DIRECT FIRED HOT WATER BOILER Atmospheric Gas Fired T Models 300,000 to 6,800,000 BTU Gas Fired

Similar documents
GENERAL BASIC INSTALLATION INSTRUCTIONS DIRECT FIRED HOT WATER BOILERS PARKER BOILER CO.

GENERAL BASIC INSTALLATION INSTRUCTIONS INDIRECT GAS FIRED WATER HEATERS PARKER BOILER CO.

Bryan Flexible Water Tube. Ultra-High Efficiency Condensing Hot Water Boilers. 3,000,000 BTUH Natural Gas Fired

SERIES 24. Series 24 Features. Commercial, Forced Draft, Hot Water or Steam Boiler. The right fit for any commercial job

FUEL-FIRED VERTICAL TUBELESS BOILERS

CCLEARFIRE CONDENSING FIRETUBE BOILER DESIGNED FOR MAXIMUM HYDRONIC SYSTEM EFFICIENCY 500 TO 3,300 MBTU

Copper Finned Gas-Fired Volume Water Heaters, Boilers and Commercial Pool Heaters. Low NOx, Quiet, Efficient, Space-Saving

HORIZONTAL FIRE TUBE BOILERS Piping (HVAC) Pumping Equipment (HVAC).

Columbia Boiler Company

Burner Comparisons. Typical Competitor s Burner

PART 0 A/E INSTRUCTIONS 0.01 DESIGN REQUIREMENTS

AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

INTRODUCING THE BRADFORD WHITE 24/7 EXPERT SUPPORT CENTER. TABLE OF CONTENTS. Technical Support: Warranty Support:

Gas and Electric Convection Ovens

Commercial Gas Water Heaters

Cclearfire HIGH EFFICIENCY, COMPACT CONDENSING BOILER 500-3,300 MBTU

MECHANICAL VENTING VERSATILITY

Suggested Specification: Benchmark 1.5 Low NOx Gas-Fired Hydronic Boiler(s)

Fuel-Fired Vertical Tubeless Boilers

G315/5 Cast Iron Boiler

Series 300 VTB. Installation Instructions

A. Section Common Motor Requirements for HVAC Equipment: Fan motors.

Originators of the Flexible Water Tube design

WATER-TUBE POOL HEATERS

WATER HEATERS / BOILERS GWB8-E. Gas-Fired Hot Water Boiler PRODUCT SPECIFICATIONS. AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

DIVISION FINNED WATER-TUBE WATER HEATERS

WATER HEATERS / BOILERS GSB8-E. Gas-Fired Steam Boiler PRODUCT SPECIFICATIONS. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB E

G315/6 Cast Iron Boiler

83.5 % UP TO 95 % 86.5 % High to Mid-Efficiency Residential & Commercial Heating Solutions. Boilers and Indirect Water Heaters

GB Condensing Gas Boiler

DIVISION WALL-HUNG STAINLESS STEEL HEATING BOILERS

High efficiency, cast-iron gas boiler

WATER-TUBE POOL HEATERS

SECTION WATER-TUBE BOILERS

Originators of the Flexible Water Tube design

SECTION HEATING BOILERS

SECTION (15486) - FUEL-FIRED, DOMESTIC WATER HEATERS

G515/7 Cast Iron Boiler

15B Cast Iron Gas Fired Boilers For Forced Hot Water

GB Condensing Gas Boiler

Mascot. Gas-Fired Residential and Commercial Wall-Mounted Boiler. Easy Installation, 96% Efficiency, Fully Condensing

G124X - G234X - G334X Atmospheric Gas Boilers

Originators of the Flexible Water Tube design

G615/11 Cast Iron Boiler

FINNED WATER-TUBE POOL HEATERS

Commercial Gas Water Heaters

XTHERM, TYPE WH - MODELS 1005A- 2005A DIVISION COMMERCIAL, WATER-TUBE, CONDENSING GAS DOMESTIC WATER HEATERS

TMB Baking TSV Gas Oven TAG Series. Contractor s Utility Requirements

Replacement parts EG/PEG

DIVISION FINNED WATER-TUBE WATER HEATERS

Utica Boilers MAC Submittal

DIVISION COMMERCIAL, GRID-TYPE, FINNED-TUBE, GAS DOMESTIC WATER HEATERS

TABLE OF CONTENTS BRADFORD WHITE BOILERS

TGIF-1. Indirect Fired Heating Systems. Technical Guide for: IF Indoor Installations. IFW Outdoor Installations. Applied Air. Keeps You.

GSB8. CONSERVATOR Gas-Fired Steam Boiler. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB S MODEL NUMBER IDENTIFICATION FEATURES

A-8-01 Typical questions and answers on the boiler specifications on tender and boiler contract documents

Boiler & Water Heater

RGE 13 A T - 1 A

84 PROFESSIONAL - IN A CATEGORY ALL ITS OWN

Warm. IFR Indirect Fired Gas Heating Systems. Applied Air. Keeps You

SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER

Bryan Water-Pak Indirect Systems 360,000 BTU to 4,500,000 BTU Inputs 199 to 3,533 Gallons Storage Capacity

BUDERUS. Quality. Versatility. Efficiency. Superior Design. Comfortable. Efficient. Intelligent Heating. Conventional Gas Boilers

AFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh

Industrial Applications

mith Mills 4500A Smith Mills 4500A 4500A-3R OIL, GAS OR COMBINATION GAS/OIL COMMERCIAL BOILER/BURNER CAST IRON

ClearFire - Hydronic Startup Report

LOW NOx, HIGH EFFICIENCY, HOT WATER SUPPLY AND HYDRONIC HEATING BOILERS

SECTION PLUMBING EQUIPMENT

Internet Version for Reference Only INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART #

GB Condensing Gas Boiler

DIVISION FINNED WATER-TUBE BOILERS

RBI MASTERSPEC. A. This Section includes gas-fired, non-condensing finned copper water tube water heaters for heating hot water.

GP COMBUSTION EQUIPMENT INC 100 Sheldon Dr., Units 16/17 Cambridge, Ontario N1R 7S7. Model C Forced Draft Burners. Natural Gas or Propane MODEL C10

AFUE 95% Heating Input 50,000 to 200,000 Btuh

Series 8H. Cast Iron Gas Fired Commercial Water Boiler

VICTORYII. Cast-iron, power vent gas boiler BOILER FOR OLDER HOMES.

DIVISION FINNED WATER-TUBE BOILERS

DIVISION FINNED WATER-TUBE BOILERS

PB HEAT, LLC TRADE PRICE LIST EFFECTIVE JUNE 1, 2018 P-18

Design and Construction Standards SECTION PLUMBING EQUIPMENT

Concrete Applications

PACKAGED COMMERCIAL WATERTUBE BOILERS

TRIAD Boiler Systems, Inc Atlantic Drive, Unit 2 West Chicago, IL

LGB COMMERCIAL GAS BOILER. Versatile combustion control systems. Made with Weil-McLain quality COMMERCIAL GAS BOILER APPLICATIONS INCLUDE:

Section B1. Flexible Watertube Boilers TABLE OF CONTENTS

Product Data BW9 WATER BOILER SERIES B

SUBMITTAL SCHEDULE & DATA

FINNED WATER-TUBE POOL HEATERS

VF/VG700 Jumbo. Construction Heater. Installation and Maintenance Manual

TURBOPOWER. Non-Condensing Gas, Oil or Combination Gas/Oil Storage Water Heater. 199 to 4000 MBH 150 to 4500 Gallons Tanks 25-year Warranty. PVI.

199,000 to 4,000,000 Btu/h 150 to 4500 Gallons Storage

Cast Iron Gas Boiler For Forced Hot Water REPAIR PARTS AND OPTIONAL ACCESSORIES

DIVISION FINNED WATER-TUBE BOILERS

INDOOR/OUTDOOR, HOT WATER HEATERS AND HYDRONIC HEATING BOILERS

Omega II SUBMITTAL DATA. Pre Engineered Packages. Products by: COMBUSTION RESEARCH CORPORATION PROJECT: LOW-INTENSITY INFRARED HEATING SYSTEMS

HHA Bellerive Apartments 7225 Bellerive Houston, Texas J. Allen Management Managing Agent

mith Mills Smith Mills 6500A 6500A-4 OIL OR GAS CAST IRON BOILER/BURNER CAST IRON

NO ONE PUTS MORE INTO THEIR POOL HEATERS

Cast Iron Gas Boiler For Forced Hot Water REPAIR PARTS AND OPTIONAL ACCESSORIES

Transcription:

INDUSTRIAL DIRECT FIRED HOT WATER BOILER Atmospheric Gas Fired T Models 300,000 to 6,800,000 BTU Gas Fired 201 Hot Water Boilers THE PARKER DESIGN A time proven product backed by one of the largest and most successful manufacturers of packaged boilers. The Parker name is synonymous with quality and safety. Every boiler is thoroughly factory fire tested and is required to meet the highest standards in all phases of mechanical and operating efficiency before shipment. Parker Hot Water Boilers are designed specifically to provide the building heating and industrial processing industries with a Superior Quality Boiler with Unequaled Advantages in Safety, Long Life Service and Economical Operation. Direct Fired Hot Water Boiler 300,000 to 6,800,000 BTU Input Temperatures to 400 F Pressures to 300 PSI BENT TUBE CONSTRUCTION The Parker Bent Tube All-Welded construction is the most flexible and durable on the market. 2. Large Heating Surface A large amount of heating surface provides increased efficiency, long boiler life and minimizes chances of scaling. PARKER BOILER CO. 5930 Bandini Boulevard Los Angeles, CA 90040 Tel (323) 727-9800 Fax (323) 722-2848 www.parkerboiler.com BROCHURE 201 0J5 3. Simplicity The Atmospheric Burner System, the control system and entire boiler are furnished so that it is simple to operate by regular personnel. Simplicity is a decided advantage as there are no expensive blowers, complicated controls, or burner adjustments, as is necessary on many boilers. 4. Codes All Parker Hot Water Boilers are manufactured in accordance with the ASME Power & Heating Boiler Codes and registered with the National Board of Boiler and Pressure Vessel Inspectors. The standard natural gas fired model is furnished as an Underwriters Laboratories, Inc. Listed Gas Fired 201 Hot Water Boilers ADVANTAGES 1. Safety A Parker Boiler has never been known to internally explode nor has it been possible to induce an explosion under severe tests. Thermal shocks are readily absorbed without damage due to the unique flexible design and extra heavy steel welded construction. Boiler Assembly and displays their symbol on the nameplate. Outdoor, propane and Low NOx models are ETL listed. Canadian models are C-ETL Listed Industrial and Commercial Gas Fired Packaged Boilers certified to CAN/CGA 1-3.1 and UL 795. "Never a Compromise for Quality or Safety" INDUSTRIAL

DIRECT FIRED HOT WATER BOILER Atmospheric Gas Fired T Models 300,000 to 6,800,000 BTU Gas Fired INDUSTRIAL Parker Atmospheric T Model Staggered tubes provide 10-pass self baffled heating surface for high efficiency. Flexibility designed to permit free expansion and contraction, eliminating warping and leaking. Tubes are 1-5/16 OD Steel, over 1/8" thick, welded to headers with high tensile weld metal. M.R. probe type low water cutoff Safety relief valve Temperature/pressure gauge (backside) Dual high limit and operating control Downcomer leg (most models) Automatic burner controls provide 100% flame safeguard with manual reset, dual electric gas valves and gas pressure regulator. Heavy steel frame for mounting on concrete floor. Inspection opening Efficient Parker T-type up-shot low pressure gas burners provide high combustion efficiency and uniform heat distribution 201 Hot Water Boilers Pilot burner 5. Heavy Welded Flexible Tube Construction The Parker steel tube bundle is 1-5/16 OD, over 1/8" thick heavy duty steel. The welded bent tube design permits free expansion and contraction of each tube independently when subject to thermal shocking. Our design eliminates strain on the metal, warping and leaking, typical of rigid straight tube designs. This construction utilizes heavy material with flexibility to provide extreme safety and long life. 6. Heavy Insulated Cabinet The cabinet is durably constructed with two thicknesses of heavy steel, insulated on all sides with high temperature thermal fiber insulation to effectively reduce heat losses to a minimum. 7. Easily Inspected Both the upper and lower headers can be conveniently inspected internally. Parker Hot Water Boilers can be internally cleaned quickly, safely, and inexpensively with chemicals. INDUSTRIAL "Never a Compromise for Quality or Safety" PARKER BOILER CO. 5930 Bandini Boulevard Los Angeles, CA 90040 Tel (323) 727-9800 Fax (323) 722-2848 www.parkerboiler.com BROCHURE 201 0J5

SM - SKINNY MIKE SPEC. SHEET D-201-I-SM PARKER DIRECT FIRED HOT WATER BOILER 0E6 T300 TO T1140 ATMOSPHERIC GAS FIRED 18A. SAFETY VALVE 1WB 1WA 1WC Models T970 & T1140 furnished with flanged headers and safety relief valve at hot water outlet. TOP VIEW 15. HOT WATER OUTLET 16. WATER INLET 4. ELECT. CONTROL PANEL 18A. SAFETY VALVE 21. M.R. HIGH LIMIT & OPERATING CONTROL 20. TEMPERATURE PRESSURE GAUGE 4A. DRAFT HOOD SECTION T970 & T1140 BARO. DAMPER SHOWN WITH VERTICAL OUTLET (SPECIAL ORDER) 3HB or 3HC 17D. DRAIN 3HA 15H. FRONT VIEW 7. GAS INLET 2LA 2LB 7H. 16H. SIDE VIEW INSPECTION DOOR d201-sm.dwg NO. MODEL NO. T300 T395 T490 T600 T760 T970 T1140 A BTU Input 1000's BTU/HR. 300 395 490 600 760 970 1140 B BTU Output 1000's BTU/HR. 240 316 392 480 608 776 912 C Heating Surface SQ. FT. 40.5 67 67 77 106 120 133 1WA Width of Cabinet Only IN. 16 22 22 22 22 26 26 1WB Width Overall Including Controls IN. 26 32 34 34 34 48 48 1WC Minimum Header Width - Less Fittings (Blind Flanges on T970 & T1140) IN. 23 29 29 29 29 34.5 34.5 2LA Length of Cabinet Only IN. 39 35 35 40 54 49 54 2LB Length Overall IN. 39 35 35 40 54 49 54 3HA Height of Cabinet Only IN. 38 43 43 43 43 43 43 3HB Height Overall Including Draft Hood (Standard) IN. 68 75 75 76 77 79 83 3HC Height Overall Inclu. Baro. Damper (Vert. /Horizont. Outlet)-(Spec. Order) IN. 57/55 62/60 62/60 62/60 65/62 69/65 69/65 4A Vent Stack Diameter with Draft Hood (Standard) IN. 8 10 10 12 12 14 16 4B Vent Stack Diameter with Barometric Damper (Special Order) IN. 8 8 8 8 10 12 12 7A Std. Nat. Gas Inlet Size IN. 3/4 3/4 1 1 1 1-1/2 1-1/2 7A1 Std. Nat. Gas Inlet Supply Press: Max: 14" WC; Min: " WC IN. WC 7 7 7 7 7 7 7 7B Hi Press. Nat. & Propane Gas Inlet Size/Supply Press. 1-5 PSI IN. 3/4 3/4 3/4 3/4 3/4 1-1/2 1-1/2 7H Gas Inlet Height From Floor IN. 6 5 5 5 5 5 5 15 Hot Water Outlet Size (NPT Except * T970 & T1140 Class 150 Flanged) IN. 1-1/2 2 2 2 2 3* 3* 15H Hot Water Outlet Height From Floor IN. 32 37 37 37 37 37 37 16 Water Inlet Size (NPT Except * T970 & T1140 Class 150 Flanged) IN. 1-1/2 2 2 2 2 3* 3* 16H Water Inlet Height From Floor IN. 15 17 17 17 17 17 17 17D Drain Opening Outlet Side Bottom Header IN. 3/4 1 1 1 1 1 1-1/4 18AHP Safety Relief Valve Drain Size- 125 PSI, 250 0 F, "H" Code OUTLET IN. 3/4 3/4 3/4 3/4 3/4 3/4 3/4 18ALP Safety Relief Valve Drain Size- 30 PSI, 250 0 F, "H" Code OUTLET IN. 3/4 1 1 1 1-1/4 1-1/4 1-1/2 J Water Capacity GAL. 5.0 8.3 8.3 9.5 13 16 18 K L Net Weight of Boiler Domestic Crated Shipping Weight of Boiler LBS. LBS. 460 560 755 880 755 880 920 1060 1190 1340 1365 1520 1500 1660 Draft Hood Vent Connector Baro. Damper Chimney Connector. D-201-I (T300-T1140) sm

PARKER DIRECT FIRED HOT WATER BOILER SPEC. SHEET D-201-I T300 TO T1140 ATMOSPHERIC GAS FIRED 5A NO. MODEL NO. T300 T395 T490 T600 T760 T970 T1140 A BTU Input 1000's BTU/HR. 300 395 490 600 760 970 1140 B BTU Output 1000's BTU/HR. 240 316 392 480 608 776 912 C Heating Surface SQ. FT. 40.5 67 67 77 106 120 133 1WA Width of Cabinet Only IN. 16 22 22 22 22 26 26 1WB Width Overall Including Controls IN. 31 37 39 39 39 48 48 1WC Minimum Header Width - Less Fittings (Blind Flanges on T970 & T1140) IN. 28 34 34 34 34 41 41 2LA Length of Cabinet Only IN. 39 35 35 40 54 49 54 2LB Length Overall IN. 39 35 35 40 54 49 54 3HA Height of Cabinet Only IN. 38 43 43 43 43 43 43 3HB Height Overall Including Draft Hood(s) (Standard) IN. 68 75 75 76 77 79 83 3HC Height Overall Inclu. Barometric Damper (Vert. Outlet/Horizont. Outlet)-(Spec. Order) IN. 57/55 62/60 62/60 62/60 65/62 69/65 69/65 4A Vent Stack Diameter with Draft Hood (Standard) IN. 8 10 10 12 12 14 16 4B Vent Stack Diameter with Barometric Damper (Special Order) IN. 8 8 8 8 10 12 12 7A Std. Nat. Gas Inlet Size IN. 3/4 3/4 1 1 1 1-1/2 1-1/2 7A1 Std. Nat. Gas Inlet Supply Press: Max: 14" WC; Min: 7" WC IN. WC 7 7 7 7 7 7 7 7A2 Manifold Pressure at Burner IN. WC 4 4 4 4 4 4 4 7B Hi Press. Nat. & Propane Gas Inlet Size/Supply Press. 1-5 PSI IN. 3/4 3/4 3/4 3/4 3/4 1-1/2 1-1/2 7B2 Propane Manifold Press. at Burner IN. WC 18 18 18 18 18 18 18 7H Gas Inlet Height From Floor IN. 6 5 5 5 5 5 5 15 Hot Water Outlet Size (NPT Except * T970 & T1140 Class 150 Flanged) IN. 1-1/2 2 2 2 2 3 * 3 * 15H Hot Water Outlet Height From Floor IN. 32 37 37 37 37 37 37 16 Water Inlet Size (NPT Except * T970 & T1140 Class 150 Flanged) IN. 1-1/2 2 2 2 2 3 * 3 * 16H Water Inlet Height From Floor IN. 15 17 17 17 17 17 17 17D Drain Opening(s) (T970 & T1140 1" Inlet Side of Boiler)Outlet Side Outlet Side IN. 3/4 1 1 1 1 1 1-1/4 18AHP Safety Relief Valve Drain Size- 125 PSI, 250 0 F, "H" Code OUTLET IN. 3/4 3/4 3/4 3/4 3/4 3/4 3/4 18ALP Safety Relief Valve Drain Size- 30 PSI, 250 0 F, "H" Code OUTLET IN. 3/4 1 1 1 1-1/4 1-1/4 1-1/2 J Water Capacity GAL. 5.0 8.3 8.3 9.5 13 16 18 K Net Weight of Boiler LBS. 460 755 755 920 1190 1365 1500 L Domestic Crated Shipping Weight of Boiler LBS. 560 880 880 1060 1340 1520 1660 Draft Hood Vent Connector Baro. Damper Chimney Connector D-201-I.doc

SPEC. SHEET D-201-I 5A PARKER DIRECT FIRED HOT WATER BOILER T1460 TO T6800 - ATMOSPHERIC GAS FIRED NO. MODEL NO. T1460 T1730 T2160* T2600 T2970 T3600 T3900 T4600 T5700 T6800 A BTU Input 1000's BTU/HR. 1460 1730 2160 2600 2970 3600 3900 4600 5700 6800 B BTU Output 1000's BTU/HR. 1168 1384 1728 2080 2376 2880 3120 3680 4560 5440 C Heating Surface SQ. FT. 193 220 285 337 364 440 493 573 678 840 1WA Width of Cabinet Only IN. 32 38 38 38 48 54 54 54 55 55 1WB Width Overall Including Controls IN. 41 52 52 53 65 69 70 72 72 72 2LA Length of Cabinet Only IN. 62 59 73 83 73 77 86 102 119 145 2LB Length Overall IN. 83 81 95 105 95 101 110 125 142 172 2LC Header Length less Blind Flanges IN. 78 76 90 101 90 97 106 121 138 168 3HA Height of Cabinet Only IN. 52 52 52 52 52 56 56 56 56 56 3HB Height Overall Including Draft Hood(s) - (Standard) IN. 94 94 96 92 94 98 98 100 102 104 3HC Ht. Overall Inclu. Baro. Damper (Vert./Horiz. Outlet)(Spec. Order) IN. 80/78 80/78 82/81 86/83 86/83 90/90 96/96 96/96 96/99 100/102 4A Vent Stack Diameter with Draft Hood(s) - (Standard) IN. (1) 18 (1) 18 (1) 20 (2) 16 (2) 18 (2) 18 (2) 18 (2) 20 (2) 22 (2) 24 4B Vent Stack Diameter with Barometric Damper IN. (1) 14 (1) 14 (1) 16 (1) 18 (1) 18 (1) 20 (1) 22 (1) 22 (1) 26 (1) 28 7A Std. Nat. Gas Inlet Size IN. 1-1/2 2 2 2 2 2-1/2 2-1/2 3 3 3 7A1 Std. Nat. Gas Inlet Supply Pressure; Max: 14" WC; Min. IN. WC 7 7 7 7 7 7 7 7 10 10 7A2 Nat. Gas Manifold Pressure at Burner IN. WC 4 4 4 4 4 4 4 4 4 4 7B Hi Press. Nat. & Propane Gas Inlet Size Supply Press. 1-5 PSI IN. 1-1/2 1-1/2 1-1/2 1-1/2 1-1/2 1-1/2 1-1/2 2 2 2 7B1 Propane Manifold Pressure at Burner: IN. WC 18 18 18 18 18 18 18 18 18 18 7H Gas Inlet Height From Floor IN. 7 7 7 7 7 19 19 19 19 19 15 Hot Water Outlet Size (Class 150 Flanged) IN. 3 4 4 4 4 5 5 5 6 6 15H Hot Water Outlet Height From Floor IN. 46 46 46 46 46 47 47 47 47 47 16 Water Inlet Size (Class 150 Flanged) IN. 3 4 4 4 4 5 5 5 6 6 16H Water Inlet Height From Floor IN. 20 20 20 20 20 21 21 21 21 21 17D Drain Openings (1" Inlet Side of Boiler) Outlet Side IN. 1-1/4 1-1/4 1-1/2 1-1/2 1-1/2 1-1/2 1-1/2 1-1/2 2 2 18AHP Safety Relief Valve Drain Size-125 PSI, 250 0 F, "H" Code OUTLET IN. 3/4 1 1 1-1/4 1-1/4 1-1/4 1-1/4 (2) 1 (2) 1-1/4 (2) 1-1/4 18ALP Safety Relief Valve Drain Size- 30 PSI, 250 0 F, "H" Code OUTLET IN. 1-1/2 2 2 2-1/2 2-1/2 2-1/2 2-1/2 (2) 2 (2) 2-1/2 (2) 2-1/2 J Water Capacity GAL. 27 34 43 49 53 67 75 90 110 135 K Net Weight of Boiler LBS. 2390 2550 3000 3450 3840 4475 5050 6420 7300 8775 L Domestic Crated Shipping Weight of Boiler LBS. 2590 2800 3300 3800 4240 4900 5500 6995 8000 9700 Draft Hood Vent Connector Baro. Damper Chimney Connector Recommended Clearances for Access: Inspection Doors 18"; Controls 24"; Electrical Panel 30: Additional Space may be required by Local Codes T1995 available with same dimensions as T2160 except: 1995MBTU/Input; 1596MBTU/Output. D-201-I.doc

PARKER DIRECT FIRED HOT WATER BOILER SPEC. SHEET D-201-IE T300 TO T1140 ATMOSPHERIC GAS FIRED OUTDOOR MODEL 8D NO. MODEL NO. T300 T395 T490 T600 T760 T970 T1140 A BTU Input 1000's BTU/HR. 300 395 490 600 760 970 1140 B BTU Output 1000's BTU/HR. 240 316 392 480 608 776 912 C Heating Surface SQ. FT. 40.5 67 67 77 106 120 133 1WA Width of Cabinet Only IN. 16 22 22 22 22 26 26 1WB Width Overall Including Wind Skirts IN. 40 46 46 46 46 50 50 1WC Minimum Header Width - Less Fittings (Blind Flanges on T970 & T1140) IN. 28 34 34 34 34 41 41 2LA Length of Cabinet Only IN. 39 35 35 40 54 49 54 2LB Length Overall Including Wind Skirts IN. 55 51 51 56 70 65 70 3HA Height of Cabinet Only IN. 38 43 43 43 43 43 43 3HB Height Overall Including Draft Hood (Std)/3-0 Stub Stack w/americap (Approx.) IN. 68/85 75/92 75/92 76/94 77/94 79/97 83/98 3HC Height Overall Inclu. Barometric Damper (Vert. Outlet/Horizont. Outlet)-(Spec.Order). IN. 57/55 62/60 62/60 62/60 65/62 69/65 69/65 4A,C Vent Stack Diameter with Draft Hood (Std) or Americap IN. 8 10 10 12 12 14 16 4B Vent Stack Diameter with Barometric Damper (Special Order) IN. 8 8 8 8 10 12 12 7A Std. Nat. Gas Inlet Size IN. 3/4 3/4 1 1 1 1-1/2 1-1/2 7A1 Std. Nat. Gas Inlet Supply Press: Max: 14" WC; Min: 7" WC IN. WC 7 7 7 7 7 7 7 7A2 Manifold Pressure at Burner IN. WC 4 4 4 4 4 4 4 7B Hi Press. Nat. & Propane Gas Inlet Size/Supply Press. 1-5 PSI IN. 3/4 3/4 3/4 3/4 3/4 1-1/2 1-1/2 7B2 Propane Manifold Press. at Burner IN. WC 18 18 18 18 18 18 18 7H Gas Inlet Height From Floor IN. 6 5 5 5 5 5 5 15 Hot Water Outlet Size (NPT Except * T970 & T1140 Class 150 Flanged) IN. 1-1/2 2 2 2 2 3 * 3 * 15H Hot Water Outlet Height From Floor IN. 32 37 37 37 37 37 37 16 Water Inlet Size (NPT Except * T970 & T1140 Class 150 Flanged) IN. 1-1/2 2 2 2 2 3 * 3 * 16H Water Inlet Height From Floor IN. 15 17 17 17 17 17 17 17D Drain Opening(s) (T970 & T1140 1" Inlet Side of Boiler) Outlet Side IN. 3/4 1 1 1 1 1 1-1/4 18AHP Safety Relief Valve Drain Size- 125 PSI, 250 0 F, "H" Code OUTLET IN. 3/4 3/4 3/4 3/4 3/4 3/4 3/4 18ALP Safety Relief Valve Drain Size- 30 PSI, 250 0 F, "H" Code OUTLET IN. 3/4 1 1 1 1-1/4 1-1/4 1-1/2 J Water Capacity GAL. 5.0 8.3 8.3 9.5 13 16 18 K Net Weight of Boiler LBS. 570 870 870 1040 1330 1500 1645 L Domestic Crated Shipping Weight of Boiler LBS. 670 995 995 1180 1480 1655 1805 Draft Hood Vent Connector Baro. Damper Chimney Connector D-201-IE.DOC

SPEC. SHEET D-201-IE 0D2 PARKER DIRECT FIRED HOT WATER BOILER T1460 TO T6800 - ATMOSPHERIC GAS FIRED - OUTDOOR NO. MODEL NO. T1460 T1730 T2160* T2600 T2970 T3600 T3900 T4600 T5700 T6800 A BTU Input 1000's BTU/HR 1460 1730 2160 2600 2970 3600 3900 4600 5700 6800 B BTU Output 1000's BTU/HR. 1168 1384 1728 2080 2376 2880 3120 3680 4560 5440 C Heating Surface SQ. FT. 193 220 285 337 364 440 493 573 678 840 1WA Width of Cabinet Only IN. 32 38 38 38 48 54 54 54 55 55 1WB Width Overall Including Controls IN. 41 52 52 53 65 69 70 72 72 72 2LA Length of Cabinet Only IN. 62 59 73 83 73 77 86 102 119 145 2LB Length Overall IN. 83 81 95 105 95 101 110 135 142 172 2LC Header Length less Blind Flanges IN. 78 76 90 101 90 97 106 121 138 168 3HA Height of Cabinet Only IN. 52 52 52 52 52 56 56 56 56 56 3HB Ht. Overall Inclu. Draft Hood(s)-(Std) IN. 94 94 96 92 94 98 98 100 102 104 3HB1 Ht. Overall Inclu. 3-0 Stub Stack & Americap IN. 108 108 111 107 108 112 112 115 117 118 3HC Ht. Overall Inclu. Baro. Damper(Vert. /Horiz. Outlet)(Special Order) IN. 80/78 80/78 82/81 86/83 86/83 90/90 96/96 96/96 96/99 100/102 4A,C Vent Stack Diameter with Draft Hood(s) or Americap IN. (1) 18 (1) 18 (1) 20 (2) 16 (2) 18 (2) 18 (2) 18 (2) 20 (2) 22 (2) 24 4B Vent Stack Diameter with Barometric Damper (Special Order) IN. (1) 14 (1) 14 (1) 16 (1) 18 (1) 18 (1) 20 (1) 22 (1) 22 (1) 26 (1) 28 7A Std. Nat. Gas Inlet Size IN. 1-1/2 2 2 2 2 2-1/2 2-1/2 3 3 3 7A1 Std. Nat. Gas Inlet Supply Pressure; Max: 14" WC; Min. IN. WC 7 7 7 7 7 7 7 7 10 10 7A2 Nat. Gas Manifold Pressure at Burner IN. WC 4 4 4 4 4 4 4 4 4 4 7B Hi Press. Nat. & Propane Gas Inlet Size Supply Press. 1-5 PSI IN. 1-1/2 1-1/2 1-1/2 1-1/2 1-1/2 1-1/2 1-1/2 2 2 2 7B1 Propane Manifold Pressure at Burner: IN. WC 18 18 18 18 18 18 18 18 18 18 7H Gas Inlet Height From Floor IN. 7 7 7 7 7 19 19 19 19 19 15 Hot Water Outlet Size (Class 150 Flanged) IN. 3 4 4 4 4 5 5 5 6 6 15H Hot Water Outlet Height From Floor IN. 46 46 46 46 46 47 47 47 47 47 16 Water Inlet Size (Class 150 Flanged) IN. 3 4 4 4 4 5 5 5 6 6 16H Water Inlet Height From Floor IN. 20 20 20 20 20 21 21 21 21 21 17D Drain Openings (1" Inlet Side of Boiler) Outlet Side IN. 1-1/4 1-1/4 1-1/2 1-1/2 1-1/2 1-1/2 1-1/2 1-1/2 2 2 18AHP Safety Relief Valve Drain Size-125 PSI, 250 0 F,"H" Code OUTLET IN. 3/4 1 1 1-1/4 1-1/4 1-1/4 1-1/4 (2) 1 (2) 1-1/4 (2) 1-1/4 18ALP Safety Relief Valve Drain Size- 30 PSI, 250 0 F, "H" Code OUTLET IN. 1-1/2 2 2 2-1/2 2-1/2 2-1/2 2-1/2 (2) 2 (2) 2-1/2 (2) 2-1/2 J Water Capacity GAL. 27 34 43 49 53 67 75 90 110 135 K Net Weight of Boiler LBS. 2534 2701 3170 3612 4026 4672 5254 6648 7543 9038 L Domestic Crated Shipping Weight of Boiler LBS. 2734 2951 3470 3962 4426 5097 5704 7223 8243 9963 Draft Hood Vent Connector Baro. Damper Chimney Connector * T1995 available with same dimensions as T2160 except: 1995MBTU/Input; 1596MBTU/Output. D-201-IE.DOC

PARKER DIRECT FIRED HOT WATER BOILER SPEC. SHEET D-201-ISV T300 TO T1140 - ATMOSPHERIC GAS FIRED WITH STACKLESS VENT OD1 NO. MODEL NO. T300 T395 T490 T600 T760 T970 T1140 A BTU Input 1000's BTU/HR. 300 395 490 600 760 970 1140 B BTU Output 1000's BTU/HR. 240 316 392 480 608 776 912 C Heating Surface SQ. FT. 40.5 67 67 77 106 120 133 1WA Width of Cabinet Only IN. 16 22 22 22 22 26 26 1WB Width Overall Including Controls IN. 31 37 39 39 39 48 48 1WC Minimum Header Width - Less Fittings (Blind Flanges on T970 & T1140) IN. 28 34 34 34 34 41 41 1WD Frame Width Overall of Stackless Vent IN. 16 22 22 22 22 26 26 2LA Length of Cabinet Only IN. 39 35 35 40 54 49 54 2LB Length Overall IN. 55 51 51 56 70 65 70 2LC Frame Length Overall of Stackless Vent IN. 24 26 26 28 28 28 28 3HA Height of Cabinet Only IN. 38 43 43 43 43 43 43 3HB Height Overall Including Stackless Vent IN. 63 68 68 68 68 68 68 4 Vent Stack Diameter IN. 8 10 10 12 12 14 16 7A Std. Nat. Gas Inlet Size IN. 3/4 3/4 1 1 1 1-1/2 1-1/2 7A1 Std. Nat. Gas Inlet Supply Press: Max: 14" WC; Min: 7" WC IN. WC 7 7 7 7 7 7 7 7A2 Manifold Pressure at Burner IN. WC 4 4 4 4 4 4 4 7B Hi Press. Nat. & Propane Gas Inlet Size/Supply Press. 1-5 PSI IN. 3/4 3/4 3/4 3/4 3/4 1-1/2 1-1/2 7B2 Propane Manifold Press. at Burner IN. WC 18 18 18 18 18 18 18 7H Gas Inlet Height From Floor IN. 6 5 5 5 5 5 5 15 Hot Water Outlet Size (NPT Except * T970 & T1140 Class 150 Flanged) IN. 1-1/2 2 2 2 2 3 * 3 * 15H Hot Water Outlet Height From Floor IN. 32 37 37 37 37 37 37 16 Water Inlet Size (NPT Except * T970 & T1140 Class 150 Flanged) IN. 1-1/2 2 2 2 2 3 * 3 * 16H Water Inlet Height From Floor IN. 15 17 17 17 17 17 17 17D Drain Opening(s) (T970 & T1140 1" Inlet Side of Boiler) Outlet Side IN. 3/4 1 1 1 1 1 1-1/4 18AHP Safety Relief Valve Drain Size- 125 PSI, 250 0 F, "H" Code OUTLET IN. 3/4 3/4 3/4 3/4 3/4 3/4 3/4 18ALP Safety Relief Valve Drain Size- 30 PSI, 250 0 F, "H" Code OUTLET IN. 3/4 1 1 1 1-1/4 1-1/4 1-1/2 J Water Capacity GAL. 5.0 8.3 8.3 9.5 13 16 18 K Net Weight of Boiler LBS. L Domestic Crated Shipping Weight of Boiler LBS. D-201-ISV.DOC

SPEC. SHEET D-201-ISV 9C PARKER DIRECT FIRED HOT WATER BOILER T1460 TO T6800 ATMOSPHERIC GAS FIRED WITH STACKLESS VENT 1" NO. MODEL NO. T1460 T1730 T2160* T2600 T2970 T3600 T3900 T4600 T5700 T6800 A BTU Input 1000'S BTU/HR. 1460 1730 2160 2600 2970 3600 3900 4600 5700 6800 B BTU Output 1000'S BTU/HR. 1168 1384 1728 2080 2376 2880 3120 3680 4560 5440 C Heating Surface SQ. FT. 193 220 285 337 364 440 493 573 678 840 1WA Width of Cabinet Only IN. 32 38 38 38 48 54 54 54 55 55 1WB Width Overall Including Controls IN. 48 54 54 54 64 74 74 74 75 75 2LA Length of Cabinet Only IN. 62 59 73 83 73 77 86 102 119 145 2LB Length Overall IN. 90 87 101 111 101 109 118 134 151 177 2LC Header Length less Blind Flanges IN. 78 76 90 101 90 97 106 121 138 168 3HA Height of Cabinet Only IN. 52 52 52 52 52 56 56 56 56 56 3HB Height Overall Including Stackless Vent IN. 77 77 77 77 77 81 81 81 81 81 4 Vent Stack Diameter IN. (1) 18 (1) 18 (1) 20 (2) 16 (2) 18 (2) 18 (2) 18 (2) 20 (2) 22 (2) 24 7A Std. Nat. Gas Inlet Size IN. 1-1/2 2 2 2 2 2-1/2 2-1/2 3 3 3 7A1 Std. Nat. Gas Inlet Supply Pressure: Max: 14" WC; Min. IN. WC. 7 7 7 7 7 7 7 7 10 10 7A2 Nat. Gas Manifold Pressure at Burner IN. WC. 4 4 4 4 4 4 4 4 4 4 7B Hi Press. Nat. & Propane Gas Inlet Size Supply Press. 1-5 PSI IN. 1-1/2 1-1/2 1-1/2 1-1/2 1-1/2 1-1/2 1-1/2 2 2 2 7B1 Propane Manifold Pressure at Burner: IN. WC. 18 18 18 18 18 18 18 18 18 18 7H Gas Inlet Height From Floor IN. 7 7 7 7 7 19 19 19 19 19 15 Hot Water Outlet Size (Class 150 Flanged) IN. 3 4 4 4 4 5 5 5 6 6 15H Hot Water Outlet Height From Floor IN. 46 46 46 46 46 47 47 47 47 47 16 Water Inlet Size (Class 150 Flanged) IN. 3 4 4 4 4 5 5 5 6 6 16H Water Inlet Height From Floor IN. 20 20 20 20 20 21 21 21 21 21 17D Drain Openings (1" Inlet Side of Boiler) Outlet side IN. 1-1/4 1-1/4 1-1/2 1-1/2 1-1/2 1-1/2 1-1/2 1-1/2 2 2 18AHP Safety Relief Valve Drain Size-125 PSI, 250 F, "H" Code. OUTLET IN. 3/4 1 1 1-1/4 1-1/4 1-1/4 1-1/4 (2) 1 (2) 1-1/4 (2) 1-1/4 18ALP Safety Relief Valve Drain Size-30 PSI, 250 F, "H" Code. OUTLET IN. 1-1/2 2 2 2-1/2 2-1/2 2-1/2 2-1/2 (2) 2 (2) 2-1/2 (2) 2-1/2 J Water Capacity GAL. 27 34 43 49 53 67 75 90 110 135 K Net Weight of Boiler LBS. 2607 2785 3261 3701 4125 4787 5387 6791 7698 9211 L Domestic Crated Shipping Weight of Boiler LBS. 2807 3035 3561 4051 4525 5212 5837 7366 8398 10136 * T1995 available with same dimensions as T2160 except: 1995MBTU/input; 1596MBTU/Output. D-201-ISV(1460-6800).DOC