Operation & Maintenance Manual

Similar documents
CLASSROOM UNIT VENTILATORS WITH SPLIT SYSTEM DX AIR CONDITIONING OR CHILLED WATER COOLING MODELS VUD, VDF, VUF AND HCD 2 THROUGH 5 TONS CAPACITY

HVAC EQUIPMENT. Exceptional Single Zone Heating and Cooling Solutions. Product Application Guide

USERS INFORMATION MANUAL

WMWLB / WMWFM / WTWLB / WTWFM Series Hydronic Heating Unit

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise VAV Terminal Units Full Spec. Prepared by: Phone Number: Prepared for:

INSTALLATION INSTRUCTIONS

SSL / SBS Sales Guide BLOWER-COILS REDUCED-FOOTPRINT, VERTICAL

Submittal. RBVR Vertical Concealed Floor Mount FCU RBVR

Operation Manual SCT14B and SCT18B. Inspection. 3 General Description. 3 General Requirements. 3 Standard Features.

Hood Depot Internatioonal, Inc., Phone S. Powerline Road, Deerfield Beach, FL

A. Base Bid: 1. Heating Contractor provide: a. Control sequences for HVAC systems, subsystems, and equipment.

PDF Created with deskpdf PDF Writer - Trial ::

The ultimate fresh air solution.

Flexible & Innovative. Cooling Solutions

Mission Critical. Series 6, 8 & 9. vertical floor mount Ton Units. Air Conditioning Systems

CELDEK Evaporative Cooler Module Installation, Operation, and Maintenance Manual. CELDEK Evaporative Cooler

MODELS B1PA024, 030 AND 036

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

Greenheck Coils. A Complete Line of Custom Coils to Meet Your Needs. 3/8, 1/2 and 5/8 inch OD Tubing

Modular Supply Make-Up Air Unit

Technical Development Program COMMERCIAL HVAC SYSTEMS. Water Source Heat Pump Systems PRESENTED BY: Ray Chow. Sales Engineer

Series 6, Vertical Floor-Mount Units

SKYPAK II Heating & Cooling Self Contained Packages

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

Owner s Manual PRINTED IN CANADA 05/2009

Gas-Fired Indoor and Outdoor Duct Furnaces

INSTALLATION & OPERATIONS MANUAL

FCC Fan-Coil Units High-Performance, Vertical

π H-6621 INDUSTRIAL DEHUMIDIFIER WARNINGS SPECIFICATIONS uline.com WATER REMOVAL ELECTRICAL REQUIREMENTS BUILT-IN ELECTRICAL SAFETY

R Series Cooling Modules

RCM Refrigerant Module

POLAR TEMP FARM MORTALITY UNIT OPERATION MANUAL

R Series Cooling Modules

VSA/VSB & KSA/KSB Series Air Doors

H3/V3 Series Horizontal and Vertical Indoor Air Handling Units. Engineering Catalog

Important Facts You Should Know About Your Heat Pump (602) or (520)

WKS 4000 SERIES (USA only) --INSTALLATION INSTRUCTIONS--

SWIMMING POOL HEAT PUMP UNIT ECO - series. Installation & Instruction manual

OWNER S MANUAL. Installation Operation Maintenance. Saturn Equipment

CROWN. Boiler Co. Santa-Fe Series. Hydronic Air Handlers INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

Temperature, Humidity, Air Quality and Sound Level The four parameters which define comfort in the classroom.

R Series Cooling Manual

Owners Manual Refrigerated Air Dryer MHT SERIES

HRV Vertical Unit Ventilators

OWNER S Manual PRINTED IN CANADA 10/2009

DOM MODEL SERIAL NUMBER VOLTAGE/HERTZ/PHASE

Owners Manual UA75 TO UA1200 SERIES Refrigerated Air Dryer

CENTRAL, SPLIT SYSTEM REFRIGERATED AIR-CONDITIONING INSPECTION INTERIOR

Condensing Unit Installation and Operating Instructions

Model CAC 500M Media Air Cleaner

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

SKYPAK II, 3 Ton Series, gives you a

INSTALLATION AND OPERATING MANUAL

MANUAL 8/12/05. Model BKP TM 100 INSTALLATION, OPERATION & MAINTENANCE. Commercial High Efficiency Heat Pipe Dehumidifier

FCI500/600/FVI500/FCL/FVL600/FCQ-700 Installation and Maintenance Manual

Scholar III Unit Ventilator

RPI Industries, Inc.

Service Manual Models CPH2 & CPH3

ThermoSaver TM Hot Gas Defrost System

REFRIGERATED DROP-INS (2-6)FT-DI Installation and Operating Manual

INSTALLATION & OPERATION GUIDE

FEATURES AND BENEFITS

C-Series. Unique Solutions for All-Indoor HVAC Projects

INSTALLATION, BALANCING & MAINTENANCE

Operation Manual. Instructions for Installation, Operation & Maintenance. PortaPac 5-, 8 and 10-ton Portable Air Conditioners

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

1.03 RELATED SECTIONS: The following sections contain requirements that relate to this section.

INSTRUCTIONS! DO NOT DISCARD!

A/C-HEATER SYSTEM - MANUAL

Series 6, Vertical Floor-Mount Units

Control Systems. Design & Manufacturing. Eco-Friendly. High Performance

PRODUCT CATALOG BLOWER COILS.

UNIVERSITY OF MISSOURI Heating Ventilating and Air-Conditioning (HVAC) 2016 Q1

EarthLinked HC Series Compressor Unit R-410A Quik-Start Instructions

SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED

InstructIon Manual KrEs EQuIPMEnt stands

T-SERIES Air Conditioner. T50 Model INSTRUCTION MANUAL nvent Rev. F P/N

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

RPI Industries, Inc.

Greensource Residential Water Source Heat Pumps. Simply Smart. i Series: SV Model. boschheatingandcooling.com

BATH FAN / LED LIGHT READ AND SAVE THESE INSTRUCTIONS MODEL GBR100LED-DECOR TABLE OF CONTENTS. Package Contents 2. General Safety Information 3

NEWGATE TECHNOLOGIES, INC.

INSTALLATION AND OPERATING MANUAL

MARSTAIR INDEX. Product Description. Cellarator Units Condensing Units 3-6. Condensing Units - Ducted 7

38ASB/CCARS240~600 (036~060) AIR-COOLED CONDENSING UNIT

Energy Recovery with Cooling and Heating

INSTALLATION and OPERATION INSTRUCTIONS

Service Step by Step Trouble-Shooting Check-List

Ceiling Concealed Fan-Coil Unit

Owner s Manual Refrigerated Compressed Air Dryers Models F-200, 250, 300 & F350

The Creative and Performing Arts High School (CAPA) Pittsburgh, PA 11/11/2002 Andrew Tech Mechanical Option Prof. S. A. Mumma

Quest Dry 105, 155, and 205 Dual

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units

EBAC MODEL CD60 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

OPERATING INSTRUCTIONS SMO112 WARM AIR OIL FIRED FURNACE

RPI Industries, Inc.

UNDERCOUNTER LABORATORY REFRIGERATORS and FREEZERS Installation, Operation and Maintenance Instructions

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

Energy Recovery with Cooling and Heating Model ERCH

Transcription:

Operation & Maintenance Manual VUD, VUF, VDF & HCD Series Unit Ventilator IMPORTANT: Read and save this manual for future reference. This manual is to be left with the equipment owner 2006 TEMSPEC INCORPORATED

Table Of Contents INTRODUCTION About the Unit Ventilator. Nomenclature for non-compressorized Unit Ventilators. TYPICAL UNIT LAYOUT Model VUD 200 Model VUD 600 Model VUD 2000 Model VUF 200 Model VUF 500 Model VDF 200 Model HCD 200 Model HCD 600 OPERATION. 2... 5. 6. 7. 8. 9 Sequence Of Operation....0 Hot Water Circuit.... Refrigeration Circuit.... 2 Electrical Circuit.... Dampers.... Filtration..... MAINTENANCE Servicing the Unit.... Maintenance Schedule.... Changing the Filters.... 5 Cleaning the Evaporator Coil....5 Motors....5 TROUBLESHOOTING Basic Troubleshooting Guidelines....6 REPLACEMENT PARTS Limited Warranty..... 7 Parts Sales........7

ABOUT THE UNIT VENTILATOR INTRODUCTION The Temspec unit ventilator is designed as means for providing heating, cooling and ventilation to the classroom. Our goal is to help create an enhanced learning environment by focusing on the following points when designing our equipment: COOLING, HEATING, HUMIDITY AND VENTILATION CONTROL AIR DISTRIBUTION SOUND ATTENUATION By installing the vertical unit ventilator into the classroom, superior control can be obtained for each room. Because the unit can be ducted, an even distribution of air can be achieved throughout the room. The unit ventilator is constructed with heavy gauge metal and sound absorbing insulation for optimal sound attenuation. By applying sound engineering principles and thorough testing, we ensure the highest quality of performance in our unit ventilators. NOMENCLATURE FOR NON-COMPRESSORIZED UNIT VENTILATORS V UD 200 200 = up to 200 cfm 500 = up to 500 cfm 600 = up to 600 cfm 2000 = up to 2000 cfm UD = Upflow Ducted Unit Ventilator UF = Upflow Freeblow (direct discharge) Unit Ventilator CD= Horizontally Ducted Unit Ventilator DF= Downflow Unit Ventilator V=Vertical Unit H=Horizontal --

TYPICAL LAYOUT Model VUD 200 (Upflow, Ducted Configuration) Duct By 0 H 2 2 9 CW HW 9" 5 7 6 8 2.5" (Split System DX) 2.5" (Hot Water / Chilled Water) 28" FRONT ELEVATION Outdoor Air Return Air. Supply air fan. 2. Hot water coil. Optional electric or steam coil available.. DX cooling coil.. Drain pan. 5. Outdoor air damper. 6. Spring return mixed air damper actuator. 7. Filters. 8. Return air damper. 9. 2 pipe or pipe (hot water coil can be in the reheat position). 0. Ceiling tile.. Top extension (optional). 2. Coil access panel.. Hinged filter access panel.. Heavy duty return air grille. NOTE: The component arrangement shown above may vary slightly from that in the unit ventilator supplied. -2-

TYPICAL LAYOUT Model VUD 600 (Upflow, Ducted Configuration) Duct By 0 H 2 2 9 CW HW 9" 5 7 6 8 2" (Split System DX) 2" (Hot Water / Chilled Water) " FRONT ELEVATION Outdoor Air Return Air. Supply air fan. 2. Hot water coil. Optional electric or steam coil available.. DX cooling coil.. Drain pan. 5. Outdoor air damper. 6. Spring return mixed air damper actuator. 7. Filters. 8. Return air damper. 9. 2 pipe or pipe (hot water coil can be in the reheat position). 0. Ceiling tile.. Top extension (optional). 2. Coil access panel.. Hinged filter access panel.. Heavy duty return air grille. NOTE: The component arrangement shown above may vary slightly from that in the unit ventilator supplied. --

TYPICAL LAYOUT Model VUD 2000 (Upflow, Ducted Configuration) Duct By 0 H 2 2 6 9 HW CW 7 9" 5 8 2" (Split System DX) 2" (Hot Water / Chilled Water) " FRONT ELEVATION Outdoor Air Return Air. Dual supply air fans. 2. DX cooling coil.. Filters.. Spring return mixed air damper actuator. 5. Outdoor air damper. 6. Hot water coil. Optional electric or steam coil available. 7. Drain pan. 8. Return air damper. 9. 2 pipe or pipe (hot water coil can be in the reheat position). 0. Ceiling tile.. Top extension (optional). 2. Coil access panel.. Hinged filter access panel.. Heavy duty return air grille. NOTE: The component arrangement shown above may vary slightly from that in the unit ventilator supplied. --

TYPICAL LAYOUT Model VUF 200 (Upflow, Freeblow Configuration) 9 CW 0 2 HW 9" 5 7 2 6 8 2.5" (Split System DX) 2.5" (Hot Water / Chilled Water) 28" FRONT ELEVATION Outdoor Air Return Air. Hot water coil. Optional electric or steam coil available. 2. DX cooling coil.. Drain pan.. Supply air fan. 5. Outdoor air damper. 6. Spring return mixed air damper actuator. 7. Filters. 8. Return air damper. 9. 2 pipe or pipe (hot water coil can be in the reheat position). 0. Double deflection supply air grille.. Coil access panel. 2. Hinged filter access panel.. Heavy duty return air grille. NOTE: The component arrangement shown above may vary slightly from that in the unit ventilator supplied. -5-

TYPICAL LAYOUT Model VUF 500 (Upflow, Freeblow Configuration) 6 9 HW CW 0 7 2 9" 2 5 8 2" (Split System DX) 2" (Hot Water / Chilled Water) " FRONT ELEVATION Outdoor Air Return Air. DX cooling coil. 2. Dual supply air fans.. Filters.. Spring return mixed air damper actuator. 5. Outdoor air damper. 6. Hot water coil. Optional electric or steam coil available. 7. Drain pan. 8. Return air damper. 9. 2 pipe or pipe (hot water coil can be in the reheat position). 0. Double deflection grilles.. Coil access panel. 2. Hinged filter access panel.. Heavy duty return air grille. NOTE: The component arrangement shown above may vary slightly from that in the unit ventilator supplied. -6-

TYPICAL LAYOUT Model VDF 200 (Downflow Configuration) 0 2 5 6 9" 9 HW 2 CW 7 8 8 2.5" (Split System DX) 2.5" (Hot Water / Chilled Water) 28" FRONT ELEVATION Outdoor Air Return Air. Return Air damper. 2. Outdoor air damper.. Supply air fan.. Hot water coil. Optional electric or steam coil available. 5. Spring return mixed air damper actuator. 6. Filters. 7. Slab type DX cooling coil. 8. Drain pan. 9. 2 pipe or pipe (hot water coil can be in the reheat position). 0. Heavy duty return air grille.. Hinged filter access panel. 2. Coil access panel. NOTE: The component arrangement shown above may vary slightly from that in the unit ventilator supplied. -7-

TYPICAL LAYOUT Model HCD 200 (Horizontal Configuration) Duct By 2 9" 6 8 Duct By 2.5" 5 7 9 Duct By Optional intake location 0" x 2" Opening Suspension Rods By 0 OPTIONAL TOP INTAKE DETAIL 2 0 ISOMETRIC VIEW (shown with left side access panel) 28" Outdoor Air Return Air. Outdoor air damper. 2. Spring return mixed air damper actuator.. Return air damper.. Filters. 5. Heavy duty return air grille or duct collar. 6. Split DX or hot water/chilled water coil (2 pipe or pipe). 7. Drain pan. Drain pan is removable when option for bottom access panels is selected. 8. Hot water coil for spilt system DX or heating only units. Optional steam and electric heater also available. 9. Supply air fan. 0. Mounting brackets ( per unit).. Left or Right side hinged filter access panel. Bottom hinged access panel also available. 2. Left or Right side hinged coil access panel. Bottom hinged access panel also available. NOTE: The component arrangement shown above may vary slightly from that in the unit ventilator supplied. -8-

TYPICAL LAYOUT Model HCD 600 (Horizontal Configuration) Duct By 2 9" 6 8 Duct By 2" 5 7 9 Optional intake location Suspension Rods By Duct By 2" x 0" Opening 0 OPTIONAL TOP INTAKE DETAIL 2 0 ISOMETRIC VIEW (shown with left side access panel) " Outdoor Air Return Air. Outdoor air damper. 2. Spring return mixed air damper actuator.. Return air damper.. Filters. 5. Heavy duty return air grille or duct collar. 6. Split DX or hot water/chilled water coil (2 pipe or pipe). 7. Drain pan. Drain pan is removable when option for bottom access panels is selected. 8. Hot water coil for spilt system DX or heating only units. Optional steam and electric heater also available. 9. Supply air fan. 0. Mounting brackets ( per unit).. Left or Right side hinged filter access panel. Bottom hinged access panel also available. 2. Left or Right side hinged coil access panel. Bottom hinged access panel also available. NOTE: The component arrangement shown above may vary slightly from that in the unit ventilator supplied. -9-

Typical Modes Of Operation OPERATION The following are typical modes of operation for a classroom unit ventilator. Please refer to the manual provided by the controls contractor for a more specific controls sequence.. Unoccupied Condition During the unoccupied heat mode (night set-back) space temperature is maintained by a signal from the thermostat/controller to either the modulating control valve, modulating face and bypass damper actuator or electric coil triac. The powered exhaust damper (if applicable) and the outdoor air damper are fully closed and the return air damper is fully open. The supply air fan operates on call from the thermostat/controller. 2. Occupied Condition The unit ventilator is switched to occupied heat by the thermostat/controller. In this mode a signal is sent from the thermostat/controller to either the modulating control valve, modulating face and bypass damper actuator or electric coil triac to maintain room temperature at set point. The outdoor air damper is held at a minimum position in the heating mode. The supply air fan runs continuously.. Economizer (up to 00% outdoor air) The first stage of cooling is the economizer mode during which all stages of heating are off. The outdoor air and the return air dampers modulate to maintain the room at the economizer set point. If the mixed air falls to a programmed temperature (usually 52 F) the outdoor air damper will modulate towards closed until the mixed air temperature rises again (typically to 55 F). in this free cooling mode the ability of the unit ventilator to provide sufficient cooling is limited only by the outdoor air temperature and the total C.F.M. rating of the unit.. Cooling The unit can be equipped with a split system DX evaporator coil that would work in conjunction with a remote condensing unit (provided by others) or can be equipped with a chilled water coil. The system maintains the set temperature plus 5 F and the cooling is cycled on call from the thermostat/controller. In this mode the outdoor air damper will return to minimum position. During night set-back the mechanical cooling and economizer should be locked out. 5. Freeze Protection For units with a steam or hot water coil, some type of freeze protection is usually implemented. This can be by either a low limit temperature control (autoreset or manual reset) or by using a supply air sensor and programming from the controller. When a mixed air temperature is determined to be too low, then the outdoor air damper will close and the control valve will fully open. In some cases the fan will also shut down until the temperature returns to normal levels. -0-

Hot Water Circuit The following are typical hot water piping schematics for a unit ventilator. Please refer to the unit ventilator shop drawings for a more specific layout. 2-way Control Valve Hot Water / Chilled Water with 2-way Control Balancing Valve Manual Air Vent Isolation Valve MV Return MIXED AIR WATER COIL Supply Strainer Isolation Valve Hot Water / Chilled Water with -way Control -way Control Valve Balancing Valve Manual Air Vent Isolation Valve MV NO NC C Return MIXED AIR WATER COIL Supply Strainer Isolation Valve --

Refrigeration Circuit The following is a typical split system refrigeration circuit. Anti-Ice Control MIXED AIR EVAPORATOR COIL Distributor Metering Device TEMSPEC UNIT VENTILATOR REMOTE CONDENSING UNIT Sight Glass, Moisture Indicator High Limit Cut-Out Pressure Test Port Low Limit Cut-Out OUTDOOR AIR CONDENSER COIL Compressor Crankcase Heater -2-

Electrical Circuit The electrical circuit in the unit ventilator is highly dependent on the controller and sequence that is being utilized. The unit can be supplied with a 5V, 208V, 277V or 60V power. Each unit comes standard with an unfused disconnect. A copy of the electrical schematic can be found folded in a pouch inside of the unit ventilator. Dampers The outdoor air dampers and return air dampers are mechanically linked. As the outdoor air dampers open, the return air dampers close. A spring return damper actuator is connected to a linkage that extends to both sets of dampers. The damper actuator manufacturer can vary. Please refer to the wiring schematic for the damper actuator model type. Powered Exhaust (optional) Internal powered exhaust is an optional feature that is provided with our vertical series unit ventilators. This feature comes with a fan and damper module that is mounted into the return air section of the unit. Control should be setup by the temperature controls contractor to operate as an on/off device as the outdoor air damper opens and closes. Filtration Typically disposable filters are provided in the unit with an extra set shipped loose for when the unit is ready for start-up. Please refer to the shop drawings for specific details on filter construction and thickness. Below are sizes and quantity per unit for the different model types. Model Number Filter Size Quantity Per Unit VUD, VDF, VUF, HCD 200 2 x 20 nominal 2 VUD, HCD 600 2 x 2 nominal 2 VUD 2000, VUF 500 6 x 2 nominal 2 --

MAINTENANCE Servicing The Unit Access to the components is gained by removing the front access panels. Typically the panels are fastened by heavy duty Phillips head screws. When removing the access panel (vertical style units), loosen but do not remove the screws. Carefully store the panel in a place where it will not get damaged. The horizontal style units utilize hinged access panels. CAUTION: Disconnect power before servicing the unit. The filter access panels have a kill switch installed that will shut the supply air fan off once the panel is removed. This will only disconnect the power to the supply air fans. Be sure to disconnect ALL power by turning the remote disconnect switch to the off position. Maintenance Schedule Frequency maintenance greatly depends on the surrounding conditions (inside and outside of the building). The following is a typical maintenance schedule for a classroom unit ventilator. Every months Every 2 months Every 2 months Change filters Vacuum out drain pans Clean strainer in hydronic circuit (if applicable) Clean evaporator coil Vacuum any loose debris from interior of the unit Inspect dampers to ensure that there is a proper seal when closed --

Changing the Filters The outdoor and indoor conditions will determine the frequency of filter changes. Temspec recommends that the filters be changed every months as a rule-of-thumb. Note that dirty filters will affect the overall performance of the unit. To change the filters, open / remove the filter access panel by loosening the Phillips head screws. Unclip the filters and replace. Cleaning the Evaporator Coil To clean the evaporator coil, purchase a suitable evaporator coil cleaning solution such as those offered by NU-CALGON (www.nucalgon.com). Follow the manufacturers instructions for use. Note: Chlorine based or anti-fungal pucks or socks are acceptable when placed in the evaporator drain pan. Be sure to vacuum the drain pan during the cleaning process. If the filters are regularly changed, the heating coils do not require cleaning. WARNING: Do NOT use chlorine based cleaners or anti-fungal treatments on the aluminum fins of coil. Motors Temspec provides motors that are permanently lubricated. No maintenance is required. -5-

TROUBLESHOOTING Basic Trouble Shooting Guidelines Problem Supply fan not running Action Required Verify that the disconnect is in the on position Verify that thermostat / controller is not in unoccupied mode (night set-back) Check the fan relay to see if it energizing and deenergizing properly Check to see if the 2V transformer is defective Ensure that wire connections are secured properly Check to see if motor is burned out Compressor shot cycles Ensure that there are no obstructions which would cause the unit to cut-out on high head pressure Check refrigerant level. If the level is to low, the unit will cut-out on low pressure. The Refrigerant type and amount is posted on the metallized CSA label located on the fan housing. -6-

Limited Warranty REPLACEMENT PARTS TEMSPEC INCORPORATED warrants the equipment from factory defects in material or workmanship for a period of one year. For this warranty to be valid, the unit(s) must be installed and maintained in accordance with the manufacturer s printed instructions. It does not cover parts damaged by vandalism, improper installation, maintenance or abuse. Should any replacement parts be required within the warranty period, they will be supplied at no charge, freight prepaid to the jobsite. The cost of labor or incidental expenses incurred in the repair or replacement of parts does not form part of this warranty. The warranty period commences from the date of shipment, except when otherwise agreed at the point of sale (see specific warranty terms and conditions for details). Parts Sales Contact the factory at: -888-TEMSPEC or (905) 670-595 sales@temspec.com Ask for parts sales Be sure to provide the unit serial number which is located on the metalized CSA label, on the fan housing, inside the units. -7-