AGENDA. 1. Call to Order. 2. Approval of Minutes. 3. Approval of Invoices and Commitments. 4. Review Updated Site Analysis and Permitting

Similar documents
Appendix B. Facilities Assessment Report

State College Area School District High School South Building EXISTING CONDITIONS ASSESSMENT

State College Area School District High School North Building EXISTING CONDITIONS ASSESSMENT

VOTER BOND REFERENDUM 2018 SUMMARY OF WORK PROPOSED

MUKWONAGO AREA SCHOOL DISTRICT CAPITAL IMPROVEMENT / MAINTENANCE STUDY

MOUNT PLEASANT MIDDLE SCHOOL HVAC. M-01 Heating Plant: M-02 Heating & Ventilating Systems: Livingston School District Mount Pleasant Middle School

Florence High School / Middle School Page 1 of 3 Florence, WI

Lincoln Public Schools

NYC Department of Education

LINCOLN HIGH SCHOOL MODERNIZATION BEX IV COMMUNITY MEETING JUNE 23, 2016

Tighe&Bond. Groton Heights School Mechanical Evaluation. 1 Existing Conditions. 1.1 Water Service Entrance

NYC Department of Education

Massachusetts School Building Authority

Allisonville Elementary School Facilities Highlights Built: 1960 Last Major Renovation: 28 years ago Capacity: 650 Current Enrollment: 767

Mechanical System Description

NYC Department of Education

Sprinkler: The building does not have a fire protection system installed. MECHANICAL / PLUMBING / SPRINKLER SYSTEMS RECOMMENDATIONS

3. 21st Century Learning A. Districtwide Flexible Learning - Allowance for Flexible Furniture $600,000 Subtotal $600,000

HOLUM EDUCATION CENTER. Architectural. January 13, 2014 DeForest Area School District

MID MICHIGAN COMMUNITY COLLEGE HARRISON CAMPUS Harrison, Michigan 2015 MASTER PLAN

GARCIA GALUSKA DESOUSA Consulting Engineers

NYC Department of Education

Joseph Brennemann Elementary School

NYC Department of Education

NYC Department of Education

GARCIA GALUSKA DESOUSA Consulting Engineers

NYC Department of Education

Josefa Ortiz De Dominguez Elementary School

Richard Henry Lee Elementary School

NYC Department of Education

NYC Department of Education

PLAN REVIEW SUBMITTAL GUIDE

NORTH CENTRAL MICHIGAN COLLEGE PETOSKEY CAMPUS. Facilities Conditions Assessment Mechanical And Electrical Petoskey, Michigan

Charles W Earle Elementary School

SCO # 1 & 2 PUNCLH LIST Project Name: VANCLEAVE UPPER ELEMENTARY CLA#: 13003

Agustin Lara Elementary Academy

Mechanical Inspection Plumbing

NYC Department of Education

NYC Department of Education

Calmeca Academy of Fine Arts and Dual Language

NYC Department of Education

Element Z General Design Requirements Existing Facilities Information

NYC Department of Education

NYC Department of Education

S AGE E NGINEERING A SSOCIATES, LLP

Ohio Department of Health, Bureau of Environmental Health and Radiation Protection, Radon Licensing Program. School Radon Testing Checklist

Chariho Regional School District Five-Year Capital Facilities Improvement Plan (2/10/15)

Standard of Practice - Fire Alarm Systems. NOTE: Significant revisions or additions to the previous standards are highlighted in italics.

NYC Department of Education

DESIGN AND CONSTRUCTION STANDARDS GENERAL DESIGN GUIDELINES

CONNECTICUT. Downloaded

Element Z General Design Requirements Existing Facilities Information

NYC Department of Education

Genevieve Melody Elementary School

If there are emergency situations they should be reported to Maintenance Department immediately.

NYC Department of Education

Meadow Point Elementary School East Grand Avenue Aurora, Colorado 80015

LIGHT LEVEL REQUIREMENTS MINIMUM ACCEPTABLE FOOT CANDLES

DOCUMENT TABLE OF CONTENTS

NYC Department of Education

2014 Bond Project Guide

Bethel School District Radon Testing Plan

NYC Department of Education

NYC Department of Education

Sagebrush Elementary School East Temple Place Aurora, Colorado 80015

F. GENERAL REQUIREMENTS Electrical Design Criteria 2006 Edition 4/3/06 School District Palm Beach County Page-1 of 15

Master Facility Planning Update School Board Meeting May 26, 2016

NYC Department of Education

Construction standards and qualities

PLATTEVILLE MIDDLE SCHOOL

NYC Department of Education

Edward Jenner Elementary Academy of the Arts

NYC Department of Education

NYC Department of Education

NYC Department of Education


Gulfport, Mississippi 21 May 2007

LIGHTING CONTROLS

NYACK PUBLIC SCHOOLS CAPITAL IMPROVEMENT PLANNING PROCESS

NYC Department of Education

Princeton Joint Unified School District Invitation for Bid Installation of District-Wide Lighting Occupancy Sensors

Cook - Wissahickon Elementary School

NYC Department of Education

NYC Department of Education

White Bear Lake Area Schools District 624 ENERGY GUIDELINES

Demonstration and Training of MEP Systems Page 1 of 15

NYC Department of Education

Oscar DePriest Elementary School

AN ORDINANCE TO AMEND CHAPTER 7-BUILDING REGULATIONS, ARTICLE 1-UNIFORM CONSTRUCTION CODE, SECTION 7-2 -FEES TO ESTABLISH A NEW FEE SCHEDULE

Brown University Revised June 29, 2012 Facilities Design & Construction Standards SECTION ELECTRICAL DESIGN CRITERIA

University of Illinois Business Instructional Facility LEED Gold Design. University of Illinois Business Instructional Facility

SECTION HVAC TABLE OF CONTENTS PART 1 - SYSTEM DESCRIPTION / OUTLINE SPECIFICATIONS FILED SUB BID PROJECT OVERVIEW...

NYC Department of Education

CLEVELAND HEIGHTS UNIVERSITY HEIGHTS CITY SCHOOL DISTRICT MONTICELLO & ROXBORO MIDDLE SCHOOLS INTERIOR DESIGN

Certificate of Completion

MINOOKA FIRE PROTECTION DISTRICT Fire Prevention Bureau Fire Inspector Rodney Bradberry

NYC Department of Education


F. GENERAL REQUIREMENTS Electrical Design Criteria 2009 Edition 11/23/2009 School District Palm Beach County Page-1 of 17

Washington Irving Elementary School

Transcription:

PROJECT MANAGEMENT AGENDA Project: George Keverian School Feasibility Study Project No.: 16049 Re: School Building Committee Meeting Meeting Date: 3/22/2017 Meeting Location: Mayor s Conference Room, City Hall, Third Floor Prepared by: Joel Seeley Meeting Time: 3:30 PM Distribution: Committee Members (MF) 1. Call to Order 2. Approval of Minutes 3. Approval of Invoices and Commitments 4. Review Updated Site Analysis and Permitting 5. Review Updated Building and Site Design 6. Review Cost Estimates 7. Vote the Preferred Construction Alternative 8. Vote to Submit Preferred Schematic Report to MSBA 9. Committee Questions 10. Public Comments 11. Next Meeting: April 12, 2017 12. Adjourn JGS/sat/P:\2016\16049\04-MEETINGS\4.2 Agendas\3-School Building Committee\2017\15_22March2017_Schoolbuildingcommittee\Agenda_22March2017_Revised.Docx

SCHOOL BUILDING COMMITTEE GEORGE KEVERIAN SCHOOL All meetings held at the Mayor s Conference Room, City Hall, Third Floor at 3:30 PM unless otherwise noted DATE Schematic Design Phase (SD) April 12, 2017 April 26, 2017 May 10, 2017 May 10, 2017 May 24, 2017 June 7, 2017 June 15, 2017 June 21, 2017 June 29, 2017 MEETINGS SCHEDULE AND AGENDAS March 7, 2017 AGENDA SCHOOL BUILDING COMMITTEE MEETING Review Schematic Design Phase Schedule and Deliverables Review Updated Site and Floor Plans Decide Construction Delivery Method Review Preliminary Exterior Elevations and Building Sections SCHOOL BUILDING COMMITTEE MEETING Review Updated Site Plan and Floor Plans Review Site Utilities Plan Review Updated Exterior Elevations and Building Sections Review Sustainable Design Features MSBA BOARD MEETING SCHOOL BUILDING COMMITTEE MEETING Review Updated Site Plan and Floor Plans Review Updated Exterior Elevations Review Mechanical and Electrical Systems Review Preliminary Technology Systems SCHOOL BUILDING COMMITTEE MEETING Review Updated Site Plan and Floor Plans Review Updated Site Utilities Plan Review Structural Systems Review Updated Exterior Elevations Review Preliminary FFE Layout DRAFT SCHOOL BUILDING COMMITTEE MEETING Final Site Plan, Floor Plans and Elevations Final Structural Systems Final Mechanical and Electrical Systems Final Project Cost Final Project Schedule Vote to submit Schematic Design Cost Estimate to MSBA SUBMIT SCHEMATIC DESIGN COST ESTIMATE TO MSBA SCHOOL BUILDING COMMITTEE MEETING Vote to submit Schematic Design Package to MSBA SUBMIT SCHEMATIC DESIGN PACKAGE TO MSBA ADDITIONAL MEETINGS TO BE SCHEDULED PROJECT MANAGEMENT

February 24, 2017 George Keverian School City of Everett, MA M O U N T V E R N O N G R O U P A R C H I T E C T S 2 0 0 H A R V A R D M I L L S Q U A R E S U I T E 4 1 0 W A K E F I E L D, M A 0 1 8 8 0 RE: PRELIMINARY REVIEW OF PROPOSED STRUCTURAL & MEP BUILDING SYSTEMS SCHOOL BUILDING COMMITTEE MEETING FEBRUARY 22, 2017 7 8 1. 2 1 3. 5 0 3 0 T 7 8 1. 2 1 3. 5 0 4 0 F STRUCTURAL BUILDING SYSTEM Structural system for the proposed building will include reinforced concrete footings and foundation walls with reinforced slab at grade for the underground parking garage. Reinforced concrete columns will make up the structural grid at the parking garage ground level and support the first floor, constructed as a reinforced concrete slab, along with the upper floors of the school building constructed of steel frame. PLUMBING SYSTEM A complete domestic cold water system throughout the new building. The system will require a service from the street main; a pressure reducing station; and divided for domestic potable and laboratory non-potable usage complete with state approved backflow preventers. Connections will be made to all equipment requiring cold water. A complete domestic hot water system throughout the new building. The system shall have all state approved backflow preventers. The system shall be dual temperature; 120F for general use by the public, student and faculty; and 140F for kitchen sinks and janitors sinks, 180F will be supplied by separate booster heaters at dishwashers. A complete sanitary, soil, waste and vent system connected to each fixture. The system will extend and connect to the sanitary main 10-0 outside of the building. Waste piping from selected kitchen equipment will flow to an interior and or exterior grease interceptor prior to connection to the building sanitary system. A complete storm water system throughout the entire building connecting to each and every roof and areaway drain requiring storm drainage. Connect to main storm drain 10-0 outside of building Toilet room fixtures to be automatic flush, hands free Hot water shall be generated by gas condensing type fired water heater W W W. M V G A R C H I T E C T S. C O M

MECHANICAL SYSTEM M O U N T V E R N O N G R O U P A R C H I T E C T S The central heating system of the school will consist of gas-fired, hot water, high efficiency boilers. Heating and dehumidification for the classrooms will be provided by packaged roof top units and perimeter finned tube radiation. Each classroom will be served by a displacement ventilation diffuser which will deliver tempered and dehumidified ventilation air from the roof top units. Dedicated roof top units will be provided for the Library, Gymnasium, Cafeteria and Music rooms The building will be provided with a direct digital control system for monitoring and controlling all the major HVAC equipment. The DDC system provides graphic software for each piece of equipment. Individual room controls consist of a wall mounted thermostat with limited adjustment range. ELECTRICAL SYSTEMS A main switchboard shall be located in the main electrical room and have surge protection, digital metering and power distribution circuit breakers. Emergency power per oil/gas fired generator. The generator shall provide emergency power to all emergency lights and exit signs. The generator will also provide standby power to heating equipment, kitchen refrigerators, tele/data equipment rooms, fire alarm system and security system. Lighting system interior and exterior to be LED type lighting fixtures. Classroom light fixtures shall be controlled with day light harvest dimming controls, manual switches and occupancy sensors. Library, Cafeteria, Gymnasium and utility room light fixtures shall be controlled by local switches. Offices shall be dual switches and controlled by wall mounted occupancy sensors. Toilet fixtures shall be controlled by occupancy sensors and local keyed switches. Corridors by local switches and motion sensor inputs by the security system. Both exterior building and pole mounted lighting to be used around the perimeter of the building and at entrances all controlled by lighting control panels. Fire alarm system to be an addressable voice communication microprocessor based fire alarm system. The system will consist of a fire alarm control panel located in the main electric room, annunciator panels at the main lobby entries, speaker strobe devices throughout, pull stations at all exit doors, smoke detectors located in corridors, electric rooms and stairwells, and heat detectors in utility rooms. The system will alert the local fire department of an alarm condition via a fire alarm master box. William Peters Associate Principal Mount Vernon Group Architects, Inc.

Mount Vernon Group, Inc. 200 Harvard Mill Square Suite 410 Wakefield, Ma. 01880 Phone: 781-451-0228 Fax: 781-213-5040 E-mail: bpeters@mvgarchitects.com MEETING MINUTES No. 0004 PROJECT TITLE: LOCATION: MEETING DATE: SUBJECT: George Keverian School 121 Vine Street Conference Room 2/21/2017 (8:00 AM) Educational Review of Plans w/ Space Summary ATTENDEE INITIALS COMPANY INITIALS PRESENT Charles Obremski CO District ~ Assist. Suoerintendent of Business N Robert Moreschi RM District ~ Chief Procurement Officer N Kevin Shaw KS District ~ Assist. Superintendent Y Janice Gauthier JG District Y Patricia Masse PM District Y Joel Seeley JS Symmes, Maini & McKee Assoc. SMMA Y David Stephen DS New Vista Design NVD N Frank Tedesco FT Mount Vernon Group, Inc. MVG N Dennis Daly DD Mount Vernon Group, Inc. MVG Y Susan Taylor ST Mount Vernon Group, Inc. MVG N Al Cuevas AC Mount Vernon Group, Inc. MVG N William Peters WP Mount Vernon Group, Inc. MVG Y ITEM DESCRIPTION STATUS START DUE BALL IN COURT 04-01 Plan spaces and adjacencies discussed Comments based on Plans Attached for Cafeteria & Gymnasium at Grade level FIRST FLOOR Stairways to grade ~ Exit Only Provide Technology in Cafeteria Loading & Custodial Storage along service drive Access to custodial from main corridor Partition between Cafeteria & Gymnasium Mesh divider in gymnasium to provide separated practice courts 2 Fitness rooms on First Floor PK through 3rd grade pickup only. Parents must park their vehicle and student is released to sibling or parent SECOND FLOOR Move 1200SF Art room & Kiln Storage to Fourth floor w/ 6,7 & 8 th Grades Shift Sped classrooms and toilet to right hand side of neighborhood for each grade Swap Health Classroom to Grade 1 corridor and SG across from Nurse OT/PT & Staff Dining to be on Second Floor, swapped with Fitness Rooms Provide sensory room adjacent to stairwell THIRD FLOOR Provide a sensory room on the third floor and one on the second floor as indicated above Roof Play area with buffer zone between play area and classrooms adjacent Decrease Library by 1,000 SF, and provide (1) Teacher Work room on each floor at 450 SF FOURTH FLOOR 1200 SF Art room and Kiln/Storage moved to Luke Road/East side of building at area indicated as High Roof Move sensory room to third floor Page 1 of 1

MISCELLANEOUS ITEMS Folding partitions between (2) classrooms in each neighborhood should be stacked. Typical for three floors Interactive boards in Common & Team Areas typical Provide (1) 110 SF duplicating room on each floor Decrease Library by 1,000 SF, and provide (1) Teacher Work room on each floor at 450 SF Sensory Rooms to have glass in door with NO lock on door Prepared By: William Peters, Associate Principal - Mount Vernon Group, Inc. Dated: 03/15/2017 Note: All meeting minute items are correct and accurate unless the Author is notified in writing within 10 days Meeting Minutes Template template.doc Page 2 of 1