MOVING FILTER AIR MONITOR ALPHA, BETA/GAMMA PARTICULATES

Similar documents
MOVING FILTER AIR MONITOR ALPHA, BETA/GAMMA

AIR or STACK MONITOR NOBLE GAS, GROSS BETA-GAMMA PARTICULATE, & IODINE. Optional Alpha, Tritium, Carbon-14

PORTABLE ISOTOPE IDENTIFIER Search Tool / Sample Counting System

HIGHLY SENSITIVE FOR NUCLEAR POWER PLANTS Real-Time Continuous Water Monitor

SEAWATER RADIATION DETECTION SYSTEM WATER PROTECTION

NEXT GENERATION DRINKING WATER RADIATION SAFETY MONITOR

NEX-BETA-ABG FACILITY Drinking Water Safety Monitor

SCM. Micro. Streaming Current Monitor. Analyzer. Sensor/Sampler with light shield removed. The Analyzer. Instrument Overview

LAUNDRY MONITORING SYSTEM Model # LIM-64S

PORTABLE or FIXED PERSONNEL & VEHICLE MONITOR

Identify the following features and specifications for the ESP1

ß-Aerosolmonitor FHT 59 C

Ronan Model X96S Series Density System

COUNTING ROOM EQUIPMENT RCT STUDY GUIDE

Portable Alpha/Beta Continuous Online Air Monitor (CAM)

Thermo Scientific Aerosol Monitor FHT 58 S Technical Specification ZT-221E

Ronan Model X96S Series Weighing System

Radiation Monitoring System RMS

AS950 REFRIGERATED SAMPLERS

CTBTO ULTRA HIGH VOLUME AIR SAMPLER GLOBAL AIR SAMPLING SYSTEM UHV600 SERIES: 15 H.P. SYSTEM UHV600-15HP AND UHV600-15HP-20850

AERIAL RADIATION DETECTORS

AERIAL RADIATION & CHEMICAL DETECTION SYSTEM. DroneSENSOR TM Series. Particulate Alpha, Beta, Gamma & Airborne Chemicals

AM-806. Waste/Door Radiation Monitor OPERATIONS MANUAL

Aer 5200/5300. Data Sheet Aer 5200/5300. Portable Alpha/Beta Continuous Online Air Monitor (CAM) Closer to your application

Radiation Monitoring Systems

AS950 ALL-WEATHER REFRIGERATED SAMPLERS

Centro-Matic Automated Lubrication Systems System Controls

A bright alpha numeric display and the simplified keypad (three buttons) allow the operation even under harsh conditions.

Comprehensive applications of the gas flow proportional counters for Radiological Surveillance

Advanced Laundry Chemical Dosing System for Single and Multi-Washers

Radiation Monitoring Equipment

RAM GENE-1 ERK. Contamination & Radiation Meter. Operating Manual. Document #PRIR90N2.DOC Version 2.2 October 2009

Use this Specification Template to develop a specification to be used for requesting a quote or defining a job work description.

Model 1062 Environment Monitor

LOW MINIMUM DETECTABLE ACTIVITY (MDA)

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

Industrial Freezer Sales A division of IDS 5311 Derry Avenue Building D Agoura Hills CA Phone (818) Fax (818)

Constant climate chambers

USER GUIDE. Paperless Humidity/Temperature Chart Recorder. Model RH520A 21.2 C 13:

Measurement Devices. Topic 5 - Audio 56

RAM GENE / RAM GENE-1

Nuclear Associates

IRtech. E instruments. IRtech Radiamatic IR20 LS series. Infrared Technology

Ronan Model X90 Series Point Level Monitor

User Manual. Humidity-Temperature Chart Recorder. Model RH520

DT968C C.T. BATH CONTROLLER

3500/61E & 3500/67E Temperature Monitor

Tri-Tech Medical Inc.

stationary dose rate measuring systems

Introduction Portable Meters Transmitter Probes RELATIVE HUMIDITY

HIGH CAPACITY PRODUCT LINE

Constant climate chambers

icam -HD High Flow Rate Alpha/Beta Air Monitor Radiation Safety. Amplified. DESCRIPTION KEY FEATURES BENEFITS OPTIONS

Radioactive Contamination Monitor

Advanced Test Equipment Rentals ATEC (2832)

RF SCOUT PLUS INSTRUCTION MANUAL. Dielectric, LLC 22 Tower Rd. Raymond, ME Phone: January 2015, Rev B 1

Process Alarm Module RTA 421

Self-contained and intrinsically safe wireless stand-alone multi-point gas detector.

ORTEC DSPEC LF. High-Performance Digital Signal Processor for Gamma Spectroscopy. ... in a compact package at an economical price.

MODEL 1925-PR TRITIUM HEAVY WATER LEAK DETECTOR

Constant climate chambers

DFM. flow pressure temperature MULTI PARAMETER DIGITAL MASS FLOW METERS. Totalizer. Interface

Liquid Helium Level Instruments

WASTEWATER Online UV%Transmission Analyzer

High performance dry leak detectors ASM 182 TD+ ASM 192 T2D+ HELIUM LEAK DETECTORS 297 > 308

Fundamentals is subdivided into Sources of Radiation, Biological Effects, Mathematics, Chemistry, Physics, and Units and Terminology.

Contamination Meter Users Manual

Section PERIMETER SECURITY SYSTEMS

HIGH CAPACITY PRODUCT LINE

Table of Contents. Page Quick Set-up Instructions 1. Theory of Operation 2. Specifications 3. TM 1003W Controls and Connections 4

Advanced Autoclave Controller with Recording + 4 Channel Mapping + Pressure Indication with PC Software & Printer Module

Upright Chromatography Refrigerators

Automatic Isokinetic Sampler ST5

Turnkey Solutions for Radiation Protection in PET Laboratories R A D I A T I O N P R O T E C T I O N

Constant climate chamber with humidity

TRITIUM IN WATER MONITOR REAL TIME CONTINUOUS Model # LIQ-X-(H3)

Laser Scan Micrometer Page 418. Laser Scan Micrometer Page 423

D3000. Installation & Setup Guide

ACS-30 MULTIPOINT COMMERCIAL HEAT-TRACING SYSTEM PRODUCT OVERVIEW. ACS-30 System

A New Standard of Excellence

Area Monitor/Frisker Count Rate Meter Victoreen

Portable Instruments For First Response & In-Situ Analysis of Radiation

Constant climate chamber with ICH-compliant illumination

HOBO U14 Data Logger User Manual

Temperature Data Logging

Quality Assurance/ Quality Control. Topic 4 - Audio 46. Key Points

Cimco Series 21. Series 21 - Specifications INDEX. Description. Operational Specification 2

Alarm Tone Generator Model AG17

Portable Survey Instruments NISP-RP-01

Refer to Bulletin E-1101 for detailed information on the FLAME-MONITOR System.

Kata products Kata DGM-1500 Turva

ND4000 Manual Marine Hydraulics

SENSITIVE ENOUGH TO DETECT RUNOFF CHANGES IN GROUNDWATER TRITIUM PLUMES

Omniguard 4: Features

CONTAMINATION MONITORING INSTRUMENTATION RCT STUDY GUIDE LEARNING OBJECTIVES:

WinAMS AMS-4 Monitoring System for Windows

EZT Series Integra Med Touch Area Alarm & Zone Valve Box with EZ Backfeed

HOBO U30 Remote Monitoring Systems

Laboratory Impex Systems Ltd

Remote. control unit. accessories. Leak detector SmartTest. Remote control unit for SmartTest. Remote. Vacuum analysis and measurement

Transcription:

FEATURES: MOVING AIR FILTER AIRBORNE ALPHA LESS RADON AND BETA/GAMMA PARTICULATES RUGGED, 100% DUTY CYCLE SETTABLE ALARM HIGH THROUGH-PUT UNATTENDED OPERATION 12 WEEKS PRINTED RECORD (Optional) 4 CHANNEL AIR MONITOR SAAM-4HVM Alpha Short/Long Life Beta Short/Long Life 2 CHANNEL AIR MONIOR SAAM-1 Alpha & Beta-Gamma COUNTS SEPARATELY AND SIMULTANEOUSLY USB and/or ETHERNET OUTPUT Filter Paper Roll APPLICATION: The SAAM Series Monitors are used for monitoring effluent from radioactivity utilizing or producing facilities either directly at the stack or other outlet or at the property boundary. The SAAM Series are designed to provide a complete record of activity for up to 90 days of unattended operation. This instrument automatically advances the filter. This avoids frequent manual filter replacement. Alarms are preset by user. OPTIONS: 1. Single Channel Analyzer window(s) specifically for Pu-239, and U-238 and/or other nuclides. 2. Clock and calendar give date and time of each reading. 3. Helium Flush for Alpha Spectroscopy.

DESCRIPTION: MOVING FILTER AIR MONITOR The SAAM-4HVM is a four channel air monitor for simultaneous measuring of gross Alpha, Beta/Gamma; short and long life particulates. The SAAM-1 is a two channel monitor for measuring gross Alpha & Beta/Gamma. Like all of the SAAM series, these are continuous duty, high capacity, rugged skid or caster-mounted systems. Electronics are microprocessor with color LCD display. Also preamps etc. are plug-in modules allowing change or addition of function as needed and allowing rapid repair by substitution of modules in the field. Shields are void free lead encased in welded steel and with stainless steel liners for a long, useful life and easy decontamination. Filters are easily changed via quick disconnect, O-ring sealed filter holder. Shield can be opened for filter change or cleaning with minimum effort. All shield connections and openings are sealed against air leaks. The air moving system is based on a high capacity air pump capable of delivering 4 cfm with options up to 30 cfm free air and a real time electronic flow meter. The flow meter feeds directly into the TAquire software data analysis for more accurate calculation of airborne concentration and total activity. The entire system is mounted in a self-contained rugged cabinet and comes complete with all cabling and connectors in place ready to operate. The standard unit is operated from 120 V single phase, 60 Hz; 220 V optional, 50 or 60 Hz. Safe & easy access for filter paper exchange. The modular system is covered by T/A s unique exchange warranty, in addition to the full one year warranty covering all T/A products. SPECIFICATIONS: MODEL SAAM-1 SAAM-1 SAAM-4HVM SAAM-4HVM Channels: 1 2 1 & 2 3 & 4 Physical Form: Particulates Particulates Particulates Particulates Activity Detected: Alpha Beta/Gamma Alpha Short & Long Life Beta/Gamma Short & Long Life Detector Type: Scintillator (Optional Solid State) Thin Window GM Solid State Thin Window GM Size: 2 Diameter 2 Diameter 1 Diameter 2 Diameter Model: ZnS (Ag) Optional Solid State) T-1190 SS-A1 T-1190 Filters Media: Moving Filter Moving Filter Moving Filter Moving Filter Size: Construction: Standard Shielding: Optional Shielding: 75mm x 100 meters None 3 (Pb) Lead ½ Steel 1 (Pb) Lead None 1 (Pb) None 3 (Pb) Lead Sensitivity: 2 x 10-13 μci/ml 2 x 10-13 μci/ml 2 x 10-13 μci/ml 2 x 10-13 μci/ml

SPECIFICATIONS (continued): ELECTRONIC SYSTEM DESCRIPTION: Micro-processor includes: CPU with data acquisition Keyboard High resolution, color Color LCD Monitor Mouse Audio Manuals Onscreen Graphics (Built-in Printer Optional) Data Storage: Non-volatile memory 1 year. Data stored every 2 minutes all year. 1 terabyte hard drive: Stores programs, plus room to add additional new software functions in the future. Energy Analyzer: Fully adjustable single channel analyzer with independent High Voltage power supply. Power Supply: 1 ea. MVR-5R High Voltage Supply: Separately variable for each detector from 0 to 1500V. Display Monitor: Showing both real time concentration and accumulated dose for each channels. Accuracy: ±10% except for resolution loss and statistical variation. Background: Compensation for Radon daughters & Gamma Background SPECIALIZED AIR MONITOR SOFTWARE. User settable Engineering Units. Calibration feature allows readout directly in Ci/cc or cps/m or other units. Integrates results over an eight hour, or 24 hour interval. MENU OPTIONS: 1. Modify shift length 2. Change filter 3. Configure energies 4. Set alarms 5. Start shift 6. Calibration ALARMS: Alarms pre-settable to any trigger level. Low Level Alarm: Automatic Reset High Level Alarm: High level alarm remains activated until RESET is pushed. Alarm Indication: Red-High Level, Amber-Low Level Audio: 1000 Hz, greater than 80 db. Also see Safety Features below. AIR MOVING SYSTEM: Air pump: Pump Drive Motor: Flow Rate: Inlet and Outlet: Extremely rugged continuous high capacity Positive displacement pumping system. Ultra Low Noise Pump 1 HP, 50/60 Hz, capacitor start, induction run. Electronic mass flow meter continuously informs analysis system. 20 foot 3/4 hose inlet: 20 foot 1 hose outlet. Length may be extended.

CONTROLS: System: ON-OFF Air: ON-OFF MOVING FILTER AIR MONITOR Alarms: (each channel) High Level Alarm: Set (each channel) High Level Alarm: Reset (each channel) Low Level Alarm: Set (each detector) Voltage: Set (each detector) Energy Threshold/Window: Set Built-In Diagnostics: Function of: Pump, Filter, Alarms STANDARD SPECIFICATIONS: High Voltage Supply: Separately variable from 0 to 1,5000 VDC at 200 μa on scintillation or proportional channels. LCD Color Monitor: Accurancy: Alarms: Low Level Alarm: High Level Alarm: Alarm Indication Lights: Audio: Outputs: Standard Installation: Special Safety: Power: OPTIONAL: 17" Monitor shows both real time concentration & accumulated dose for all Channels +/- 10% except for resolution loss and statistical variation Alarms are pre-settable to any trigger level Automatic Reset High level alarm remains activated until RESET button is pushed 6 Lights Red-high level; Amber-low level count for each channel, plus more indicators shown on LCD Monitor. 1,000 Hz, greater than 80 db Alarm Condition Outputs: 1. Logic Level Signal 2. Contact Closure or Opening Ethernet USB Cabinet: heavy gauge steel. Skid or caster mounted Five inch ball bearing casters (4 each). Two of these are full 360 degree swiveling. Loss of system vacuum air flow alarm with relay switch closure. Loss of signal alarm. All system circuits fused. 120 VAC 220 VAC; optional 50/60 Hz Thermal protection on motor.

OPTIONS: Up to 3 Channels of 4-20mA Chart Recorder Drive or Communicate with the computer Skid Mount Grab Sample Port Available without air mover or with alternate air movers. Broader range 12 decades. Different detector types. Positive displacement of Roots Blower. Push-button Detect & Test sources (License exempt quantities) Flow rate can be increased to 30 cfm with larger pump and minor changes in the plumbing Lighter system with less Shielding eg: 1 thick. WEIGHT, DEMENSION, SHIPPING: SAAM-4HVM Dimensions: 29'' wide x 31'' deep x 41'' high - exclusive of casters. Weight: 1600 lbs. Shipping Weight: 1750 lbs. SAAM-1 Dimensions: Weight: Shipping Weight: 24'' wide x 36'' deep x 41'' high - exclusive of casters. 620 lbs. 750 lbs.