Water Detection Controllers

Similar documents
WD-CS. Water leak detection cable. Technical Overview. Features. Page 1. Data Sheet Ref: Issue: 5.1.

Water Leak Detector - Four Zone with open/short-circuit detection. Product overview

GL-CO-RFG Channel Gas Leak Alarm System

READ AND SAVE THESE INSTRUCTIONS

RE-PR3-E-27 3-Phase Panel Mount 27kW

AquiTron. AT-LDM Liquid Detection Module INSTALLATION INSTRUCTIONS

EXTINGUISHING AGENT RELEASE MODULE

02/11/2015

INSTRUCTION MANUAL A105NAPPX & AL105NAPPX APPELLO Alarm Tone and Voice Annunciation Sounder

Pioneer-R16 Gas Monitor Operator s Manual

Oxygen (O2) Single-Point Gas Detection System

RH & T Sensors & Humidistats. RH-DT Duct Mount RH & T Sensors. Description

Analog Room Pressure Monitor RPC Series

Power Supply Display Module PSDM. Installation and Operation Manual

Installation, Operating and Maintenance Manual

Two-Channel Gas Controller

New Silent Alert Fire Safe System

PTE0705 Electric Fence Monitor

Section 1: General Description. Section 2: Features. Section 3: Operation. CM-RQE70 PIR REQUEST TO EXIT DETECTOR Installation Instructions.

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

CM-RQE70 PIR REQUEST TO EXIT DETECTOR

INSTRUCTION MANUAL A121APPX, AL121APPX & MV121 APPELLO Alarm Tone and Voice Annunciation Sounder

INSTRUCTION MANUAL A105NAPPX & AL105NAPPX APPELLO Alarm Tone and Voice Annunciation Sounder

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV

INSTALLATION INSTRUCTIONS

02/11/2015

THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16

CM-RQE70A PIR REQUEST TO EXIT DETECTOR

SINGLE CHANNEL SYSTEM TWO CHANNEL SYSTEM

tcm100, tcm101 Series Temperature Control Modules and PTS100, PTS100/3 Pipe Temperature Sensors Operations Manual

MODEL KP-200 VANDAL RESISTANT & WEATHERPROOF FLUSH MOUNT DIGITAL KEYPAD DESIGNED FOR ACCESS CONTROL APPLICATIONS

TTSIM-1A. TraceTek Sensor Interface Module with Relay. Installation/Operation Instructions. Installation Items (not supplied) Tools Required.

Carbon Monoxide Transmitter

/8 DIN Level Indicator

Flostop TS D7E and A8E. Operation Manual

Door Release Power Supply

Process Alarm Module RTA 421

ANNUNCIATOR INSTRUMENTS Model PD141AFO Instruction Manual

SYSTEM MANUAL FT1-SB. Single Zone Fire Alarm System

Touch Screen Thermostat. MTSC/SUPER/CO2, MTSC24/SUPER/CO2 Series. MTS/SUPER/CO2, MTS24/SUPER/CO2 Series. Owner s manual and technician settings

TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS

PERTRONIC INDUSTRIES LTD F4-RMAX Installation Note

Installation and user manual for the CF5000, MF5000 and FXP5000 range of fire panels

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

Temperature Controllers

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels

CaterSense 03 & ATSC-02-xx

LD1000 ARCHITECT AND ENGINEER SPECIFICATIONS. RLE TECHNOLOGIES Rev

Technical Manual. Level Alarm Unit CARLA & WIDS

Multi-Gas-Controller MGC2

TECHNICAL DATA SHEET CONVENTIONAL FIRE ALARM SYSTEMS Conventional Fire Alarm Control Panel

Operating Instructions. For. Alarm Control Module. Model SSR 500

UPON COMMENCMENT OF INSTALLATION IT IS OF PARAMOUNT IMPORTANCE THAT THE STEP BY STEP GUIDE (INCLUDED) IS FOLLOWED COMPLETELY

DPB52. True RMS 3-Phase, Multifunction monitoring relay. Benefits. Description

Model A1600 Series Annunciator

INTRODUCTION / TABLE OF CONTENTS

FIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module

DH100ACDCI Ionization Air Duct Smoke Detector

RM2S 2 module housing (sequence and phase-failure/asymmetry voltages)

Analox 1000 Series. User Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK

Tempco PCT-3000 Series Temperature Control Console with Relay Output for Heating or Cooling Applications

Gasflag. Single Channel Control Panel Alarm Only Apparatus. Installation, operating and maintenance instructions, M07225.

INSTALLATION INSTRUCTIONS

MODEL DESCRIPTION PAGE

0-2 m/s Lo Alarm 0-6 m/s Hi Alarm Signal Stregth EASZ-12 Doppler Flow Switch Measuring Flow Worldwide

FMR Installation Instructions. Addressable Fire System Controller

Motorised Infrared Optical Beam Smoke Detector. User Guide

WaterLeakStop Manual. Detection and Management of Water Leaks WLS-1

1200-HCM DIN RAIL MOUNTING FIRE SYSTEM MODULE Fire Detection & Extinguishant Control A R T PATOL LIMITED SUPPLY FAULT SOUNDER

GasSens. Self Checking Gas Sensors. Modular Gas Detector... Gas & Range Availability

Model OEM-2 INSTRUCTIONS FOR USE

Motorised Infrared Optical Beam Smoke Detector. User Guide

10yr O2NE & Safe-Ox. User Manual

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

Silent Alert Fire Safe System

Excel-EN Conventional Fire Control Panel

Warranty Registration

isopv425 and AGH420 Ground Fault Detector for Ungrounded Solar Arrays < 100 kw And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

Sensepoint XCL Fixed Gas Detector

VA301C CONTROLLER WITH BACnet OPTION

DH100ACDCI Ionization Air Duct Smoke Detector

Superdew 3. Hygrometer. Operating Instructions

Flopurge TS. Operation Manual

ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A

IMPORTANT. PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times!

Tempco Part Number PCT30006 Temperature Control Enclosure with Relay Output for Tote Tank Heating Applications

VERTEX VT10 SERIES PID OPERATION MANUAL MICROPROCESSOR BASED PID CONTROLLER

Series DCT1000DC Dust Collector Timer Controller Specifications Installation and Operating Instructions

X10 Mini, Midi & Maxi

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

ABLOY DA460 SWING DOOR OPERATOR. Installation and commissioning manual

Pakton Technologies Pty Ltd ABN Ferrier Road, Narangba Qld 4504

enproteko.com Specifications Ratings Item voltage to 24 VAC 5/6 Hz 24 VAC 5/6 Hz or 24 VDC Allowable voltage Characteristics 85% to 11% of power suppl

Model 17A00 Expansion Enclosure

LEAKMONITOR MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND USER OPERATION MANUAL

Wiring Instructions for the 2900 Series FIREGUARD Combination Door Closer-Holder and Releasing Device with Integral Smoke Detector

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

C-Bus Four Channel General Input Unit Installation Instructions

Occupancy Sensor LS Descriptions. Product Profile. Technical Specifications

Line Isolation Monitor (LIM) LIM2000plus

Transcription:

Page 1 of 5 Water Detection Controllers Features: Benefit: LED Status of leak status VFC output Audible alarm Auto or manual reset alarm output Uses an isolated AC signal which prevents oxidation or erosion of sensing modules Technical Overview The WD-AMX water leak detection modules are designed for use with the WD-CS, WD-PS and WD-RS water leak detection sensors. The modules have LED Indication of the water leak status and a sounder that can be enabled or disabled. The relay output can be used in manual or auto reset, and can be used as an alarm signal for connection to a BMS controller or remote alarm annunciation panel, such as the UI-AA1-F. The cable excitation used is an isolated AC signal which ensures the detector cable will not be subject to oxidation or erosion over time, avoiding the degradation problems associated with DC systems.

Page 2 of 5 Specification: Supply Voltage: WD-AMX-1 24Vac/dc ±10% WD-AMX-2 230Vac @ 50Hz Supply current 50mA max. Output 12A @ 250Vac LED Status indication for: Error condition Input sensitivity Relay output mode Learning Mode Response time <1 sec. after exposure Max. sensor cable length 200m (656ft) with leader cable Alarm hysteresis Dependent on sensitivity Audible alarm output 85dB@2.3Hz @ 10cm Electrical Terminals for 0.5-2.5² cable Connections Rising cage Ambient: Temperature 0 C to 40 C (32 to 104 F) RH 0-80% non-condensing Dimensions 72 x 64 x 55mm (2.83 x 2.52 x 2.17 ) Weights: WD-AMX-1 100g (0.22lb) WD-AMX-2 240g (0.53lb) Country of origin UK Part Codes: WD-AMX-1 24Vac/dc water detection alarm module with audible alarm and LED status indication WD-AMX-2 230Vac water detection alarm module with audible alarm and LED status indication Warning! When installed, the output relay contacts may carry 240Vac. Special care must be taken to isolate the switched voltages prior to any work being undertaken.

Page 3 of 5 Installation: Antistatic precautions must be observed when handling these sensors. The PCB contains circuitry that can be damaged by static discharge. 1. The WD-AMX should only be installed by a competent, suitably trained technician, experienced in installation with hazardous voltages. (>50Vac & <1000Vac or >75Vdc & 1500Vdc) 2. Ensure that all power is disconnected before carrying out any work on the WD-AMX. 3. Maximum cable is 2.5mm², care must be taken not to over tighten terminals. 4. When mounting the WD-AMX care should be taken not to stress the PCB when fitting to the DIN rail. If it is necessary to remove the module from the DIN rail, be sure to use a flat bladed screwdriver to release the DIN clips. 5. The WD-AMX-1 is designed to operate from a 24Vac or 24Vdc supply (so that power can be drawn from a 24Vac transformer used for other purposes if a 24Vdc supply is not available). The WD-AMX-2 is designed to operate from a 230Vac mains supply. 6. The relay output is an SPDT type, allowing either a Normally Open (NO) or Normally Closed (NC) connection. Operation: On power-up or by pressing the reset button, the unit enters learning mode, the mode jumper can be set to the required operating mode. In learning mode, the sensor sensitivity trimmer can be adjusted, and the level used as the threshold at which the unit will report an alarm. The unit will only be in learning mode for approximately 20 seconds after power-up or reset. After this time, the unit will enter run mode, so that any adjustment of the trimmer or change to the relay mode jumper has no effect. Note that if the reset button is pressed, the alarm will sound (if enabled) for at least two seconds as part of the initialisation function. In this event, the mode jumper and trimmer setting should be checked before the unit is left to monitor the sensor autonomously. When the unit is first powered up, the sounder will be activated (if enabled) and the LED s demonstrated. The relay will be left de-energised for a minimum of two seconds. This is so that there will be an alert reported over the relay if the reset button is pressed. Once the relay has been energised, it will be held in this state for a minimum of two seconds, even if a flood is detected immediately. Learning Mode: Changes in alarm threshold and relay output mode can only be made while the unit is in learning mode. Enter learning mode by pressing the reset switch.

Page 4 of 5 LED Status: Green LED: The green LED should be on continuously during normal operation, except in the off mode or there is an error (see Error Indication ). Yellow LED: This will be on if the sensor reading is more than 33% of the threshold setting. Orange LED: This will be on if the sensor reading is more than 66% of the threshold setting. Red LED: This will be on solidly if the sensor reading exceeds the threshold setting. If the red LED is flashing, it is either because the unit is in test mode or, if the green LED is off, because the unit has discovered an error (see Error Indication ). Error Indication: If the unit thinks that there is an error (for example, the sensor reads such an extreme level that a short circuit is suspected) then the red LED will flash continuously, the relay will be de-energised, and the sounder will be activated (if enabled). The sounder pattern will be three tones followed by a gap, to differentiate it from the flood warning. The green LED will be off to differentiate between an error report and the Test mode. The error report will be held until the reset button is pressed, although this function could reset automatically if the unit is in Reset mode. Relay Output Modes: Off: The relay will be de-energised and the sounder silent, no matter what the sensor condition. The green and yellow LEDs will flash alternately while in learning mode, and then just the green LED will flash continuously to show that this mode is selected. The other three LED s will indicate as normal. Reset: The WD-AMX will report all flood alerts by releasing the relay and activating the sounder (if enabled). Any transition will be reported for a minimum of two seconds. When the sensor stops indicating a flood, the unit resets automatically. Latch: In latching (manual reset) mode the WD-AMX reports the initial flood alert by releasing the relay and activating the sounder (if enabled). The relay and sounder will continue to indicate the alarm until the reset switch on the unit has been pressed. NB The LED s will indicate the true status of the sensor. On: This is a mode used to test the installation without needing to wet the sensor. The sounder and relay will be energised and the green and red LEDs will flash alternately for approximately 2 minutes to show that this mode is selected. After this time, the green LED will be ON while the red LED will continue to flash. Adjusting the Alarm Threshold: With the sensor connected and the unit power up, enter learning mode and then slowly adjust the threshold trimmer. As the input becomes more sensitive, the yellow, orange and finally red LED s will progressively light. If the red LED is lit, the sensitivity is set too high, and the unit is in alarm.

Page 5 of 5 Jumper Settings: Relay Mode Link: Sounder link: Off Silent Active Reset Latch On Connections: WD-AMX-1 Manual reset Relay output Sensitivity adjustment LED s WD-AMX-2 240Vac supply Relay output Sensitivity adjustment LED s Jumpers 24Vac/dc 0V Sensor input Sensor input Jumpers Manual reset Sensor input Whilst every effort has been made to ensure the accuracy of this specification, Sontay cannot accept responsibility for damage, injury, loss or expense from errors or omissions. In the interest of technical improvement, this specification may be altered without notice.