Hazardous Area Telephone Model EP600

Similar documents
Hazardous Area Ringdown Telephone

Explosion Proof Line Powered Telephone Ringer

Ring Detect Relays. Model RDR. Installation & Operation. Ph: \ \

Ring Detect Relays. Model RDR. Installation & Operation. Ph: \ \

Alarm Tone Generator Model AG17

Emergency/Help Point Analog Telephones & Correctional Analog Telephones

Emergency, Correctional & Institutional

FUTURE CALL. Loud Ringer Light Box FC OWNER S MANUAL AND OPERATING INSTRUCTIONS

Merge/Isolate Zone Control System

Certificate of Compliance

Environmental Monitoring SmartSlot Card

Intrinsically Safe, NEMA 4, Type 4X, IP67 Loop-Powered Meter

RELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION:

Panel Mounted Heat Exchangers by Dantherm, Inc.

INSTALLATION INSTRUCTIONS TALKBACK MODULE

User s Manual and Operating Instructions

Hazardous Area Ringers & Loudspeakers

3-6VFD Series Combination Flame and Explosion Proof Pilot Valve Enclosure

MODELS 304GC, 304GCX, 314GC, and 314GCX

RATIO:GUARD Model E-1S EC Monitor

Technical Specification VFD

GAS MONITOR Model Model

Surge Protective Devices Installation, Operation and Maintenance Manual. LowProfile Series: 080 and 120

! The Caution Symbol (exclamation point) alerts you to a "CAUTION", a safety or

SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. SS90-WPS MODEL A/B INSTALLATION MANUAL

User s Manual and Operating Instructions

Industrial Communications System Page/Party Flush-Mount Subset

OPERATOR S MANUAL MODEL AP15/AP15-1/AP15-2 PC-ALARM PANEL

MADE IN THE U.S.A. MODELS A/B INSTALLATION MANUAL

THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. MODELS A/B INSTALLATION MANUAL

CFC-FREE CB-60/CB-80 Cryobath Low Temperature Bath. Thermo NESLAB Manual P/N U00551 Rev. 04/03/00. Instruction and Operation Manual

Consumer Products Catalog

Firefly II Multi Voltage RELEASE DEVICES. Firefly II & IIB-MV INSTALLATION MANUAL

CurrentGuard TM. Installation, Operation and Maintenance Manual. CurrentGuardTM. Flush Mount. Surge Protective Devices A00

WATLOW IND. WATROD Circulation Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date: 6/11/2008 Rev: 2.00

DETCON MODEL AV1/AV2-C1D2M Hazardous Duty Class I. Div 2, Multitone Alarm Station

BLT-999W-2 Item # 60757

DIGITAL METERS Large Display Temperature Meters Instruction Manual

User Guide. Luxxor. 35 LED Light Source Fax: Tremont Street, Rochester, New York gradientlens.

CONTROL BE MADE CHANGES MAY NOT. Page 1

MODELS ASHP, ASHH, ASUP, and ASUH

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS

Beacon 800 Gas Monitor Operator s Manual

CELDEK Evaporative Cooler Module Installation, Operation, and Maintenance Manual. CELDEK Evaporative Cooler

Noran Tel. FUSE PANEL Technical Practice N NCY 2/2 KLM and 4/4 GMT NEBS Level 3 Certified

COMM SAT SPEAKER SYSTEM OWNER'S MANUAL

SUBLIME Instruction manual

ATKINSON DYNAMICS SPEAKERS

GE Security Fire & Life Safety F-DACT(F) Digital Alarm Communicator Transmitter Installation Sheet

SAFETY INFORMATION AND WARNINGS

Feel Perfect. Heated Throw. Instruction Booklet. TR6300 Luxe Faux Fur. Please read these instructions carefully and retain for future reference.

LC3000 Level Controller Installation and Maintenance Instructions

36 & 48 E-Z Cone Fan. Installation & Operator s Instruction Manual (Direct Drive)

BLOWER ACCESSORY MODEL #FIB100 Español p. 17

MODEL AV2-C1D1M Hazardous Duty Class I. Div 1, Multitone Alarm Station

Figure 1. Figure 2. See notes 1 and 2 below.

WATLOW IND. WATROD Modular Duct Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2

3226 Trunk Port FXO Doorphone

Instruction Manual. Alarm Unit For Low Gas Level # Read manual before use! Observe all safety information! Keep manual for future use!

XT Series Thermostats

VM-WA525-S / VM-WA65-S VM-WA8-S SHAKER SERIES 2-WAY HIGH PERFORMANCE IN-WALL SPEAKER

WATLOW ELECTRIC MFG CO. FIREBAR Screw Plug Installation & Maintenance Manual I&M NUMBER: Page: 1 Date: 11/25/2013 Rev: 4.

Model: C C Ambassador 20. Automatic Carpet Scrubber OPERATION SERVICE PARTS CARE

Environmental Monitoring Card

FUSE PANEL Technical Practice N N/L9 10/10 GMT NEBS Level 3 Certified

ELECTRIC FIREPLACE HEATER WITH SINGLE GLASS DOOR

GETTING STARTED GUIDE NI RTD, 0 Ω to 400 Ω, 24 Bit, 400 S/s Aggregate, PT100

Installation and Operation Guide

Sentry LIQUID LEVEL ALARM MODEL 100 OPERATING MANUAL.

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:

Tek-ENTRY Telephone Entry System

COMSPHERE 48 Vdc CENTRAL OFFICE POWER UNIT

INSTRUCTION MANUAL (English version) Water still

OKB, OKD, & OKH Series

P/N CC-100. Coolant Circulator. Operation manual

HI Industrial Utility Heater HI Soleus Air International

Quick start guide. SB3014-WM DECT 6.0 expansion wireless mic for use with AT&T model SB3014

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS PENTAIR CLEAN AIR SYSTEMS

INSTALLATION, OPERATION AND MAINTENANCE

EQUIPMENT SPECIFICATION. GAI-TRONICS ADDRESSABLE AMPLIFIED SPEAKER and AUDIO MESSENGER INTERFACE PRODUCTS

SHORT CIRCUIT ISOLATOR TO NEXT COMPONENT REQUIRING POWER TO NEXT KEYPAD (** IF REQUIRED) STROBE RELAY MODULE KEYSWITCH ISOLATION MODULE STROBE

KPHE24 SERIES WATER-TO-AIR HEAT EXCHANGER

LED IMPORTANT SAFETY INSTRUCTIONS

MODEL LP3 INSTALLATION AND SERVICE INSTRUCTIONS FOR STREAMLINE LP3 STROBE LIGHTS

PPI PPI PPI SERVICE PPI PPI PPI PPI PPI PPI CAUTION! PPI

Owner s Manual Phoenix Aquadry TX 200

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

OPERATION MANUAL MODEL & ACCELEROMETER

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

FTC-350A. ual. Instruction and Operation Manual. Thermo NESLAB Manual P/N Rev. 11/08/00

AA-480-XX OUTDOOR THERMOELECTRIC COOLER ASSEMBLY USER S MANUAL

NESLAB CB 60/CB 80 Cryobaths. Operation. Product Service Information, Applications Notes, MSDS Forms, .

OWNER S MANUAL MHSCB1-01

Roanoke 48 in Ceiling Fan Owner s Manual. Roanoke Ventilador de Techo de 1,22 m Manual del Propietario

Owner s Manual PCS PRO

ELECTRIC FLAT PANEL FIREPLACE HEATER

INSTRUCTIONS FOR TAL SERIES VACUUM HOPPER LOADER

AMERIPHONE products are manufactured by Walker, A Division of Plantronics, Inc Western Avenue, Garden Grove, CA (800) VOICE

52 CEILING FAN. Owner s Manual Models #50336, 50337

Ultimate In-Wall. Reference Line Source III. Congratulations. Owner s Manual

Transcription:

R Industrial Communications Worldwide Hazardous Area Telephone SN#W GUARDIAN TELECOM INC. EP600 TELEPHONE TELEPHONE FOR USE IN LR65547 HAZARDOUS LOCATIONS CLASS I, DIVISION 2, GROUPS A, B, C, & D CLASS II, DIVISION 2, GROUPS F & G CLASS II, DIVISION 1, GROUPS E, F, & G (CSA only) CSA ENCLOSURE TYPE 3R DOC & FCC APPROVED L.N. 21 CAT. NO. STYLE 12 R.E.N 0.4A SEE USER GUIDE FOR INSTALLATION CAUTION: ATTENTION: MADE IN CANADA KEEP COVER TIGHT WHILE CIRCUITS ARE ALIVE. FIELD REPAIR NOT POSSIBLE. GARDER LE COUVERCLE BIEN FERME TANT QUE QUE CIRCUITS SONT SOUS TENSION. CET APPAREIL NE PEUT ETRE REPARE A PIED D'OEUVRE. LISTED 13X8 P000115 Rev. E 11/23/2004 10:00 7552-10th Street N.E. Calgary, Alberta, Canada T2E 8W1 Ph: 403.258.3100 \ email:info@guardiantelecom.com \ www.guardiantelecom.com

Table of Contents Package Contents...2 Overview...3 Features...3 Installing the EP600...5 Maintenance...5 Operation...6 Setting Tone/Pulse Operation...6 Engineering Specifications...7 Warranty...9 Disclaimer...9 Warning...9 Service Telephone Number...9 Feedback...9 Guardian Product Return...10 Table of Figures Figure 1 - Overall Dimensions...4 Figure 2 - Installation...4 Figure 3 - Setting Tone/Pulse Operation...6 (1) EP600 Telephone (1) Installation & Operation Manual Package Contents Page 2

Overview Hazardous Area Telephone The EP600 Telephone is designed to provide safe, reliable communication in Class 1, Division 2, hazardous locations. The unit is housed in a rugged, weather and corrosion resistant enclosure that ensures operation in severe conditions. Features Enclosure weather tight, rugged Valox & steel spring loaded hinged door stainless steel mounting bracket Keypad standard 3 x 4 matrix Magnetic Reed Hook Switch no moving parts Surge Arrestor prevents damage to the electronic circuitry in the event of a high voltage spike on the telephone line Wall Mount easily mounted on any sturdy vertical structure Noise Reducing Microphone allows a high level of intelligibility in locations with high background noise Tone (DTMF) Operation factory set to tone (DTMF) dialing can be ordered set for pulse dialing or configured in the field Heavy Duty Handset Cord withstands severe use Hearing-Aid Compatible compatible with inductively coupled hearing-aid devices Page 3

SN#W LR65547 L.N. 21 CAUTION: CLASS I, DIVISION 2, GROUPS A, B, C, & D CLASS II, DIVISION 2, GROUPS F & G DOC & FCC APPROVED CAT. NO. STYLE 12 R.E.N 0.4A SEE USER GUIDE FOR INSTALLATION MADE IN CANADA KEEP COVER TIGHT WHILE CIRCUITS ARE ALIVE. FIELD REPAIR NOT POSSIBLE. ATTENTION: GARDER LE COUVERCLE BIEN FERME TANT QUE NE PEUT ETRE REPARE A PIED D'OEUVRE. QUE CIRCUITS SONT SOUS TENSION. CET APPAREIL R 13X8 LISTED SN#W TELEPHONE FOR USE IN R LR65547 HAZARDOUS LOCATIONS LISTED CLASS I, DIVISION 2, GROUPS A, B, C, & D 13X8 CLASS II, DIVISION 2, GROUPS F & G CLASS II, DIVISION 1, GROUPS E, F, & G (CSA only) CSA ENCLOSURE TYPE 3R DOC & FCC APPROVED L.N. 21 CAT. NO. STYLE 12 R.E.N 0.4A SEE USER GUIDE FOR INSTALLATION MADE IN CANADA CAUTION: KEEP COVER TIGHT WHILE CIRCUITS ARE ALIVE. FIELD REPAIR NOT POSSIBLE. ATTENTION: GARDER LE COUVERCLE BIEN FERME TANT QUE NE PEUT ETRE REPARE A PIED D'OEUVRE. QUE CIRCUITS SONT SOUS TENSION. CET APPAREIL Guardian Telecom Inc. 9.7" [246mm] 8.8" [224mm] 12.0" [305mm] GUARDIAN TELECOM INC. EP600 TELEPHONE 11.8" [300mm] 2.9" [74mm] 3.8" [97mm] 3.9" [99mm] 14.0" [356mm] Figure 1 - Overall Dimensions 6.0" [152mm] GUARDIAN TELECOM INC. EP600 TELEPHONE HAZARDOUS LOCATIONS TELEPHONE FOR USE IN CSA ENCLOSURE TYPE 3R CLASS II, DIVISION 1, GROUPS E, F, & G (CSA only) 13.0" [330mm] GROUND GREEN TIP & RING CONNECTIONS Figure 2 - Installation Page 4

Installing the EP600 Declassify the hazardous location before proceeding with any installation or electrical wiring. The EP600 is set to tone dialing when shipped. If pulse dialing is required see the section on Setting Tone/Pulse Operation. Follow all appropriate electrical codes and use only approved electrical fittings for the installation. Choose a wall location that is free of obstructions and permits space for ½ NPT conduit runs. Ensure mounting can support 5 lbs (2.3 kgs) and any foreseeable additional load. Ensure that none of the electrical connection circuits are live. Use the template provided or the stainless steel mounting bracket to locate and drill holes for mounting screws. Secure the unit to the wall. Open the door and remove the four #8 Philips drive screws on the access plate. Connect an approved earth ground to the center post of the surge arrestor. Connect the wires from the PABX or CO to the tip and ring connections on the surge arrestor. (The unit is not polarity sensitive.) Ensure all connections are tight, then replace the access plate and secure with the four #8 Philips drive screws. Apply power to the system. Test the unit by calling from another unit on the exchange. Caution: Installation or electrical wiring in a hazardous location could result in serious injury to personnel or damage to property. See: Setting Tone/Pulse Operation See: EP600 Drawing, Figure 1 - Overall Dimensions. See: EP600 Drawing, Figure 1 - Overall Dimensions. Tip: Use #8 or M4 screws to secure the unit to the wall. See: Figure 2 - Installation Maintenance Declassify the hazardous location before proceeding with any maintenance or repairs. To maintain hazardous area compliance the only field adjustment permitted is to change the tone/pulse setting. All other repairs or alterations must be carried out by Guardian Telecom or an Authorized Service Depot. See: Warranty and Guardian Product Return Page 5

Operation Once your Telephone has been properly installed and energized, operation is identical to most other single line telephones. Setting Tone/Pulse Operation Ensure that none of the electrical connection circuits are live. Loosen the five captive screws in the faceplate and swing the faceplate to the left. If the set is installed on a vertical surface the faceplate will stay open like a book in this position. Take care not to disturb the internal wiring. Set the Tone/Pulse jumper for the desired operation. For pulse, set jumper between the center pin and the P, for tone set it between the center pin and T. Replace the faceplate. Check the set visually for loose screws and trapped wires. Check that the handset hangs freely in the cradle and that the handset cord is not trapped by the door. Check that the faceplate is snug to its gasket, paying particular attention to the area around the cradle. Check that the door closes flush to the housing. Apply power to the system. Test the unit by calling to and from another unit on the exchange. See: Figure 3 - Setting Tone/Pulse Operation HS HK RINGER TONE PULSE JUMPER P T TIP SPARE RING SPARE Figure 3 - Setting Tone/Pulse Operation Page 6

Engineering Specifications Electrical Performance AUDIBLE RANGE FREQUENCY RESPONSE DIALING METHOD TRANSMIT OBJECTIVE LOUDNESS RATING (TOLR) RECEIVE OBJECTIVE LOUDNESS RATING (ROLR) SIDE TONE OBJECTIVE LOUDNESS RATING (SOLR) RINGER OUTPUT FCC RINGER EQUIVALENCE NUMBER (REN) 300-3400 HZ DTMF TONE or 40/60 PULSE AT 10 PPS -40 +/- 3 db 47 +/- 3 db 10 +/- 4 db 75 db Maximum 0.7 B (mechanical bell) SET IMPEDANCE MAXIMUM LOOP Electrical Requirements RINGER SENSITIVITY LINE VOLTAGE LOOP CURRENT 600 OHMS NOMINAL 15 KFt (4.6 KM) 40-100 V, 16-25 HZ 24-56 VDC 20-120 MA CONNECTION METHOD SURGE ARRESTOR Environmental WEATHER AND CORROSION RESISTANT ENCLOSURE 3R TEMPERATURE -40 O TO +60 O C (-40 O TO +140 O F) HUMIDITY 0 TO 95% RH DUST RESISTANT Mechanical HOOK SWITCH (CRADLE SWITCH) LIFE BODY CONSTRUCTION FACEPLATE DIMENSIONS (H x W x D) NET WEIGHT HANDSET MATERIAL MICROPHONE OPTIONAL MICROPHONE RECEIVER STANDARD MOUNTING CONNECTION FITTINGS HARDWARE MATERIAL CLASS II HAZARDOUS LOCATIONS >1 000 000 OPERATIONS GE VALOX 357 R ENGINEERING POLYMER STAINLESS STEEL 14 X 9.7 X 3.9 INCHES (356 X 246 x 99 MM) 5 LBS (2.3 KG) HIGH IMPACT ABS NOISE REDUCING ELECTRET NOISE CANCELING DYNAMIC HEARING AID COMPATIBLE VERTICAL WALL 1/2 NPT CONDUIT HUB STAINLESS STEEL Page 7

Compliance CANADIAN STANDARDS ASSOCIATION (CSA) STYLE 12 STYLE 21 STYLE 22 UNDERWRITERS LABORATORIES (UL) STYLE 12 STYLE 22 CONFORMITÉ EUROPÉENNE (CE) STYLE 12 ENCLOSURE REFERENCE NUMBER: LR65547-23 CLASS I, DIVISION 2, GROUPS A, B, C AND D CLASS I, ZONE 2, GROUP IIC CLASS II, DIVISION 1 & 2, GROUPS E, F AND G CLASS II, DIVISION 1, GROUPS E, F AND G CLASS II, DIVISION 2, GROUP G LISTED 13X8 & E117495 CLASS I, DIVISION 2, GROUPS A, B, C AND D CLASS II, DIVISION 2, GROUPS F AND G CLASS II, DIVISION 2, GROUPS F & G EMC DIRECTIVE 89/336/EEC LOW-VOLTAGE DIRECTIVE 73/23/EEC ATEX DIRECTIVE 94/9/EC CSA 3R Figure 4 - I.D. and Compliance, (Style 12 only) Page 8

Warranty Guardian Telecom warrants your product to be free of defects in material and workmanship for a period of one year. Guardian Telecom will repair or replace any defective unit that is under warranty This warranty is null and void if any non-authorized modifications have been made to this product, or if it has been subjected to misuse, neglect, or accident. This warranty covers bench repairs only; such repairs must be made at Guardian Telecom or an authorized service depot. Guardian Telecom is not responsible for costs incurred for on-site service calls, freight, or brokerage. A return authorization must be obtained prior to warranty claims or repairs. Disclaimer The products covered by this manual are designed for use in Industrial Environments and/or Hazardous Locations. Due to the range of possible applications for these instruments the manufacturer will not be responsible for damages or losses of any kind suffered as a result of the use of this product, including consequential damages. Warning For the purposes of installing the product and replacing fuses this device may be opened and reassembled by qualified personnel, following the instructions in the product manual. In the cases of explosion proof and hazardous area devices it is imperative that mating surfaces be clean and undamaged prior to reassembly and that fasteners be made up to the specified torque. 1-800-363-8010 High voltages may be present in this device when connected to telephone wiring Service Telephone Number Guardian Telecom provides a customer service telephone number which is toll-free within North America. If you need assistance when installing or operating this product, please call the toll-free telephone number between regular business hours (8:00AM-5:00PM), Mountain Standard Time. If you are calling outside of regular business hours, please leave a detailed message, and a member of Guardian Telecom s Service Department will return your call as soon as possible. If your product requires service, Guardian personnel will supply you with an RMA (return materials authorization) number over the telephone or through our web site product return page. This number must be included with your return address and the name of the person to contact. Guardian Telecom Inc. 7552-10th Street N.E. Calgary, Alberta, Canada T2E 8W1 Toll-free 1-800-363-8010 Ph. (403) 258-3100 Fax. (403) 253-4967 www.guardiantelecom.com Feedback Guardian Telecom continually strives to make reliable, durable, and easy to use products. If you, as an installer or user of our equipment, have any suggestions for improvements to this or any of our products or documents, including this manual, we would appreciate hearing from you. Page 9

Guardian Product Return Guardian products have been quality tested and are in full working order when shipped from the factory, given the rugged nature of these products, shipping is not expected to damage a unit. In the unlikely event of a malfunction, Guardian follows the three step procedure below. Step I - On-Site Correction The most common source of difficulties with a new product is improper installation in one of two ways: incorrect wiring connections or connection to an incorrect power source. Product wiring needs to be properly connected to the on-site wiring. Correct wiring instructions are shown in the user manual included with the product. Connecting a telephone to a standard power source, rather than tip & ring, will blow the telephone s internal, user-replaceable fuse. In the event of fuse burn-out, disconnect the telephone from the power source, replace the fuse, and reconnect following the wiring diagrams provided with the product. Step II - Return Materials Authorization (RMA) When a product has been installed following user manual instructions, and the unit fails to operate, the user must contact Guardian Telecom to obtain authorization to return the product. This can be done by done by completing a RMA form online at www.guardiantelecom.com, or by calling the service telephone number given in this manual. After providing information on the product, the owner and the nature of the problem, Guardian will issue a RMA number, to be shown on documentation returned with the product. In addition to the RMA number, shipping documents should include name, address and telephone number of the owner along with contact information for the person responsible for the repair and/or the user who identified the malfunction. (Where a product is being returned for repair from outside of Canada, customs documentation must show the product s serial number, date of export [date of purchase], and a notation that the equipment is: Canadian goods returning. ) Step III - Factory Authorized Service Once received, each product is carefully inspected and tested. If the product is under warranty, repairs are completed and the product returned to the owner, generally within five working days of receipt by the factory. A product that has been subjected to misuse, neglect or accident or is beyond the warranty period will be evaluated. The service department will provide the owner s representative with a repair cost estimate. Once approved, repairs are completed and the product returned, generally within five working days. Page 10

Notes: Model No. Part No. Serial No. Date of Purchase Page 11

7552-10th Street N.E. Calgary, Alberta, Canada T2E 8W1 Toll-free 1-800-363-8010 Ph. (403) 258-3100 Fax. (403) 253-4967 www.guardiantelecom.com E-mail: sales@guardiantelecom.com Industrial Communications Worldwide Guardian Telecom Inc. 2004