WFD Series Waterflow Detector

Similar documents
Series TY-B 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage General Description

Sprinkler Identification Numbers. TY3351 Horizontal TY3451 Vertical. Technical Data

Series TY-FRB 5.6 K-factor Horizontal and Vertical Sidewall Sprinklers Quick Response, Standard Coverage General Description

Series TY-B 5.6 K-factor Horizontal and Vertical Sidewall Sprinklers Standard Response, Standard Coverage General Description

Sprinkler Identification Numbers

Series ELO-231B 11.2 K-factor Upright and Pendent Sprinklers. Standard Response, Standard Coverage, General Description

Series TY-B 5.6 K-factor Horizontal and Vertical Sidewall Sprinklers Standard Response, Standard Coverage General Description

* Temperature rating is FIGURE K-FACTOR QUICK RESPONSE SERIES TY-FRB HORIZONTAL SIDEWALL (TY3331) SPRINKLERS

Model/Sprinkler Identification Numbers

Series TY-B 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage General Description

Model/Sprinkler Identification Number JULY, 2011 WARNINGS

Series ELO-231 Upright and Pendent Sprinklers. Standard Response, Standard Coverage, General Description

Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description

WRENCH FLATS NPT 1/2" 7/16" (11,1 mm) NOMINAL MAKE-IN. 1-1/2" (38,1 mm) 2-3/16" (55,6 mm) WRENCH NPT. (12,7 mm) NOMINAL MAKE-IN.

Series EC-11 and EC-14 Sprinklers, 11.2 K and 14.0 K Upright, and Pendent Extended Coverage Light and Ordinary Hazard General Description

Series TY-FRL 5.6 and 8.0 K-factor Extended Coverage Horizontal Sidewall Sprinklers Quick & Standard Response (Light Hazard)

Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage

Series TY-B & TY-FRB, 10 mm Orifice, ISO 7/1-R3/8 Upright, Pendent, and Recessed Pendent Sprinklers Standard and Quick Response General Description

Series LFII Residential Pendent Sprinklers 4.9 K-factor General Description

Series EC K-factor Extended Coverage (Light Hazard) Pendent and Recessed Pendent Sprinklers General Description

Series TY-B 5.6 and 8.0 K-factor Upright and Pendent Intermediate Level Sprinklers Standard Response General Description

Sprinkler Identification Number. Page 1 of 6 AUGUST 2018 TFP288. Worldwide Contacts.

Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description

The Series LFII (TY3596) Residential

RAPID RESPONSE Series LFII Residential Sprinklers 4.2 K-factor Horizontal Sidewall Wet Pipe and Dry Pipe Systems General Description

Series EC-11 and EC-14 Sprinklers, 11.2 K and 14.0 K Upright and Pendent Extended Coverage Light and Ordinary Hazard General Description

Model CHEC 8.0 K-factor Concealed Horizontal Extended Coverage Quick Response Light Hazard, Sidewall Sprinklers General Description

ILLUSION 11.2 K-factor Extra Large Orifice Concealed Pendent Sprinklers Quick Response, Standard Coverage General Description

proven to help in the control of residential fires and to improve the chance for occupants to escape or be evacuated. Dry Pipe System Application

proven to help in the control of residential fires and to improve the chance for occupants to escape or be evacuated. Dry Pipe System Application

O-RING UPRIGHT SHIELD WRENCH FLATS WRENCH FLATS FIGURE 1 SERIES TY-B UPRIGHT (TY3153) AND PENDENT (TY3251) SPRINKLERS

Series EC K-factor Extended Coverage (Light Hazard) Pendent and Recessed Pendent Sprinklers General Description

Model ELOC 11.2 K-factor Extra Large Orifice Concealed Pendent Sprinklers Quick and Standard Response, Extended Coverage

Series TY-FRL 5.6 and 8.0 K-factor Extended Coverage Horizontal Sidewall Sprinklers Quick & Standard Response (Light Hazard) General Description

RAPID RESPONSE Series LFII Residential Sprinklers 5.8 K-factor Horizontal Sidewall, NFPA 13 Optimized Wet Pipe Systems

Series TY-FRL 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description

Sprinkler Identification Numbers

Model SW-20 and SW K-factor Extended Coverage Ordinary Hazard Horizontal Sidewall Sprinklers (Standard Response)

ESCUTCHEON PLATE SEATING SURFACE. 1-11/16" (42,7 mm) CROSS SECTION

Submittal Packages Detailed with Items and Reviewers

RAPID RESPONSE Series LFII Residential Sprinklers 5.6 K-factor Horizontal Sidewall, NFPA 13 Optimized Wet Pipe Systems

Sprinkler Identification Number TY ECLH HSW, 8.0K, 3/4"NPT

Model SW-20 and SW K-factor Extended Coverage Ordinary Hazard Horizontal Sidewall Sprinklers (Standard Response) General Description

WFDE Series Waterflow Detector

WRENCH FLATS 1/2" NPT. 7/16" (11,1 mm) NOMINAL MAKE-IN CENTERLINE OF WATERWAY ESCUTCHEON PLATE SEATING SURFACE

special request FACTORY ASSEMBLED UPRIGHT WITH SCREW FIELD ASSEMBLED MODEL S2 SHIELD (SEE INSTALLATION SECTION) WRENCH FLATS *

Series LFII Residential Horizontal Sidewall Sprinklers 4.2 K-factor General Description

WRENCH FLATS 1/2" NPT. 7/16" (11,1 mm) NOMINAL MAKE-IN CENTERLINE OF WATERWAY ESCUTCHEON PLATE SEATING SURFACE

Series LFII Residential Flush Pendent Sprinklers 4.2 K-factor General Description

Sprinkler Identification Number (SIN) TY4234. Page 1 of 8 APRIL 2012 TFP Technical Services

Series LFII Residential Horizontal Sidewall Sprinklers 4.4 K-factor General Description

Series DS-1 Stainless Steel Dry-Type Sprinklers 5.6K Pendent, HSW, and Extended Coverage HSW Standard and Quick Response General Description

ESCUTCHEON PLATE SEATING 3/4" NPT SURFACE. 1-1/2" (38,1 mm) CROSS SECTION PENDENT RECESSED PENDENT

Page 1 of 8 DECEMBER 2018 TFP408. Worldwide Contacts.

Series RFII 5.6 K-factor. Flush II Concealed Pendent Sprinklers

Model WS Specific Application Window Sprinklers Horizontal and Pendent Vertical Sidewall 5.6 K-Factor General Description

Series ELO K-factor Upright and Pendent Sprinklers Standard Response, Standard Coverage General Description

5.6K Horizontal Sidewall Standard and Quick Response, Extended Coverage General Description. Model/Sprinkler Identification Numbers (SINs)

Model WS TM 5.6 K-factor Specific Application Window Sprinklers, Horizontal and Pendent Vertical Sidewall General Description

RAPID RESPONSE Series LFII Residential Sprinkler 4.4 K-factor Horizontal Sidewall, Dry Type Wet Pipe System General Description

RAPID RESPONSE Series LFII Residential Sprinklers 4.9 K-factor Recessed Pendent, Dry Type Wet Pipe and Dry Pipe Systems General Description

RAPID RESPONSE Series LFII Residential Sprinkler 4.4 K-factor Horizontal Sidewall, Dry Type Wet Pipe System General Description

Sprinkler Identification Numbers

Series LFII Residential Sprinklers Flat-Plate Concealed Pendent 4.9 K-Factor General Description

Series DS-1 Stainless Steel Dry-Type Sprinklers 5.6K Pendent, HSW, and Extended Coverage HSW Standard and Quick Response General Description

RAPID RESPONSE Series LFII Residential Sprinklers 4.9 K-factor Domed-Plate Concealed Pendent Wet Pipe and Dry Pipe Systems General Description

RAPID RESPONSE Series LFII Residential 4.9 K-factor Concealed Pendent Sprinkler Flat Plate, Wet Pipe and Dry Pipe Systems General Description

Sprinkler Identification Number (SIN)

Model WS Specific Application Window Sprinklers Horizontal and Pendent Vertical Sidewall 5.6 K-factor General Description

RAPID RESPONSE Series LFII Residential Sprinklers 4.9 K-factor Recessed Pendent, Dry Type Wet Pipe and Dry Pipe Systems General Description

RAPID RESPONSE Series LFII Residential Sprinklers 4.2 K-factor Flush Horizontal Sidewall Wet Pipe Systems

Model ESFR K-factor Pendent Sprinkler Early Suppression, Fast Response General Description. Sprinkler Identification Number (SIN)

5.6K Pendent, Upright, and Horizontal Sidewall Standard Response, Standard Coverage General Description. Model/Sprinkler Identification Numbers (SINs)

Series DS-1 Dry-Type Sprinklers 5.6K Pendent, Upright, and Horizontal Sidewall Quick Response, Standard Coverage General Description

Design Criteria. Installation

RAPID RESPONSE Series LFII Residential Sprinklers 4.9 K-factor Flat-Plate Concealed Pendent Wet Pipe and Dry Pipe Systems General Description

Model TY-FRFS, TY-FS Special, and TY-FS 57, 80, and 115 K-factor Upright and Pendent Flat Spray Sprinklers General Description

11.2K * Pendent Extended Coverage, Light and Ordinary Hazard General Description. Model/Sprinkler Identification Numbers (SINs) Technical Data

FIGURE 1 MODEL RFIII ECLH CONCEALED HSW SPRINKLER ASSEMBLY AND FEATURES. 5/16" (7,9 mm) MIN. 9/16" (14,3 mm) MAX.

RAVEN 5.6K Institutional Sprinklers Pendent and Horizontal Sidewall Quick Response, Standard and Extended Coverage General Description

Model ESFR-25 Early Suppression, Fast Response Pendent Sprinklers 25.2 K-factor General Description

Model/Sprinkler Identification Number (SIN) Technical Data

Model ESFR-17 Early Suppression, Fast Response Upright Sprinklers 16.8 K-factor General Description

Model TY-FRFS, TY-FS Special, and TY-FS Flat Spray Sprinklers, Upright and Pendent 57, 80, and 115 K-factor General Description

RAPID RESPONSE Series LFII Residential Sprinklers 4.2 K-factor Flush Pendent Wet Pipe and Dry Pipe Systems General Description

RAVEN 5.6K Institutional Sprinklers Pendent and Horizontal Sidewall Quick Response, Standard and Extended Coverage General Description

Technical Data. Installation

Model A Pipe Line Strainer 3, 4, 6, 8 & 10 Inch (DN80, DN100, DN150, DN200 & DN250) 175 psi (12,1 bar) General Description.

RAPID RESPONSE Series LFII Residential Sprinklers 4.4 K-factor Horizontal Sidewall, Dry Type Wet Pipe and Dry Pipe Systems

Model ESFR-17 Dry Type Pendent Sprinklers Early Suppression Fast Response 16.8 K-factor General Description

Model ESFR-17 Dry Type Pendent Sprinklers Early Suppression Fast Response 16.8 K-factor General Description

G3/8" DIN ISO 228 THREAD SHOULDER AND DUST CAP MATING SURFACE. STYLE H ESCUTCHEON (SEPARATELY ORDERED) 85 mm DIA. (3-3/8")

Residential Flush Horizontal Side-Wall Sprinkler Model HF-RES,K=4.2 (SIN / SS4423) (PTFE gasketed orifice seal design)

Model ESFR K-factor Dry Type Pendent Sprinklers Early Suppression, Fast Response General Description

SENJU SPRINKLER CO.,LTD. Residential Flush Pendent Sprinkler Model ZN-RES,K=4.2 (SIN / SS4421) (PTFE gasketed orifice seal design) General Description

Model CV-1FR Riser Check Valves 2 to 12 Inch (DN50 to DN300) General Description. Installation. Technical Data. Page 1 of 6 OCTOBER 2010 TFP950

UL LISTED. SPRINKLER HEADS IN STOCK: Pendent Upright Horizontal sidewall Concealed. RESPONSE Quick response Standard response

Model ESFR K-factor Dry Type Pendent Sprinklers Early Suppression, Fast Response General Description

MODEL: FA003U FA004U FA005P FA006P STANDARD SPRAY, STANDARD QUICK RESPONSE, 5 3 mm BULB TYPE, K5.6, 1/2" CONNECTING THREAD

Automatic Sprinklers

Transcription:

S P R I N K L E R S Y S T E M S M O N I T O R I N G WFD Series Waterflow Detector UL Models WFD20 WFD25 WFD30-2 WFD35 WFD40 WFD50 WFD60 WFD80 ULC/Canadian Models WFD20A WFD25A WFD30-2A WFD35A WFD40A WFD50A WFD60A WFD80A WFD40 Replacement Parts A3008-00 Retard Mechanism A77-01-02 Terminal lock 546-7000 Cover Tamper Switch Kit WFDW Cover Wrench WFDN4 Replacement gasket kit Product Overview New WFD30-2 models install in 2 hole sizes UL models are NEMA 4 rated Sealed retard mechanism assures that the retard is not contaminated by dust and dirt when the cover is removed Visual switch activation permits installer to accurately set retard under noisy conditions Rugged, dual SPDT switches are enclosed in a durable terminal block Accommodates up to 12 AWG wire 100% synchronization activates both alarm panel and local bell simultaneously System Sensor s WFD series is compatible with schedule 10 through 40 steel pipe, sizes 2 through 8, and can be mounted in a vertical or horizontal position. Robust Construction. The WFD series consists of a rugged, NEMA 4 rated enclosure. Designed for both indoor and outdoor use, the WFD series operates across a wide temperature range, from 32 F to 120 F. Reliable Performance. UL listed models are equipped with tamper resistant cover screws to prevent unauthorized entry. Inside, two sets of SPDT (Form C) synchronized switches are enclosed in a durable terminal block to assure reliable performance. False Alarm Immunity. The WFD series incorporates a mechanical retard feature, which minimizes the risk of false alarm due to pressure surges or air trapped in the sprinkler system. In addition, the mechanical retard s unique sealed design is immune to dust and other contaminants. Simplified Operation. The WFD series is designed to simplify installation. Two conduit openings permit easy attachment to the local alarm system. The retard mechanism and dual SPDT switches are field-replaceable. S739 CS169 7770-1209:140 167-93-E APPROVED 1W9A2.AH

Engineering Specifications Vane-type waterflow detectors shall be installed on system piping as designated on the drawing and/or as specified herein. Detectors shall mount on any clear pipe span of the appropriate nominal size, either a vertical upflow or horizontal run, at least 6 from any fittings which may change water direction, flow rate, or pipe diameter or no closer than 24 from a valve or drain. Detectors shall have a sensitivity in the range of 4 to 10 gallons per minute and a static pressure rating of 450 psi* for 2-8 pipes. The detector shall respond to waterflow in the specified direction after a preset time delay which is field adjustable. The delay mechanism shall be a sealed mechanical pneumatic unit with visual indication of actuation. The actuation mechanism shall include a polyethylene vane inserted through a hole in the pipe and connected by a mechanical linkage to the delay mechanism. Outputs shall consist of dual SPDT switches (Form C contacts). Two conduit entrances for standard fittings of commonly used electrical conduit shall be provided on the detectors. A grounding provision is provided. Unless noted, enclosures shall be NEMA 4 listed by Underwriters Laboratories Inc. All detectors shall be listed by Underwriters Laboratories Inc. for indoor or outdoor use. Standard Specifications Static Pressure Rating 450 PSI* Triggering Threshold andwidth (Flow Rate) 4 10 GPM Maximum Surge 18 Feet Per Second (FPS) Compatible Pipe: Steel water pipe, schedule 10 through 40 Contact Ratings Two sets of SPDT (Form C) 10.0 A, 1/2 HP @ 125/250 VAC 2.5 A @ 6/12/24 VDC Overall Dimensions Installed: 3.75 Conduit Entrances Two openings for 1 2 conduit. One open, one knockout type Operating Temperature Range 32ºF to 120ºF (0ºC to 49ºC) Enclosure Rating* NEMA 4 suitable for indoor/outdoor use Cover Tamper Switch Standard with ULC models Optional for UL models, part no. 546-7000 Shipping Weight WFD20: 4.2 lbs. WFD25: 4.3 lbs. WFD30-2: 4.5 lbs. WFD35: 4.7 lbs. WFD40: 5.2 lbs. WFD50: 6.3 lbs. WFD60: 6.8 lbs. WFD80: 7.5 lbs. T16-0010-XXX A Service Use Automatic Sprinkler: NFPA-13 One or Two Family Dwelling: NFPA 13D Residential Occupancies up to 4 Stories: NFPA 13R National Fire Alarm Code: NFPA-72 Warranty 3 Years U.S. Patent Numbers 3,845,259 4,782,333 5,213,205 CAUTION ROUTE WIRING AWAY FROM SHARP EDGES & COPONENTS SWITCH SCHEMATIC READY STATE SWITCH 1 SWITCH 2 NOTE: Common and connections will close when vane is deflected, i.e., when water is flowing. Dual switches permit applications to be combined on a single detector. 3.0 A A CONTACT RATINGS 125/250 VAC 24 VDC 10 AMPS 2.5 AMPS U bolt nut Pipe saddle 1.6 To nonsilenceable initiating zone of listed FACP WFD WFD end-of-line resistor Pipe Typical FACP Connection Plastic vane U bolt Width: See Table Model WFD20 WFD25 WFD30-2 WFD35 Width 4.6 4.6 5.2 5.7 Model WFD40 WFD50 WFD60 WFD80 Width 6.8 7.8 9.0 10.8 To power source compatible with bell Typical Local ell Connection local bell WFD switch assembly reak wire as shown for supervision of connection. DO NOT allow stripped wire leads to extend beyond switch housing. DO NOT loop wires. Ordering Information UL Model Numbers ULC/Canadian Model Numbers Pipe Size Hole Size WFD20 WFD20A 2 1 1 4 WFD25 WFD25A 2 1 2 1 1 4 WFD30-2 WFD30-2A 3 2 WFD35 WFD35A 3 1 2 1 1 4 WFD40 WFD40A 4 2 WFD50 WFD50A 5 2 WFD60* WFD60A 6 2 WFD80* WFD80A 8 2 *Maximum pressure rating 400 psi as approved by Factory Mutual. Part Number Description A3008-00 Retard mechanism A77-01-02 Terminal block 546-7000 Tamper proof switch kit WFDW Tamper proof wrench for cover WFDN4 Gasket kit System Sensor Sales and Service System Sensor Headquarters 3825 Ohio Avenue St. Charles, IL 60174 Ph: 800/SENSOR2 Fx: 630/377-6495 www.systemsensor.com System Sensor Canada Ph: 905.812.0767 Fx: 905.812.0771 System Sensor Europe Ph: 44.1403.891920 Fx: 44.1403.891921 System Sensor in China Ph: 86.29.8832.0119 Fx: 86.29.8832.5119 System Sensor in Singapore Ph: 65.6273.2230 Fx: 65.6273.2610 System Sensor Far East Ph: 85.22.191.9003 Fx: 85.22.736.6580 System Sensor Australia Ph: 613.54.281.142 Fx: 613.54.281.172 System Sensor India Ph: 91.124.237.1770 x.2700 Fx: 91.124.237.3118 System Sensor Russia Ph: 70.95.937.7982 Fx: 70.95.937.7983 2004 System Sensor. The company reserves the right to change product specifications without notice. A05-0180-009 10/04 1360

S P R I N K L E R S Y S T E M S M O N I T O R I N G OSY2 Supervisory Switch Models Available OSY2 OSY2A OS&Y Supervisory Switch OS&Y Supervisory Switch (ULC/Canadian) OSY2 Replacement Parts OSYRK Replacement Hardware Kit 546-7000 Cover Tamper Switch Kit S07-66-XX Tamper Screws for Cover WFDW Cover Wrench HEXW Replacement Hex Wrench Product Overview NEMA 3R rated enclosure User-friendly mounting bracket fits newer valve yokes Single side conduit entry does not require right angle fittings Adjustable length actuator eliminates the need for cutting the shaft Accommodates up to 12 AWG wire Three position switch monitors vandal and valve close signals Two SPDT contacts are enclosed in a durable terminal block for added strength 100% synchronization activates both alarm panel and local bell simultaneously System Sensor s OSY2 is used to monitor the open position of an Outside Screw and Yoke (OS&Y) type gate valve. Robust Construction. The OSY2 consists of a rugged housing, intended for indoor and outdoor use. When installed with the actuator in the vertical position, the OSY2 is NEMA 3R rated per UL. Application Flexibility. The OSY2 features a user-friendly mounting bracket and adjustable shaft to permit mounting to most OS&Y valves, ranging is size from 1 to 12. Its right angle design and wide bracket span provides maximum clearance for valve components, to accommodate troublesome valves. Removing the OSY2 s gate valve bracket allows the unit to monitor sidebracket style pressure reducing valves. Simplified Operation. Installation is made easier with the OSY2 s single side conduit entrance. y providing a direct conduit pathway to the electrical source, right angle fittings are not required. Installation is further simplified by the OSY2 s adjustable length actuator, which eliminates the need for cutting the shaft. Reliable Performance. The OSY2 is equipped with tamper resistant cover screws to prevent unauthorized entry. Inside, two sets of SPDT (Form C) synchronized switches are enclosed in a durable terminal black to assure reliable performance.

Engineering Specifications Model shall be model number OSY2 supervisory switch as manufactured by System Sensor. OSY2 shall be installed on each valve as designated on the drawings and/or as specified herein. Switches shall be mounted so as not to interfere with the normal operation of the valve and shall be adjusted to operate within two revolutions of the valve control or when the stem has moved no more than one-fifth of the distance from its normal position. The mechanism shall be contained in a weatherproof die cast metal housing, which shall provide a side entrance for 1 /2 conduit and incorporate the necessary facilities for attachment to the valve. A grounding provision is provided. The switch assembly shall include two switches each with a rated capacity of 10 Amp @ 125/250VAC and 2.5 Amp @ 24VDC. The cover shall contain tamperresistant screws for which a security wrench will be provided with each switch. The OSY2 shall be Underwriters Laboratories listed for indoor or outdoor use. The OSY2 shall be Factory Mutual, CSFM, and MEA approved. Standard Specifications Contact Ratings Two sets of SPDT (Form C) 10.0 A @ 125/250V AC 2.5 @ 6/12/24V DC Overall Switch Dimensions 5 3 /4 H x 3 1 /2 W x 3 1 /4 D (14.6cm x 8.9cm x 8.2cm) racket Span 2 1 /4 H x 6 3 /4 W x 1 D (5.7cm x 17.1cm x 2.5cm) Maximum Stem Extension 2 5 /8 (6.7 cm) Shipping Weight 2.8 lbs. (1.3 kg) Conduit Entrances One single side open for 1 /2 conduit OSY2 Mounting Operating Temperature Range 32 F to 120 F (0 C to 49 C) Note: The OSY2 will operate from 40 F to 120 F ( 40 C to 49 C); however UL does not test control valve supervisory switches below 32 F (0 C). Enclosure Rating UL indoor/outdoor NEMA 3R when mounted with the actuator vertical Cover Tamper Switch Standard with ULC model Optional for UL model, part no. 546-7000 Service Use Automatic Sprinkler: NFPA 13 One or Two Family Dwelling: NFPA 13D Residential Occupancies up to 4 stories: NFPA 13R National Fire Alarm code: NFPA 72 Warranty 3 years Electrical Connections for OSY2 Switch 1 Strip Gauge Top View A A Sup. Switch U.S. Patent Nos. 5,478,038; 5,213,205 Switch 2 Sup. Switch CONTACT RATINGS 125/250 VAC 24 VDC 10 AMPS 2.5 AMPS THE FOLLOWING ARE EXAMPLES OF ACCEPTALE POSITIONS: THE FOLLOWING POSITION IS NOT ACCEPTALE: to nonsilenceable initiating zone of listed FACP end-of-line resistor Typical FACP Connection ACTUATOR VERTICAL (DOWN) ACTUATOR HORIZONTAL ACTUATOR VERTICAL (POINTING UP) to power source compatible with bell local bell reak wire as shown for supervision of connection. DO NOT allow stripped wire leads to extend beyond switch housing. DO NOT loop wires. Ordering Information Model Number OSY2 OSY2A Typical Local ell Connection Description Outside Screw and Yoke valve supervisory switch Outside Screw and Yoke valve supervisory switch (ULC model Part Number Description OSYRK Replacement hardware kit (wrenches, screw pack and J-hooks) 546-7000 Cover tamper switch kit S07-66-XX Tamper screws for cover WFDW Replacement tamper proof wrench for cover HEXW Replacement hex wrench System Sensor Sales and Service System Sensor Headquarters 3825 Ohio Avenue St. Charles, IL 60174 Ph: 800/SENSOR2 Fx: 630/377-6495 Documents-on-Demand 800/736-7672 x3 www.systemsensor.com System Sensor Canada Ph: 905.812.0767 Fx: 905.812.0771 System Sensor Europe Ph: 44.1403.276500 Fx: 44.1403.276501 System Sensor in China Ph: 86.29.524.6253 Fx: 86.29.524.6259 System Sensor in Singapore Ph: 65.6273.2230 Fx: 65.6273.2610 System Sensor Far East Ph: 85.22.191.9003 Fx: 85.22.736.6580 System Sensor Australia Ph: 613.54.281.142 Fx: 613.54.281.172 System Sensor India Ph: 91.124.637.1770 x.2700 Fx: 91.124.637.3118 2002 System Sensor. The company reserves the right to change product specifications without notice. A05-0196-007 9/02 #1001

Worldwide Contacts www.tyco-fire.com Series TY-, 5.6 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage General Description The TYCO Series TY-, 5.6 K-factor, Upright (TY315) and Pendent (TY325) Sprinklers described in this data sheet are standard response, standard coverage, decorative 5 mm glass bulb type spray sprinklers designed for use in light, ordinary, or extra hazard, commercial occupancies such as banks, hotels, shopping malls, factories, refineries, and chemical plants. The recessed version of the Series TY- Pendent Sprinkler, where applicable, is intended for use in areas with a finished ceiling. This recessed pendent sprinkler uses one of the following: A two-piece Style 15 Recessed Escutcheon with recessed adjustment up to 5/8 inch (15,9 mm) from the flush pendent position. A two-piece Style 20 Recessed Escutcheon with recessed adjustment up to 1/2 inch (12,7 mm) from the flush pendent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Intermediate level versions of Series TY- Sprinklers are described in Technical Data Sheet TFP352. Sprinkler guards and shields are described in Technical Data Sheet TFP780. IMPORTANT Always refer to Technical Data Sheet TFP700 for the INSTALLER WARNING that provides cautions with respect to handling and installation of sprinkler systems and components. Improper handling and installation can permanently damage a sprinkler system or its components and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. NOTICE The TYCO Series TY- Sprinklers described herein must be installed and maintained in compliance with this document, as well as with the applicable standards of the National Fire Protection Association, in addition to the standards of any other authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintaining their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Sprinkler Identification Numbers (SINs) TY315...Upright 5.6K, 1/2 TY325...Pendent 5.6K, 1/2 Technical Data Approvals UL and C-UL Listed FM and VdS Approved CE Certified Maximum Working Pressure 175 psi (12.1 bar) 250 psi (17.2 bar)* * The maximum working pressure of 250 psi (17.2 bar) only applies to the listing by Underwriters Laboratories, Inc. (UL). Discharge Coefficient K = 5.6 GPM/psi 1/2 (80,6 LPM/bar 1/2 Temperature Ratings 135 F (57 C) 155 F (68 C) 175 F (79 C) 200 F (93 C) 286 F (141 C) 360 F (182 C) UL, C-UL, and VdS Approved only Finishes Sprinkler: Natural rass, Chrome Plated, Pure White (RAL 9010) and Signal White (RAL 9003). Recessed Escutcheon: White Coated, Chrome Plated, or rass Plated Physical Characteristics Frame... ronze utton....rass/copper Sealing Assembly...Stainless Steel w/teflon ulb...glass Compression Screw........ ronze Deflector.... ronze Page 1 of 4 JANUARY 2013 TFP152

TFP152 Page 2 of 4 Components: 1 - Frame 2 - utton 3 - Sealing Assembly 6* 5 4 2 3 1 2" (50,8 mm) * Temperature rating is 4 - ulb indicated on Deflector. 5 - Compression Screw 6 - Deflector* DEFLECTOR * 7/16" (11,1 mm) NOMINAL MAKE-IN Operation The glass bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and water to flow. Design Criteria ** ESCUTCHEON PLATE SEATING 2" (50,8 mm) Pipe thread connections per ISO 7-1 can be provided on special request. 1-3/8" (34,9 mm) ** ** DEFLECTOR * The TYCO Series TY-, 5.6 K-factor, Upright (TY315) and Pendent (TY325) Sprinklers are intended for fire protection systems designed in accordance with the standard installation rules recognized by the applicable Listing or Approval agency (e.g., UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of the FM Loss Prevention Data Sheets). Only the Style 15 or Style 20 Recessed Escutcheon, as applicable, is to be used for recessed pendent installations. 7/16" (11,1 mm) NOMINAL MAKE-IN FLATS 2-7/8" (73,0 mm) DIA. Installation STYLE 15 or 20 RECESSED ESCUTCHEON CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT FIGURE 1 SERIES TY- UPRIGHT (TY315) AND PENDENT (TY325) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH, STANDARD RESPONSE RECESS (USE ONLY END "A") FIGURE 2 W-TYPE 6 SPRINKLER RECESS PUSH IN TO ENSURE ENGAGEMENT WITH SPRINKLER ING AREA FIGURE 3 W-TYPE 7 RECESSED SPRINKLER The TYCO Series TY-, 5.6 K-factor, Upright (TY315) and Pendent (TY325) Sprinklers must be installed in accordance with this section. General Instructions Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135 F (57 C) to 3/32 inch (2,4 mm) for the 360 F (182 C) temperature ratings. A leak-tight 1/2 inch sprinkler joint should be obtained by applying a minimum-to-maximum torque of 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Higher levels of torque may distort the sprinkler inlet and cause leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the escutcheon plate by under- or over-tightening the sprinkler. Readjust the position of the sprinkler fitting to suit. Upright and Pendent Sprinklers The Series TY- Upright and Pendent Sprinklers must be installed in accordance with the following instructions. Step 1. Install pendent sprinklers in the pendent position; install upright sprinklers in the upright position. Step 2. With pipe-thread sealant applied to the pipe threads, handtighten the sprinkler into the sprinkler fitting.

TFP152 Page 3 of 4 Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Figure 2). With reference to Figure 1, apply the W-Type 6 Sprinkler Wrench to the wrench flats. Torque sprinklers 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Recessed Pendent Sprinklers The Series TY- Recessed Pendent Sprinklers must be installed in accordance with the following instructions. Step A. After installing the Style 15 or Style 20 Mounting Plate, as applicable, over the sprinkler threads and with pipe-thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Figure 3). With reference to Figure 1, apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Torque sprinklers 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Step C. After the ceiling is installed or the finish coat is applied, slide on the Style 15 or Style 20 Closure over the Series TY- Sprinkler and push the Closure over the Mounting Plate until its flange contacts the ceiling. Care and Maintenance The TYCO Series TY-, 5.6 K-factor, Upright (TY315) and Pendent (TY325) Sprinklers must be maintained and serviced in accordance with this section. efore closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection system from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay sprinkler operation in a fire situation. The owner must assure that the sprinklers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non-operation in the event of a fire or inadvertent operation may result. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or otherwise altered after leaving the factory. 3/8±5/16" (9,5±7,9 mm) FACE OF SPRINKLER FITTING 5/16±1/4" (7,9±6,4 mm) CLOSURE FACE OF SPRINKLER FITTING CLOSURE 2-7/8" DIA. (73,0 mm) 2-1/4" DIA. (57,2 mm) SERIES TY- PLATE 1/8" (3,2 mm) (12,7 mm) FLUSH 1-3/8" (34,9 mm) 7/8" (22,2 mm) FIGURE 5 SERIES TY- RECESSED PENDENT SPRINKLER ASSEMLY (TY325) WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid damage to the sprinklers - before, during, and after installation. Sprinklers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section.) Thereafter, annual inspections per NFPA 25 are required; however, instead of inspecting from the floor level, a 2-7/8" DIA. (73,0 mm) 2-1/4" DIA. (57,2 mm) SERIES TY- PLATE 1/8" (3,2 mm) 5/8" (15,9 mm) FLUSH 1-3/8" (34,9 mm) 3/4" (19,1 mm) FIGURE 4 SERIES TY- RECESSED PENDENT SPRINKLER ASSEMLY (TY325) WITH TWO-PIECE 5/8 INCH TOTAL ADJUSTMENT STYLE 15 RECESSED ESCUTCHEON random sampling of close-up visual inspections should be made. The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. Contact the installing contractor or sprinkler manufacturer regarding any questions. Automatic sprinklers are recommended to be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes.

TFP152 Page 4 of 4 P/N* 77 XXX X XXX SIN SPRINKLER FINISH 1 NATURAL RASS TEMPERATURE RATINGS 135 135 F (57 C) 570 5.6K UPRIGHT (1/2 ) TY315 4 SIGNAL WHITE (RAL 9003) 155 155 F (68 C) 571 5.6K PENDENT (1/2 ) TY325 3 PURE WHITE (RAL 9010)** 175 175 F (79 C) * Use suffix I for ISO 7-1 connection; for example, 77-570-4-175-I 9 CHROME PLATED 200 200 F (93 C) ** Eastern Hemisphere sales only 286 286 F (141 C) 360 360 F (182 C) Ordering Procedure Contact your local distributor for availability. When placing an order, indicate the full product name and Part Number (P/N). Sprinkler Assemblies with Thread Connections Specify: Series TY- (SIN), K=5.6, (Upright or Pendent) Sprinkler Standard Response, (specify) temperature rating, (specify) finish, P/N (Table A) Recessed Escutcheon Specify: Style 15 Recessed Escutcheon with (specify*) finish, P/N (specify*) Specify: Style 20 Recessed Escutcheon with (specify*) finish, P/N (specify*) * Refer to Technical Data Sheet TFP770. Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 TALE A SERIES TY- UPRIGHT AND PENDENT SPRINKLERS PART NUMER SELECTION GLOAL HEADQUARTERS 1400 Pennbrook Parkway, Lansdale, PA 19446 Telephone +1-215-362-0700 Copyright 2013 Tyco Fire Products, LP. All rights reserved. TEFLON is trademark of The DuPont Corporation.

Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 Customer Service/Sales: Tel: (215) 362-0700 / (800) 523-6512 Fax: (215) 362-5385 Series TY- 5.6 K-factor Horizontal and Vertical Sidewall Sprinklers Standard Response, Standard Coverage General Description TheSeriesTY-,5.6K-factor,Horizontal and Vertical Sidewall Sprinklers described in this data sheet are standard response - standard coverage, decorative 5 mm glass bulb type spray sprinklers designed for use in light and ordinary hazard, commercial occupancies such as banks, hotels, shopping malls, etc. They are designed for installation along a wall or the side of a beam and just beneath a smooth ceiling. Sidewall sprinklers are commonly used instead of pendent or upright sprinklers due to aesthetics or building construction considerations, where piping across the ceiling is not desirable. The recessed version of the Series TY- Horizontal Sidewall Sprinkler is intended for use in areas with a finished wall. It uses a two-piece Style 10 Recessed Escutcheon. The Recessed Escutcheon provides 1/2 inch (12,7 mm) of recessed adjustment or up to 3/4 inch (19,1 mm) of total adjustment from the flush sidewall position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe nipples to the sprinklers must be cut. IMPORTANT Always refer to Technical Data Sheet TFP700 for the INSTALLER WARNING that provides cautions with respect to handling and installation of sprinkler systems and components. Improper handling and installation can permanently damage a sprinkler system or its components and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Corrosion resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be obtained when exposed to corrosive atmospheres. Although corrosion resistant coated sprinklers have passed the standard corrosion tests of the applicable approval agencies, the testing is not representative of all possible corrosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suitability of these coatings for any given corrosive environment. The effects of ambient temperature, concentration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. WARNINGS The Series TY- Sprinklers described herein must be installed and maintained in compliance with this document, as well as with the applicable standards of the National Fire Protection Association, in addition to the standards of any other authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintaining their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Model/Sprinkler Identification Numbers TY3351 - TY3451 - Horizontal Vertical Technical Data Approvals UL and C-UL Listed. FM, LPC, and NYC Approved. (Refer to Table A for complete approval information including corrosion resistant status) Maximum Working Pressure RefertoTable. Discharge Coefficient K=5.6GPM/psi 1/2 (80,6 LPM/bar 1/2 ) Temperature Ratings RefertoTableA. Finishes Sprinkler: Refer to Table A. Recessed Escutcheon: White Coated, Chrome Plated, and rass Plated. Page 1 of 6 APRIL, 2006 TFP161

Page2of6 TFP161 SPRINKLER FINISH (See Note 10) K TYPE TEMP. UL LIQUID NATURAL RASS CHROME PLATED WHITE*** POLYESTER LEAD COATED WAX COATED WAX OVER LEAD COATED 5.6 HORIZ. SIDEWALL (TY3351) RECESSED HORIZ. SIDEWALL (TY3351)* Figure 3 135 F/57 C 155 F/68 C 175 F/79 C 200 F/93 C 286 F/141 C 360 F/182 C 135 F/57 C 155 F/68 C 175 F/79 C 200 F/93 C Orange Red Yellow Green lue Mauve Orange Red Yellow Green 1, 2, 3, 4, 9 1, 2, 4, 9 1, 2, 3, 9 1, 2, 3, 9 1, 2, 9 1, 2, 3, 9 1, 2, 3, 9 1, 2, 3, 9 1**, 2**, 3**, 9** 1**, 2**, 3**, 9** N/A N/A 5.6 VERTICAL SIDEWALL (TY3451) Installed Pendent or Upright 135 F/57 C 155 F/68 C 175 F/79 C 200 F/93 C 286 F/141 C 360 F/182 C Orange Red Yellow Green lue Mauve 4, 5, 6, 7, 8, 9 4, 5, 6, 8, 9 5, 6, 7, 9 5, 6, 7, 9 5, 6, 7, 9 5**, 6**, 7**, 9** 5**, 6**, 7**, 9** N/A NOTES: 1. Listed by Underwriters Laboratories, Inc. (UL) for use in Light and Ordinary Hazard Occupancies at a 4 to 12 inch (100 to 300 mm) top of deflector to ceiling distance. 2. Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL) for use in Light and Ordinary Hazard Occupancies at a 4 to 12 inch (100 to 300 mm) top of deflector to ceiling distance. 3. Approved by Factory Mutual Research Corporation (FM) for use in Light Hazard Occupancies at a 4 to 12 inch (100 to 300 mm) top of deflector to ceiling distance. 4. Approved by the Loss Prevention Certification oard (LPC Ref. No. 094a/05 & 007k/03) at a 4 to 6 inch (100 to 150 mm) deflector to ceiling distance. 5. Listed by Underwriters Laboratories, Inc. (UL) for use in Light and Ordinary Hazard Occupancies. 6. Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL:) for use in Light and Ordinary Hazard Occupancies. 7. Approved by Factory Mutual Research Corporation (FM) for use in Light Hazard Occupancies. 8. Approved by the Loss Prevention Certification oard (LPC Ref. No. 094a/05 & 007k/03). 9. Approved by the City of New York under MEA 354-01-E. 10. Where Polyester Coated, Lead Coated, Wax Coated, and Wax over Lead Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion Resistant Sprinklers. Where Lead Coated, Wax Coated, and Wax over Lead Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as Corrosion Resistant Sprinklers. * Installed with Style 10 ( ) 3/4" Total Adjustment Recessed Escutcheon. ** 150 F/66 C Maximum Ceiling Temperature. *** Frame and deflector only. Listings and approvals apply to color (Special Order). TALE A LAORATORY LISTINGS AND APPROVALS Physical Characteristics Frame............. ronze utton......... rass/copper Sealing Assembly............... eryllium Nickel w/teflon ulb............... Glass Compression Screw..... ronze HSW Deflector........ ronze VSW Deflector........ Copper Patents U.S.A. 5,810,263 Operation The glass ulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass ulb, allowing the sprinkler to activate and water to flow. Design Criteria The Series TY- Horizontal and Vertical Sidewall Sprinklers are intended for fire protection systems designed in accordance with the standard installation rules recognized by the applicable Listing or Approval agency (e.g., UL Listing is based on the requirements of NFPA 13, and FM Approval is based ontherequirementsoffm slossprevention Data Sheets). Only the Style 10 Recessed Escutcheon is to be used for recessed horizontal installations. DuPont Registered Trademark

TFP161 Page 3 of 6 SPRINKLER FINISH K TYPE NATURAL RASS CHROME PLATED WHITE POLYESTER LEAD COATED WAX COATED WAX OVER LEAD COATED 5.6 HORIZONTAL SIDEWALL (TY3351) RECESSED HORIZ. SIDEWALL (TY3351) VERTICAL SIDEWALL (TY3451) 250 PSI (17,2 AR) OR 175 PSI (12,1 AR) (SEE NOTE 1) 175 PSI (12,1 AR) 175 PSI (12,1 AR) N/A NOTES: 1. The maximum working pressure of 250 psi (17,2 bar) only applies to the Listing by Underwriters Laboratories, Inc. (UL); the Listing by Underwriters Laboratories, Inc. for use in Canada (C-UL); and, the Approval by the City of New York. TALE, MAXIMUM WORKING PRESSURE Installation The Series TY- Sprinklers must be installed in accordance with the following instructions: NOTES Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135 F/57 C to 3/32 inch (2,4 mm) for the 360 F/182 C temperature ratings. A leak tight 1/2 inch sprinkler joint should be obtained with a torque of 7 to 14 ft.lbs. (9,5 to 19,0 Nm). A maximum of 21 ft. lbs. (28,5 Nm) of torque may be used to install sprinklers with 1/2 connections. Higher levels of torque may distort the sprinkler inlet and cause leakage or impairment of the sprinkler. Do not attempt to make-up for insufficient adjustment in the escutcheon plate by under- or over-tightening the sprinkler. Readjust the position of the sprinkler fitting to suit. The Series TY- Horizontal and Vertical Sidewall Sprinklers must be installed in accordance with the following instructions. Step 1. Horizontal sidewall sprinklers are to be installed in the horizontal position with their centerline of waterway perpendicular to the back wall and parallel to the ceiling. The word TOP on the Deflector is to face towards the ceiling. Vertical sidewall sprinklers are to be installed in the pendent or upright position with the arrow on the Deflector pointing away from the wall. * Temperature rating is indicated on deflector or adjacent to orifice seat on frame. **Pipe thread connections per ISO 7/1 can be provided on special request. 1-Frame 2 - utton 3 - Sealing Assembly 4-ulb 5 - Compression Screw 6-Deflector 1-13/16" (46,0 mm) DEFLECTOR HAT 2-7/8" DIA. (73,0 mm) 6 * 9/16" (14,3 mm) CENTERLINE OF SPRINKLER WATERWAY STYLE 10 RECESSED ESCUTCHEON FIGURE 1 5.6 K-FACTOR STANDARD RESPONSE SERIES TY- HORIZONTAL SIDEWALL (TY3351) SPRINKLERS 5 4 7/16" (11,1 mm) NOMINAL MAKE-IN 1- (38,1 mm) 2 FLATS 2-3/16" (55,6 mm) 3 1 ** ESCUTCHEON PLATE SEATING

Page4of6 TFP161 Step 2. With pipe thread sealant applied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Ref. Figure 4), except that an 8 or 10 inch adjustable Crescent wrench is to be used for wax coated sprinklers. With reference to Figure 1 or 2, the W-Type 6 Sprinkler Wrench or the Crescent wrench, as applicable, is to be applied to the wrench flats. When installing wax coated sprinklers with the adjustable Crescent wrench, additional care needs to be exercised to prevent damage to the wax coating on the sprinkler wrench flats or frame arms and, consequently, exposure of bare metal to the corrosive environment. The jaws of the wrench should be opened sufficiently wide to pass over the wrench flats without damaging the wax coating. efore wrench tightening the sprinkler, the jaws of the wrench are to be adjusted to just contact the sprinkler wrench flats. After wrench tightening the sprinkler, loosen the wrench jaws before removing the wrench. After installation, the sprinkler wrench flats and frame arms must be inspected and the wax coating retouched (repaired) whenever the coating has been damaged and bare metal is exposed. The wax coating on the wrench flats can be retouched by gently applying a heated 1/8 inch diameter steel rod to the areas of wax that have been damaged, to smooth it back over areas where bare metal is exposed. NOTES Only retouching of the wax coating applied to the wrench flats and frame arms is permitted, and the retouching is to be performed only at the time of the initial sprinkler installation. The steel rod should be heated only to the point at which it can begin to melt the wax, and appropriate precautions need to be taken, when handling the heated rod, in order to prevent the installer from being burned. The Series TY- Recessed Horizontal Sidewall Sprinklers must be installed in accordance with the following instructions. Step A. Recessed horizontal sidewall sprinklers are to be installed in the horizontal position with their centerline of waterway perpendicular to the back wall and parallel to the ceiling. The word TOP on the Deflector is to face towards the ceiling. Step. After installing the Style 10 Mounting Plate over the sprinkler ESCUTCHEON PLATE SEATING 2-3/16" (55,6 mm) 1- (38,1 mm) 1-Frame 2 - utton ** SHOWN PENDENT 3 - Sealing Assembly 7/16" (11,1 mm) NOMINAL MAKE-IN FLATS FIGURE 2 5.6 K-FACTOR STANDARD RESPONSE SERIES TY- VERTICAL SIDEWALL (TY3451) SPRINKLERS threads, hand tighten the sprinkler into the sprinkler fitting. Step C. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Ref. Figure 5). With reference to Figure 1, the W-Type 7 Recessed Sprinkler Wrench is to be applied to the sprinkler wrench flats. Step D. After the ceiling has been installed or the finish coat has been applied, slide on the Style 10 Closure over the Series TY- Sprinkler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. ARROW MUST POINT AWAY FROM AND E PERPENDICULAR TO THE ACK WALL SHOWN UPRIGHT 4-ulb 5 - Compression Screw 2-3/16" (55,6 mm) CROSS SECTION 6-Deflector 7- Ejection Spring * Temperature rating is indicated on deflector or adjacent to orifice seat on frame. **Pipe thread connections per ISO 7/1 can be provided on special request. 7 * 6 5 4 2 3 1

TFP161 Page 5 of 6 SERIES TY- CLOSURE 5/8±1/4" (15,9±6,4 mm) FACE OF SPRINKLER FITTING 2-7/8" DIA. (73,0 mm) 2-1/4" DIA. (57,2 mm) RECESS (END "A" USED FOR MODELS) FIGURE 4 W-TYPE 6 SPRINKLER RECESS PLATE 1-1/4" (31,8 mm) 3/4" (19,1 mm) 1/8" (3,2 mm) 3/4" (19,1 mm) 1/4" (6,4 mm) FIGURE 3 SERIES TY- RECESSED HORIZONTAL SIDEWALL SPRINKLER WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON PUSH IN TO ENSURE ENGAGEMENT WITH SPRINKLER ING AREA FIGURE 5 W-TYPE 7 RECESSED SPRINKLER Care and Maintenance The Series TY- Sprinklers must be maintained and serviced in accordance with the following instructions: NOTES efore closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shut down the affected fire protection system must be obtained from the proper authorities and all personnel who may be affected by this action must be notified. The owner must assure that the sprinklers are not used for hanging of any objects; otherwise, non-operation in the event of a fire or inadvertent operation may result. Absence of an escutcheon, which is used to cover a clearance hole, may delay the time to sprinkler operation in a fire situation. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be be painted, plated, coated or otherwise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid damage to the sprinklers - before, during, and after installation. Sprinklers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). Frequent visual inspections are recommendedtobeinitiallyperformedfor corrosion resistant coated sprinklers, after the installation has been completed, to verify the integrity of the corrosion resistant coating. Thereafter, annual inspections per NFPA 25 should suffice; however, instead of inspecting from the floor level, a random sampling of close-up visual inspections should be made, so as to better determine the exact sprinkler condition and the long term integrity of the corrosion resistant coating, as it may be affected by the corrosive conditions present. The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The installing contractor or sprinkler manufacturer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes.

Page6of6 TFP161 P/N 57 XXX X XXX MODEL/SIN SPRINKLER TEMPERATURE RATING 578 HORIZONTAL SIDEWALL TY3351 1 NATURAL RASS 135 135 F/57 C 575 VERTICAL SIDEWALL TY3451 4 WHITE POLYESTER 155 155 F/68 C 3 WHITE (RAL9010)* 175 175 F/79 C 9 CHROME PLATED 200 200 F/93 C 7 LEAD COATED 6 WAX COATED 286 F/141 C MAX. 286 360 286 F/141 C 360 F/182 C 8 WAX OVER LEAD 286 F/141 C MAX. * Eastern Hemisphere sales only. TALE C PART NUMER SELECTION SERIES TY- HORIZONTAL AND VERTICAL SIDEWALL SPRINKLERS Limited Warranty Products manufactured by Tyco Fire & uilding Products (TFP) are warranted solely to the original uyer for ten (10) years against defects in material and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFP. No warranty is given for products or components manufactured by companies not affiliated by ownership with TFP or for products and components which have been subject to misuse, improper installation, corrosion, or which have not been installed, maintained, modified or repaired in accordance with applicable Standards of the National Fire Protection Association, and/or the standards of any other Authorities Having Jurisdiction. Materials found by TFP to be defective shall be either repaired or replaced, at TFP s sole option. TFP neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. TFP shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by uyer or uyer s representatives. In no event shall TFP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential damages, including but not limited to labor charges, regardless of whether TFP was informed about the possibility of such damages, and in no event shall TFP s liability exceed an amount equal to the sales price. Theforegoingwarrantyismadeinlieu of any and all other warranties, express or implied, including warranties of merchantability and fitness for a particular purpose. This limited warranty sets forth the exclusive remedy for claims based on failure of or defect in products, materials or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full extent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Ordering Procedure When placing an order, indicate the full product name. Refer to the Price List for complete listing of Part Numbers. Contact your local distributor for availability. Sprinkler Assemblies with Thread Connections: Specify: (Specify Model/SIN), Standard Response, (specify K-factor), (specify temperature rating), Series TY- (specify Horizontal Sidewall or Vertical Sidewall) Sprinkler with (specify type of finish or coating), P/N (specify from Table C). Recessed Escutcheon: Specify: Style 10 Recessed Escutcheon with (specify*) finish, P/N (specify*). * Refer to Technical Data Sheet TFP770. Sprinkler Wrench: Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387. Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001. TYCO FIRE & UILDING PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446

Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 Customer Service/Sales: Tel: (215) 362-0700 / (800) 523-6512 Fax: (215) 362-5385 Series TY-L 5.6 and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage General Description IMPORTANT Always refer to Technical Data Sheet TFP700 for the INSTALLER WARNING that provides cautions with respect to handling and installation of sprinkler systems and components. Improper handling and installation can permanently damage a sprinkler system or its components and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. The Series TY-L, 5.6 and 8.0 K-factor, Upright and Pendent Sprinklers described in this data sheet are standard response - standard coverage, solder type spray sprinklers designed for use in light, ordinary, and extra hazard, commercial occupancies such as banks, hotels, shopping malls, factories, refineries, chemical plants, etc. The recessed version of the Series TY-L Pendent Sprinkler, where applicable, is intended for use in areas with a finished ceiling. It uses a two-piece Style 20 (1/2 inch ) or Style 30 (3/4 inch ) Recessed Escutcheon. The Recessed Escutcheon provides 1/4 inch (6,4 mm) of recessed adjustment or up to 1/2 inch (12,7 mm) of total adjustment from the flush pendent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Corrosion resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be obtained when exposed to corrosive atmospheres. Although corrosion resistant coated sprinklers have passed the standard corrosion tests of the applicable approval agencies, the testing is not representative of all possible corrosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suitability of these coatings for any given corrosive environment. The effects of ambient temperature, concentration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. An intermediate level version of the Series TY-L Pendent Sprinkler can be obtained by utilizing the Series TY-L Pendent Sprinkler in combination with the Model S Shield. WARNINGS The Series TY-L Sprinklers described herein must be installed and maintained in compliance with this document, as well as with the applicable standards of the National Fire Protection Association, in addition to the standards of any other authorities having jurisdiction. Failuretodosomay impair the performance of these devices. The owner is responsible for maintaining their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Model/Sprinkler Identification Numbers TY3111 - Upright 5.6K, TY3211 - Pendent 5.6K, TY4111 - Upright 8.0K, 3/4" TY4211 - Pendent 8.0K, 3/4" TY4811 - Upright 8.0K, TY4911 - Pendent 8.0K, TY3111 is a redesignation for S1800 and G3111. TY3211 is a redesignation for S1801 and G3112. TY4111 is a redesignation for S1810 and G3101. TY4211 is a redesignation for S1811 and G3102. TY4811 is a redesignation for S1805. TY4911 is a redesignation for S1806 Page 1 of 8 JULY, 2004 TFP110

Page2of8 TFP110 FLANGES ESCUTCHEON PLATE SEATING STYLE 20 RECESSED ESCUTCHEON 1 7/16" (11,1 mm) NOMINAL MAKE-IN 2-5/8" (66,7 mm) 2" (50,8 mm) 2-5/8" (66,7 mm) AREA 3 2 4 5 6 2-7/8" (73,0 mm) DIA. 7 UPRIGHT PENDENT RECESSED PENDENT CROSS SECTION 1-Frame 2-Sealing utton 3 - Ejection Spring 4-Fusible Element 5-Strut 6-Hook 7-Deflector * Temperature rating is indicated on deflector. **Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 1 STANDARD RESPONSE SERIES TY-L UPRIGHT (TY3111) AND PENDENT (TY3211) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH FLANGES 3/4" ESCUTCHEON PLATE SEATING STYLE 30 RECESSED ESCUTCHEON 1 2-11/16" (68,3 mm) AREA 2 (12,7 mm) NOMINAL MAKE-IN 2" (50,8 mm) 2-11/16" (68,3 mm) 3 4 5 6 2-7/8" (73,0 mm) DIA. 7 UPRIGHT PENDENT RECESSED PENDENT CROSS SECTION 1-Frame 2-Sealing utton 3-Ejection Spring 4-Fusible Element 5-Strut 6-Hook 7 - Deflector * Temperature rating is indicated on deflector. **Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 2 STANDARD RESPONSE SERIES TY-L UPRIGHT (TY4111) AND PENDENT (TY4211) SPRINKLERS 8.0 K-FACTOR, 3/4 INCH

TFP110 Page 3 of 8 FLANGES ESCUTCHEON PLATE SEATING STYLE 20 RECESSED ESCUTCHEON 1 7/16" (11,1 mm) NOMINAL MAKE-IN 2-5/8" (66,7 mm) 2" (50,8 mm) 2-5/8" (66,7 mm) AREA 3 2 4 5 6 2-7/8" (73,0 mm) DIA. 7 UPRIGHT PENDENT RECESSED PENDENT CROSS SECTION 1-Frame 2-Sealing utton 3 - Ejection Spring 4-Fusible Element 5-Strut 6-Hook 7-Deflector * Temperature rating is indicated on deflector. **Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 3 STANDARD RESPONSE SERIES TY-L UPRIGHT (TY4811) AND PENDENT (TY4911) SPRINKLERS 8.0 K-FACTOR, 1/2 INCH Technical Data Approvals UL and C-UL Listed. FM, and LPC Approved. (Refer to Table A for complete approval information including corrosion resistant status.) Maximum Working Pressure 175 psi (12,1 bar) Discharge Coefficient K=5.6GPM/psi 1/2 (80,6 LPM/bar 1/2 ) K=8.0GPM/psi 1/2 (115,2 LPM/bar 1/2 ) Temperature Ratings RefertoTableA Finishes Sprinkler: Refer to Table A Recessed Escutcheon: White Coated, Chrome Plated, or rass Plated Physical Characteristics Frame.............. rass Sealing utton.. ronze w/teflon Ejection Spring.... Stainless Steel Fusible Element... Solder, Copper............ Stainless Steel Strut.............. Monel Hook......... ronze/monel Deflector........... ronze DuPont Registered Trademark Operation A copper tube sealed by two stainless steel balls holds a fusible alloy. When the rated temperature is reached, the alloy melts, the balls are forced toward each other releasing the tension mechanism, allowing the sprinkler to operate. Design Criteria The Series TY-L Pendent and Upright Sprinklers are intended for fire protection systems designed in accordance with the standard installation rules recognized by the applicable Listing or Approval agency (e.g., UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM s Loss Prevention Data Sheets). Only the Style 20 or 30 Recessed Escutcheon, as applicable, is to be used for recessed pendent installations. Installation The Series TY-L Sprinklers must be installed in accordance with the following instructions: NOTES A leak tight 1/2 inch sprinkler joint should be obtained with a torque of 7 to 14 ft.lbs. (9,5 to 19,0 Nm). A maximum of 21 ft. lbs. (28,5 Nm) of torque may be used to install sprinklers with 1/2 connections. A leak tight 3/4 inch sprinkler joint should be obtained with a torque of 10 to 20 ft.lbs. (13,4 to 26,8 Nm). A maximum of 30 ft.lbs. (40,7 Nm) of torque is to be used to install sprinklers with 3/4 connections. Higher levels of torque may distort the sprinkler inlet and cause leakage or impairment of the sprinkler. Do not attempt to make-up for insufficient adjustment in the escutcheon plate by under- or over-tightening the sprinkler. Readjust the position of the sprinkler fitting to suit. The Series TY-L Pendent and Upright Sprinklers must be installed in accordance with the following instructions. Step 1. Pendent sprinklers are to be installed in the pendent position, and upright sprinklers are to be installed in the upright position. Step 2. With pipe thread sealant applied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting.