evaluation of Mini-Mesh Fabric Gajanan Bhat, PhD Professor and Director UTNRL The University of Tennessee, Knoxville, TN 37996 Phone: 865-974-0976 Email: gbhat@utk.edu

Objectives: The main objectives of this study were to test the Polar Skin Ice Sheet Mini Mesh, hereafter referred to as Mini Mesh. Main focus was to evaluate its permeability, wettability, drying characteristics as well as thermal comfort. The wettability and related characteristics were evaluated for water as well as the special Polar skin solution provided by PVL. For comparison purposes another fabric, that is the current industry standard, also referred to as the Sheet was also evaluated. The results are summarized in the following sections. Experiments and Evaluation The following tests were run under the listed conditions. Air Permeability: 10 tests were run for each sample using the Textest FX3300 Air Permeability Tester. Tests were conducted in accordance to INDA 70.1 in the laboratory conditions of 69.6 F and 24% Relative Humidity. Thickness: 10 tests were run for each sample using the TMI Model 49-70. Basis Weight: 10 circular samples with an area of 0.01 m^2 of each were taken to determine the basis weight. These were tested in accordance with INDA/WSP 130.1. Laboratory conditions during testing were 69.6 F, and 24% Relative Humidity. Hydrohead: 5 tests were run from each sample using the Textest FX3000 Hydrostatic Head Tester. The first set of samples was run using deionized water and the second set of mesh samples were done using the supplied Arctic Aqua. Tests were conducted in accordance with INDA/WSP 80.6. The laboratory conditions were 69.6 F, 24% Relative Humidity. ATS Absorption: 5 tests were run for each sample using the Sherwood Instruments ATS-600 with deionized water, in accordance with the suggested Test methods. The laboratory conditions were 69.6 F, 24% Relative humidity. Absorptive Capacity: Measured in accordance with INDA/WSP 10.1 were liquid absorptive capacity of fabrics. The laboratory conditions were 67.9 F, 51% Relative humidity. Drying Rate was tested in accordance with the military standards. Measured the sample dry weight and maximum liquid absorptive capacity (INDA WSP 10.1), then spread samples on glass plate in the lab fume hood. The weight of the samples was determined at set time intervals and the loss in water mass was plotted with respect to time.

Capillary Wicking: Tested in accordance with INDA/WSP 10.1 by measuring vertical capillary wicking of fabrics. Food coloring was added for visual reference. Cooling rate was measured by using thermocouples placed under the wet fabrics in an environmental chamber at a set temperature. Moisture Vapor Transmission Rate (MVTR) Evaporative dish method based on the British standard BS7209 was used to determine the MVTR of the two fabrics. The test specimens are sealed over the open mouth of test dishes that contained water. The adjacent figure shows the set up. We used three samples for each fabric. All the dishes are placed on a turntable, which slowly turns. The instrument was in a conditioned testing lab. The water in the dish was weighed before the start of the test and after 24 hours. The MVTR was calculated and reported as moisture vapor transmission in grams per square meter per day. Thermal Resistance of Fabrics Thermal resistance of fabrics was determined using a hot plate according to ASTM test method D1518-14. The figure below shows the sample on the hot plate and the control panel. This procedure measures the rate of heat transfer from a warm dry constant-temperature horizontal flat-plate up through the layer of the fabric to a relatively calm cool atmosphere. To get a comparison under actual use conditions, samples were also tested with ice water saturated fabric and the mesh with aqua that was kept in the freezer for two hours.

Cfm of Air Test Results Some of the basic properties of the two fabrics, Cotton sheet and the Per Vivo Mini-mesh are listed in Table 1 and then compared in the following graphs. Both the fabrics have same basis weight of about 2oz per sq. yd. However the properties that determine comfort and specific performance are significantly different due to their unique construction and compositional differences. The air permeability of the minimesh is more than three times higher than that of the cotton sheet because of the more porous construction (Figure 1). Also, the thickness of the minimesh fabric is about twice that of the sheet. The hydrohead, the pressure required to allow water permeation is comparable with only small differences. Table1. Summary of results from Air permeability, Weight, Thickness and Absorbency. 130 TC Cotton Sheet Mini Mesh 130 TC Cotton Sheet with Water Mini Mesh with Water Air Perm, Avg ± SD (cfm) 150.3 ± 3 518.4 ± 26 - - - Thickness, Avg± SD (mm) 0.265±.01 0.601 ± 01 - - - Basis Weight (gsm) 77.6 72.8 - - - Polar skin Ice sheet Mini Mesh Hydrohead, Avg± SD (mbar) - - 4.1 ± 0.2 3.6± 0.4 5.3 ± 0.3 Max ATS Absorption Avg (m/in 2 ) - - 0.037 ± 0.05 0.539 ± 0.05 - ATS Absorption Rate Avg± SD (g/s) - - 0.050 ±.0.03 0.013 +/-0.01 - Absorptive Capacity % 116.5%± 2.2% 368.1%± 7.4% 377.8%± 5.8% 6 5 4 3 2 1 0 Air Permeability 130 CT Cotton Sheet Mini Mesh Figure 1. Comparison of Air Permeability of Cotton Sheet and Mini Mesh.

LAC (% weight of liquid absorbed) Absorption, Drying and Cooling Performance Liquid absorption capacity measurement clearly showed that minimesh picks up about 250% more moisture than that absorbed by cotton sheet. Although initial absorption rate is slower with minimesh, the overall moisture absorption is very high. The absorption capacity of minimesh with arctic aqua is also high comparable to that of water absorption (Figure 2). The wicking rate is very high for minimesh compared to that for cotton sheet as seen from the data in Figure 3. This is due to the highly porous structure of the minimesh fabric. Liquid Absorptive Capacity (LAC) 400% 300% 200% 100% 0% 130CT Cotton Sheet Mini Mesh w/ H2O Mini Mesh w/ ArticAqua Figure 2. Liquid Absorption Capacity of Different Fabrics.

Figure 3. Capillary wicking rate of different fabrics. Drying rate and cooling effect due to drying of wet fabrics are shown in Figures 4 and 5. Whereas overall drying rates are comparable for the two fabrics initially, the cotton sheet seems to lose all the moisture in a short time, whereas minimesh, probably due to higher moisture content to start with, continues to lose moisture in a controlled rate for a long time, even for two hours. Cooling rate was measured by thermocouples placed on a glass plate and then placing the wet fabrics on them. The initial temperature in the chamber was ~41 C. As soon as the wet fabrics were placed on the plate the temperature dropped immediately by about 10 C (Figure 5). However, after about seven minutes, the temperature of the surface started going up with set sheet. The temperature was also increasing with minimesh saturated with water, although at a slower rate than that for sheet. The minimesh saturated with arctic aqua shows continuing cooling effect and even after 10min, the temperature does not go back up. Similar measurements were done with samples chilled with ice water or in a freezer and the results are shown in Figure 6.

Figure 4. Comparison of drying rates of the samples. Figure 5. Cooling rate due to wet fabrics.

Figure 6. Cooling rate measured using chilled fabric samples. MVTR Results Results from MVTR are shown in table below. Mini Mesh shows about 15% higher MVTR values. This is consistent with the other observations and the structure of the two fabrics. 132 TC Sheet 1296 Mini Mesh 1480.8 Thermal Properties Average Thermal transmittance for the fabrics are shown in the table below. The difference in thermal transmittance values between that of the sheet and mini-mesh are minimal when they are dry. However, the wet fabrics show a much higher difference between the two, with the minimesh showing significantly higher values. Test 130 TC Cotton Sheet Mini Mesh 130 TC Cotton Sheet w/ Water Mini Mesh w/ Water Mini Mesh w/ Artic Aqua Thermal Transmittance W/m2 K 0.000968 0.000924925 0.0026450 0.0034890 0.0030380

Thermal Transmittance Further, thermal transmittance change with time during comparable use conditions are shown in the figure below. In this case the values were measured for a minute with a gap of 15 seconds in between. The graph reflects the changes taking place in the first 10 minutes. Since the fabrics were wet, it took ~2-3 minutes for temperatures to stabilize. After that, data were collected. 0.004000 0.003500 0.003000 0.002500 0.002000 0.001500 0.001000 0.000500 0.000000 Average Thermal Transmittance Time 130TC Bedsheet w/ Ice Water Mini Mesh w/ Ice Water Mini Mesh w/ ArticAqua Structural differences between the fabrics IT is understandable that the differences in the observed properties are due to some structural differences in the fabric. In addition to the differences in the materials used, the yarn and fabric structures contribute to the observed differences in the properties. To elucidate these SEM photographs of the tow fabrics were taken and are shown below. The images clearly show that the minimesh has porous structure with a lot of capillaries for liquid uptake and holding capacity, and the cotton woven fabrics have relatively tighter yarn structure.

Cotton Woven Sample SEM images at different magnifications. A B C D

SEM Photographs at different magnifications for Mimi Mesh sample. A B C D