RL with INNOVATOR II No Heat Doors

Similar documents
RM with INNOVATOR Doors

RLNIE with INNOVATOR II

RLNI with P/N _J NSF. INNOVATOR Doors or. INNOVATOR III Doors. Certified. Technical Data Sheet. January 2018

Freedom Line RFM. Certified. with INNOVATOR Doors. Medium Temperature Technical Data Sheet P/N _B NSF. Freedom Line merchandisers are top mount

Engineering Plan Views

RMN with INNOVATOR Doors Technical Data Sheet

RLTIM with P/N _H NSF INNOVATOR. Certified. & INNOVATOR III Doors Technical Data Sheet. January 2018

Freedom Line RFLN. Certified. with INNOVATOR Doors. or INNOVATOR III Doors Low Temperature Technical Data Sheet P/N _J NSF

RLT with INNOVATOR Doors

Freedom Line RFMN. Certified. with INNOVATOR Doors Medium Temperature Technical Data Sheet P/N _J NSF. Freedom Line merchandisers are top mount

P/N _K NSF. Certified. Technical Data Sheet. March Spanish P/N Item Part # Description Wiring Item #

F-L P/N _C NSF. Certified C A. Technical Data Sheet. March Item Part # Description Wiring Item # Item Part # Description Wiring Item #

Freedom Line RFLNS. Certified. with INNOVATOR Doors. Technical Data Sheet P/N _J NSF. Freedom Line merchandisers are top mount.

FG-L P/N _C NSF. Certified. Technical Data Sheet. March 2017 H C K B. Item Part # Description Wiring Item #

FIG P/N _K NSF. Certified March 2017 J A F E B I. Technical Data Sheet. Spanish P/N

FIG-L P/N _F NSF. Certified January 2018 H C A L B. Technical Data Sheet

P1NX-E P/N _G NSF. Certified. Technical Data Sheet. October 2016

FWEL P/N _D NSF E D C H B A F. Certified January Technical Data Sheet. Item Part # Description Wiring Item #

FG-L Technical Data Sheet

P/N _F NSF Certified June 2010

FWG P/N _M NSF. Certified. DOE 2012 Energy Efficiency Compliant F J G I. Technical Data Sheet. June Data sheet-excel FWG.

PWWEE P/N _C NSF. Certified. Technical Data Sheet. October 2016

FWG-L. Certified. DOE 2012 Energy Efficiency Compliant. Technical Data Sheet P/N _D NSF. May Spanish

PWEE Technical Data Sheet

LifeLine Premier RLNIE

FWG P/N _G. NSF Certified December Technical Data Sheet F J G I P/N _G. Item Part # Description Wiring Item #

Freedom Line RFMNS. Certified. with INNOVATOR Doors. Technical Data Sheet P/N _J NSF. Freedom Line merchandisers are top mount.

P/N _D NSF. Certified. Frozen. May Merchandiser Data Sheet

M1GLE-93. P/N _G NSF Certified A E P/N F. Technical Data Sheet. July Item Part # Description Wiring Item #

Excel FWGH P/N _F NSF. Certified. Frozen. January Merchandiser Data Sheet

EXCEL FWEGH P/N _D NSF. Certifi ed. Frozen. March Merchandiser Data Sheet

P/N _G. NSF Certified February 2007 C A F G H. Technical Data Sheet P/N _G. Item Part # Description Wiring Item #

LNG P/N _H. NSF Certified February 2007 C A F G H. Technical Data Sheet P/N _H. Item Part # Description Wiring Item #

EXCEL FWEGH-L P/N _F NSF. Certifi ed. Frozen. March Merchandiser Data Sheet

P/N _D NSF. Certified. Frozen. May Merchandiser Data Sheet

BEXD-8A. Certified. Spanish P/N Technical Data Sheet P/N _C NSF. March 2017

RLNIE P/N G. P/N _G NSF Certified. Technical Data Sheet. Warning: Terminal block NOT for case-to-case wire connection!

Nosing Heater. Return Grill Heater

RL with INNOVATOR Doors

LWU Technical Data Sheet

BEXD-8A. P/N _A NSF Certified P/N_ _A C B P E D K. Technical Data Sheet. November 2010

JUMBO ISLAND FROZEN FOOD/ICE CREAM/MEDIUM TEMP MERCHANDISERS Low, Medium and Dual Temperature Self Serve Display Cases

Installation & Service Manual

Installation & Service Manual

NFW, NCW, NFWG, NCWG, NFWE, NCWE

OPTIONAL CONTROLLER. Kit P/N _A. December 2016 ANTI-CONDENSATE HEATER FOR REACH-IN GLASS DOORS. Spanish French

MD Medium Temperature Self Contained Open Vertical Merchandisers

Reach-in Merchandisers

L3MGB. THREE DECK MEAT/DELI MERCHANDISERS Medium Temperature Self Serve Display Cases

SSGB. EPH Certified to NSF-7 G B. Technical Data Sheet P/N _E. January Data sheet-excel SSGB

Medium Temperature. Installation & Operation Manual Shipped With Case Data Sheets. IMPORTANT Keep in store for

6RZLH 6RZLH. Reach-In Merchandiser 2, 3, 4 & 5 Door (Frozen Food) REFERENCE NOTES FOR ENGINEERING DATA

L6FA. MULTI-SHELF FROZEN FOOD MERCHANDISER Low Temperature Self Serve Display Cases

ISF and ISM. Low and Medium Temperature Remote and Self Contained Island Merchandisers. Installation & Service Manual IMPORTANT

FIELD-INSTALLED MOTION ACTIVATED LED DIMMER CONTROL

OPTIONAL MOTION ACTIVATED LED DIMMER CONTROL

Installation & Service Manual

ON3.5EM-NRG ON3.5EM-NRG. Narrow Multi-Deck Merchandiser with Synerg-E End Cap (Dairy/Deli/Meat/Produce) SHIPPING WEIGHT GENERAL NOTES:

P/N _B September Field Installed Dual Temp Operation E P R Controlled (Evaporator Pressure Regulator)

Installation & Service Manual

Medium Temperature. Installation & Operation Manual Shipped With Case Data Sheets. IMPORTANT Keep in store for future reference!

Medium Temperature Bulk Produce and Bakery Merchandisers

BCH Medium Temperature Merchandisers

VNRZH VNRZH. High Narrow Reach-In Merchandiser 1, 2, 3, 4, & 5 Door (Frozen Food) SHIPPING WEIGHT Case Weight VNRZH LBs GENERAL NOTES

MD Medium Temperature Self Contained Open Vertical Merchandisers

F-6 Multi-deck Frozen Food Wall Merchandisers

EcoShine II Horizontal LEDs for Multi-Deck Merchandisers Shelf, Rail and Canopy

GSVM Medium Temperature Self Contained Open Vertical Merchandisers. Installation & Service Manual

Low Temperature. Installation & Operation Manual IMPORTANT. Single Deck Wall & Island Merchandisers. Keep in store for future reference!

Installation and Operation Manual

RFLNS, RFMNS & RFLTM Freedom Line

ON4UM-NRG ON4UM-NRG. Narrow Multi-Deck Merchandiser 4', 6', 8', 12' (Dairy/Deli/Produce) SHIPPING WEIGHT GENERAL NOTES

Rear Roll-in Dairy Medium Temperature Free Standing or Suspended Merchandisers Installed in Walk-in Cooler Exterior Walls

OHMH-NRG OHMH-NRG. High Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Deli / Meat) SHIPPING WEIGHT GENERAL NOTES

O3UM-NRG O3UM-NRG. Multi-Deck Merchandiser with Synerg-E 4', 6', 8', 10', 12' (Dairy/Deli/Meat/Produce) SHIPPING WEIGHT

6DMLH-NRG 6DMLH-NRG. High Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Beverage / Dairy / Deli / Produce) SHIPPING WEIGHT GENERAL NOTES

HGL- 1, 2 & 3 BS, TS. Bottom / Top Mount Low Temperature Remote and Self Contained Glass Door Merchandisers. Installation & Service Manual IMPORTANT

Service Merchandisers

Ultra Low Front Rear Load Medium Temperature

O5MH-NRG O5MH-NRG. High Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Deli / Meat) SHIPPING WEIGHT

Self-Contained Medium Temperature Delicatessen, Dairy, Meat, Produce and Bakery Merchandisers

Installation & Service Manual

O5M-NRG O5M-NRG. Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Deli / Meat) SHIPPING WEIGHT GENERAL NOTES

N5FGA, N5NGA, N5FGNA, N5NGNA

O5DM-NRG O5DM-NRG. Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Beverage / Dairy / Deli / Produce) SHIPPING WEIGHT Case Weight O5DM-NRG ---

EcoVision Door Manual

INSTALLATION & OPERATION MANUAL

HGM-1, 2 & 3 BS, TS. Bottom / Top Mount Medium Temperature Remote and Self Contained. Installation & Service Manual. Glass Door Merchandisers

O4ID O4ID. Medium Temp Island Merchandiser 8' & 12' (Deli / Meat) ENGINEERING REFERENCE SHEET NOTES

KR Electrical Defrost Unit Coolers (PN E108318_E)

Service Merchandisers

Cold Deck Canopy and Shelf Lights and Retrofit Kit

Packaged Heat Pump. 20 Ton Rooftop Units with ReliaTel TM Controls NOTICE

KRSCP Self-Contained Walk-In Unit Installation and Service Manual Addendum

RFLN & RFMN Freedom Line

Hoshizaki America, Inc.

Self-Contained MERCHANDISERS. February

EcoVision II Plus Door Upgrade for D6 Kysor Warren Multi-deck Merchandisers

OIM OIM. Medium Temp Island Merchandiser 8' & 12' (Deli / Meat) REFERENCE NOTES FOR ENGINEERING DATA:

4A6H5049E1000B 208/230/1/ /8 7/8 7/8 7/8 DURATION 208/230/1/ /230/1/ SPINE FIN 13 LBS., 10 OZ. YES

Transcription:

RL with INNOVATOR II No Heat Doors We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped. Technical Data Sheet NSF Certified April 2017 Warning: Terminal block NOT for case-to-case wire connection! Item Part # Description Wiring Item # FAN ASSEMBLIES, AND THERMOSTATS A. 12W Standard Energy Efficient Fan Assembly (1) 0477655 Fan Motor, Evaporator (MO.4410546) 0461805 Fan Blade (FB.4780446) B. 0474033 Standard Non-adjustable (2) (CT.4440726) C. Optional Adjustable Refrigeration (3) D. 0344662 Limit (4) (CT.4440261) E. 0461814 Relay Control or (5) Fan and Anti-sweat Heater (CT.4481296)(KG Only) RELAYS F. 0342598 Anti-Sweat Control Relay (6) (120V) (RL.4480238) G. 0342599 Fan Control Relay (208V) (7) (RL.4480237) Refer to INNOVATOR REACH-IN GLASS DOOR INSTALLATION AND SERVICE manual, P/N 0425683, for Innovator II door and frame replacement parts. Item Part # (Qty.) Description Wiring Item # HEATERS H. Electric Heaters Front (208V) (8) 3015372 (1) 2 Door Models (HE.4850346) 3015373 (1) 3 Door Models (HE.4850337) 3015374 (1) 4 Door Models (HE.4850347) 3015375 (1) 5 Door Models (HE.4850323) Electric Heaters Rear (208V) (8) 3015376 (1) 2 Door Models (HE.4850358) 3015377 (1) 3 Door Models (HE.4850359) 3015378 (1) 4 Door Models (HE.4850360) 3015379 (1) 5 Door Models (HE.4850361) I. Drain Pan Heater (Electric & KoolGas) (9) (120V) 0387036 (1) 2 Door Models (HE.4850239) 0387037 (1) 3 Door Models (HE.4850240) 0387038 (1) 4 Door Models (HE.4850241) 0387039 (1) 5 Door Models (HE.4850242) LAMPS, BALLASTS, LED FIXTURES AND POWER SUPPLY J. 0430330 2 Lamp Ballast (BA.4480342) 0454319 3 Lamp Ballast (BA.4480601) 0424649 Export Ballast (BA.0424649) K. Standard Fluorescent Lamp Replace with like fixtures L. 0499399 LED Power Supply(EP.4481668) M. LED Fixture Replace with like fixtures Data sheet-reach-in RL Note: Revision Q: April 2017. Updated LED energy values. Other changes marked with a bar, circle or underline. 2017 HUSSMANN CORPORATION BRIDGETON, MO 63044-2483 U.S.A. U.S. & CANADA 1-800-922-1919 MEXICO 1-800-890-2900 WWW.HUSSMANN.COM Spanish P/N 0553987

Engineering Plan Views Reach-In 2, 3, 4 & 5 Door RL - RM - RMF Plan View 06-2009 PHYSICAL DATA Merchandiser Drip Pipe (in.) 1 1 /4 Merchandiser Liquid Line (in.) 3 /8 Merchandiser Suction Line (in.) 5 /8 Dimensions shown as in. & (mm). 4 IN (102 MM) REQUIRED AIR GAP Skid/ External Base Electrical Wireway Waste Outlet Splashguard Bottom Front Support Refrigeration Outlet Front 5-Door Shown Relay & Terminal Block Location Clearance for Door Swing 1 Dr 2 Dr 3 Dr 4 Dr 5 Dr General (A) Case Length (without ends or partitions) 31 1 /2 (800) 62 (1575) 92 1 /2 (2350) 122 7 /8 (3121) 153 3 /8 (3896) **NOTE: Each solid end adds approximately 2 3 /8 in (60 mm) to length of line up; each partition add approximately 2 3 /4 in (70 mm); case to case joints can add approximately 1 /8 in (3 mm) for gasket material. Maximum O/S dimension of case back to front 43 3 /4 (1111) 43 3 /4 (1111) 43 3 /4 (1111) 43 3 /4 (1111) 43 3 /4 (1111) (Includes bumper. Add 26 1 /2 in. (673 mm) for door swing.) Back of case to rear of splashguard 39 7 /8 (1013) 39 7 /8 (1013) 39 7 /8 (1013) 39 7 /8 (1013) 39 7 /8 (1013) Width of Skidrail 3 3 /4 (95) 3 3 /4 (95) 3 3 /4 (95) 3 3 /4 (95) 3 3 /4 (95) Width of Bottom Front Support 6 (152) 6 (152) 6 (152) 6 (152) 6 (152) Stub-up area between front support and splashguard 3 1 /8 (79) 3 1 /8 (79) 3 1 /8 (79) 3 1 /8 (79) 3 1 /8 (79) Electrical Service RH end of case to the center of nearest knockout 4 (102) 4 (102) 4 (102) 4 (102) 4 (102) RH end of case to the center of LH knockout 27 1 /2 (698) 58 (1473) 88 1 /2 (2248) 118 7 /8 (3019) 149 3 /8 (3794) Back O/S of case to center of knockout 41 5 /8 (1058) 41 5 /8 (1058) 41 5 /8 (1058) 41 5 /8 (1058) 41 5 /8 (1058) * NOTE: Electrical Field Wiring Connection Point is at terminal. Waste Outlet (B) Right end of case to center of waste outlet 15 3 /4 (400) 23 7 /8 (606) 54 1 /4 (1378) 46 1 /4 (1175) 76 5 /8 (1946) Back O/S of case to center of waste outlet 34 5 /8 (879) 34 5 /8 (879) 34 5 /8 (879) 34 5 /8 (879) 34 5 /8 (879) Water Seal Edge of water seal to center of waste outlet 13 (330) 13 (330) 13 (330) 13 (330) 13 (330) Schedule 40 PVC drip pipe 1 1 /4 (32) 1 1 /4 (32) 1 1 /4 (32) 1 1 /4 (32) 1 1 /4 (32) ** NOTE: Field installed water seal outlets, tees, and connectors are shipped with case Refrigeration Outlet RH end of case to center of RH refrigeration outlet 5 3 /8 (137) 5 3 /8 (137) 5 3 /8 (137) 5 3 /8 (137) 5 3 /8 (137) Back O/S of case to center of refrigeration outlet 32 (813) 32 (813) 32 (813) 32 (813) 32 (813) Outside bottom front supports from end of case 6 3 /4 (170) 6 3 /4 (170) 6 3 /4 (170) 6 3 /4 (170) 6 3 /4 (170) Center bottom front support from Centerline NA 24 (610) 24 (610) 24 (610) 24 (610) Distance between Center and Outside supports will vary 2 of 7 HUSSMANN U.S. & CANADA 1-800-922-1919 MEXICO 1-800-890-2900 RL with Innovator II Doors Technical Data Sheet

Reach-in 2, 3, 4 and 5 Door Models Hussmann refrigerated merchandisers configured for sale for use in the United States meet or surpass the requirements of the DOE 2017 energy efficiency standards. Standard Reach-in configuration consists of Innovator doors, energy efficient fan motors, and EcoShine II LED vertical lighting. Dimensions shown as in. & (mm). 4 In. (102 mm) Required Air Gap RL With INNOVATOR II Doors Frozen Food & Ice Cream REFRIGERATION DATA Note: This data is based on store temperature and humidity that does not exceed 75 F and 55% R.H. FF IC Discharge Air ( F) 5 12 Evaporator ( F) 9 17 Unit Sizing ( F) 12 20 Btu/hr/Door FF IC Parallel 830 900 Conventional 845 920 Average evaporator temperature shown. Use dew point for high glide refrigerants for unit sizing. Care should be taken to use the dew point in PT tables for measuring and adjusting superheat. Adjust evaporator pressure as needed to maintain discharge air temperature shown. Frame Door Shelf DEFROST DATA FF IC Frequency (hr) 24 24 Water (lb/dr/day) 1.2 1.2 (± 15% based on case configuration and product loading.) ELECTRIC FF IC Temp Term ( F) 48 48 Failsafe (minutes) 45 45 GAS Duration (minutes) 20 20 Refrigeration Outlet OFFTIME Not Recommended Fan Coil CONVENTIONAL CONTROLS Low Pressure Backup Control FF IC CI/CO (Temp F)* -18 / -34-26 /-45 Electrical Field Wiring Connection is at Terminal Electrical Stub-up Area Length Added to Lineup by each Standard End (in.) 2 Optional End with Window (in.) 1 1 /2 Optional Partition (in.) 1 1 /2 NSF Certification This merchandiser model is manufactured to meet NSF/ANSI (National Sanitation Foundation) Standard #7 requirements for construction, materials & cleanability. Indoor Unit Only, Pressure Termination (Temp F)* Not Recommended *Use a Temperature Pressure Chart to determine PSIG conversions. PHYSICAL DATA Estimated Charge ** 2Dr 1.8 lb 29 oz 0.8 kg 3Dr 2.7 lb 43 oz 1.2 kg 4Dr 3.6 lb 57 oz 1.6 kg 5Dr 4.6 lb 73 oz 2.0 kg **This is an average for all refrigerant types. Actual refrigerant charge may vary by approximately half a pound (8 oz / 0.2 kg). HUSSMANN CORPORATION BRIDGETON, MO 63044-2483 U.S.A. WWW.HUSSMANN.COM 3 of 7

RL With INNOVATOR II Doors Frozen Food & Ice Cream Hussmann recommends against frame heater cycling with Innovator doors to prevent door seals from freezing to the frames and tearing. Electrical Data 2Dr 3Dr 4Dr 5Dr Number of Fans 12W 2 3 4 5 Amperes Watts Merchandiser 2Dr 3Dr 4Dr 5Dr 2Dr 3Dr 4Dr 5Dr Evaporator Fan 120V 60Hz Standard Energy Efficient 0.60 0.90 1.20 1.50 36 54 72 90 220V 60Hz Standard Energy Efficient 0.30 0.45 0.60 0.75 36 54 72 90 Door Anti-sweat Heaters (on fan circuit) NA Frame Anti-sweat Heaters (on fan circuit) 120V 50/60Hz Standard 0.89 1.34 1.79 2.24 107 161 215 269 220V 50/60Hz Export 0.49 0.73 0.98 1.22 107 161 215 269 Minimum Circuit Ampacity 120V 60Hz Standard Energy Efficient 1.69 2.44 3.19 3.94 220V 60Hz Standard Energy Efficient 0.99 1.38 1.78 2.17 Maximum Over Current Protection 120V 20 20 20 20 Maximum Over Current Protection 220V 15 15 15 15 Drain Heaters (120V) 0.63 1.25 2.00 2.57 75 150 240 300 (Export: 220V 50 Hz) 0.34 0.76 1.22 1.53 84 168 269 336 208V Electric 6.72 10.08 13.46 16.82 1400 2100 2800 3500 (Export: 220V 50 Hz) 7.11 10.66 14.24 17.79 1564 2345 3133 3914 Standard Vertical LED Lighting 2Dr 3Dr 4Dr 5Dr 2Dr 3Dr 4Dr 5Dr Hussmann EcoShine II - A (120V) 0.31 0.46 0.62 0.77 37.1 55.6 74.2 92.7 Hussmann EcoShine II - A (220V Export) 0.17 0.25 0.34 0.42 37.1 55.6 74.2 92.7 Optional Vertical LED Lighting Hussmann EcoShine II - B (120V) 0.36 0.52 0.68 0.84 43.2 62.3 81.4 100.5 Hussmann EcoShine II - B (220V Export) 0.20 0.28 0.37 0.46 43.2 62.3 81.4 100.5 4 of 7 HUSSMANN U.S. & CANADA 1-800-922-1919 MEXICO 1-800-890-2900 RL with Innovator II Doors Technical Data Sheet

RL With INNOVATOR II Doors Frozen Food & Ice Cream Product Data Recommended Usable Cube 1 (Cu Ft/Dr) AHRI Total Display Area 2 (Sq Ft/Dr) Shelf Area 3 (Sq Ft/Dr) 23.46 ft 3 /Dr (0.66 m 3 /Dr) 13.04 ft 2 /Dr (1.21 m 2 /Dr) 29.32 ft 2 /Dr (2.72 m 2 /Dr) 1 AHRI Refrigerated Volume less shelving and other unusable space: Refrigerated Volume/Unit of Length, ft 3 /ft [m 3 /m] 2 Computed using AHRI 1200 standard methodology: Total Display Area, ft 2 [m 2 ]/Unit of Length, ft [m] 3 Shelf surface area is composed of bottom deck plus standard shelf complement, as shown in the Hussmann Product Reference Guide. The standard shelf complement for this model is (5) rows of 22-inch shelves. ESTIMATED SHIPPING WEIGHT 5 Case Solid End 1 Dr 2 Dr 3 Dr 4 Dr 5 Dr (each) lb (kg) NA (NA) 997 (453) 1295 (589) 1595 (725) 1874 (852) 55 (25) 5 Actual weights will vary according to optional kits included. HUSSMANN CORPORATION BRIDGETON, MO 63044-2483 U.S.A. WWW.HUSSMANN.COM 5 of 7

Fan and Heater Circuits - Electric (standard) Low Temperature CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS R = Red P = Purple 2P = Purple (2 Bands) DB = Dark Blue BK = Black LB = Light Blue BR = Brown Y = Yellow OR = Orange W = White THESE ARE MARKER COLORS (WIRE MAY VARY.) Rear Heater Front Heater Evaporator Fan Relay Coil Limit CAUTION: When multiplexing merchandisers equipped with defrost heaters, if branch circuit overcurrent protection is larger than the individual merchandiser s defrost circuit load, then additional supplemental overcurrent protection may be required per NEC Articles 210 and 240. Evaporator Fans Rod Heater (Drain) Refer to Innovator Reach-In Glass Door, Installation and Service manual, P/N 0425683, for Innovator door and frame replacement parts. Frame A.S. Heaters Door A.S. Heaters Switch Refer to Innovator Door Manual for Lighting Diagrams Termination Refrigeration (Optional) FIELD WIRED Termination Pink Dark Blue To Condensing Unit Low Temperature with Electric Terminal Blocks in Raceway Removable Internal Removable External Jumpers DOORS A/S DEFROST HEATERS Jumpers FANS & LIGHTS (208V) A.S. (120V) (120V) LIGHTS (Neutral) FANS & A.S. (Neutral) Electric Sequence - Low Temperature 1. Power from the defrost contactor energizes Heaters and 208V Evaporator Coil (7). Relay Contacts open the fan circuit and energizes the Drain Pan Heater. 2. If the Heater raises internal air temperature above 90 F, the Limit (4) will open. 3. Temperature rise of the evaporator closes the Relay Control (5) at about 35 F, energizing 120V A.S. Relay Coil (6). This relay s contacts open the Frame and Door Heater Circuits. 4. When Termination ends defrost period, the defrost contactor opens the Heater and Evaporator Coil Circuits. The Drain Pan Heater goes off and fans are on. 5. Temperature fall of the evaporator opens the Relay Control (5) at about 20 F, de-energizing 120V A.S. Relay Coil (6). A.S. Relay Contacts close the Frame and Door Heater Circuits. 6 of 7 HUSSMANN U.S. & CANADA 1-800-922-1919 MEXICO 1-800-890-2900 RL with Innovator II Doors Technical Data Sheet

Fan and Heater Circuits - Gas (optional) Low Temperature CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS R = Red P = Purple 2P = Purple (2 Bands) DB = Dark Blue BK = Black LB = Light Blue BR = Brown Y = Yellow OR = Orange W = White THESE ARE MARKER COLORS (WIRE MAY VARY.) Evaporator Fans Limit Relay Control Rod Heater (Drain) Coil c Refer to Innovator Reach-In Glass Door, Installation and Service manual, P/N 0425683, for Innovator door and frame replacement parts. Frame A.S. Heaters Door A.S. Heaters Switch Refer to Innovator Door Manual for Lighting Diagrams Refrigeration (Optional) Low Temperature with Gas Terminal Blocks in Raceway Pink To Condensing Unit Removable External Jumpers LIGHTS LIGHTS DOORS A/S FANS & A.S. (Neutral) FANS & (120V) (Neutral) A.S. (120V) Permanent Internal Jumpers Gas Sequence - Low Temperature 1. vapor enters evaporator causing a rise in temperature. At about 35 F the Control Relay (5) closes the Coil (7) and Control Relay Coil (6) circuit. The Coil opens the Fan, Door Heater, and Frame Heater circuits, while energizing the Drain Pan Heater (9). 2. If the Drain Pan Heater (9) raises internal air temperature above 90 F, the Heater Limit (4) will open. 3. When the defrost timer ends a defrost period, the evaporator temperature will start to fall. At about 20 F, the Control Relay will open, de-energizing the Control Relay Coil and Coil (7). Control and s will open the Drain Pan Heater circuits, and will close the Fan, Door Heater, and Frame Heater circuits. HUSSMANN CORPORATION BRIDGETON, MO 63044-2483 U.S.A. WWW.HUSSMANN.COM 7 of 7