Installation & Operation

Similar documents
AT-G-SENSE Gas Sensing System

MGS Murco Gas Sensor EC / SC model Gas Detector and Transmitter. Installation & Operation* 08 ASH (1)

MGD - Murco Gas detector / Monitor. Installation & Operation* 08 ASH (1)

MGD Murco Gas Detector. Check / Calibration Procedure* 10 ASH (1)

AT-G-SENSE Gas Sensing System

Integrated Area Monitor and Optional 16-Channel Controller Installation and Operation Manual Instruction Rev 1 March 2014

DGS - Danfoss Gas Sensor Check / Calibration Procedure

AT-G-DETECT Gas Sensing System

ST-IAM Sensor Transmitter Integrated Area Monitor. Check / Calibration Procedure* 10 ASH (1)

Leak Monitors. Installation & Operation* 1- Installation Instructions. 2- Location Instructions. 3- Typical Settings. 4- Operating Instructions

UPON COMMENCMENT OF INSTALLATION IT IS OF PARAMOUNT IMPORTANCE THAT THE STEP BY STEP GUIDE (INCLUDED) IS FOLLOWED COMPLETELY

AquiTron DATA S HEET. AT-GU Commercial Refrigerant Sensor

Danfoss Gas Sensor DGS MODBUS

Gas Detector. Installation and Operation Manual Instruction Revision 3 August Product Leadership Training Service Reliability

Salamander User Guide

VGPS-evo V3.3. Installation Instructions. The VGPS-evo is a gas pressure proving system with ventilation interlock and optional CO2 detection.

Four Channel Gas Detection System AGDS 4. The Home of Control & Automation in Ireland

PRODUCT INSTRUCTIONS. Fire Door Control Panel (FDCP) Stock Code Description Doc No: PI-115. Ellard Fire Door Control Panel Ellard Slave Repeater Unit

Sigma. K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels. Operation and Maintenance Manual. Man-1048 Issue 05 October 2009

GPPS-evo V3.3. Installation Instructions

Please read this sheet as it contains important information

Gas Safety Products. Installation, operating and maintenance 09/05/2016. Merlin CT1650+ Gas Interlock System. S&S Northern Ltd 1

DWYER INSTRUMENTS, INC. P.O. BOX 373 MICHIGAN CITY, INDIANA 46360, U.S.A. Series 670 Hood Monitor. Bulletin AV-670

Intelligent Security & Fire Ltd

Pioneer-R16 Gas Monitor Operator s Manual

HALOGUARD TM IR MONITOR (OPTIONAL) FOUR or EIGHT POINT SCANNER INSTRUCTION MANUAL

INTELLIGENT FIRE TECHNOLOGY. Twinflex and Multipoint V3. User Guide (TO BE RETAINED BY USER) Issue 3

Motorised Infrared Optical Beam Smoke Detector. User Guide

Honeywell ENERGY SAVINGS KIT

GLD-30 Gas Leak Detector

Motorised Infrared Optical Beam Smoke Detector. User Guide

Ax60+ Multi-Gas. Service Manual

Revision November 2013 JVA Technologies. Ethernet General Purpose IO Technical Manual

SECURIT 700L PLUS ENGINEERING MANUAL

Analog Room Pressure Monitor RPC Series

Owner s Manual RD432-0 Chemical Controller

Multi Channel Gas Detection System AGDS MC. The Home of Control & Automation in Ireland

ZSC100 Gas Detection and Alarm System Controller

Product Data Sheet. Merlin GDP2. Gas Safety Products. Merlin GDP2. Installation, operating and maintenance 23/08/2016. S&S Northern Ltd 1

LKD USER MANUAL. Detection and indication of refrigerant leaks MANAGEMENT AND MONITORING

GL-CO-RFG Channel Gas Leak Alarm System

HALOGUARD IR MULTI-POINT, COMPOUND SPECIFIC MONITOR INSTRUCTION MANUAL

20 Light Remote Annunciator

Pre-March 2016 Design - Click to be redirected to newer SBS-H2 design SBS-H2. Hydrogen Gas Detector Kit

Installation Instructions

M770 ph Controller Owner s Manual

Control Panel User Guide

STATUS ALARM ALARM HISTORY POWER HISTORY RESET

SERVICE MANUAL. Ecoboiler Model range: T20 ( ) T30 ( )

MAINTENANCE & TROUBLESHOOTING GUIDE LEAK ALARM CHANNEL DRY OIL WATER AUX ALARM HIGH LOW CRITICAL WATER TANK LEVEL ALARM MODEL LDE-740 ADVANCE PAPER

UNDERCOUNTER SERVICE MANUAL. Ecoboiler UC4L 2.4kW Ecoboiler UC10L 2.8kW Ecoboiler UC10L 5.6kW Ecosmart UC4L 2.

Installation Instructions. The SEC-L is a gas pressure proving system with water and electric isolation, gas detection and ventilation interlock.

HALOGUARD TM II/IR MULTI-GAS MULTI-SENSOR MONITOR INSTRUCTION MANUAL

! "! # Please read these installation and operating instructions completely and carefully before starting.

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

PTE0705 Electric Fence Monitor

Ethernet General Purpose

CellarSafe. Carbon Dioxide and Oxygen Safety Monitor

Danfoss Gas Sensor Type DGS-SC and DGS-IR with MODBUS

INSTALLATION AND OPERATING INSTRUCTIONS

Gas Safety Products. Installation, operating and maintenance. Merlin 1000VW+ Gas Interlock, Gas Proving, Electric & Water Isolation System

BX444-Mc Gas Detector

Smoke Vent Control Panel PCB4 V4 Installation Manual

NZ 400 AUTOMATIC FIRE ALARM SYSTEM OPERATORS MANUAL

SENSA MRE DDM MR

Ecoboiler T20 & T30 SERVICE MANUAL. Marco Beverage Systems Ltd. 63d Heather Road, Sandyford Industrial Estate, Dublin 18, Republic of Ireland

GS100M Gas Detection Controller

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

GMA 301. Operation Manual. Worldwide Supplier of Safety Solutions. Part Number

TECHNICAL INSTRUCTIONS

CPS-1 USER S MANUAL AIR INLET / CURTAIN CONTROL

Premier Hazard STC Instructions

CONTROLS INSTRUCTIONS MANUAL ENGLISH

FIRERAY 5000 range USER GUIDE

Murco Core Product Guide Gas Leak Detection Solutions for all your building needs

Carbon Monoxide (CO) Detecting Ventilation Fan Controller Model 120VC Single Relay (100/25 PPM) (200/35 PPM)

Operation - the PIR internal movement sensor. Operation - the tilt sensor. Operation - awning light. Operation - marker / tail lights

STERLING 10 Control Panel with Remote Keypads ICON and LCD INSTALLATION MANUAL

WARNING Important Safety Information

E N G L I S H FIRE ALARM ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE STAND-ALONE FAAST LT MODELS FL0111E FL0112E FL0122E. 367 mm.

tcm100, tcm101 Series Temperature Control Modules and PTS100, PTS100/3 Pipe Temperature Sensors Operations Manual

Instruction Manual Model L2 RF Switch

Operating instructions Page 12

STATUS ALARM ALARM HISTORY POWER HISTORY RESET

Hydrosense. Vimpex Limited. Star Lane. Great Wakering. Essex SS3 0PJ. Tel: +44 (0) Fax +44 (0)

Carbon Monoxide Transmitter

ANNUNCIATOR FIXED MODULE

Carbon Monoxide (CO) Detecting Ventilation Fan Controller Model COSTAR 24VC-e Single Relay

CA5000 Liquid CO 2 Freezer Backup System

INTRUDER ALARM FOR BUSINESS SECURITY

Pakton Technologies Pty Ltd ABN Ferrier Road, Narangba Qld 4504

Alarm Tone Generator Model AG17

Model OEM-2 INSTRUCTIONS FOR USE

Freightliner Refrigerator Troubleshooting Guide For (TJ18F) (TJ22F) (TJ18FP3)

HA-263K HA-263D. OWNER'S MANUAL Installation And Operation 8-ZONE ALARM CONTROL PANEL FOR HOME AND OFFICE PROTECTIONS OPEN THE CABINET FOR SERVICE

PRODUCT DATA AND INSTALLATION SHEET MWS5-SA STAND ALONE MINIATURE CEILING MOUNTED MICROWAVE PRESENCE DETECTOR

INSTRUCTION MANUAL & 8200 Monitor. Manual Issue 06

The most user friendly Security Alarm System L S Section 1 Overview of System Section 2 Planning your Installation

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

Transcription:

Integrated Area Monitor IAM Integrated Area Monitor Control Panel IAM-C Installation & Operation Content Page 1- IAM Sensor -Installation Instructions 2 2- IAM Sensor -Location Instructions 2 3- IAM Sensor -Typical Settings 2 4- IAM Sensor Installation and Wiring Diagram 3 5- IAM-C control panel -Installation and Wiring Diagram 4 6- IAM Sensor -Operating Instructions 5 7- IAM Sensor Test/Function Instructions 5 8- IAM Sensor -Annual Calibration test 6 9- IAM Sensor Remote sensor head installation 6 10- Agree Selectable functions with end-users 7 11- IAM Sensor Troubleshooting 8 12- IAM-C Panel Operating Instructions 8 Feb 07 (9) Murco Ltd. 45 Sandycove Road. Sandycove. Co Dublin. Ireland. e-mail: info@murco.ie web: www.murco.ie

1- IAM Sensor - Installation Instructions Open the IAM by undoing the two screws. Remove metal faceplate, turn over, and check connection terminals (maximum wire size into terminal block 2.5mm). See diagram on page 3 and then: 1. Connect the output to the remote IAM-C Control Panel at CN6 using two-wire cable (7/0.2mm Alarm Cable up to 500m) It does not matter which wire goes into which terminal. If stand alone IAM please ignore. 2. Relay Outputs connect to NO or NC as required for one or both relays at positions CN4 and CN5. Relays are rated at 24 V d.c /120 V a.c 1A Max (connector block max wire size 2.5mm) 3. Set relay delays using jumpers on header HD1 at position 1 & 2, factory default setting is 0 minutes. 4. Set Latch using jumper on header HD1 at position 3. Factory default is Automatic. 5. Set Sounder condition using jumpers on header HD1 at position 4. Factory default is Enabled. 6. Set remote reset facility using jumper on HD1 at position 5. Factory default is Enabled. 7. Connect mains 230V LNE to terminal CN3 labeled LEN (connector block max wire size is 2.5mm) 2- IAM Sensor - Location Instructions EN378 states that detectors used to ensure safety shall have their sensors located in such positions that they monitor the concentration at heights of the occupants of a human occupied space taking into account the characteristics of the refrigerant used e.g. at less than bed height with heavier than air gases in a hotel room. It also states that ceiling voids are regarded as part of the human occupied space CAUTION In a hotel room monitoring in ceiling voids would not strictly comply with EN378 o o o Do s mount in-room sensor at less than the normal heights of the occupants e.g in a hotel room this is less than bed height - between 200-500mm off the floor. away from draughts and heat sources like radiators etc. avoid sources of steam o Don ts Do not mount sensors - under mirrors - at vanity units - in or near bathrooms Mains power to the unit should be switched and fused (3 amp rating is recommended) 3- IAM Sensor - Typical settings Gas: Refrigerant R410A Alarm Set Point: 1% (10.000 ppm) For a particular unit please refer to the gas settings shown on the rating plate. 2

4- IAM Sensor- Installation and Wiring Diagram 3

5- IAM-C panel- Installation and Wiring Diagram 4

6- IAM Sensor - Operating Instructions 1- On powering up it will sense for the presence of gas after an initial warm-up delay of 5 minutes, the green LED will flash at 1 second intervals during the warm-up. Reset button Vent holes 2- In alarm condition: the green LED stays on the red LED will be on the siren operates (if it has not been disabled and after a delay if this option has been selected) the relay output activates (after a delay if this option has been selected) external interface to the Murco IAM-C panel will be turned on. Mute button The mute button on the exterior of the case may be pressed. (This will switch the sounder off if the sounder disable option is not selected) The reset button is accessible via a hole in the front panel, above the green LED, this may be pressed to reset the alarm if the manual reset option is enabled (only effective when the gas has cleared from around the alarm unit, indicated by the red LED turning off). A non-metallic object such as a match or toothpick should be used to operate the reset button. If automatic reset is enabled, the alarm will reset by itself without user intervention. 3- Fault condition: the green LED will be off the red LED will be on external interface to the Murco IAM-C panel will activate and show the fault condition on that panel 7- IAM Sensor Test/Function Instructions The IAM is calibrated in the factory and does not require to be calibrated on installation. On the other hand, after installation the units should be tested following the bump test procedure. For this expose the sensors to test gas (appropriate to the installation) or crack open the valve of a cigarette lighter without igniting it and hold it over the vent holes on the upper side of the IAM. The gas is heavier than air and should fall into the IAM. This very high concentration will force the system into alarm. The red LED will light showing the system is in alarm. The delay will prevent the siren sounding for the preset delay, if delay is set. 5

To test the siren and or relay function, check the delay is set at zero using the header at HD1 Positions 1+ 2 off as shown on the installation diagram and expose to gas as above. You can mute the siren using the mute button. After the gas has cleared and the red LED has gone off you can reset the alarm condition including the relay and siren by using the reset button (this is if manual reset has been selected). Before testing the sensors on site the IAM must have been powered up and allowed to stabilize, preferably overnight. 8- IAM Sensor - Annual Test Test the sensors annually using the above procedure. If the IAM does not go into alarm contact us for recalibration instructions. When testing the sensors ensure the IAM-C Control Panel functions correctly: Red LED Siren (if connected) activates Relays (if connected) activate Reset Operates CAUTION Local regulations may require annual calibration. 9- IAM Sensor Remote sensor head installation If required to match room decoration or you do not wish to surface mount the IAM, we can supply a decorative faceplate with a remote sensor (standard: brushed stainless steel). This is fitted in an electrical back box 44mm deep. 1. Remove the connector from the sensor PCB to feed the cable through the trunking. 2. Immediately refit the connector to the sensor board in the backbox. The IAM and remote sensor must be kept together as they are calibrated together and are a matched pair. 6

CAUTION Do not remove the sensor boards from a number of units at the same time in case they get mixed up. If doing so, label them, or, ensure you check the serial number on the main PCB and the remote sensor PCB are the same when re-installing. 3. If construction / decoration is still going on in the rooms, fit a standard plastic blanking plate immediately you install the sensor in the back box to avoid dust or damage to the in-room sensor. You can fit the SS vented plate when decoration is completed. 10. Agree Selectable functions with end-users: You should agree these important functions with the customer so that the system will operate as he/she requires: 1. Time Delay Response: available on the relays to avoid any false alarms, which is set with jumpers. The default delay is 0 minutes. We suggest that you set to 15 minutes during start up and construction as you may have VOC (volatile organic compounds) fumes, paint etc in the rooms. They can be reset to a lower value later if required. 2. Siren: The units have an internal siren. You can disable this by jumper but the default setting is enabled. The customer may not want alarms sounding in the rooms especially if you are connecting to a remote monitoring system. Check the customer s preference. 3. Reset: In the event of an alarm, you can have the units auto resetting or latched-out requiring manual resetting. The default is automatic reset. If you are connected to a remote monitoring system you may prefer this as being more convenient. However, if you prefer manual reset you would need to enter a room or wherever you have mounted the IAM to reset it after an alarm. If the unit is connected to an IAM-C panel, you can also remotely reset the IAM on alarm if HD1 jumper is enabled. During operation record any low or high-level alarm. Establish the cause or likely cause if no obvious leak or high gas concentration has occurred. Report these occurrences to your supplier or Murco, and we will advise on corrective measures and issue a trouble-shooting guide. 7

11- IAM Sensor Troubleshooting 1- If on first powering up the unit you have a fault condition, replace the unit and return it to us for checking as transport damage may have occurred. 2- If subsequently you develop a fault condition, contact us for instructions and support. 3- If you experience alarms in the absence of a leak, contact us for instructions and support. 12- IAM C panel - Operating Instructions 1- On powering up the green led will flash and will stay on if there are no faults. 2- If there are faults in any sensor on the system the green LED will go off and the red led will light indicating the sensor in fault. The output to a master or upstream panel will activate and show the fault condition also on that panel. 3- Should an alarm occur: the green LED stays on the red LED on the relevant channel comes on the relays operate the siren operates( can be muted by key switch) the output to a master or upstream operates to be indicated there as a fault downstream. 4- If all the red LEDs are blinking approximately every 5 seconds on a master panel then remove the link on Jumper position JP3 as this should be in the disabled position on a master panel. 8