RD refrigerant distributors, for thermostatic expansion valves REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Similar documents
Liquid Distributor Type RD

Capacity regulators, type CPCE and LG REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Low Pressure Sight Glass Up to 35 bar MWP Type SG

Hot gas bypass regulator, type CPCE Liquid gas mixer, type LG (accessory)

Check valve Types NRV and NRVH

MAKING MODERN LIVING POSSIBLE. Thermostatic expansion valves, type TR 6 REFRIGERATION & AIR CONDITIONING DIVISION.

Thermostatic Expansion Valves Type TR 6

MAKING MODERN LIVING POSSIBLE. One valve for all purposes. TGE - thermostatic expansion valves REFRIGERATION & AIR CONDITIONING DIVISION

Thermostatic Expansion valves, type TUA/TUAE REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Tube-in-tube heat exchanger Type HE

Flexible. Upgrade and service with ease Extend lifetime with modular design. Thermostatic expansion valves Type TE5-55

General information on refrigerant controllers

CHECK VALVES INSTALLATION

FSW SECTION. Product guide. Expansion Valves, Solenoid Valves Water Valves & Oil Pressure Switches F SECTION. 71

Capacity regulator (hot gas bypass), type TUH/TCHE/TRHE REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Thermostatic expansion valves for ammonia Type TEA

REFRIGERATION PRODUCTS

HANDBOOK REGULATOR VALVES. Ed REGULATOR VALVES RP-ED 01/ ENG 1

Filter Driers with Replaceable Core

Tube-in-tube heat exchanger Type HE

FSW. Product guide. Driers and Sight Glasses CSECTION For more information visit

SOLENOID VALVES FOR REFRIGERATING SYSTEMS

Product Catalog VALVES

Revolutionary ETS Colibri valves Engineered to give you maximum flexibility and dependability

PULSE WIDTH MODULATING VALVES

OIL SEPARATORS APPLICATIONS

These valves can also be ordered as a bidirectional valve, allowing control of flow in both directions for use on heat pump applications.

Pressure switch KPU. Data sheet

Quick closing oil drain valve QDV

49 Danfoss Thermostat Kits Ranco Varifix Kits

Dehydrators and Filters

condenciat cl Condensing units Outdoor condensing unit Variable speed propeller fan Use Description for direct expansion applications

Thermostatic Expansion Valves

FSW SECTION. Product guide. Thermostats, Pressure Switches & Fan Speed Controls. E SECTION For more information visit

ELIMINATOR Hermetic filter drier for CO₂ DMSC for Sub-critical and DMT for Trans-critical application

THERMAL SOLUTIONS COAXIAL HEAT EXCHANGERS WKE, WKC

General Characteristics SM185S3QC. Dimensions. Terminal box. Electrical Characteristics. Recommended Installation torques

Typical Piping Diagram

Bulletin , March Electric Hot Gas Bypass Valves

Gas Detection Sensor type GDA, GDC, GDHC, GDHF, GDH REFRIGERATION AND AIR CONDITIONING. Technical leaflet

The Changing State of Refrigerants. Gary Parker Refrigerants Product Manager

10/4/2013. The Changing State of Refrigerants

Danfoss Scroll for Refrigeration MLM / MLZ

ENERSAVE Hydrocarbon Scroll Water Cooled Chiller

DEHYDRATORS AND FILTERS

Refrigerants and lubricants

Product Data. Features/Benefits. 28CB, 28LA Direct-Expansion. evaporator coils. 7 1 / 2 and 10 Nominal Tons Cooling

CDS 80. Continuous ventilation without dehumidification can be selected on the CDS 80 control panel.

WIBR SERIES. Unit Coolers - Technical Catalog Hunt St - Pryor, OK Fax

Accumulators - Suction Line

BALANCED PORT Q-VALVE

Product Data. Features/Benefits. 28CB, 28LA Direct-Expansion. evaporator coils. 7 1 / 2 and 10 Nominal Tons Cooling

MAKING MODERN LIVING POSSIBLE. MLZ / MLM Refrigeration scroll compressors Hz - R404A - R507 - R134a - R22. Selection & application guidelines

Introduction of Hanbell and

RCY. Filter drier receiver units 4.1. Refrigeration & Climate Components Solutions. n Applications

Product Data. Features/Benefits. 38AH Commercial Air-Cooled Condensing Units 50/60 Hz. 20 to 130 Nominal Tons (63 to 390 Nominal kw)

November 2006 / BULLETIN ELECTRIC DISCHARGE BYPASS VALVES

Gary Parker Refrigerants Product Manager

Gary Parker Refrigerants Product Manager

FACT SHEET 9 Large Air-Conditioning (air-to-air)

Küba SG commercial

Reducing Refrigerant Leakage

INSTALLATION INSTRUCTIONS

Brazed Plate Heat Exchanger for CO Applications

MAKING MODERN LIVING POSSIBLE. Check valve for EVRA, EVRAT and PM valves in liquid lines type NRVS. Technical brochure

A Series T 3. Unit Coolers - Technical Catalog. Product Benefits: Comdustrial TM Refrigeration. Adaptability- Durability- Serviceability-

Refrigerant Cycle. Performance Data 1) Electric. Acoustic Pressure Level. Compressor. Connections, Dimensions

SUSTAINABILITY WITH HIGH DANISH QUALITY

PRODUCT. TWB Two-Way Air Defrost Unit Coolers PRODUCT DATA & INSTALLATION. High Temperature (35 o F / 1.7 o C or Higher) Applications

Technical Data. Danfoss DHP-C. Provides heating, cooling and hot water TWS technology provides hot water quickly with low operating

FACT SHEET 9 Large Air-Conditioning (air-to-air)

Copeland Scroll Condensing Units for the Food Service Market

Refrigerators 650 & 1400 lt Smart

Zero ODP and negligible GWP when using hydrocarbons. Zero. portfolio for hydrocarbons.

Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s)

OPERATING INSTRUCTIONS

food-retail.danfoss.com Overview Brochure ADAP-KOOL Evaporator Controllers Achieve best-in-class energy efficiency and food safety

Above & Beyond. Refrigerated Compressed Air Dryers

Suction Accumulators. Introduction. Suction Accumulators

Temperature control of individual floor-heated rooms or mixed floor-heating/radiator systems

INSTALLATION INSTRUCTIONS FAS/FHS Series, Package Air Handling Units 6 to 25 Ton Air Conditioners 6to20TonHeatPump

Installation, Start-Up and Service Instructions

DTI Kenneth Bank Madsen Global Application Expert Food Retail

KTL Two-Way Low Profile Evaporators

MAKING MODERN LIVING POSSIBLE. Performer VSD. For Residential Applications - R410A. Quick reference

COOLING / HEATING COILS

Gas detecting sensor Types GDA, GDC, GDHC, GDHF, GDH

June 2001 / BULLETIN Way Valves. The right solenoid valve for any job.

Product Data. 40RUA/40RUS 6to15TonDirectExpansion 7.5to15TonChilledWater Packaged Air---Handling Units FEATURES/BENEFITS. Indoor air quality features

F Series - Refrigeration dryers

Quick closing oil drain valve, type QDV 15 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Optimize your HVAC/R application with the right Danfoss components

A: RS-45 is a non ozone depleting Drop-in replacement for R22 in most applications. A: RS-45 is a blend of R143a, R125, R134a and isobutane.

Technical data. Danfoss DHP-L

Head Pressure Control Valves

Natural Refrigerants: Future-proof Solutions for Today. eurammon End-Users Day 2011

CONDENSING UNITS AIR COOLED CONDENSER. COOLING ONLY

DOLPHIN FRESH WATER SHELL AND TUBE EVAPORATOR

Danfoss scroll compressors SM - SY - SZ

Ammonia. Background on ammonia as a refrigerant

Transcription:

RD refrigerant distributors, for thermostatic expansion valves REFRIGERATION AND AIR CONDITIONING Technical leaflet

Introduction RD refrigerant distributors distribute liquid refrigerants from the thermostatic expansion valve to individual sections of the evaporator. Note! The thermostatic expansion valve must have external pressure equalization. Application example Facts and features A wide range of RD refrigerant distributors is available, covering the majority of customer demands. RD design ensures a uniform distribution of refrigerant to each evaporator section. Suitable for CFC, HCFC and HFC refrigerants, including R410A. Max. working pressure: 48 bar (700 psig) 2 RD1CB102 Danfoss A/S (RC-CMS / MWA), 08-2004

Design 1. Cone 2. Nozzle 3. Locking ring 4. Nozzle diameter RD, flare RD, solder ODM Capacity Table 1 Capacity in kw for 1 m distributor tube with p = 0.5 bar Evaporating temperature t e [ C] R22 R407C Outer diameter of distributor tubes 3 / 16 in. / 5 mm 1 / 4 in. / 6 mm 5 / 16 in. / 8 mm 3 / 8 in. / 10 mm R134a R404A R507 R410A R22 R407C R134a R404A R507 R410A R22 R407C R134a R404A R507 R410A R22 R407C R134a R404A R507 R410A +10 +5 0 5 10 1.4 1.8 2.6 1.8 5.1 4.5 4 3.4 2.9 4.2 3.7 3.3 2.8 3.8 3.4 3 2.6 5.6 5.0 4.4 3.7 3.2 9.7 8.5 7.4 6.4 5.5 8 7 6.1 5.3 4.5 7.2 6.4 5.6 4.6 4.2 10.7 9.4 8.1 7.0 6.1 15.8 14 12.3 10.6 9.1 13.1 1 10.1 8.7 7.4 12 10.6 9.3 8 6.9 17.4 15.4 13.5 1 10 15 20 25 30 35 0.99 0.87 0.7 0.58 0.99 0.87 0.7 0.58 0.93 0.76 0.64 0.96 0.77 0.64 2 0.99 0.93 2.6 2.3 4.7 4 3.3 2.8 2.3 3.8 3.3 2.7 2.3 3.5 3 2.5 5.2 4.4 3.6 3.1 2.5 7.7 6.5 5.6 4.7 3.9 6.3 5.4 4.5 3.8 3.1 5.8 5 4.2 3.5 2.9 8.5 7.2 6.2 5.2 4.3 40 45 50 55 60 0.41 0.35 0.29 0.41 0.35 0.29 0.23 0.2 0.41 0.35 0.29 0.23 0.18 0.57 0.45 0.39 0.32 0.87 0.76 0.64 0.87 0.76 0.64 0.81 0.7 0.6 0.96 0.84 0.70 0.57 2 1.4 1 0.81 0.93 0.76 1.4 3.3 2.8 2.7 2.3 2 1.4 2.5 3.6 3.1 2.6 Table 2 Correction factor for tube length Tube length [mm] 250 400 550 700 850 1000 1150 1300 1450 1600 1750 Correction Factor 5 9 9 1 1.05 1.00 0.95 0.90 0.87 0.84 0.78 Table 3 Correction factor for liquid temperature Liquid temperature [ C] 10 15 20 25 28 30 35 40 45 50 Correction factor 9 1.40 4 1.09 1.00 0.95 0.82 0.71 0.61 Danfoss A/S (RC-CMS / MWA), 08-2004 RD1CB102 3

Capacity (Continued) It is recommended that distributor tubes be sized for a pressure drop of approx. 0.5 bar. Table 1, which gives the capacities for different tube sizes, is based on this pressure drop. For tube lengths exceeding 1 m, tubes should be selected with larger diameters than indicated in table 1. Figure 1 shows the relation between evaporator capacity Q e, refrigerant, tube diameter, evaporating temperature t e and pressure drop p for 1 m distributor tube. Figure 1 Ordering Table 4 RD, flare RD, solder Distributor Type Distributor inlet Rated capacity of expansion valves [R407C] Max. number of holes and size of distributor outlet (ODF) 3/16 in. / 5 mm 1/4 in. / 6 mm 5/16 in. / 8 mm RD21 4 3 1/2 in. flare RD27 6 5 25 kw (7 TR) RD21 4 3 1/2 in. / 12 mm solder ODM RD27 6 5 1/2 in. flare 9 6 9 6 1/2 in. / 12 mm solder ODM RD42 13 9 35 kw (10 TR) 5/8 in. flare 8 6 4 8 6 4 RD42 5/8 in. / 16 mm solder ODM 13 9 7 RD49 17 14 10 85kW (25 TR) RD49 17 14 10 7/8 in. / 22 mm solder ODM RD62 120kW (35 TR) 18 14 RD79* 250kW (70 TR) 24 19 15 11/8 in. / 28 mm solder ODM RD85* 27 22 18 300kW (85 TR) RD85* 13/8 in. / 35 mm solder ODM 27 22 18 * Replaceable nozzle, for nozzle with other diameters, see table 5 3/8 in. / 10 mm Table 5 Standard nozzle size Distributor type RD21 RD27 RD42 RD49 RD62 RD79 RD85 Nozzle diameter* 5.0 mm 6.0 mm 8.0 mm 9.0 mm 8.0 mm 10.1 mm 1 mm 14.3 mm 17.5 mm 18.5 mm Table 6 Rated capacity correction factor depending on refrigerant (for use in conjunction with table 4) Refrigerant R407C R22 R134a R507 R404A R410A Correction factor 1.00 0.92 0.72 0.68 0.68 4 * The optimum nozzle diameter depends on the plant conditions. 4 RD1CB102 Danfoss A/S (RC-CMS / MWA), 08-2004

Type nomenclature Example of a type code: RD 21 - H 05 - J 03 Refrigerant distributor Body Inlet connector Nozzle size Outlet connector Number of holes Table 7 Type RD Refrigerant Distributor Body 21 27 33 42 49 79 85 Ø21 mm Ø27 mm Ø33 mm Ø42 mm Ø49 mm Ø79 mm Ø85 mm Inlet connector A B C D E 12 mm solder ODM 16 mm solder ODM 22 mm solder ODM 28 mm solder ODM 35 mm solder ODM H J K L M 1/2 in. solder ODM 5/8 in. solder ODM 7/8 in. solder ODM 11/8 in. solder ODM 13/8 in. solder ODM P Q 1/2 in. flare F 5/8 in. flare F Nozzle size ## mm Outlet connector A 5 mm solder ODF B 6 mm solder ODF C 8 mm solder ODF D 10 mm solder ODF H J K L Number of holes ## 2 27 3/16 in. solder ODF 1/4 in. solder ODF 5/16 in. solder ODF 3/8 in. solder ODF Selection of refrigerant distributor The following data must be known: 1. Refrigerant 2. Evaporator capacity 3. Evaporating temperature 4. Liquid temperature 5. Number of evaporator sections 6. Evaporator section inlet size 7. Distributor tube length 8. Expansion valve type It is then possible to determine: I. Size of distributor tubes The capacity of the individual distributor tube is calculated by dividing the total evaporator capacity by the number of uniform evaporator sections. The tube diameter can then be determined from table 1 or figure 1. Sizing should be based on the average capacity of the evaporator. A sufficiently uniform distribution can be expected at capacities of between 40% and 125% of the values given in table 1. Example Given data: 1. Refrigerant = R404A 2. Evaporator capacity Q e = 20 kw 3. Evaporating temperature t e = 15 C 4. Liquid temperature T l = 20 C 5. Number of evaporator sections = 10 6. Evaporator section inlet size = 6 mm 7. Distributor tube length = 850 mm 8. Expansion valve with 22 mm ODF solder connection on outlet side The capacity of each individual distributor tube is 20 / 10 = 2.0 kw. Table 1 shows that with an evaporating temperature of 15 C and R404A, a Ø6 mm tube with a length of 1 meter will yield kw. Correction factors for tube length and liquid temperature are found in tables 2 and 3. For a tube length of 850 mm, the correction factor is 1.05. For a liquid temperature of 20 C, the correction factor is 4. Under the given conditions, the distributor tubes yield 4 1.05 = 7 kw The actual load, as a percentage of the listed rating, is thus 2.0 / 7 = 0.81 or 81%. The type of distributor, inlet size and type are determined from table 4. There are two possibilitis: RD49 or RD62 The rated capacity of the expansion valve can be found using table 6 together with table 4: RD49: 85 0.68 = 58 kw RD62: 120 0.68 = 82 kw Both distributors can be used, but RD 49 is selected because the rated capacity is closer to the evaporator capacity. The standard nozzle diameter is determined from table 5: 8 mm The required distributor type is determined from table 7: RD49-C08-B10 Please contact Danfoss for the code number. Danfoss A/S (RC-CMS / MWA), 08-2004 RD1CB102 5

Dimensions and weights RD, flare RD, solder ODM Table 8 Distributor type Distributor inlet L [mm] RD21 RD27 L 1 [mm] D [mm] Weight approx. [kg] Flare 55 21 0.1 Solder 31 10 21 0.1 Flare 65 10 27 0.1 Solder 41 10 27 0.1 Flare (1 2 in.) 71 33 0.2 Solder (1 2 in./12 mm) 50 12 33 0.2 Flare (5 8 in.) 76 33 0.2 Solder (5 8 in./16 mm) 50 17 33 0.2 RD42 Solder 52 12 42 0.2 RD49 Solder (5 8 in./16 mm) 62 17 49 0.3 Solder (7 8 in./22 mm) 62 24 49 0.3 RD62 Solder 66 24 62 0.7 9 RD79 Solder 81 25 79 0.9 RD85 Solder 81 30 85 0.9 Industrial pack 24 15 6 6 RD1CB102 Danfoss A/S (RC-CMS / MWA), 08-2004

Danfoss A/S (RC-CMS / MWA), 08-2004 RD1CB102 7

8 RD1CB102 Danfoss A/S (RC-CMS / MWA), 08-2004