FIRE PROTECTION OF ROLLING STOCK Christoffer Nylander

Similar documents
A Study into the Standardization of Using Fire Detectors in Rail Vehicles for China

FOGTEC Rail Systems. Rolling Stock Applications. Fire Protection Solutions from one source. Leading in Fire Protection

Fire Detection and Fire Fighting Testing and Approval on Railway Vehicles

TALK SAFETY WITH US MARINE SAFETY TECHNOLOGY. When Safety Matters

designed for rail 5000 Series

Directories. B.1 Keyword Directory B.2 Tables B.3 Figures B.4 End Notes Fire Safety Guide / Siemens Switzerland Ltd

FIRE CONTAINMENT AND CONTROL SYSTEMS

GO TOGETHER WITH CONSILIUM SUPERIOR ROLLING STOCK SAFETY SOLUTIONS

ITALIAN STANDARD UNI 11565

Fire is No Accident Fire is No Accident It can be prevented.


APPLICATION BULLETIN COMBUSTION TURBINE FACILITIES. Overview

IBC Committee Responsibility Matrix January 2017

COMMON SENSE FIRE PREVENTION MEASURES FOR SOLID WASTE OPERATORS Presented by the Sacramento County LEA Program and Sacramento Fire Department

International Water Mist Conference, Istanbul October 22-23, 2014 The background and development of the guidelines in IMO Resolution A.

ON-TRACK FOR TAILORED FIRE PROTECTION. Future-proof fire protection solutions for rail vehicles

OFFSHORE SUPPORT VESSELS 2014

Fire Prevention. Risk Management Services. October 7-13, 2012 National Fire Prevention Week National Fire Protection Association

NFPA 72 is in the same cycle as NFPA 80. The extracted text will be updated with a Second Revision during the second draft meeting.

FIRE SUPPRESSION SOLUTIONS

FlameGard 5 MSIR HART

Availability, Reliability, False Alarm Resistance Best Practice in Fire Alarm Systems. FIRE PROTECTION OF ROLLING STOCK 2 rd March 2017

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT NEW BUILDINGS

Building and design of buses and coaches, keeping fire safety in mind. Fredrik Rosen, SP Technical Research Institute of Sweden

FIRE SAFETY INSPECTION REPORT

FIRE PREVENTION AND SAFETY IN THE HOME CW2 BILL GUNNETT

Fire protection for rolling stock. Innovative solutions from Siemens Building Technologies. Answers for infrastructure and cities.

PROJECT: CIVIC ADDRESS:... PERMIT APPLICATION NO.: DATE:... CRP:. Certified Professional:.

DC3Training.com N28AA DC-3 Pilot s Handbook

MOBILE FOOD SERVICE EQUIPMENT FIELD APPROVAL SUBMISSION INFORMATION

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT HORSEFAIR HOUSE

The Science Behind Water Mist Protection of Typical Building Hazards

FIRE SAFETY PLAN PART 1 BUILDING INFORMATION SECTION

FOGTEC Rail Systems. Rolling Stock Applications. Fire Protection Solutions from one source. Experts in Fire Protection

K Series - Fire Suppression Systems for the Catering Industry

FIRE RISK ASSESSMENT NOT KNOWN 15/10/ SOMERTON COURT BROADMOSS DRIVE SIMON ROFFEY

Fireward Fixed Fire Fighting System. For Open Areas & Enclosed Risks fireward.co.uk

Fire Risk Assessment 2017

St. John s University

St. John s University

Code of practice for fire precautions in the design and construction of passenger carrying trains

Certificate of Approval

St. John s University Fire Safety Plan

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT SPORTS CENTRE

Fire Protection Systems For Railway Vehicles WE ARE ENSURING FIRE SAFETY

5 Key Stages to Risk Assessment

Fire Safety PPT-SM-FIRESFTY V.A.0.0

Turning expertise and innovations into marine solutions

Fire safety management issues identified by fire risk assessments

1970s building housing main school reception and support offices. Well managed buildings with no significant risk of a fire occurring.

Leader s Guide 2007 CLMI Training

IMO UNIFIED INTERPRETATIONS TO SOLAS CHAPTER II-2 AND RELATED FIRE TEST PROCEDURES

Detection of Fires in Heavy Duty (HD) Vehicles

Well managed building mean risk is normal. Fire action notices should be displayed by all alarm break glass call points.

THE REPUBLIC OF LIBERIA LIBERIA MARITIME AUTHORITY

Chapter 2: Definitions

Azayaka Aneka Sdn. Bhd. Azayaka Aneka Tissue Paper. Azayaka Aneka Paper Towel Dispensers. 1 of 7

St. John s University Fire Safety Plan

FIRE SAFETY INSPECTION REPORT

Fraternity, Sorority and Dormitory Buildings R-2 Fire and Life Safety Standards Inspection Form Fire Code of New York State (19 NYCRR Part 1225.

BC Building Code Checklist Part 3 Planning and Development Department

Traction Cable Radox 3 GKW

Martin Huber 26September 2017 F&G SOLUTIONS FOR THE PROCESS INDUSTRY

D Safe, realistic, reliable DRÄGER FIRE TRAINING SYSTEMS

Firefighting operations on multi-tiered vehicle stacking buildings F5-13 GD

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT NO 68 (ENGLISH AND PHILOSOPHY)

Jonathan Redding Area Sales Manager FOGTEC Fire Protection Cologne, Germany

SP METHOD 5320 Issue No: Test method for fire detection systems installed in engine compartments of heavy vehicles

Volume Sensor Multi-sensor, Multi-criteria Event Detection

Vehicle Fire, Safety and Evacuation

Underground fires in metro systems failures, accidents and terrorism

Element C3.4 Fire Fighting Equipment

EC EP 14 All other electrical K-920 equipment in patient care vicinity NFPA , Chapter 10

Crossrail Project. Infrastructure design and construction Volume 5. Edited by Professor Rhys Vaughan Williams and Mike Black

YUHUA PRE-HEATER ALWAYS THE RIGHT ANSWER

TUNPROTEC. Active Tunnel Fire Protection

Fire protection solutions for ships and offshore facilities

The Social Accountability International (SAI) Fire Safety Checklist

NYU RESIDENTIAL FIRE SAFETY PLAN PART I - BUILDING INFORMATION SECTION

Fire Safety. Version 1.0

Smoke Alarm User s Manual

Xavier Field Office Fire Prevention Plan. for. Xavier Field Office Dana Avenue

Basic Vehicle Fire Protection Manual

MSA Gas Detection. for the Water and Wastewater Industries. Does your facility meet NFPA 820?

Fire Safety Compliance

Chapter 17 Test. Directions: Write the correct letter on the blank before each question.

A comprehensive systems-level approach in cabin design minimizes fire potential and helps ensure passenger safety. aero quarterly qtr_04 11

Solutions. Fire risk under control in welding fume extraction systems

Hazardous Material Safety Program

Firefighting. It is the temperature at which a substance will continue to burn, when ignited.

Box-in-Box Cold Storage Fire Protection Options

DEPARTMENT SUMMARY. Personnel Services $ 7,780,971 $ 7,989,600 $ 7,707,680 $ 8,231,680. Operating Expenses 835, , , ,870

Cadet Entry Level Award(ELA) Part Four. Fire Safety

Questions for the HFD regarding Bill 69, Evaluation Worksheet for High-Rise Residential Buildings User s Guide ( New User s Guide or NUG )

InstrumentationTools.com

Managing Fire Safety To Ensure Legislative Compliance

Fire Safety Education in Multi- Unit Residential Buildings

St. John s University

REGISTRATION EXAMINATION, JUNE 2015 LICENSED GASFITTER ANSWER SCHEDULE

Osceola County Department of Fire Rescue and Emergency Medical Services

Transcription:

FIRE PROTECTION OF ROLLING STOCK 2017 Christoffer Nylander

CONSIDER EN45545-6 AND THE ANALYSIS NEEDED TO REACH A TAILOR MADE SOLUTION COVERING YOUR FIRE HAZARDS ONBOARD.

CONTENT Understanding the responsibility of how to fulfill EN45545-6 What data is needed to complete the hazard analysis? How to detect fire in different areas onboard a train? How to define that the area has an acceptable coverage?

FOR ALL THOSE MOMENTS WHEN SAFETY MATTERS. In the transport sector, you need access to service wherever you are. In the local language, with local knowledge. Our 24/7/365 worldwide local reach makes sure you are in safe hands. 19,500 Consilium offices Sales and service representatives

EN45545-6 WHAT IS MISSING TO REACH SAFE SYSTEM SOLUTION Table 1 - Fire detection Operation category Passenger areas Corridors Toilets Staff areas Cooking or catering area Combustion engines Technical cabinets containing traction equipment Other technical cabinets Design Categories N and D 1 X X 2 Xe Xc Xc X X X 3 Xce Xe Xc Xc X X X 4 Xce Xe Xc Xc X X X Design Categories S and DS 1 Xc X Xa X X X X Xb X 2 Xc X Xa X X X X Xb X 3 Xc X Xa X X X X Xb X 4 Xc X Xa X X X X Xb X Design Category A 1 X X X 2 X X X X 3 Xc X X X Xb X 4 Xc X X X Xb X Luggage compart ment N A D S

ALL TRAINS ARE UNIQUE

RESPONSIBILITY OR CONSULTATION? Unforeseen combinations of small things which can have a big effect on Fire detection performance

PRACTICAL DATA AND ASPECTS FOR THE OVERALL RISK MANAGEMENT. Risk identification Risk classification Risk evaluation Measures Follow-up Hazard analysis Risk management

Secondary top event Detectable medias Sensors System Smoldering fire Developed fire Gas release Smoke Heat Flame (IR, UV) Fuel leakages (Mist) Broken components Fire detection devices Fuel pressure sensor Heat sensors Vacuum sensors Fire detection system Engine controller (CAN BUS)

PASSENGER AREAS AND CORRIDORS Smoke Gives early detection for smoldering fires from arson or unintended source of fire. Point detection also give the possibility of a secure activation of suppression by voting. Heat To slow. Not recommended as single source of sensor. Can be combined with i.e smoke detector Flame Quick but requires open flame and visibility of all areas. Not recommended as only detector

LUGGAGE COMPARTMENT Smoke Gives early detection for smoldering fires from arson or unintended source of fire. Point detection also give the possibility of a secure activation of suppression by voting. Heat To slow. Not recommended as single source of sensor. Can be combined with i.e smoke detector Flame Quick but requires open flame and visibility of all areas. Not recommended as only detector

DRIVERS CAB AND STAFF AREAS Smoke Early detection for smoldering fires Heat To slow. Not recommended Flame Quick but since drivers cabin often got a lot of closed spaces it will not have an effective coverage.

ELECTRICAL CABINETS Smoke Early detection for smoldering fires Heat Rate of rise detection in combination with high fixed temperature detection. Combination with smoke detection Flame Quick but requires open flame. Not recommended as only detector

TOILETS Smoke Early detection for smoldering or arsonist fires i.e in paper baskets Heat To slow. Not recommended Flame Will detect open fire (arson) or people lighting cigarette

ENGINE AND TRACTION COMPARTMENT Smoke Early detection for smoldering fires. Can also detect oil leakage. Smoke extraction recommended. Heat Rate of rise detection in combination with high fixed temperature detection. Late but possible detection Flame Quick but requires open flame. Not recommended as only detector

EXTERNAL ENVIRONMENT Smoke Detection of smoke in air surrounding the train. Very harsh environment requiring protection of the sensor. Heat Not applicable Flame Not applicable

ACCEPTABLE COVERAGE OF FIRE PROTECTION SYSTEM ARGE EN 50553 Local experience and procedures. Etc.

SUMMARY Challenges of practicing EN 45545-6 related with responsibility and consultation. Different aspects of unique hazards and conditions. How to detect fire in different areas of the train and how to ensure proper coverage.