Platelet bags constant shaking for long periods of time.

Similar documents
DOUBLE DOOR FREEZER.

Platelet Storage. i.series Horizon Series

Platelet Storage. i.series Horizon Series

Plasma Freezer with air circulation TC 516 acc. to DIN 58375

Freezers. Laboratory & Plasma. i.series Horizon Series. Distinctly. Innovation can be beautiful.

REFRIGERATOR M E D I C A L.

Laboratory refrigerators and freezers

Deep Freezers. Freezers. Biomedical Refrigeration I FR / MF

DEEP FREEZERS AND PLASMA STORAGE FREEZERS. Biomedical Refrigeration I FR / MF TECHNOLOGY FOR LIFE

Freezers. Laboratory & Plasma. i.series Horizon Series

Freezers. Upright Laboratory & Plasma. i.series Horizon Series

PR / MP I Laboratory / Medicine

Refrigerators. Upright Blood Bank. i.series Horizon Series

ULTRA.GUARD ultra low temperature freezer

Industrial Freezer Sales A division of IDS 5311 Derry Avenue Building D Agoura Hills CA Phone (818) Fax (818)

Incubators THE BENCHTOP EQUIPMENT HYGIENE SOLUTION

STABILITY. Stability Storage Chambers & Environmental Stability Rooms

Blood bank refrigerators and freezers. BBR & Mini - Platinum & Iridium - Plasmafrost Series

BATHS SHAKERS STIRRERS HOTPLATES INCUBATORS HEATING MANTLES INCUBATORS

STABILITY ICH. ICH Stability Tests

Incubators. with BioCote antimicrobial protection

Multi-Lab REFRIGERATORS Frigidere medicale

BLOOD BANKING AIISHIL" BLOOD BANK FREEZERS :

Laboratory Deep Freeze Storage Cabinet TC 230 Air circulated

Laboratory Air circulated Refrigerator/Deep Freezer TC Two-door (2 independent temperature ranges)

Medical Air circulated Refrigerator TC (2 independent temperature ranges), also in accordance with DIN 58345

Laboratory Refrigerator/Deep Freezer TC 802

BR range. B Medical Systems BR I +4 C. Blood Bank Refrigerators

Slimline. Laboratory refrigerators and freezers

BATHS; WATER AND OIL, SAND, AND ULTRASONIC Summary table of the different models

Chromatographic Air circulated Refrigerator, two-door TC 603

Ultra low temperature freezers for long-term storage at -86 C UF V 500, UF V 700

FITOCLIMA ECV45 / ECV75 TEMPERATURE & HUMIDITY TEST CHAMBER INTEGRATION WITH ELECTRO-DYNAMIC SHAKER

Digital incubating/ refrigerating benchtop shakers

BLOOD BANK REFRIGERATOR - BR Series

External Dimensions: B = 600 mm D = 630 mm H = 2000 mm. Internal Dimensions: B = 451 mm D = 430 mm H = 1598 mm

Upright Freezers. Laboratory Plasma. TrueBlue. Reliability & Support. i.series Horizon Series

Refrigerated Incubators / Environmental Testing Chambers

FITOCLIMA 600 & 1200 STABILITY

shaker LT-X (Lab-Therm) Space saving stackable incubator shaker

BLOOD PRODUCT STORAGE.

Undercounter Refrigerators and Freezers. Laboratory/Pharmacy Blood Bank. TrueBlue. Reliability & Support. i.series Horizon Series Scientific Series

TESTING FITOTERM FITOCLIMA TEMPERATURE / HUMIDITY CONTROL REACH-IN ENVIRONMENTAL CHAMBERS FOR CLIMATE AND TEMPERATURE TESTING

FREE ZERS LABORATORY FREEZERS -30 O C. i.series TM Horizon Series TM

External Dimensions: B = 750 mm D = 700 mm H = 2100 mm. Internal Dimensions: B = 600 mm D = 580 mm H = 1270 mm. Temperaturerange: 2 C to 20 C

Plant growth chambers

WR-KWAP (Platelet incubator/agitator) HPL

Chromatographic Air circulated Refrigerator, two-door TC 603

Natural convection, Film type heater. Amb. +3 to 60 / Amb to , 0.3, 0.1 at 37 / 0.36, 0.54, 0.18 at 98.6

Laboratory & Pharmacy Refrigerators

Upright Refrigerators. Blood Bank. TrueBlue. Reliability & Support. i.series Horizon Series

Advance Blood Storage system from Meditech

Laboratory Pharmacy Blood Bank. Upright Refrigerators and Freezers

FITOCLIMA 600 & 1200 STABILITY

FITOCLIMA 600 & 1200 BIO

Biomedical Freezer 37 38

TESTING FITOTERM FITOCLIMA TEMPERATURE / HUMIDITY REACH-IN CHAMBERS FOR ENVIRONMENTAL TESTING

shak er LT-X (Lab-Therm) Space saving stackable incubator shaker

Rieger. Industrievertretungen GmbH. Vertrieb durch: Ihr Anbieter für Geräte im Bereich Labor, Mikrobiologie und Industrie. Wir sind für Sie da:

Medical Refrigerators

Thermo Scientific Laboratory Products

BUSINESS SOLUTIONS. Biomedical REFRIGERATORS & FREEZERS FOR BIOMEDICAL NEEDS

Shaking water baths. OLS26 Orbital/Linear shaking water bath. LSB12 & LSB18 Linear shaking water baths

incubator, the best in its class

Pharmaceutical Refrigerators* and Freezers. *according to DIN 58345

SHAKING WATER BATHS ENGLISH

Constant climate chambers

Pharmaceutical Refrigerators* and Freezers. *according to DIN 58345

Laboratory & Process Equipment

FITOCLIMA 600 & 1200 PHARMA

Heated and Refrigerated Incubators

Natural convection, Film type heater. Amb. +3 to 60 / Amb to , 0.3, 0.1 at 37 / 0.36, 0.54, 0.18 at 98.6

MS Mini Incubator MO-MINI. Incubator. Specification. Ordering Information. Accessories

ISF1-X (Climo-Shaker)

Fri.med. Srl Via Riva, 26/ Buttigliera d Asti (AT) Italy Tel Fax

External and internal circulation with powerful pumping capability

Pass-Thru Refrigerators. Pharmacy & Blood Bank. TrueBlue. Reliability & Support. i.series Horizon Series

Protect your research

EC 160 CO 2. Incubator

FitoClima / FitoTerm SOL chambers

ISF4-X (Climo-Shaker)

Ultra low temperature freezers -40 C and -86 C. NEXUS Series

Ultra Low Freezers. Blood Management Solutions. B Medical Systems U Range

Blood bank refrigerators

TwinGuard ULTRA LOW TEMPERATURE FREEZERS SERIES

Blood Bank Refrigerators

Internet. Climate rating definitions. Customer service.

LR range (solid door) LR 750 G / GG

OLS26 Aqua Pro Orbital / Linear shaking bath. Offering ultimate flexibility and usability for all applications

NEW! Thermo Scientific Revco PLUS Ultra-Low Temperature Upright Freezers. Maximizing Critical Sample Protection and Storage

A T L A S - SolarClimatic Test Cabinet SC 2000 MHG

NEW! Thermo Scientific Revco PLUS -86 C Freezers. Protecting Your Life s Work

Laboratory Refrigerators and Freezers. Also with explosion-proof interior

Laboratory Refrigerators

www

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

Ultra Deep Freezers -86 C. Biomedical Refrigeration I UF. Technology for life _8pages_dometic_UF.indd 1 10/09/08 11:17:32

REFRIGERATOR P H A R M A C Y.

Laboratory Freezers. Medical Refrigeration. B Medical Systems F Range

Transcription:

Horizontal shakers for platelet bags APL-54 and APL-108 HORIZONTAL MOVEMENT AT A FIXED SPEED OF 66 R.P.M., LATERAL SHUFFLE OF 40 MM. APL-54 : CAPACITY FOR 54 PLATELET BAGS. APL-108 : CAPACITY FOR 108 PLATELET BAGS. Platelet bags constant shaking for long periods of time. Epoxy covered case with treated aluminium platform with AISI 304 stainless steel racks for bags. Stirring automatic restart in 30 seconds and pause device for bags handling. Acoustic alarm in case of power failure. LCD display informing of the events log: it counts the number of power failures and their duration. When power is restored, the device automatically restarts the stirring. Single button to adjust: -Date and time programmation. -Moving to review the number of incidences. -Shaking stop button for 30 seconds. -Shaker stop time programmation. -Alarms reset. S Part No. Nº of Capacity Height / Width / Depth Power Voltage Weight Shelves bags Cm. W V Kg APL-54 3000980 9 54 40 44 39 50 230 22 APL-108 3000981 18 108 40 84 38 50 230 35 It can be supplied for 110 V- 60 Hz on demand. Incubation chamber PLX-IN FOR PLATELET BAGS APL-54 SHAKING, CAPACITY 54 PLATELET BAGS. FOR REGULABLE TEMPERATURES FROM 18 ºC UP TO 60 ºC. RESOLUTION 0,1 ºC. STABILITY ±0,1 ºC. HOMOGENEITY ±0,5 ºC. SET ERROR ±0,3 ºC. Peltier effect. No compressor group. Quiet, vibrations free, high accuracy and low consumption. Made of transparent methacrylate with swinging door that allows an easy access to the working area and an inside chamber view during bags shaking. AISI 304 stainless steel lower base. Auto shut-off protective device in case of door opening and automatic restart in 30 seconds. Start-up main switch with digital temperature regulation. Part No. Height / Width / Depth Height / Width/ Depth Power Weight (exterior) cm (interior) cm w Kg 3000958 44 63 65 33 60 50 360 38 It can be supplied for 110 V- 60 Hz on demand. Note: For a correct bag preservation, it is recommended to keep a temperature between 20 and 24 ºC. Incubation chamber PLX-IN Part No. 3000958 with APL-54 shaker Part No. 3000980 Haematology

Platelet bags incubated cabinets Blood Bank E and F EXCLUSIVE DESIGN ADAPTED TO ACCOMODATE PLATELET BAGS STIRRERS APL. FORCED AIR CIRCULATION. FIXED TEMPERATURE AT +20 C. STABILITY ±1,5 C. RESOLUTION 1 C. SEVEN DAYS GRAPHIC TEMPERATURE REGISTER. SAFETY: LOW TEMPERATURE THERMOSTAT LIMITER. VISUAL AND ACOUSTIC INDICATORS: EXCESSIVE LOW TEMPERATURE (+18 C), EXCESSIVE HIGH TEMPERATURE (+24 C), OPEN DOOR, MAINS FAILURE AND BATTERY FAILURE. TEMPERATURE GRAPHIC REGISTER. 7 DAYS RECORDER, AUTONOMY 6 MONTHS. ACOUSTIC ALARM ON ALL FAIL CONDITIONS. ACOUSTIC INDICATOR. Model E APPLICATIONS Storage cabinet specially designed for platelet bags preservation. COMMON AISI 304 stainless steel external cabinet and internal lining. Double glazed door, reversible lockable door, easy to change, with automatic feedback mechanism and manual locking. Hermetically sealed compressor mounted on antivibration settlement with forced type evaporator and ventilated type condenser. Shelves and supports in steel PVC laminated. 2 power outlet base for model Blood-Bank E max. power 500 W 6 power outlet base for model Blood-Bank F max. power 500 W Inner air circulation for a more temperature homogeneity. Refrigerant R134a. Temperature sensors located in similar conditions to platelet bags. Circular graphic register built-in. Microprocessor temperature control that allows configuration and visualization of the following parameters by means of the display: - Entry code. - External alarm signal. - SET adjustment. - Alarm adjustment. - Calibration. 1. Digital display 2. Battery life indicator. 3. Open door indicator. 4. Mains failure indicator. 5. Increase value button. 6. Decrease value button. 7. Validate / RESET alarm. 8. Seven days graphic register. 1 2 3 4 5 6 7 8 Model F OPTIONAL COMPLEMENT Alarm messages transmision Automatic transmission system of alarm or incident SMS messages by using a GSM module SIM card activated. Ability to connect up to 2 phones. GSM Module. Part No: 2101622 S Part No. Capacity Capacity Height / Width / Depth Height / Width / Depth Power Power Number Weight litres stirrers (interior) cm (exterior) cm W HP of shelves Kg Blood Bank E 2101509 600 2 x APL-54 136 58 69 207 70 82 350 3/8 2 115 Blood Bank F 2101510 1300 4xAPL-54 o 2xAPL-108 136 128 69 208 140 82 1100 3/8 2 190 They are supplied with trays.

Blood bank refrigerated cabinets Blood Bank A, B, C and D FORCED AIR CIRCULATION. FIXED TEMPERATURE +4 C. STABILITY ±1.5 C. RESOLUTION 1 C. SEVEN DAYS GRAPHIC TEMPERATURE REGISTER. CAPACITIES FROM 90 TO 480 BLOOD BAGS. SAFETY: ALARMS SYSTEMS VISUAL AND ACOUSTIC: LOW TEMPERATURE (+2 C), OVER TEMPERATURE (+6 C), DOOR OPEN, MAINS FAILURE AND BATTERY FAILURE. INDEPENDENT BATTERY BACKUP GRAPHIC TEMPERATURE REGISTER. 7 DAY RECORDER, AUTONOMY 6 MONTHS. ACOUSTIC ALARM ON ALL FAIL CONDITIONS. REMOTE ACOUSTIC ALARM. Models A and B with optional drawer rack. Model C Model D APPLICATIONS AISI 304 storage cabinets specifically designed and manufactured for blood bag storage. COMMON Stainless steel. AISI 304. external cabinet and interior lining. Double glazed antimist, reversible lockable door, easy to change, self close door if left ajar. Hermetically sealed compressor mounted on shock absorbers with evaporator and forced air condenser. Fan air circulation maintaining homogeneous temperature distribution. Refrigerant R134a. Temperature sensors are located and calibrated to read simulated blood bag conditions. Independently powered circular graphic register. Microprocessor controlled temperature control via a display that can configure the following parameters: - Open code. - Activate external alarm. - Adjust SET. - Adjust alarm. - Calibration. 1. Digital display 2. Battery life indicator. 3. Open door indicator. 4. Mains failure indicator. 5. Increase value button. 6. Decrease value button. 7. Validate / RESET alarm. 8. Seven days graphic register. 1 2 3 4 5 6 7 8 OPTIONAL COMPLEMENT Alarm messages transmision Automatic transmission system of alarm or incident SMS messages by using a GSM module SIM card activated. Ability to connect up to 2 phones. GSM Module. Part No: 2101622 S Part No. Capacity Capacity Height / Width / Depht Height / Width / Depht Power Power Number Weight litres bags (interior) cm (exterior) cm W HP of shelves Kg Blood Bank A 2101497 319 110 139 48 45 198 60 64 360 1/4 5 98 Blood Bank B 2101498 442 150 126 58 55 198 70 71 360 1/4 5 111 Blood Bank C 2101499 600 200 136 58 69 207 70 82 350 3/8 5 115 Blood Bank D 2101500 1300 480 136 128 69 208 140 82 1100 3/8 10 190 Comes complete with steel shelves, PVC laminated.

OPTIONAL ACCESSORIES, Metallic drawers, to be ordered separately. Modular rack system of drawers, divided into compartments and subdivided by plastic dividers for different bag classification, bags are placed upright longitudinal. Blood Bank A, System of 5 drawers of 18 bags per drawer. Capacity 90 bags. Part No 1001501 Blood Bank B, System of 5 drawers of 30 bags per drawer. Capacity 150 bags. Part No. 1001502 Blood Bank C, System of 5 drawers for 40 bags per drawer. Capacity 200 bags. Part No. 1001503 Blood Bank D, System of 12 drawers (6 in each compartment) for 40 bags per drawer. Capacity 480 bags. Part No. 1001504 Detailed image of the drawers with dividers. Models A and B with optional rack system. SPARE PARTS Brackets and shelves For Bloodbank code 2101497 2101498 2101499 / 2101500 Brackets - 4 units 1001801 1001801 1001801 Shelves 1001804 1001805 1001806 Each shelf requires 4 brackets. Shaking monitor for blood collection HEDO2 FOR BAGS BLOOD COLLECTION PROCESSES. SWINGING PLATFORM. HEDO2 is a digital blood collection monitor, created to control and monitoring blood collection processes. It has been designed to perform simple, precise and accurate operations. It is composed of: -Easily removable tray. -Wired or wireless interface networking. -Automatic clamp closing at the end of the donation. -Automatic tare calculation. -Real time monitoring of the donation showed on the digital display. -Stand alone mode (operating with rechargeable battery). 8 hours life. -Tube sensor presence. Power supply: 110-220V / 50-60 Hz. Part No. Max weight Precision Resolution Height / Width / Depth Power Weight Capacity g g g (external) cm W Kg 5010000 999 ± 3 1 19 32 32 60 5 It is supplied with a transport suitcase. ACCESSORIES Wireless data transfer Hedo-2. Part No. 5010001 Wireless connection module Hedo-2. Part No. 5010002 Barcode reader Hedo-2. Part No. 5010003 Alarm lamp pool Hedo-2. Part No. 5010004

Plasma bags defrost baths and temperature controllers for red cells packed Unitronic-OR UNITRONIC-OR-4 CAPACITY FOR 4 BAGS. UNITRONIC-OR-12 CAPACITY FOR 12 BAGS. SHAKING SPEED, TIME AND TEMPERATURE DIGITAL ELECTRONIC REGULATION. FOR REGULABLE TEMPERATURES FROM AMBIENT +5 UP TO 36 ºC. STABILITY ± 0,05 ºC. HOMOGENEITY ± 0,1 ºC. SET TEMPERATURE ERROR ± 1 ºC. RESOLUTION 0,1 ºC. SAFETY: NORMA DIN 12879.0. SAFETY THERMOSTAT ADJUSTABLE WITH MANUAL RESET FOR SWITCHING THE BATH OFF IN CASE OF OVERTEMPERATURE. Regulable reciprocal shaking from 10 to 70 oscillations per minute Controllable time from 1 minute up to 99 hours 59 minutes. End of cycle acoustic alarm S Part No. Bags Height / Width / Depth Power Weight capacity (exterior) cm W Kg OR-4 3001250 4 40 54 44 1500 25 OR-12 3001251 12 40 74 44 2000 34 Linear motion shaking tray from 10 to 100 oscillations per minute, with a variable stroke length of 32 or 46 mm. Digital selection and reading of temperature, speed and time. Temperature sensor: Pt 100 thermo-resistant. RS-232 outlet for parameter s reading and printing in a computer. External case of AISI 304 stainless steel. Internal tank with an AISI 304 stainless steel rack for the correct accommodation of plasma bags. Drain tap built-in. 1. Main switch selector. 2. LCD screen that shows: - Temperature, oscillations and time. - Alarms: probe and temperature failure. - Configuration: C or F, calibration and working limits. 3. Start / Stop button. 4. Parameter value decrease button. 5. Parameter value increase button. 6. Temperature, oscillations and time selector button. 7. Configuration button. 1 7 6 5 4 3 2 Blood bags tube automatic sealer Sealcom-B FOR TUBES FROM Ø 3 TO 6MM. Metal epoxy covered external case. AISI 304 stainless steel sealing head. A microprocessor provides an automatic sealing by dielectric heating when inserting part of the tube in the piston. Sealing time from 1 to 2 seconds. Part No. Sealing Height / Width / Depth Power Weight width mm Ø (exterior) cm sealing W Kg 5800060 3 to 6 15 16 34 400 7 Main switch, with light indicator. Light indicating operation, sealing and end of sealing. Manual plasma extractor PR-B EASY TO USE MANUAL SYSTEM THAT ACCEPTS ALL KINDS OF PLASMA BAGS. TRANSPARENT PLATFORM FOR VISUAL CONTROL OF THE PLASMA. STAINLESS STEEL AISI 304 CABINET. Part No. Height / Width / Depth Weight (exterior) cm Kg 5800061 25 17 30 2,6