Intrinsically Safe or Explosionproof? Understanding the technology

Similar documents
UL Topic III. Converting European EEx Certificates. Into. North American Division Certificates

NON ELECTRICAL EQUIPMENT IN HAZARDOUS AREAS

INSTRUCTIONS FOR SAFE OPERATIONS LM3000 EXPLOSION PROOF LASER DISTANCE METER

Understanding Hazardous Locations Concepts

EUROPEAN DIRECTIVES Explosive atmospheres ATEX 2014/34/EU

Annubar Flowmeter Series

UL HAZARDOUS LOCATIONS SERVICES

Airo Wireless Intrinsically Safe White Paper. Written By: David Schmitt

Certificate of Compliance

SmartPower Solutions. Quick Start Guide , Rev CA March 2015

Smoke detection in hazardous areas:

Certificate of Compliance

Erik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories

Beamex. Calibration White Paper. Calibration in hazardous areas

Quick Start Guide For the

Beamex Calibration White Paper. Calibration in hazardous areas

SmartPower Solutions [ SmartPower Solutions. Quick Installation Guide , Rev AC January 2012

Electrical Installations Design, Selection, Erection and Inspection

INTRINSICALLY SAFE LIGHTING RANGE

IS (Intrinsic safety) - Ex (Epsilon x) ATEX CENELEC

SELECTION, INSTALLATION & TESTING OF ELECTRICAL EQUIPMENTS IN HAZARDOUS AREA

Guide to Explosion Protection and Plant Safety

Safety instructions VEGADIS DIS61.CC/O** VEGADIS DIS81.CC/O******

IECEx International Conference 2017 Shanghai, China. Electrical Installations Design, Selection, Erection and Inspection

MICROpeL 75 Combustible Gas Sensor Part Number: PM

Hazardous Areas - EXPLOSIONPROOF SOLENOIDS

Trusted worldwide since 1989 INTRINSICALLY SAFE RANGE

Seat Ventilation offers an extensive range of ATEX certified products and is undertaking great efforts to extend this range even further.

Today's world of increasing

Fieldbus Non-Incendive Concept takes FISCO into Zone 2 and Division 2 hazardous areas. Phil Saward

Selection of Explosion Protected Equipment for Hazardous Locations. Compiled by: Pieter Coetzee ZONE 2 ZONE 1 ZONE 0.

Guide to Intrinsically Safe Portable Radios

DB5 Intrinsically Safe Sounder Type DB-5

A Guide to Safe Electronic Weighing in Hazardous Locations

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

Intrinsically Safe Transmitters, Option Code 2n

INSTRUCTION MANUAL. SIL 3 - SIL 2 IIB Group Power Supply for Hazardous Area Equipment DIN-Rail Model PSD1001C PSD1001C

INSTRUCTION & SERVICE MANUAL

FINAL ATEX REPORT ON EQUIPMENT FOR USE IN POTENTIALLY EXPLOSIVE ATMOSPHERES FOR GOLDEN PROMISE EQUIPMENT INC. FLOW MONITOR, GPE3000 SERIES,

YTA Series Temperature Transmitters [Style: S3] EN :2006, -11:2007, -26:2007. Supply circuit: Ui=30 V, Ii=165 ma,

RADAR LEVEL GAUGE SPECIAL SAFETY INSTRUCTION

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

Safe Operation Manual. Honeywell IQ Force Gas Detector

A guide to the use of electrical equipment in potentially explosive atmospheres To view this document in PDF format click here.

4) Intrinsic Safety Certification

Instruction manual 640 Securiterre

II 1G EEx ia IIC T4 T a = -20ºC to +60ºC

Dependable Solutions for Gas Detection

Hazardous Area Classifications and Protections

Certification Supplement Manual

ACHIEVING REDUNDANT INTRINSICALLY-SAFE FIELDBUS SEGMENTS FOR FISCO & ENTITY DEVICES

TRASCO ATEX Couplings

Certificate of Compliance

Intrinsically Safe, NEMA 4, Type 4X, IP67 Loop-Powered Meter

Ex Safety and Installation Instructions GS030 Slew sensor Transmitter & GS031 Slew Sensor Encoder

Part I Extraction Process Equipment

Rosemount 752 Fieldbus Remote Indicator

WHAT WHITE PAPER IS POTENTIALLY EXPLOSIVE ATMOSPHERE CERTIFICATION AND WHY YOU. June 2010

Intrinsic Safety. Intrinsically Safe Solutions. Accurate Weighing in Hazardous Areas

HOW TO FIND THE RIGHT DEVICE FOR YOUR FACILITY

ANNEX GD-CERT-EX-EN SIT

Matters Needing Attention of Electrical Equipment Installation Engineering in Hazardous Areas. Wang Qiaoli

AlarmLine Linear Heat Detector

Rosemount 3490 Series 4 20 ma + HART Compatible Controller

The R. STAHL Technology Group Worldwide Success with Competence and Customer Support

Certificate of Compliance

Hazardous Area Classification in Oil & Gas Industry. A Fire Prevention Tool

Products Solutions Services CT287. Hazardous Area Classifications and Protection Systems

Introduction to Hazardous Electrical Location Classifications

OPTIBAR DP 7060 Supplementary Instructions

Certificate of Conformity

Selecting a Safe Tank Gauging Product. Understanding Hazardous Area Definitions for Equipment Approvals

SCHMIDT Flow Sensor SS Ex - Supplementary instructions for use in explosive atmospheres ATEX

RE: USE OF FIREPRO IN POTENTIALLY EXPLOSIVE ATMOSPHERES

SET Installation and Operating Instructions. Level switch for one sensor

IECEx Certificate of Conformity

ATEX, NOMENCLATURE AND CODING

Page 1 Copyright by the Fieldbus Foundation All rights reserved.

Battery Powered Separator Alarm Type Standalone Unit. Installation, Operation & Maintenance

Overview of Hazardous Locations as They Relate to Solenoid Valves

Fire Alarm System Accessories

Product Bulletin. VeriSafe Absence of Voltage Tester. The Safe Way to Verify the Absence of Voltage.

Building Services Brochure

OilSET Installation and Operating Instructions. Oil Separator Alarm Device

Installing Foundation Fieldbus in Hazardous Areas. Understanding your Options and How to Use Them

CA 134. Piezoelectric accelerometer. IECEx NEPSI TIIS KGS. » From the Vibro-Meter product line» Vibration monitoring over a wide temperature

ATEX Explained A brief Introduction

Dual certification! Air handling units for potentially explosive atmospheres

Certificate of Compliance

Rosemount 702 Wireless Discrete Transmitter

Tank Gauging System Special Safety Instruction

Junction boxes control boxes THU 93.1 THU 93.6 THU 94.1 THU 94.9 PTB 98 ATEX March 1999

Duct heaters for ATEX/IECEx hazardous areas or in non-atex version

Guidelines for Market Surveillance of Equipment for Explosive Environments (Hazardous Locations)

Gas ventilation monitoring and control system

Certification Supplement Manual

Compliance with EN : 2006 Electrical apparatus for explosive atmospheres Type of Protection «n» for Zone 2

Certificate of Compliance

Guide to Hazardous Location Approvals:

Transcription:

SUMMARY Intrinsically Safe or Explosionproof? Understanding the technology The phrase Intrinsically Safe is often used generically to describe products destined for hazardous (explosive) areas. This paper explores the term Intrinsically Safe, provides an overview of what is required to certify a product and compares Intrinsic Safety against Explosion Protection concepts. Intrinsic Safety the basics The term Intrinsically Safe (I.S.) is frequently used to describe any product destined for an explosive area. In reality, I.S. is a protection concept based around limiting the available electrical energy to nonincendive levels so that sparks cannot occur from short circuit or failures which could cause an explosive atmosphere to ignite. A typical fixed I.S. circuit would comprise a device such as a temperature sensor permanently located within the explosive area, which is in turn protected by a safety barrier located in the safe area. These barriers usually incorporate a series of diodes, resistors and fuses arranged and sized in such a manner that they limit the energy provided to the device in the field. Interestingly, the inclusion of a barrier in the control loop does not allow any device to be connected downstream. Even though the power may be limited, the device located within the explosive area itself must also be designed to comply with the requirements of various regulatory standards depending upon the geographical locale of the plant. Certification standards Across the world, there are differing regulations and requirements which dictate how products are designed, developed, certified and manufactured in order to be sold to a customer as I.S. certified. Some examples of I.S. standards are: Europe:- EN60079-1:2007 United States:- Factory Mutual - FM3610 Canada:- CSA C22.2 NO 157.92-CAN/CSA Although each of these standards defines the requirements for a device to be certified as I.S., the requirements of each are different. These differences range from the effects of static build-up on non-metallic casings to the assessment of cells, even the test parameters themselves may be different. The bottom line is that it is not possible to claim a product certified as intrinsically safe in Europe to EN60079-XX (ATEX) can be deemed as intrinsically safe certified in the United States or Canada and vice versa. For each country, the device should be tested in accordance with the local requirements. Once tested and certified, products are marked as part of their manufacture.

U.S. and Canadian Standards Class I, Division 1, Groups A, B, C, D; Class II, Groups E, F, G; Class III CSA C & US Mark: United States and Canada Safety Standards An electrical, mechanical or electro-mechanical product bearing the North American CSA Listing mark signified that it was tested and meets the minimum requirements of prescribed safety standards. Moreover, the mark indicates that the manufacturer s production site conforms to a range of compliance measures and is subject to periodic follow-up inspections to verify continued compliance. A CSA Listed device with both US and C labels at the lower left and lower right of the CSA mark respectively, signifies that the product bearing the mark complies with both U.S. and Canadian product safety standards. United Kingdom and Europe Zone 0, 1, 2; Group IIC, IIB, IIA, I The Ex Hexagon mark: United Kingdom and Europe Safety Standards Intrinsically safe devices covered by the ATEX Directive can be separated into two distinct options notably Ex ia and Ex ib devices. Devices with the former designation are designed to be safe even after a second order failure of the safety system and are suitable for use in Zone 0 hazardous (explosive) areas. Ex ib devices are designed to operate after a first order failure and as such are suitable for Zone 1 hazardous (explosive) areas. Similar to the CSA mark described above, a product bearing the Ex Hexagon has not only been designed and tested to meet the minimum requirements of the relevant ATEX safety standard but also the production facility has sufficient controls to ensure safe manufacture of the device itself. Annual audits are carried out by safety bodies to ensure that these standards are being adhered to and products designed are safe. Exceptions As with any rule, there are of course, exceptions! Let s assume that we have plant located in the United States comprising of a Class 1 Div I (B) hazardous (explosive) area. We need to take photographs within that area to document equipment during normal operation. Ideally, the device used should have been certified to the local standard which defines the requirements for safety. However, what if no such device exists? What are our options? Option 1: Use a standard off-the-shelf digital camera. This can be done, but requires significant time and effort to raise hot-work permits, risk assessments and method statements plus supplementary safety equipment such as gas detectors to use the camera. Option 2: Attempt to obtain a device that holds a certification similar or greater than that of the hazardous area. For example, an ATEX certified digital camera has been tested for use in explosive areas; these tests were performed to European standards but the safety features of this device obviously exceed those of an off-the-shelf camera. Our plant safety officer would need to assess the camera and its certification along with the task required of it to determine acceptability but this is normally a one-time task rather than raising permits for every trip following Option 1.

Explosionproof technology why use it?? Okay, so I.S. equipment is usually light, compact and robust, everything we need for a portable device. So, why would anyone want to use explosionproof (XP) as a protection concept? The answer is simple: power. With an I.S. system the entire power of the system - which includes but is not limited to the batteries is controlled. This means that inductive and capacitive loads are also assessed to the extent that they cannot cause a spark. These limitations can cause problems when a device needs to operate in a power range higher than allowed. High Voltage Switchgear for example could never be considered I.S. as the power in the conductors is far higher than that accepted by the I.S. standard. Similarly, high energy components such as a camera flash cannot be part of an I.S. device as the flash itself is powered by a capacitor which has a discharge greater than accepted. By using XP as a protection concept, high power devices can be used safely in an explosive area. The XP device itself is designed and tested to contain any explosion which may occur within, protecting the operator and the facility from harm. Design requirements XP devices From a basic design standpoint, an explosionproof device must be able to withstand an explosion within the enclosure and allow escaping gas to cool as it expands and passes through the flamepaths transiting from inside the enclosure to the environment outside. These flamepaths are carefully calculated and manufactured to extreme tolerances in order to achieve the desired cooling effect. XP devices must be serviced by qualified personnel with appropriate tools. If any flamepaths are disturbed then they need to be rechecked in accordance with the certificate, using calibrated devices. Additional requirements for XP may include material selection for device casings. Some materials are specifically prohibited within explosive areas magnesium for example and even common materials such as aluminium must have a metallurgical makeup within a specific range. Polymers are generally not used for XP devices as the requirements for material selection, in addition to anti-static properties, are extremely difficult to achieve. TIP:- Did you know that a nylon camera neck strap may not acceptable within an explosive area? The static charge built up may be sufficient to cause a spark. Due to the higher power of XP devices and their inherent safety with respect to containing any explosion, an XP device is generally heavier that an IS device. However, the additional functionality provided by using the XP protection concept means that the operator can complete tasks otherwise difficult, if not impossible, with IS. A good example would be a camera flash. Using an I.S. digital camera in low light situations would mean that the imagery would be extremely poor by virtue of no flash. To achieve good imagery in this environment, a high energy flash is needed and the only way to achieve this functionality is to use the XP protection concept.

Static discharge shocking! A major design requirement for European certified (ATEX) devices is to select and test any non-metallic enclosure part for its ability to dissipate electrical energy and hence be termed anti-static. This is known as surface resistivity testing and is a major part of any product design. Often overlooked in favour of the electric-mechanical part of an hazardous area system, the anti-static properties of polymer bodies is a huge contributing factor to any device operating in a hazardous area defined by the ATEX Directive in particular. Even mechanical or clockwork devices which may have no electrical components must still be assessed with respect to the effects of static electricity. Usually, enclosure materials are selected with a high carbon content in order to satisfy the requirement of the test standard. However, it is important to note that even though a material manufacturer may state that a product complies with or is compliant to a particular requirement, the certification body may require a representative sample testing in order for it to be acceptable. Quality control So, we have established the design parameters, created a product and had it certified. We can now start selling it, right? Unfortunately, not! As described earlier in this paper, the major challenge with the creation of any explosive area device is the Quality Control associated with its manufacture. As a safety-related device, the control and repeatability of manufacture is paramount. For ATEX certified equipment, separate Quality Assurance Notification (QAN) is required in order for the device to be legally sold. This is different from a standard ISO9001:2000 Quality Management System and far more stringent with respect to inspection, testing and acceptance. For CSA Certified devices, additional Quality Control is needed, as are additional audits. This is the case even if the manufacturer already manufactures ATEX equipment, and vice versa. As a manufacturer adds certification marks to the device, the requirement for additional quality control and subsequent third party audits also increases. Typically, for devices certified for use in the United States or Canada, these audit frequencies are once per quarter, For European ATEX certified products, the audit is generally on a annual basis. Comparing I.S. with X.P. is also necessary when it comes to Quality Control. A manufacturer of I.S. equipment cannot automatically manufacture X.P. equipment and vice versa. Before the device maybe manufactured, Quality Assurance Notification for each applicable certification must also be upgraded, audited and certified.

I.S. Vs X.P. which is best? The answer to this question is obviously a subjective one. There are pros and cons for each protection concept that will dictate the route a manufacturer would take to design, certify and manufacture an instrument. If a device requires a significant amount of power to operate then X.P. must be used. If the construction of a device cannot be controlled to a component level then X.P. must be used. For any non-metallic enclosure materials, anti-static materials must be used, regardless whether the protection concept is I.S. or X.P. I.S. can be used only for very low power applications. Construction of metallic parts must follow the correct metallurgical breakdown as defined by the governing standard, regardless of protection concept. From an ATEX classification standpoint, I.S. and X.P. do differ. ATEX has two types of I.S. certification namely; Ex ia and Ex ib. Both certifications are termed I.S. but they have differing end-use applications. Ex ia may be used in a Zone 0, Zone 1 or Zone 2 explosive area where Ex ib may only be used in Zone 1 or Zone 2 explosive area. In layman s terms, this means that Ex ia has an increased safety aspect with respect to redundancy and as such the device may be used in enclosed spaces where gas or dust is likely to be present at all times. Ex ib may be used in open areas where explosive gas or dust may be present only under certain circumstances. Conversely, Ex d equipment (explosionproof) are allowed to enter Zone 1 or Zone 2 explosive areas, which form the majority of applications for portable equipment. For explosive areas regulated by Classes and Divisions, both X.P. and I.S. maybe used, however as stated earlier in this paper, even though a device is termed I.S. and certified to ATEX does not mean that its I.S. certification is sufficient for U.S. classes and divisions. This differential is the same for products designed as X.P. although the difference itself is less pronounced. When an XP device is tested for compliance with ATEX for Europe, the flamepath gap is 100% larger than required for U.S. certification. Specifically, for Gas Group B the maximum gap for the U.S. is 0.05mm whereas the maximum gap for equivalent Gas Group in Europe is 0.1mm. This means that if the device has already been tested and certified as X.P. for Europe, the size of the openings is much greater and as such the gas has less time to cool, resulting in a product engineered to a higher degree of safety than is required in the U.S. A major difference in the requirements of Europe and North American certifications is the mix of gases used to create the sample explosion during testing. This different gas-mix results in a different set of pressure parameters - in particular where pressure piling is concerned.

Conclusions The explosive area equipment market is closely regulated by certification and government requirements. Each and every explosive area has a cost of ownership which includes the devices used to allow the process to continue must, wherever possible, be tested and certified for the task and area they are destined for. This paper concludes as follows: The choice to select I.S. or X.P. devices must be based on the functionality of the device itself and the area the device is intended to operate. Although a device has been certified as I.S. to ATEX, it cannot be deemed I.S. against U.S. or Canadian Standards. X.P. is the best solution for devices offering high energy functionality. An end user should always select the correctly certified product for the area, if this is not possible then the closest alternative should be used with acceptance from plant safety. If an uncertified product is to be used in an explosive area, then all of the aspects of that product should be assessed including electrical energy, mechanical energy and static energy. Wherever possible, use equipment designed and certified for your specific hazardous (explosive) area. CorDEX instruments Ltd. is the leader in digital imaging for hazardous (explosive) areas. With world firsts including explosionproof digital cameras with high resolution (5MP) arrays and onboard strobe flash, CorDEX Instruments are the perfect choice for your explosive area photography needs. For more information on CorDEX Instruments or to request a demonstration, please email: janet.long@cord-ex.com or visit www.cordexinstruments.com CorDEX Instruments Ltd. No. 6 Farfield Main Road Wykeham Scarborough YO13 9QD Tel. 0044 (0) 1904 749020 Email. sales@cord-ex.com Web. www.cordexinstruments.com