PG 990 Atomic Absorption

Similar documents
LABTRON LAAS - Series Atomic Absorption Spectrophotometer

NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation.

ATOMIC ABSORPTION SPECTROMETER AAS 3500 EPC / PRODUCTS / APPLICATION / SOFTWARE / ACCESSORIES / CONSUMABLES / SERVICES

Affordable Lab Technology

AAnalyst 700 Atomic Absorption Spectrometer

SP-3800AA Atomic Absorption Spectrophotometer

Atomic Absorption Spectrophotometer AAS 2320D EPC / PRODUCTS / APPLICATION / SOFTWARE / ACCESSORIES / CONSUMABLES / SERVICES

ice 3000 Series Atomic Absorption Spectrometers Flame and furnace AAS analysis for routine laboratories

ice 3000 Series Atomic Absorption Spectrometers Flame and furnace analysis for routine laboratories

Atomic Absorption Spectrometer

INDIAN INSTITUTE OF SCIENCE EDUCATION AND RESEARCH PUNE

AAnalyst 600/800 atomic absorption spectrometers

ice 3000 Series Atomic Absorption Spectrometers

Atomic Absorption Spectrophotometers. AA Series C122-E058E

C122-E058C. AA-7000 Series. Shimadzu Atomic Absorption Spectrophotometers

Mercury Vapor Monitor VM-3000

VM-3000 Mercury Vapor Monitor

VM-3000 Mercury Vapor Monitor

t. +44 (0) f. +44 (0) e. w.

detectors UltiMate 3000 Variable Wavelength Detectors

高等食品分析 (Advanced Food Analysis) II. INSTRUMENTS FOR OPTICAL SPECTROSCOPY *Instruments for optical spectroscopy: Optical spectroscopic methods are

M&S Series Atomic Absorption Systems

BENEFITS. QUATERNARY HPLC SYSTEMS Quaternary and Other Gradients. The Complete Range of HPLC. Convenience of Maintenance. Systems Configuration

CS744 Series: Carbon/Sulfur by Combustion

Soil and Plant Methods List for Automated Ion Analyzers. Flow Injection Analysis

Nexera-i Specifications Prominence-i Specifications

Chemistry Instrumental Analysis Lecture 4. Chem 4631

SAMPLE SPECIFICATIONS CONTINUOUS MONITORING SYSTEM (Insitu)

Customers should provide all necessary operating supplies upon request of the engineer.

NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation.

An FT-NIR Primer. NR800-A-006

In-line Oil in Water Analyser - Model OIW-EX100P and OIW-EX1000P

RIELLO 40 GS/M SERIES

Who is GBC Scientific Equipment?

2100 Series Laboratory Turbidimeters. Pioneering technology in turbidity monitoring.

Technical specifications of FT-IR Spectrometer

Series 9000 Total Hydrocarbon Analyzer

Thermo Scientific Dionex UltiMate 3000 Fluorescence Detectors

White paper on the Dielectric Barrier Discharge Detectors. Introduction:

APPLIED. OMA-406R Rackmount Process Analyzer

Common Features of DX-600 Modules

APPLIED. OMA-206P Portable Process Analyzer. A window into your process since 1994.

OMA-300 Process Analyzer

A Platform for the Future ULTIMA 2 ICP OPTICAL E MISSION S PECTROMETER

Laser Analyzers for NH3 Safety Monitoring and Leak Detection

HFID Heated Total Hydrocarbon Analyzer Module

OPERATION MANUAL RK-2006LPP AUGER FITTED SOLID FUEL BOILER TEMPERATURE CONTROLLER. Version DC19

Eclipse Self-Check UV Scanner

Specifications Wavelength Range: 190 nm to 800 nm continuous

Eclipse 90 UV Scanner Model A Version 1

NanoReady. Micro UV-Vis Spectrophotometer

APPLIED. OMA-300 Hydrogen Sulfide Analyzer H 2. Ex p. Ex d. The world s safest continuous H 2. S analyzer. The OMA continuously measures H 2

Introduction to the Fusion TOC Analyzer

UV Scanner. Model Specification. Introduction. 854 Instruction Manual

USER MANUAL MINITRACER PORTABLE SNIFFER

The New Digital BWB Flame Photometer Range

TIMS TIMS. Thermal Ionisation Mass Spectrometry.

Variable Temperature Options for Optical Experiments

Nicolet Evolution 300. UV-Visible Spectrophotometer

Advanced Monitoring and Characterisation of Combustion Flames

Datalogging as standard

On-line Side Stream Oil in Water Analyser - Model OIW-EX 100 or OIW-EX 1000

Key Features. General Description

HYDROCARBONENGINEERING June June 2015

CCD and CID solid-state detectors

Customised HPLC Systems for Highest Performance

Features and Benefits

Power Flame Incorporated

RL/1 SERIES. One Stage Light Oil Burners FIRING RATES LIGHT OIL RL 34/1 MZ kw

Flame Monitor for Multiple Burner Furnaces D-LE 603 D-UG 660

intrinsically safe detector for hydrocarbon gases

ANNEX I. Technical specifications for: Supply of various Trace Explosive Detection Systems

REFRESH, UPGRADE, PERFORM. Revamping Kits and Digital Solutions for quality improvement and energy savings

FPD - Flame Photometric Detector

ELD500 PRECISION LEAK DETECTOR

Jetstream Series HPLC - PELTIER COLUMN-THERMOSTATS 1. GENERALITIES

µm All temperatures See surfaces through hot flue gas at 3.9 µm and better image quality than VIS 8 14 µm Best at low temperatures

Gas Chromatograph. Features. Continuous Analysis of Ultra High Purity Argon to ppb levels.

Equipment specifications (D6)

MicroRay IR-100 NEW. Inspection MicroRay IR-100

Features and Benefits

ENVAIR lab CO2 Tri-Gas Incubator

SPECTRAL INSTRUMENTATION

Variable Temperature Microprobe Systems

Rapid. Suspended Warm Air Heater. Caring for the environment!

The incredible power of light Photonics-based solutions from ultraviolet to infrared

Gencoa Limited, Physics Road, Liverpool, UK 2. Gencoa USA, Davis, CA, USA 3. Nano4Energy, Madrid, Spain 4. Universidad Autonoma de Madrid, Spain

To request a quote or locate your nearest dealer, contact Customer Care toll-free in the US at or

Absorbance range Resolution Accuracy Type of microplate Wavelength Optic system Light source Wavelength accuracy. Calculation method

Model gffoz Process Ozone Sensor (In-Line)

CALIBRATION HOW IT WORKS

Operations Manual GMA 313 CO 2. Gas Monitor for one detection point

UV Weather Resistance Test Chamber Technical Data

Agilent 1100 Series Variable Wavelength Detector. Reference Manual

The new generation of Multi-Gas measurement. Dipl.- Ing (FH) Andreas Hester, SIGAS Corp. Environment protection Personal safety Process control

portable gas analyser

RS Pro Infrared Temperature Sensor

UniGas Portable, Flue Gas Analysis Advanced Combustion Flue Gas Analyser

MultiGAS Monitoring System Hot/Wet IR Analyzer Technology. Clean Air Systems

Development and demonstration of a diode laser sensor for a scramjet combustor

Transcription:

PG 990 Atomic Absorption Features Fully Automated Spectrophotometer The flame and graphite furnace is integrated into one instrument. The change over from one technique to another is carried out by simple keystrokes within the software. The instruments have a motorised 8 hollow cathode lamp turret which allows the automatic positioning and optimisation of each hollow cathode lamp by the software. The control of the gas flows for the fuel gas (C 2 H 2 ) and the positioning of the burner is also carried out directly from the software thus allowing optimisation of the instruments for the best analytical parameters for a selected analysis. Two methods of background correction are available. The first utilises a deuterium lamp and the second is the proven method of self reversal. The location of the wavelength and peak selection is automatic and controlled from the software. The spectral bandwidth is automated and is available with a choice of five slit sizes. 990 Atomic Absorption Spectrophotometer

1/2 The electronic parameters for the photomultiplier detector, the hollow cathode lamp current and the balancing of the absorbance and background energies are controlled from the software. The ignition of the flame is computer controlled and the various safety interlocks offer a very safe operating system. ADVANCED GRAPHITE FURNACE The unique design of the graphite furnace reduces the chemical interference effects and memory effects by uniformly heating the graphite electrode. The computer controlled heating program allows the user to select the best heating program for the analysis. The optical temperature during the atomisation stage ensures the rapid heating and rapid analysis. This helps to extend the life of the graphite tube and enhances analytical accuracy.

PROVEN SAFETY FEATURES The flame conditions are continuously monitored and should the flow rates change an audible alarm sounds. The pressure of the support gas (oxidant) is monitored constantly. If the pressure changes then the flow of the fuel gas will be stopped and the flame will be safely extinguished. A sensor monitors the level of liquid in the drain and will prevent ignition if too low. The flame will also be extinguished of the level of liquid in the drain changes significantly. The argon pressure for the graphite furnace is constantly monitored and should it change the heating cycle for the graphite electrode will immediately cease and the graphite electrode will be de-energised. Cooling water flow rates for the graphite furnace are also monitored for changes and should changes occur the heating program will cease. If the graphite tube should facture during the heating program the heating will cease. Elements that can be analysed with the PG990 990 Atomic Absorption Spectrophotometer

3/4 INNOVATIVE DESIGN OF PGI 990 The user friendly software requires a Windows platform and operates within Win95, Win98, Win NT, Win 2000 and WinXP. The system uses a number of software wizards to guide the operator through setting up procedures. The software controls the automatic switch over for the Hollow Cathode Lamps and automatically optimises working parameters for the system. The software also allows manual input of data to ensure that the operator always stays in control. The software will automatically complete the configuration of the system for analysis. The user has the choice of two methods of background correction namely the self reversal system OR the traditional deuterium lamp background correction system. During the analysis cycle of both the flame and graphite furnace the software shows the entire measurement process. This includes measured values, temperature steps, time etc. all signal and temperature data is stored for future re-call and printout. Detailed reporting and QC control software is included within AAWin allows printout of spectra, standard calibration curves, analysis and signal data. Full printout of operating parameters is also available for user references. The following methods of analysis can be carried out using the PGI 990 system Absorption, emission, graphite furnace analysis, hydride and cold vapour analysis.

Specifications Optic System Wavelength Range: Monochromator: Spectral Bandwidth: Wavelength Accuracy: Wavelength Repeatability: Baseline Stability: 190nm - 900nm Czerny-Turner configuration 0.1nm, 0.2nm, 0.4nm, 1.0nm, 2.0nm (5 steps. with automatic changeover) 0.25nm 0.15nm 0.005A/30 min Flame analysis Sensitivity (Cu): Burner Head: Nebulizer: Atomization Chamber: Position Adjustment: Safety: 0.03 µg/ml/1% Titanium alloy burner High-efficiency glass nebulizer Corrosion-resistant material Automatic changeover of flame and furnace Automatic setting of optimum height for flame burner Automatic ignition and of mixing air-acetylene gas with safety control Graphite furnace analysis Character Value (Cd): 0.5Pg Temperature Range: Ambient - 2650 Heating: Voltage feedback control when drying and ashing; Optical temperature control when atomizing Heating program: Up to 9 steps with choices of ramp, temperature increase and full-power heating Background correction Deuterium Lamp Background 1.0 Abs Self-Reversal Background Correction: 3.0 Abs Correction: Data processing Analytical method: flame, graphite furnace and hydride Determination method: calibration curves using 1 st, 2 nd and 3 rd order of fit, standard addition method Repetitions: 1-20 with calculations of average, SD and RSD Result Printout: output of parameters, data, spectra and calibration curves Mainframe Light Source: Power Supply: Dimensions 8 hollow cathode lamp turrets with 2 lamps simultaneously lit ( one lamp pre-heated ) 110V/60Hz or 220V/50Hz three-phase AC 200W (mainframe) 5000W (graphite furnace) mainframe 110 cm x 50cm x 45cm graphite furnace 50cm x 50cm x 45cm Note: Typical response: 2 g/ml Cu gives about 0.38Abs. 990 Atomic Absorption Spectrophotometer

5/6 Accessories HYDRIDE AND COLD VAPOUR ANALYSIS A hydride generator is available for the determination of elements such as Arsenic, Selenium, Antimony, Tellurium and mercury at ultra low levels. The hydride generator is supplied with an absorption cell, and electrical absorption cell heater and controller and all necessary burner fittings. AAS FLAME AUTOSAMPLER Sequential auto-sampler allows the automated analysis of 50 or more samples and calibration standards. The system allows for automatic update of standard values and curve parameters by using up to 8 standards, blanks and QC standards. A double wash station with facility for use of sample blank or pure water for probe wash avoids sample and standard contamination. An inert Teflon probe is supplied. GRAPHITE FURNACE AUTOSAMPLER The graphite furnace auto-sampler system allows automatic update of calibration data, matrix modifications and automatic dilution of samples.