Contact person RISE Date Reference Page Daniel Månsson P (13) Energy and circular economy

Similar documents
Contact person RISE Date Reference Page Björn Folkeson P (13) Energy and circular economy

Contact person Date Reference Page Daniel Månsson P (13) Energy and circular economy

Contact person RISE Date Reference Page. Daniel Månsson P (13) Energy and circular economy

Contact person RISE Date Reference Page Björn Folkeson P03675B 1 (11) Energy and circular economy

Contact person Date Reference Page Daniel Månsson P07886B-rev2 1 (14) Energy and bioeconomy

Contact person Date Reference Page Björn Folkeson P (15) Energy and bioeconomy

Contact person Date Reference Page Björn Folkeson P (14) Energy and bioeconomy

Contact person Date Reference Page Daniel Månsson P07886C-rev2 1 (14) Energy and bioeconomy

Contact person Date Reference Page Daniel Månsson P07886E-rev2 1 (14) Energy and bioeconomy

Meibes Heat Interface Unit (HIU) A2RXE Instantaneous Hot Water & Space Heating

Building Engineering Services Association Technical Standard for: UK HIU TEST REGIME UK/HIU. October 2018

SATK wall-mounted Heat Interface Unit (HIU) Instantaneous domestic hot water production

Technote. Frese AquaHeat HW - DH. Application. Design. Features and Benefit. Operation. Optional.

Operating Guide. Termix Solar A+/B+ 1.0 Table of Contents. 1.0 Table of Contents

UNIQ HEAT BATTERIES REFERENCE MANUAL_V2.2. Version: 2018_07_19_v2.2

SUPERIOR QUALITY HEAT INTERFACE UNITS PUTTING YOU IN CONTROL. Pegler Yorkshire

Herz York Direct Heat Interface Unit

INDIVIDUAL APARTMENT SUBSTATION TESTING DEVELOPMENT OF A TEST AND INITIAL RESULTS

heat interface units A BOILER WITHOUT A FLAME

SATK 30 heat interface unit

Metering systems 0548EN April 2014

heat interface units A BOILER WITHOUT A FLAME HIU Single PHE options

T. +44 (0) E.

ModuSat TP. Energy. Heat Interface Units

ModuSat TP. Energy. Heat Interface Units

Heat Interface Units for decentralised water heating in district heating systems

Operating Guide. Termix Compact 28 VX-FI / HWP / HWS. 1.0 Table of Contents. 1.0 Table of Contents

Cylinders for Domestic Purposes Heat Pumps

Installation and Operation Instructions Domestic hot water module FriwaMini with circulation - DN 15

Contact person Date Reference Page Henrik Andersson F (4) Electronics

EcoAdvance Dual Plate

SATK50-60 series CONTENTS. Recess Mounted Heat Interface Unit - SATK series INSTRUCTIONS FOR INSTALLATION, COMMISSIONING AND MAINTENANCE

AVTI Multifunctional self - acting controller

INSTALLATION AND SERVICING

Installation, service and operating instruction Cetetherm Mini Plus CM737 DHWC

80HMA. Comfort Module Range for Monobloc Heat Pumps. Compact comfort module. DHW management possibility. Multi zone option control.

TA-COMFORT-S. Prefabricated units Heating interface unit for surface heating and hot water services

BESA HIU test procedure. Martin Crane. Carbon Alternatives

80HMA. Comfort Module Range for Monobloc Heat Pumps. Nominal heating capacity 4-20 kw Nominal cooling capacity 4-20 kw. Features

This manual must be kept with the appliance

EasiHeat Mechanical Installation and Commissioning Instructions

Wall-mounted compact indirect heat interface unit SATK30 series Safety instructions Dimensions Technical specifications Installation Commissioning

Components for solar heating systems

Installation, Operation and Maintenance Instructions Thermaflow E Plate Heat Exchanger Package OM013

Installation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump

SEALED THERMAL STORE

Geolo THE GROUND SOURCE HEAT PUMP PLUSES

System Design for efficiency using electronic, intelligent HIU s. Neil Parry CIBSE Accredited Heat Network Consultant

SOTTOSTAZIONI PER TELERISCALDAMENTO DISTRICT HEATING SUBSTATIONS

CALEFFI. SATK wall-mounted heat interface unit Fitted for connection to DHW storage. SATK40 series 01216/14 GB

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)

Akva Lux VX District heating substation for indirect heating and domestic hot water systems

Solar heating systems

EU-TYPE EXAMINATION CERTIFICATE

ECONOFLAME R6000 GAS FIRED CONDENSING HOT WATER HEATER SUPPLEMENT

Design & Product Guide. Danfoss FlatStations.

ThermoDual Domestic hot water charging system

Wall-mounted substation PKL-113

TABLE OF CONTENTS TECHNICAL DOCUMENTATION 03. Technical Data Electrical Details Connection Details Dimensions Standing Losses

Screw Water Cooled Chiller SCW210

Broag Pressurisation equipment

Akva Vita TDP-F District heating flat station for direct heating and domestic hot water systems

UK-specific appendix to Installation instructions DHP-A DHP-A Opti DHP-AQ Maxi DHP-H DHP-H Opti DHP-H Opti Pro DHP-L DHP-L Opti DHP-L Opti Pro

New TERMOVAR Loading Unit. The link between bio-energy boiler and storage tank system

Installation and Servicing Instructions. Alpha FlowSmart

Stokvis R600 LMS IP Water Heater Gas-Fired Floor Standing Condensing

HyBo - Hydraulic Interface Unit AMBIENT HEATING AND DOMESTIC HOT WATER PRODUCTION FOR CENTRAL HEATING SYSTEM UNIT CODE EHIU1

Technical paper Selection of district heating house stations

QAW70. Room Unit. Siemens Building Technologies HVAC Products. for use with heating controllers

Balancing & Control. Frese PV Compact. Differential Pressure Control Valve

Technical data. Danfoss DHP-A

HW 22 District heating substation for indirect heating and domestic hot water systems

LK Heat Exchanger Pack 10 -n

Extreme Domestic Hot Water Loading System TECHNICAL DOCUMENTATION. Issue 11/09

CALEFFI. Solar storage-to-boiler thermostatic connection kit series 01164/09 GB. Function

Akva Vita TDP District heating flat station for direct heating and domestic hot water systems

WRAS TEST & ACCEPTANCE CRITERIA Issue No: 1 Date of issue: October Sheet 1 of 7

Stored Water District Heating Interface Units. Heat Interface Units

Empty unit Cover Water Total weight 15 kg 8 kg 10 kg 33 kg

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)

RVL471 Heating and Domestic Hot Water Controller Basic Documentation

Halton Rex for Vario R6O - Variable air volume chilled beam

Air Cooled Scroll Chiller / Heat Pump

Fusion 200, 300 & 500

HIGH POWER. VICTRIX PRO 2 ErP. High power, wall-hung condensation boiler

Akva Lux TDP-F District heating flat station for direct heating and domestic hot water systems

Installation Guide. Termix Distribution unit. 1.0 Table of Contents. 1.0 Table of Contents

MODEL: DV72 R & L. Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual

Ultrasonic Clamp-On Flow Meter Testing

1 DOCUMENT REVISION CONTROL ELEMENTS... 9

Cast Iron Boilers. G Series ( kW)

THE REMEHA HIU RANGE Installation, operation and maintenance manual December 2017

Test Report No.: Page 2 of 14

QAW70. Room Unit. Building Technologies. for use with heating controllers

The New Caroma TMV20

Systems for central heating

Boiler controller S-Tronic Plus

Wood Boiler Plumbing Schematics

TOSHIBA AIR CONDITIONING

Transcription:

Contact person RISE Daniel Månsson 2018-08-07 8P04823 1 (13) Energy and circular economy +46 10 516 53 28 daniel.mansson@ri.se Flamco LTD Washway Lane, St. Helens Merseyside WA10 6PB Great Britain Testing of a HIU according to the UK HIU Test Regime (3 appendices) 1 Assignment RISE has tested a heat interface unit (HIU) (also known as a district heating substation) from HSF on behalf of Flamco. 2 Test method The test method is described in the UK HIU Test Regime Technical Specification, Rev-007, issued by the Building Engineering Services Association (BESA). This will be referred to as the Test Regime throughout this document. The Test Regime specifies testing according to two different test packages: High temperature, with a primary supply temperature of 70 C, and Low temperature, with a primary supply temperature of 60 C. The current test object was tested according to both the High and Low temperature test package. 3 Test object Manufacturer: HSF Model name: Meibes A2RXE Type/serial number: AI-10920.40OH30 Year of manufacture: 2018 Domestic hot water priority: yes 3.1 Design pressures Primary side: 16 bar Secondary side, space heating: 3 bar Secondary side, DHW: 10 bar Maximum differential pressure, primary side: 2.5 bar 3.2 Design temperatures Primary side: max 90 C Secondary side, space heating: dimensioned for 30-80 C Secondary side, DHW: dimensioned for 45-60 C Postal address Office location Phone / Fax / E-mail This document may not be reproduced other than in full, except with the Box 857 SE-501 15 BORÅS Sweden Brinellgatan 4 SE-504 62 BORÅS +46 10 516 50 00 +46 33 13 55 02 info@ri.se prior written approval of RISE.

2018-08-07 8P04823 2 (13) Figure 1. The test object after testing. Insulation removed. 3.3 Components and documentation See Appendix 1.

2018-08-07 8P04823 3 (13) 4 Test location and time The testing was performed at RISE in Borås, Sweden, section of Energy and circular economy, June 2018. The test object arrived to RISE on the 11 th of June with no visible damage. 5 Abbreviations Term Meaning (diagram legend entry) DHW Domestic hot water - HIU Heat Interface Unit - SH Space heating - P₁ Heat load, primary side [kw] P₂ Heat load, space heating side [kw] P₃ Heat load, domestic hot water [kw] t₁₁ Temperature, primary supply connection (DH supply) [ o C] t₁₂ Temperature, primary return connection (DH return) [ o C] t₂₁ Temperature, space heating return connection (SH return) [ o C] t₂₂ Temperature, space heating supply connection (SH supply) [ o C] t₃₁ Temperature, cold water (CWS) [ o C] t₃₂ Temperature, domestic hot water supply connection (DHW supply) [ o C] q₁ Volume flow, primary side (DH) [l/s] q₂ Volume flow, space heating side (SH) [l/s] q₃ Volume flow, domestic hot water (DHW) [l/s] p 1 Pressure drop, primary side across HIU [bar] p 2 Pressure drop, space heating side across HIU [kpa] p 3 Pressure drop, domestic hot water across HIU [kpa] 6 Test equipment The following equipment has been used during the tests: District heating test rig FV3 ETu-QD CB:11 Differential pressure meter Inv. no. 202 111 Differential pressure meter Inv. no. 202 112 Differential pressure meter Inv. no. 202 680 Flow meter, inductive, DN 15 Inv. no. 202 082 Flow meter, inductive, DN 15 Inv. no. 202 687 Flow meter, inductive, DN 15 Inv. no. 202 686 Flow meter, inductive, DN 4 Inv. no. BX60131 Logger for measured data Inv. no. 202 879 Pressure meter for pressure test Inv. no. 201 378

2018-08-07 8P04823 4 (13) Figure 2. Simplified schematic of the test rig used for the tests.

2018-08-07 8P04823 5 (13) 6.1 Collection of measurement data, static measurements When conditions were stable, measurement results were registered for at least 300 seconds. Registered static measurement test values are averages of 300 data points. Sampling rate was 1 Hz for static tests. The pressure in the space heating circuit was 1.5 bar. 6.2 Collection of measurement data, dynamic measurements Sampling rate was 1 Hz for dynamic measurements. The time constant for the temperature sensors in the measuring point t₃₂ is 1.5 s and represents 63% of the final value of a momentary change of temperature from 10 to 90 C. The time constant for the flow meter to measure the DHW flow is 0.2 s. The pressure for the incoming cold water was 1.5 bar for the production of DHW on demand via a heat exchanger. For the control of DHW flow the test rig has two parallel coupled solenoid valves. Each solenoid valve controls a set flow. Results are presented in chart form and are verified with numerical values. 6.3 Control systems for DHW The tested HIU is intended for direct exchange of DHW. This means that the incoming cold water (10 ± 0.5 ºC), is heated directly in the heat exchanger to DHW temperature. The temperature of DHW in the measuring point t₃₂ was measured in connection to the HIU DHW tap. 6.4 Measurement uncertainty Unless otherwise stated in conjunction with the reported values, the measurement uncertainty has been estimated to be better than following values: Differential pressure, primary ± 10 kpa Differential pressure, space heating ± 1 kpa Differential pressure, domestic hot water ± 1 kpa Temperature 0-100 C ± 0.1 C Flow, space heating (0.03-0.5 l/s) ± 1.5 % Flow, space heating (0.002-0.03 l/s) Specified in conjunction with each reported measurement Flow, primary (0.11-0.5 l/s) ± 1.5 % Flow, primary (< 0.11 l/s) Specified in conjunction with each reported measurement Flow, domestic hot water (0.02-0.4 l/s) ± 1.5 % Pressure 0-7 MPa ± 10 kpa The measurement uncertainty for calculated average values in test point 1a-f and 4a-b is presented in conjunction with the reported value. The measurement uncertainty has been calculated according to EA-4/16 with a coverage factor k=2.

2018-08-07 8P04823 6 (13) 7 Test results The test results apply only to the tested unit. The results of each test are presented as specified in the Test Regime. Refer to Table 1 regarding the test setup and Table 2 for details on the reporting. Table 1. Test setup. Extract from the Test Regime. No Static tests 0a 0b Test Static pressure test (same static pressure on both flow and return connections) Differential pressure test (DH flow at higher pressure than DH return) 1a Space Heating 1 kw (DH 70 C flow) 1b Space Heating 2 kw (DH 70 C flow) 1c Space Heating 4 kw (DH 70 C flow) 1d Space heating 1 kw (DH 60 C flow) 1e Space heating 2 kw (DH 60 C flow) 1f Space heating 4 kw (DH 60 C flow) Dynamic tests 2a 2b 3a 3b 4a 4b 5a 5b DHW only (DH 70 C flow) DHW only (DH 60 C flow) Low flow DHW (DH 70 C flow) Low flow DHW (DH 60 C flow) Keep-warm (DH 70 C flow) Keep-warm (DH 60 C flow) DHW response time (DH 70 C flow) DHW response time (DH 60 C flow) static pressure on return [bar] 1.43 times rated value 1.43 times rated value dp across HIU dp₁ [bar] 1.43 times rated value 1.43 times rated value Primary flow temp t₁₁ [ C] DHW setpoint t₃₂ [ C] DHW flow rate q₃ [l/s] DHW power P₃ [kw] SH output P₂ [kw] SH flow temp t₂₂ [ C] SH return temp t₂₁ [ C] n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a 2.5 0.5 70 55 0 0 1 60 40 2.5 0.5 70 55 0 0 2 60 40 2.5 0.5 70 55 0 0 4 60 40 2.5 0.5 60 50 0 0 1 45 35 2.5 0.5 60 50 0 0 2 45 35 2.5 0.5 60 50 0 0 4 45 35 2.5 0.5 70 55 2.5 0.5 60 50 DHW test profile DHW test profile 2.5 0.5 70 55 0.02 2.5 0.5 60 50 0.02 DHW test profile DHW test profile Record value Record value 0 n/a n/a 0 n/a n/a 0 n/a n/a 0 n/a n/a 2.5 0.5 70 55 0 0 0 n/a n/a 2.5 0.5 60 50 0 0 0 n/a n/a 2.5 0.5 70 55 0.13 2.5 0.5 60 50 0.13 Record value Record value 0 n/a n/a 0 n/a n/a The cold water supply to the HIU on the test rig shall be 10 C and at 1.5 bar for all tests.

2018-08-07 8P04823 7 (13) Table 2. Reporting of test results. Extract from the Test Regime. Test Description Reporting Static tests 0 Pressure tests Pass/Fail as to whether HIU manages pressure test without leaks or damage 1a 1b 1c 1d 1e 1f Space Heating 1 kw, 60/40 C secondary Space Heating 2 kw, 60/40 C secondary Space Heating 4 kw, 60/40 C secondary Space Heating 1 kw, 45/35 C secondary Space Heating 2 kw, 45/35 C secondary Space Heating 4 kw, 45/35 C secondary t12- primary return temperature. Plot of key metrics over duration of test. Note: Outputs readings used as input data to High Temperature Space Heating Weighted Average Return Temperature calculation. t12- primary return temperature. Plot of key metrics over duration of test. Note: Outputs readings used as input data to Low Temperature Space Heating Weighted Average Return Temperature calculation. Dynamic tests 2a 2b 3a 3b 4a DHW only, DH 70 C flow, 55 C DHW DHW only, DH 60 C flow, 50 C DHW Low flow DHW, DH 70 C flow; 55 C DHW Low flow DHW, DH 60 C flow; 50 C DHW Keep-warm. DH 70 C flow; 55 C DHW Pass/Fail on DHW exceeding 65 C (at t32) for more than 10 seconds. Comment on stability of DHW temperature. Assessment of scaling risk, based on extent and duration of temperatures in excess of 55 C. Plot of key metrics over duration of test. Note: Outputs used as input data to High Temperature Domestic Hot Water Volume Weighted Average Return Temperature calculation. Assessment of whether return temperatures remain under control at the lower flow temperature. Assessment of scaling risk, based on extent and duration of temperatures in excess of 55 C. Plot of key metrics over duration of test. Note: Outputs used as input data to Low Temperature Domestic Hot Water Volume Weighted Average Return Temperature calculation. Pass/Fail on DHW exceeding 65 C (at t₃₂) for more than 10 seconds. Pass/Fail on DHW maintaining 55 C±3 C (at t32) for 60 seconds. Assessment of scaling risk, based on extent and duration of temperatures in excess of 55 C Commentary if DHW supply not stable. Plot of key metrics over duration of test. Pass/Fail on DHW maintaining 50 C±3 C (at t32) for 60 seconds. Assessment of scaling risk, based on extent and duration of temperatures in excess of 55 C Commentary if DHW supply not stable. Plot of key metrics over duration of test. Assessment of whether valid keep-warm operation, based on 5a response time criteria: Pass / Fail. Observation on the operation of the HIU during keep-warm. Assessment of scaling risk, based on extent and duration of temperatures in excess of 55 C. Comment on HIU keep-warm controls options. Plot of key metrics over duration of test. If cycling is observed, plot of the key metrics over the duration of a typical keepwarm cycle. State heat loss in Watts. State primary flowrate. Note: Outputs used as input data to High Temperature Keep-warm Volume Weighted Average Return Temperature calculation

2018-08-07 8P04823 8 (13) Test Description 4b Keep-warm, DH 60 C flow; 5a 5b 50 C DHW DHW response time, DH 70 C flow; 55 C DHW DHW response time, DH 60 C flow; 50 C DHW Reporting Assessment of whether valid keep-warm operation, based on 5a response time criteria: Pass / Fail. Observation on the operation of the HIU during keep-warm. Assessment of scaling risk, based on extent and duration of temperatures in excess of 55 C. Comment on HIU keep-warm controls options. Plot of key metrics over duration of test. If cycling is observed, plot of the key metrics over the duration of a typical keepwarm cycle. State heat loss in Watts. State primary flowrate. Note: Outputs used as input data to Low Temperature Keep-warm Volume Weighted Average Return Temperature calculation Pass/Fail on DHW exceeding 65 C (at t32) for more than 10 seconds. State time to achieve 45 C (at t32) and not subsequently drop below 42 C. Comment on stability of DHW temperature. Plot of key metrics over duration of test. State time to achieve 45 C (at t32) and not subsequently drop below 42 C. Comment on stability of DHW temperature. Plot of key metrics over duration of test. 7.1 Test 0: Pressure tests During the static pressure test 0a, the tightness of the components on the primary side of the HIU has been checked. This has been performed by closing the primary return and pressurizing the primary flow to 22.9 bar (1.43 times the construction pressure) for 30 minutes. During this test the pressure in the space heating circuit and the pressure on incoming cold water was 1.5 bar. No leakage or damage was detected during the static pressure test 0a. During the differential pressure test 0b, the tightness of the space heating control valve and the DHW control valve has been checked. This has been performed by pressurizing the primary flow to 3.6 bar (1.43 times the maximum differential pressure) for 30 minutes with the primary return open and the space heating control valve and the DHW control valve closed. During this test the pressure in the space heating circuit and the pressure on incoming cold water was 1.5 bar. No leakage or damage was detected during the differential pressure test 0b. Test requirement: The HIU is to manage the pressure tests without leaks or damage. Result: Pass. 7.2 Test 1a-1f: Space Heating 1-4 kw For test points 1a-1f a space heating load of 1-4 kw was simulated using a heat exchanger on the test rig. The HIU pump was deactivated and the space heating flow was adjusted in the test rig to deliver the required space heating load. The pressure in space heating circuit was 1.5 bar for all tests.

2018-08-07 8P04823 9 (13) While the HIU was delivering 4 kw of space heating, the space heating flow temperature t₂₂ was adjusted on the HIU until it reached 60 ± 0.5 C (for test points 1a-1c) or 45 ± 0.5 C (for test points 1d-1f) as measured by the test rig. The space heating return temperature t₂₁ was 40 C for test points 1a-1c and 35 C for test points 1d-1f. The primary flow temperature t₁₁ was 70 C for test points 1a-1c and 60 C for test points 1d-1f. The pressure in the space heating circuit was set to 1.5 bar. For further details regarding the test setup, see Table 1. During test 1a-1c the setpoint for space heating supply temperature t₂₂ in the HIU software interface was set to 58.5 C with the setting for return temperature limit at 55 C. During test 1d-1f the setpoint for space heating supply temperature t₂₂ in the HIU software interface was set to 45.0 C with the setting for return temperature limit at 55 C. The results of the test points 1a-1f are presented in Table 3 as averages of 300 data points. The measurement uncertainty has been estimated to be better than the values in Table 4. The results are also presented in Figure 3 to Figure 8, appendix 2. Table 3. Test results for test points 1a-1f. Primary Test point Secondary t₁₁ t₁₂ q₁ P₁ t₂₁ t₂₂ q₂ p₂ P₂ [ C] [ C] [l/s] [kw] [ C] [ C] [l/s] [kpa] [kw] 1a 70.0 39.7* 0.010 1.2 40.0 61.2 0.013 0.4 1.1 1b 70.1 40.0 0.016 2.0 40.0 60.3 0.023 0.7 1.9 1c 70.1 40.2 0.033 4.1 39.9 60.3 0.047 1.5 4.0 1d 60.0 34.9* 0.011 1.1 35.1 45.1 0.025 0.5 1.0 1e 60.1 34.9* 0.020 2.1 35.0 45.2 0.047 1.3 2.0 1f 60.0 34.9* 0.041 4.3 34.9 45.4 0.095 3.9 4.1 *) The primary return temperature t12 was measured to be lower than the space heating return temperature t21, which is not practically possible if considering only the heat exchanger. The measurement result was due to heat losses and thereby temperature drop in the piping from the measuring point of t21 at the HIU inlet to the heat exchanger on the secondary side and from the outlet of the heat exchanger to the measuring point of t12 at the HIU primary side outlet. Table 4. Measurement uncertainty for test points 1a-1f. Primary Secondary Test point t₁₁ t₁₂ q₁ P₁ t₂₁ t₂₂ q₂ p₂ P₂ [ C] [ C] [l/s] [kw] [ C] [ C] [l/s] [kpa] [kw] 1a ±0.1 ±0.1 ±0.0005 ±0.1 ±0.1 ±0.1 ±0.0002 ±1 ±0.02 1b ±0.1 ±0.1 ±0.0008 ±0.1 ±0.1 ±0.1 ±0.0003 ±1 ±0.03 1c ±0.1 ±0.1 ±0.0016 ±0.2 ±0.1 ±0.1 ±0.0007 ±1 ±0.06 1d ±0.1 ±0.1 ±0.0005 ±0.1 ±0.1 ±0.1 ±0.0003 ±1 ±0.02 1e ±0.1 ±0.1 ±0.001 ±0.1 ±0.1 ±0.1 ±0.0007 ±1 ±0.04 1f ±0.1 ±0.1 ±0.002 ±0.2 ±0.1 ±0.1 ±0.0013 ±1 ±0.08 7.3 Test 2a: DHW only, DH 70 C flow In test point 2a a dynamic test of DHW was performed according to DHW flow rates specified in the Test Regime. The primary flow temperature t₁₁ was 70 C. The DHW setpoint was adjusted while the HIU delivered 0.13 l/s of DHW until the DHW temperature t₃₂ reached

2018-08-07 8P04823 10 (13) 55 ± 0.5 C as measured by the test rig. The HIU DHW setpoint was 55 C in the HIU software interface. For further details regarding the test setup, see Table 1. The DHW temperature (t₃₂) exceeded 55 C for 241 seconds during the test. The DHW temperature (t₃₂) did not exceed 65 C during the test. The highest measured temperature in point t₃₂ was 57.8 C. Between 200 and 2160 seconds, the lowest measured temperature in point t₃₂ was 51.0 C. Test requirement: The DHW flow temperature t₃₂ is not to exceed 65 C for more than 10 seconds. Result: Pass. The test results for test point 2a are presented in Figure 9, appendix 2. 7.4 Test 2b: DHW only, DH 60 C flow In test point 2b a dynamic test of DHW was performed according to DHW flow rates specified in the Test Regime. The primary flow temperature t₁₁ was 60 C. The DHW setpoint was adjusted while the HIU delivered 0.13 l/s of DHW until the DHW temperature t₃₂ reached 50 ± 0.5 C as measured by the test rig. The HIU DHW setpoint was 50 C in the HIU software interface.. For further details regarding the test setup, see Table 1. The DHW temperature (t 32) did not exceed 55 C during the test. The highest measured temperature in point t₃₂ was 53.0 C. Between 200 and 2160 seconds, the lowest measured temperature in point t₃₂ was 47.5 C. The test results for test point 2b are presented in Figure 10, appendix 2. 7.5 Test 3a: Low flow DHW, DH 70 C flow In test point 3a a low DHW flow of 0.02 l/s was tested. The primary flow temperature t₁₁ was 70 C and the domestic hot water setpoint was the same as in test point 2a. For further details regarding the test setup, see Table 1. The DHW temperature (t₃₂) exceeded 55 C for 300 seconds during the test. The DHW temperature (t₃₂) did not exceed 65 C during the test. For a 60 second period, the primary flow q₁ varied between 55 and 57 l/h while t₃₂ varied between 55.1 and 55.2 C. Test requirement: The DHW flow temperature t₃₂ is not to exceed 65 C for more than 10 seconds. Result: Pass Test requirement: The DHW flow temperature t₃₂ is to be maintained within 55 ± 3 C for 60 seconds. Result: Pass The results of the test point 3a are presented in Figure 11, appendix 2.

2018-08-07 8P04823 11 (13) 7.6 Test 3b: Low flow DHW, DH 60 C flow In test point 3b a low DHW flow of 0.02 l/s was tested. The primary flow temperature t₁₁ was 60 C and the domestic hot water setpoint was the same as in test point 2b. For further details regarding the test setup, see Table 1. The DHW temperature (t 32) did not exceed 55 C during the test. For a 60 second period, the primary flow q₁ varied between 58 and 60 l/h while t₃₂ was stable at 49.7 C. Test requirement: The DHW flow temperature t₃₂ is to be maintained within 50 ± 3 C for 60 seconds. Result: Pass The results of the test point 3b are presented in Figure 12, appendix 2. 7.7 Test 4a: Keep-warm, DH 70 C flow In test point 4a the standby characteristics of the HIU were tested. A DHW flow of 0.13 l/s was drawn until stable conditions were reached and was then turned off. Data was then collected for 8 hours. For further details regarding the test setup, see Table 1. The standby performance of the HIU is dependent on the standby control method used. In the HIU software interface the Keep-warm Temperature was set to 41 C, Keep-warm Time was set to Comfort - always, Warmup Boost was set to 20 l/min and the Legionella Prevention Program was switched off. If the difference between the maximum and minimum primary flow temperature t₁₁ is higher than 6 C during the final 3 hours of the test the HIU is considered to perform keep-warm cycling. The temperature difference between the maximum and minimum primary flow temperature t₁₁ was 2.8 C during the final 3 hours of the test and as such the HIU was not considered to perform keep-warm through cycling. The validity of the keep-warm facility is evaluated in test point 5a. During the 8 hours after turning off the domestic hot water flow the average primary flow q₁ was 6.1 l/h with measurement uncertainty { +2.3 l/h, and the average heat load P₁ was 59 W 2.1 with measurement uncertainty { +28 23 W. The DHW temperature (t 32) did not exceed 55 C during the test. The results of the test point 4a are presented in Figure 13, appendix 2. 7.8 Test 4b: Keep-warm, DH 60 C flow In test point 4b the standby characteristics of the HIU were tested. A DHW flow of 0.13 l/s was drawn until stable conditions were reached and was then turned off. Data was then collected for 8 hours. For further details regarding the test setup, see Table 1.

2018-08-07 8P04823 12 (13) The standby performance of the HIU is dependent on the standby control method used. In the HIU software interface the Keep-warm Temperature was set to 41 C, Keep-warm Time was set to Comfort - always, Warmup Boost was set to 20 l/min and the Legionella Prevention Program was switched off. If the difference between the maximum and minimum primary flow temperature t₁₁ is higher than 6 C during the final 3 hours of the test the HIU is considered to perform keep-warm cycling. The temperature difference between the maximum and minimum primary flow temperature t₁₁ was 2.2 C during the final 3 hours of the test and as such the HIU was not considered to perform keep-warm through cycling. The validity of the keep-warm facility is evaluated in test point 5b. During the 8 hours after turning off the domestic hot water flow the average primary flow q₁ was 7.4 l/h with measurement uncertainty { +2.6 l/h, and the average heat load P₁ was 53 W 2.5 with measurement uncertainty { +24 21 W. The DHW temperature (t 32) did not exceed 55 C during the test. The results of the test point 4b are presented in Figure 14, appendix 2. 7.9 Test 5a: DHW response time, DH 70 C flow Immediately after test point 4a, test point 5b was carried out. A DHW flow of 0.13 l/s was drawn until conditions were stable. For further details regarding the test setup, see Table 1. The DHW response time might be dependent on the HIU keep-warm settings. See Test 4a: Keep-warm, DH 70 C flow. The DHW temperature (t₃₂) did not exceed 65 C during the test. The DHW temperature (t₃₂) reached 45 C 11 seconds after the DHW flow was started and did not drop below 42 C thereafter. Test requirement: The DHW flow temperature t₃₂ is not to exceed 65 C for more than 10 seconds. Result: Pass. Test requirement: the keep-warm facility is considered valid if the DHW temperature t₃₂ reaches 45 C within 15 seconds. Result: Pass. The results of the test point 5a are presented in Figure 15, appendix 2. 7.10 Test 5b: DHW response time, DH 60 C flow Immediately after test point 4b, test point 5b was carried out. A DHW flow of 0.13 l/s was drawn until conditions were stable. For further details regarding the test setup, see Table 1.

2018-08-07 8P04823 13 (13) The DHW response time might be dependent on the HIU keep-warm settings. See Test 4b: Keep-warm, DH 60 C flow. The DHW temperature (t₃₂) reached 45 C 12 seconds after the DHW flow was started and did not drop below 42 C thereafter. Test requirement: the keep-warm facility is considered valid if the DHW temperature t₃₂ reaches 45 C within 15 seconds. Result: Pass. The results of the test point 5b are presented in Figure 16, appendix 2. Energy and circular economy - Sustainable Supply Systems and Plastic Products Performed by Examined by Signature_2 Daniel Månsson Thomas Ljung Appendices 1. Component data and documentation 2. Diagrams

2018-08-07 8P04823 1 (2) Appendix 1 Appendix 1. Component data and documentation Component Space heating heat exchanger Domestic hot water heat exchanger Controller for space heating and domestic hot water Control valve and actuator for space heating Documentation submitted Manufacturer and type SWEP E8LASH/1P-SC-S 4x3/4" SWEP E8LASH/1P-SC-S 4x3/4" HSF control box, software version 1.32.J Mut Meccanica VDE/ML 24V diam 9.5 180 Space heating strainer HSF Y filter DN20 G3/4 0.5 mm Control valve and actuator for domestic hot water Temperature sensors Domestic hot water isolating valve/check valve Mut Meccanica VDE/ML 24V diam 9.5 180 Space heating: Grundfos RPSx6, Primary supply, primary return and domestic hot water: Tasseron TS40AD-R Neoperl OV20/DN20 Primary side strainer HSF Y filter DN20 G3/4 0.5 mm Drain valves Simplex KFE DN10 Vent valves Flamco Flexvent G3/8 27725 Circulation pump Grundfos UPM3 Auto 15-70 130 ZZZ Heat meter Joints and connections HSF (brass) Rossweiner Heatsonic 1.5 m3/h 128 202 2 G3/4 DN15 Gaskets James Walker Sentinel Pipes HSF 18x1 Copper NEN-EN 1057 Differential pressure control valve (not fitted on test object) Expansion vessel Safety valve, space heating Shock absorber (incoming cold water) Flow sensor for domestic hot water Manometer and thermometer (not fitted on test object) No Frese PV Compact DN20 20 60 kpa kvs 4.7 Varem Flatvarem Rettangolari C6008931 8 litres Flamco Prescor ½ 3 bar Caleffi Water hammer arrester 525150 ¾ Sika turbine flow sensor VTY10 N/A

2018-08-07 8P04823 2 (2) Appendix 1 Documentation Schematic diagram and drawing showing the structure and arrangement of the HIU with dimensions and weight Technical specification for electronic components including version of software Details of calculation programs used for the heat exchangers Installation guide Commissioning guide Operation guide with a function description/description of operations and care instructions as suited to the intended user category Declaration of Conformity for CE-marked HIU:s Full parameter list for electronically controlled HIU:s HIU marking Model name and type number Documentation submitted Information present on HIU marking Comment Installation & user manual - EcoAdvance Dual Plate Heat Interface Unit (Rev. A - 26-04-2016) Software version 1.32.J SWEP SSPG7 7.0.3.69 Integrated in installation & user manual Integrated in installation & user manual Integrated in installation & user manual EMC, LVD. Integrated in installation & user manual Comment Meibes A2RXE TP 21L 10Kw BPHM(53270) Serial number AI-10920.40OH30

2018-08-07 8P04823 1 (14) Appendix 2 Appendix 2. Diagrams Figure 3. Results for test point 1a: space heating 1 kw, DH 70 C supply.

2018-08-07 8P04823 2 (14) Appendix 2 Figure 4. Results for test point 1b: space heating 2 kw, DH 70 C supply.

2018-08-07 8P04823 3 (14) Appendix 2 Figure 5. Results for test point 1c: space heating 4 kw, DH 70 C supply.

2018-08-07 8P04823 4 (14) Appendix 2 Figure 6. Results for test point 1d: space heating 1 kw, DH 60 C supply.

2018-08-07 8P04823 5 (14) Appendix 2 Figure 7. Results for test point 1e: space heating 2 kw, DH 60 C supply.

2018-08-07 8P04823 6 (14) Appendix 2 Figure 8. Results for test point 1f: space heating 4 kw, DH 60 C supply.

2018-08-07 8P04823 7 (14) Appendix 2 Figure 9. Results for test point 2a: DHW only, DH 70 C supply.

2018-08-07 8P04823 8 (14) Appendix 2 Figure 10. Results for test point 2b: DHW only, DH 60 C supply.

2018-08-07 8P04823 9 (14) Appendix 2 Figure 11. Results for test point 3a: Low flow DHW, DH 70 C supply.

2018-08-07 8P04823 10 (14) Appendix 2 Figure 12. Results for test point 3b: Low flow DHW, DH 60 C supply.

2018-08-07 8P04823 11 (14) Appendix 2 Figure 13. Results for test point 4a: Keep-warm, DH 70 C supply

2018-08-07 8P04823 12 (14) Appendix 2 Figure 14. Results for test point 4b: Keep-warm, DH 60 C supply.

2018-08-07 8P04823 13 (14) Appendix 2 Figure 15. Results for test point 5a: DHW response time, DH 70 C supply.

2018-08-07 8P04823 14 (14) Appendix 2 Figure 16. Results for test point 5b: DHW response time, DH 60 C supply.