GMS95 GAS $AVER PRODUCT SPECIFICATIONS 95% AFUE. Multi-Position, Single-Stage/Multi-Speed Gas Furnace. Heating Capacity: 46, ,000 BTUH

Similar documents
GMS9/GCS9 SERIES 93% AFUE

GMSS96 / GCSS96 Single-Stage Multi-Speed Gas Furnace

GMSS92 / GCSS92. Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE. Heating Input: 40, ,000 BTU/h

GME8 80% AFUE. Multi-Position, TwinComfort. Heating Input: 60, ,000 BTU/h

GMSS92 / GCSS92. Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE. Heating Input: 40, ,000 BTU/h

GMSS96 / GCSS96. Single-Stage, Multi-Speed Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

GMSS96 / GCSS96. Single-Stage, Multi-Speed Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

80% AFUE. Multi-Position, Dual$aver. Heating Input: 70, ,000 BTU/h

DM80HE. Two-Stage Convertible Multi-Speed ECM Gas Furnace 80% AFUE. Heating Input: 60, ,000 BTU/h

ADSH8. Two-Stage Convertible. Heating Input: 40, ,000 BTU/h

KG6RC Series TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

FG6T(C,L) Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

KG6TE Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

G6RC Series TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama ! WARNING

TECHNICAL SPECIFICATIONS

RG7D 1-Stage Heat Series

For More Information Click Here or Call General Supply M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace

Rheem Classic Series Multi-position Gas Furnaces

MULTI POSITION GAS FURNACE

M3RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

TZ96MDP SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to kw] (All Models 96% A.F.U.E. )

W92P- SERIES Models with Input Rates from 40 to 115 kbtu [11.72 to kw] (92% A.F.U.E. )

GMH95/GCH9 MULTI-POSITION, DUAL$AVER CONVERTIBLE, MULTI-SPEED GAS FURNACE

Ruud Achiever Plus Series Multi-position Gas Furnaces

TECHNICAL SPECIFICATIONS

Multi-Position Gas Furnaces

AEPF. 1½ to 5 Tons. Contents Nomenclature... 2 Product Specifications... 3 Dimensions... 4 Wiring Diagram... 6 Accessories... 7

Rheem Classic Plus Series Two Stage Multi position Gas Furnaces

Upflow/Horizontal Left, Downflow/Horizontal Right Two Stage Condensing Gas-Fired Furnace

Upflow/Horizontal Condensing, Gas-Fired Furnace

Series Two- Stage Multi-position Gas Furnaces. Ruud Achiever Plus. R96T- Series 96% A.F.U.E. * Input Rates from 40 to 115 kbtu [11.72 to 33.

Upflow/Horizontal Condensing, Gas-Fired Furnace XB 90 PUB. NO

Downflow/Horizontal Right Induced Draft Gas Furnace

Ruud Achiever Series Multi position Gas Furnaces

TZ95MSX SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to kw] (All Models 95% A.F.U.E. )

FORM NO. G REV. 4 Supersedes Form No. G Rev. 3

80% Variable Speed, Two Stage Heating Furnace. Cooling Capacity CFM in. w.c. (125 Pa)

VNE GAS FURNACE 2- STAGE VARIABLE SPEED UPFLOW/HORIZONTAL

GKS9 40" 90% Gas Furnaces

MULTI POSITION GAS FURNACE

MERIT SERIES Downflow

Downflow/Horizontal Condensing, Gas-Fired Furnace XB 90 PUB. NO

TECHNICAL GUIDE MODELS: P*DH GAS-FIRED CONDENSING / HIGH EFFICIENCY DOWNFLOW / HORIZONTAL FURNACES 91 AFUE DESCRIPTION WARRANTY FEATURES

GCVC96 (B) Two-Stage, Variable-Speed ECM Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

GAS FURNACES CLASSIC 90 PLUS HIGH EFFICIENCY DOWNFLOW/ HORIZONTAL GAS FURNACES

TZ96MDV SERIES Model with Input Rates from 60 to 100 kbtu [17.58 to kw] (All Models 95% A.F.U.E. )

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH S9V2B080U4-SUB-1-EN. February 2016 S9V2B080U4PSAA TAG:

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 40,000 BTUH S9V2B040U3-SUB-1-EN. February 2016 S9V2B040U3PSAA TAG:

Rheem Classic Plus Series Multi position Gas Furnaces

GAS FURNACES. ACHIEVER SERIES SUPER QUIET 80 80% A.F.U.E. DOWNFLOW GAS FURNACES w/ecm MOTOR

H9MPV. 2- Stage Variable Speed 90. Flexibility. Quality. Comfort. Efficiency. Service (7/2004)

Cooling Capacity CFM in. w.c. (125 Pa)

Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace XR 80

Model GB1AAV UPFLOW GAS FURNACE. Series G SS-GB1A-04 FEATURES

GAS FURNACES SUPER QUIET 80 TWO STAGE 80% A.F.U.E. DOWNFLOW GAS FURNACES

GAS FURNACES SELECT 90 PLUS HIGH EFFICIENCY DOWNFLOW/ HORIZONTAL GAS FURNACES

ACNF Series. Ceiling-Mount Air Handlers 1½ to 2½ Tons

T9MPV. 2- Stage Variable Speed 90. Flexibility. Comfort. Efficiency. Quality. Service (05/2006)

Rheem Prestige Series Communicating Two Stage Variable Speed Multi position. Gas Furnaces

Wt. Lbs Model Number (BTUH) Hz

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH S9V2B080U3-SUB-1-EN. February 2016 S9V2B080U3PSAA TAG:

XC80 TUD2B060ACV32A TUD2B080ACV32A TUD2C080ACV42A TUD2B100ACV32A TUD2C100ACV52A TUD2D120ACV52A TUD2D140ACV52A

Rheem Prestige Series Communicating Two Stage Variable Speed Multi position. Gas Furnaces

Upflow/Horizontal 2-Stage, Communicating Variable Speed Gas Furnace Platinum SV

FORM NO. G REV. 2 Supersedes Form No. G Rev. 1 GAS FURNACES

Upflow/Horizontal Left Downflow/Horizontal Right Condensing, Direct Vent Gas-Fired Furnace FREEDOM 90 SINGLE STAGE

Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace XR 80

90 HIGH EFFICIENCY UPFLOW GAS FURNACES

FEATURES. Gas Furnace provides the efficiency customers want with 78% Annual Fuel Utilization Efficiency (AFUE).

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace

Upflow/ Horizontal Left, Downflow/ Horizontal Right Two Stage Condensing Gas-Fired Furnace XL 90

Rheem Classic Series Downflow/ Horizontal Gas Furnaces

Upflow/Downflow Horizontal Right or Left Gas-Fired Furnace

13 GEP A L P - 1 A

90 HIGH EFFICIENCY DOWNFLOW/ HORIZONTAL GAS FURNACES

90 HIGH EFFICIENCY UPFLOW GAS FURNACES

TECHNICAL MANUAL. AMS8 33-3/8" Gas Furnace Units 80% AFUE, Single Stage, Multi-Speed, Upflow Horizontal

TECHNICAL MANUAL. GMS8 33-3/8" 80% Gas Furnace Units 80% AFUE, Single Stage, Multi-Speed, Upflow Horizontal

Submittal. Downflow Two Stage Condensing Gas Fired Furnace 100,000 BTUH S9V2C100D4-SUB-1-EN. March 2016 S9V2C100D4PSAA TAG:

Cooling Capacity CFM in. w.c. (125 Pa)

FG7T (C and L Series)

GAS FURNACES SILHOUETTE II PLUS 2 LXE TWO STAGE 80% A.F.U.E. UPFLOW/HORIZONTAL GAS FURNACES

Cooling Capacity CFM range

GAS FURNACES CLASSIC 90 PLUS HIGH EFFICIENCY UPFLOW GAS FURNACES

Rheem Prestige Series Communicating Two-Stage Variable Speed Downflow Gas Furnace

Downflow/Horizontal Right or Downflow/Horizontal Left Induced Draft Gas Furnace

GAS FURNACES. Communicating Furnace Thermostat. FORM NO. G Supersedes Form No. G RHC-TST550CMMS MID HIGH

TECHNICAL MANUAL. GMH8 39" 80% Gas Furnace 80% AFUE, 2-Stage (Convertible), Multi-Speed, Upflow/Horizontal

Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace XB 80 TDD-D-1 PUB. NO

80% A.F.U.E. DOWNFLOW GAS FURNACES

Ruud Acheiver Series Upflow Gas Furnaces

TECHNICAL GUIDE MODELS: P*UR GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW FURNACES 92 AFUE DESCRIPTION WARRANTY FEATURES Rev.

90 HIGH EFFICIENCY DOWNFLOW/ HORIZONTAL GAS FURNACES

T9MPV SmartComfort VS90 Product Specifications

GCVC96 (B) Two-Stage, Variable-Speed ECM Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

GMVC96 (B) Two-Stage, Variable-Speed ECM Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

GAS FURNACES. RGRK- SERIES Models with Input Rates 120,000 BTU/HR [35.17 kw] (All Models 90% A.F.U.E. or Above)

Transcription:

GMS95 GAS $AVER 95% AFUE Multi-Position, Single-Stage/Multi-Speed Gas Furnace Heating Capacity: 46,000 115,000 BTUH 95% AFUE s Qualify for a $150 Tax Credit Standard Features Corrosion-resistant, aluminized-steel tubular heat exchanger and stainless-steel recuperative coil Multi-position installation upflow, hor i zon tal right or left Energy-saving, reliable Hot Surface Ignition system, featuring a Norton Mini-Igniter with patented adaptive learning algorithm to maximize igniter life Aluminized-steel inshot burners Energy-saving PSC, multi-speed, direct-drive blower motor Quiet, corrosion-resistant induced draft blower assembly Integrated furnace control with diagnostics Low-voltage terminal block Multiple flame roll-out switches, blower door safety switch, outlet air-limit & pressure switch for proof of combustion air 40VA transformer for heating and air conditioning control service Combination redundant gas valve and regulator Completely assembled, factory run-tested furnace for heating or combination heating/ cooling application Dual-certified for direct vent (2-pipe) or nondirect vent (1-pipe) applications Convenient left or right connection for gas and electric service All models comply with California NOx Standards Cabinet Features Heavy-gauge, reinforced, fully insulated steel cabinet with durable baked-enamel finish Attractive architectural gray paint finish Foil-face insulation-lined heat exchanger compartment Coil and furnace fit flush for easy installation Bottom or side air inlet Removable, solid-bottom block-off Accessories L.P. Conversion Kit L.P. Gas Low Pressure Kit Electronic Air Cleaner (GSAS) Blower Motors Media Air Cleaner (GMU) High-Altitude Natural Gas/L.P. Kits High-Altitude Pressure Switch Kit External Filter Rack Horizontal/ Vertical Concentric Vent Kit Flush-mount Vent Kit Internal Filter Retention Kit upflow, horizontal Thermostats SS-GMS95 www.goodmanmfg.com 10/05

Nomenclature G M S 95 070 3 B X A G: Goodman or Distinctions Air Flow Direction M: Upflow/Horizontal D: Dedicated Downflow C: Downflow/Horizontal H: Hi Air Flow Description S: Single Stage/Multi-speed V: Two-Stage/Variable-speed T: Two-Stage/PSC AFUE 8: 80% 9: 93% 95: 95% KBTUH 045: 45,000 070: 70,000 090: 90,000 115: 115,000 140: 140,000 Maximum CFM @ 0.5 ESP 3: 1,200 4: 1,600 5: 2,000 Cabinet Width A: 14 B: 17½ C: 21 D: 24½ NOx N: Natural Gas X: Low NOx Revision A: Initial Release B: 1 st Revision C: 2 nd Revision 2 SS-GMS95

Specifications Circulator Blower Size (D x W) HP Speed Min. Vent Diameter¹ No. of Burners Filter Size (in 2 ) Permanent Disposable Minimum Circuit Amps 2 Maximum Overcurrent Amps 3 Ship Weight (lbs) GMS950453BXA 10 x 7 1/3 4 2 2 288 576 9.4 15 132 GMS950703BXA 10 x 8 1/3 4 2 3 324 672 9.4 15 135 GMS950704CXA 10 x 10 1/2 4 2 3 384 768 13.8 15 136 GMS950904CXA 10 x 10 1/2 4 2 4 432 864 13.8 15 158 GMS950905DXA 11 x 10 3/4 4 3 4 480 960 13.2 15 172 GMS951155DXA 11 x 10 3/4 4 3 5 486 972 13.2 15 175 ¹ Installer must supply one or two PVC pipes: one for combustion air (optional) and one for the fl ue outlet (required). Vent pipe must be either 2 or 3 in diameter, depending upon furnace input, number of elbows, length of run and installation (1 or 2 pipes). The optional Combustion Air Pipe is dependent on installation/code requirements and must be 2 or 3 diameter PVC. ² Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. ³ Maximum Overcurrent Protection refers to maximum recommended fuse or circuit breaker size. NOTES: All furnaces are manufactured for use on 115 VAC, 60 Hz, single phase electrical supply. Gas Service Connection ½ FPT Important: It is required to size overcurrent protection device and wires properly and make electrical connections in accordance with the National Electrical Code and/or all existing local codes. Performance Ratings Heating Capacity BTUH Tons AC @ Temperature AFUE² Input 1 Output 0.5 ESP Rise Range ( F) GMS950453BXA 46,000 44,600 95.0 3.0 35-65 GMS950703BXA 69,000 66,400 95.0 3.0 30-60 GMS950704CXA 69,000 66,400 95.0 4.0 35-65 GMS950904CXA 92,000 89,000 95.0 4.0 30-60 GMS950905DXA 92,000 88,400 95.0 5.0 35-65 GMS951155DXA 115,000 110,500 95.0 5.0 35-65 ¹ For altitudes above 2,000, reduce input rating 4% for each 1,000 above sea level. ² DOE AFUE based upon Isolated Combustion System (ICS). SS-GMS95 3

GMS95 Dimensions DISCHARGE AIR 28 3/4 3/4 3/4 195/8 7/8 2 1/2 AIR INTAKE PIPE 2" PVC A B (DISCHARGE AIR) C 3/4 2 1/16 VENT/FLUE PIPE 2" PVC DISCHARGE AIR 1 1/2 14 ALTERNATE GAS SUPPLY HOLE 7 3/8 HIGH VOLTAGE ELECTRICAL HOLE LEFT SIDE DRAIN LINE HOLES 23 DRAIN TRAP CL LOW VOLTAGE ELECTRICAL HOLE 1 3/4 SIDE CUT-OUT 1 3/4 30 1/4 2 5/8 21 1/4 19 3/16 11 3/4 40 CONDENSATE DRAIN TRAP w/ 3/4" PVC DISCHARGE (RIGHT OR LEFT SIDE) 2 16 5/8 30 1/4 32 13/16 27 1/8 2 11/16 4 1/8 24 9/16 2 5/8 19 3/16 11 3/4 6 1/8 DRAIN TRAP CL 1 3/4 ALTERNATE AIR INTAKE LOCATION STANDARD GAS SUPPLY HOLE ALTERNATE VENT/FLUE LOCATION HIGH VOLTAGE ELECTRICAL HOLE RIGHT SIDE DRAIN LINE HOLES LOW VOLTAGE ELECTRICAL HOLE SIDE CUT-OUT 1 23 9/16 BOTTOM KNOCK-OUT D BOTTOM KNOCK-OUT LEFT SIDE VIEW FRONT VIEW RIGHT SIDE VIEW A B C D GMS950453BXA GMS950703BXA GMS950704CXA GMS950904CXA GMS950905DXA GMS951155DXA 17½ 16 13⅛ 13⅝ 21 19½ 16⅛ 17½ 24½ 23 20⅝ 20⅞ NOTES: 1. Installer must supply one or two PVC pipes: one for combustion air (optional) and one for the fl ue outlet (required). Vent pipe must be either 2 or 3 in diameter, depending upon furnace input, number of elbows, length of run and installation (1 or 2 pipes). The optional Combustion Air Pipe is dependent on installation/code requirements and must be 2 or 3 diameter PVC. 2. Line voltage wiring can enter through the right or left side of the furnace. Low voltage wiring can enter through the right or left side of furnace. 3. Conversion kits for high altitude natural gas operation are available. Contact your Goodman distributor or dealer for details. 4. Installer must supply following gas line fi ttings, according to which entrance is used: Left Two 90º elbows, one close nipple, straight pipe Right Straight pipe to reach gas valve 4 SS-GMS95

Minimum Clearances to Combustible Materials Position Sides Rear Front Bottom Flue Top Upfl ow 0 0 3 C 0 1 Horizontal 6 0 3 C 0 6 C = If placed on combustible fl oor, the fl oor MUST be wood ONLY. NOTES: For servicing or cleaning, a 36 front clearance is recommended. Unit connections (electrical, fl ue and drain) may necessitate greater clearances than the minimum clearances listed below. In all cases, accessibility clearance must take precedence over clearances from the enclosure where accessibility clearances are greater. SS-GMS95 5

GMS95 Blower Performance Specifications CFM & Temperature Rise vs. External Static Pressure Motor Speed Tons AC at 0.5 ESP External Static Pressure, (Inches Water Column) 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM CFM CFM GMS950453BXA GMS950703BXA GMS950704CXA HIGH 3.0 1352 29 1318 30 1260 31 1202 33 1128 35 1044 955 853 MED 2.5 1214 32 1172 34 1123 35 1064 37 1012 39 938 859 741 MED-LO 2.0 997 40 994 40 960 41 923 43 884 45 817 741 611 LOW 1.5 757 52 753 52 734 54 704 56 674 59 620 524 438 HIGH 3.0 1449 41 1409 42 1326 45 1273 47 1201 49 1194 1136 1018 MED 2.5 1192 50 1172 51 1141 52 1094 54 1046 57 973 904 793 MED-LO 2.0 981 61 962 62 943 63 917 65 888 67 830 764 665 LOW 1.5 750 79 730 81 714 83 692 86 657 90 620 570 502 HIGH 4.0 2069 29 1965 30 1871 32 1756 34 1661 36 1549 1415 1275 MED 3.5 1752 34 1724 34 1667 36 1603 37 1488 40 1402 1290 1082 MED-LO 3.0 1437 41 1437 41 1417 42 1369 43 1320 45 1256 1140 984 LOW 2.5 1184 50 1177 50 1161 51 1132 52 1095 54 1047 928 837 1. CFM in chart is without fi lter(s). Filters do not ship with this furnace, but must be provided by the installer. 2. All furnaces ship as high-speed cooling and medium-speed heating. Installer must adjust blower cooling & heating speed as needed. 3. For most applications, about 400 CFM per ton when cooling is desirable. 4. INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE. 5. The chart is for information only. For satisfactory operation, external static pressure must not exceed value shown on the rating plate. 6. The above chart is for furnaces installed at 0-2000 feet. At higher altitudes, a properly derated unit will have approximately the same temperature rise at a particular CFM, while ESP at the CFM will be lower. 6 SS-GMS95

GMS95 Blower Performance Specifications (cont.) CFM & Temperature Rise vs. External Static Pressure Motor Speed Tons AC at 0.5 ESP External Static Pressure, (Inches Water Column) 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM CFM CFM GMS950904CXA GMS950905DXA GMS951155DXA HIGH 4.0 1970 40 1874 42 1757 45 1667 48 1566 51 1431 1334 1182 MED 3.5 1713 46 1650 48 1572 50 1510 52 1418 56 1313 1211 1079 MED-LO 3.0 1439 55 1412 56 1370 58 1327 60 1260 63 1166 1078 956 LOW 2.5 1183 67 1155 69 1122 71 1108 72 1062 75 1011 931 816 HIGH 5.0 2147 37 2114 37 2057 39 2030 39 1978 40 1889 1784 1713 MED 4.0 1675 47 1686 47 1640 48 1623 49 1557 51 1501 1455 1360 MED-LO 3.5 1489 53 1470 54 1436 55 1409 56 1361 58 1318 1243 1130 LOW 3.0 1307 61 1265 63 1234 64 1203 66 1168 68 1096 1053 991 HIGH 5.0 2134 46 2103 47 2029 48 1941 51 1906 51 1818 1733 1625 MED 4.0 1678 58 1643 60 1643 60 1577 62 1527 64 1489 1423 1339 MED-LO 3.5 1453 68 1440 68 1426 69 1363 72 1349 73 1314 1253 1205 LOW 3.0 1259 78 1239 79 1220 80 1181 83 1159 85 1118 1082 1015 1. CFM in chart is without fi lter(s). Filters do not ship with this furnace, but must be provided by the installer. 2. All furnaces ship as high-speed cooling and medium-speed heating. Installer must adjust blower cooling & heating speed as needed. 3. For most applications, about 400 CFM per ton when cooling is desirable. 4. INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE. 5. The chart is for information only. For satisfactory operation, external static pressure must not exceed value shown on the rating plate. 6. The above chart is for furnaces installed at 0-2000 feet. At higher altitudes, a properly derated unit will have approximately the same temperature rise at a particular CFM, while ESP at the CFM will be lower. SS-GMS95 7

Accessories Description GMS950453BXA GMS950703BXA GMS950704CXA GMS950904CXA GMS950905DXA GMS951155DXA LPT-00A L.P. Conversion Kit LPLP01 L.P. Gas Low Pressure Kit GSAS Electronic Air Cleaners (-10, -11, -12, -18) GMU Media Air Cleaners (1620, 2020, 1625, 2025) HANG11 High Altitude Natural Gas Kit 1 1 1 1 1 1 HANG12 High Altitude Natural Gas Kit 2 2 2 2 2 2 HALP10 High Altitude L.P. Gas Kit 3 3 3 3 3 3 HAPS27 High Altitude Pressure Switch Kit 3 3 3 3 3 3 EFR01 External Filter Rack DCVK-20 Horizontal/Vertical Concentric Vent Kit (2 ) DCVK-30 Horizontal/Vertical Concentric Vent Kit (3 ) 017K00000S Flush-mount Vent Kit Available for this model (1) 7,001 to 9,000 (2) 9,001 to 11,000 (3) 7,001 to 11,000 Note: All installations above 7,000 require a pressure switch change. For installation in Canada, furnaces are certifi ed only to 4,500. Thermostats CHT18-60 CH70TG CHSATG H20TWR Description Cooling/Heating, Mechanical Cooling/Heating, Digital, Non-programmable Cooling/Heating, Mechanical Heating Only, Mechanical Goodman Manufacturing Co., L.P., reserves the right to discontinue, or change at any time, specifications or designs without notice or without incurring obligations. Copyright 2005 Goodman Manufacturing Co, L.P. Houston, Texas Goodman brand products are made proudly in the USA. Printed in the USA. 8 SS-GMS95