WF Model Classic Washfountains Pre-Assembled Semi-Circular and Circular with 9" Deep Bowl

Similar documents
WF2803, WF2804, WF2805, WF2808 Bradstone Classic Washfountains

WF2803, WF2804, WF2805, WF2808 Bradstone Classic Washfountains

WF2803, WF2804, WF2805, WF2808 Bradstone Classic Washfountains

WF2503, WF2504, WF2505, WF2508 Terreon Classic Washfountains

WF2603, WF2604, WF2605, WF2608 Terrazzo Classic Washfountains

WF2613 Classic Corner Washfountain with 9" Deep Bowl

WF2613 Classic Corner Washfountain with 9" Deep Bowl

SN2003, SN2023, SN2004, SN2024 Sentry Semi-Circular Shallow Bowl Washfountain

WF3204. Extra Height 54" Terreon Semi-Circular Washfountain. Specifications

SN2003, SN2023, SN2004, SN2024

SN2005, SN2008 Sentry Circular Shallow Bowl Washfountain

SN2003, SN2023, SN2004, SN2024 Sentry Semi-Circular Shallow Bowl Washfountain

SN2013, SN2033 Sentry Corner Shallow Bowl Washfountains

TDB3104. Terreon 54" Semi-Circular, Deep Bowl Washfountain

TDB3105 Terreon 36" Circular, 7-1/2" Deep Bowl Washfountain

Express Lavatory System SS-Series

SS-1N Express Lavatory System SS-Series

SS-3N Express Lavatory System SS-Series

SS-2N Express Lavatory System SS-Series

BRADLEY CORPORATION WASH FOUNTAINS Page 1 of 8

Express Lavatory System MG-Series

Express Lavatory System MG-Series

AV60 Advocate Lavatory System AV-Series

AV30 Advocate Lavatory System AV-Series

FL-2H, FL-2L Frequency Lavatory System FL-Series

Terreon WARNING. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi.

WARNING. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi.

Installation Instructions

DISCONTINUED. LA75 Advocate Lavatory System LA-Series. Specifications. Code Compliance and Certifications. Construction

Installation Instructions

AV60 Advocate Lavatory System AV-Series

Installation. SS-2N TouchTime (Standard and Wall-Hung) Table of Contents. Express Lavatory System SS-Series

AV60 Advocate Lavatory System AV-Series

Installation Instructions

Installation CRS-2/IR, CRS-3/IR WARNING IMPORTANT. Table of Contents. Express Crescent Lavatory System CRS-Series

Installation. SS-3N Infrared (Standard and Wall-Hung) Table of Contents. Express Lavatory System SS-Series

AV90 Advocate Lavatory System AV-Series

Installation MG-2/IR. Express Lavatory System - MG Series with Adaptive Infrared Control. Table of Contents

LVQD3 Verge with WashBar Technology LVQ-Series

LC500. Patient Care Unit, 29", Fixed Water Closet. Specifi cations Standard Equipment

Installation TDB3104 WF3204. Table of Contents. Terreon 54" Semi-Circular Deep Bowl Washfountain with TouchTime

Installation Instructions

Installation Instructions

For Service Only. Installation Instructions EXD-2/STD EXD-2/JUV. Express Deck Lavatory System EXD Series

Installation SS-3N/IR/STD SS-3N/IR-WH. Express Lavatory System SS-Series. Table of Contents

WARNING. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi.

Terreon WARNING. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi.

LVSD2 Verge Wash Basin LVS-Series

Installation TDB3105 IMPORTANT! Table of Contents. Terreon 36" Circular Deep Bowl Washfountain with Infrared Control

DISCONTINUED. Installation. SS-2N/ndt/STD SS-2N/ndt/WH. Express Lavatory System SS-Series. Table of Contents

LVQD3 Verge with WashBar Technology LVQ-Series

Installation TDB3103 WF3203. Table of Contents. Terreon 36" Semi-circular Deep Bowl Washfountain with TouchTime Control

Installation LVRD1 IMPORTANT! Verge Lavatory System LVRD-Series with Evero Natural Quartz Material. Table of Contents

LVQD1 Verge with WashBar Technology LVQ-Series

Installation Instructions OBSOLETE

LVSD2 Verge Wash Basin LVS-Series

FL-3H, FL-3L Frequency Lavatory System FL-Series

Installation Instructions

LVRD3. Verge Lavatory System LVRD-Series with Evero Natural Quartz Material WARNING

WAW-2311 WAW-2322 WAW SERIES LAVATORIES

For Service Only. Installation Instructions SS-3/IR/WH97. Express Lavatory System SS-Series

Washfountain Application Guide

Installation Instructions

For Service Only. Installation Instructions EXD-3/WH97. Express Deck Lavatory System EXD Series

For Service Only. Installation Instructions. SS-3/AZ/WH97 Express Lavatory System SS-Series

LD-5010 OmniDeck with WashBar 5000 Series

FL-1H, FL-1L Frequency Lavatory System FL-Series

Installation LVSD2. Table of Contents. Verge Lavatory System LVS-Series with Evero Natural Quartz Material

LA45 DISCONTINUED IMPORTANT!

DISCONTINUED. Installation LD OmniDeck Series. Table of Contents

BRADLEY HALO EMERGENCY PLUMBING FIXTURES

BRADLEY HALO EMERGENCY PLUMBING FIXTURES (Short Form Version)

LIVIN THE DOG LIFE DRINKING FOUNTAINS INSTALLATION & OPERATION MANUAL

LA90 DISCONTINUED IMPORTANT!

LA60 DISCONTINUED IMPORTANT!

Installation. MG-2 TouchTime. Express Lavatory System - MG Series with TouchTime Metering. Table of Contents

A. All fixtures shall meet the requirements of ANSI A117.1, ANSI Z124.2 and the State of Texas Accessibility Standards (TAS).

PAT BASIN MODEL 9121, 9131, & 9141

1a Installing Optional Soap Dispenser for A/O Drain Units. A Place the upper tie bar on top of the. B Insert the tie rod assembly through the

School Solutions Ideabook

J120 STEAM BOOSTER INSTALLATION, OPERATION, AND SERVICE MANUAL J120 STEAM BOOSTER. J120 Steam Booster Manual D

A. Section Joint Sealants: Seal fixtures to walls and floors.

Installation LC840. Patient Care Unit, 40", Fixed Water Closet. Table of Contents

Willoughby Industries - Security Products

Terreon Lav Decks WARNING

DUKE UNIVERSITY CONSTRUCTION STANDARDS

C O D E S & A M M E N D M E N T S

Installation LVAD2. Table of Contents. Verge Wash Basin LVA-Series with Evero Natural Quartz Material

TABLE OF CONTENTS. BARIATRIC SINKS & TOILETS Specially engineered fixtures designed to withstand loads typical in bariatric care environments.

Packaged Steam Fired Water Heater

Installation LC800. Patient Care Unit, 47", Fixed Water Closet. Table of Contents

ESS-2200 Double Station Scrub Sink. with Two Sensor Operated Gooseneck Spout. ESS-3200 Deluxe Double Station Scrub Sink

Installation LVQD2. Table of Contents. Verge Lavatory System LVQ-Series with WashBar Technology

Durability within reach

Installation & Operation Manual

REFRIGERANT PIPING SYSTEM

Installation & Operation Manual

Willoughby Industries - Security Products

"SXDDR" Series Steam Heat Exchanger Humidifiers

PLUMBING FIXTURES Reserved

Transcription:

WF Model lassic Washfountains UP Approved Pre-Assembled owl and Pedestal Available in 5 or 36" iameter owl Size esigned for eavy uty and Washing Foot ontrol or Infrared Sensor Operation Available in or radstone New radstone olors now Available Specifi cations Size and apacity Semi-circular models accommodate up to 3 users (36" models) or 4 users (5 models) at a time. ircular models accommodate up to 5 users (36" models) or 8 users (5 models) at a time. All models utilize less water, energy and space than lavatories equipped with conventional faucets. The washfountain bowls, pedestals and valve sets are completely assembled. Only the support column and connections to the valve set and drain require assembly. The operating range is 20-80 PSI. Approximate flow-rates for each model: 36" semi-circular: 1.25 gpm 5 semi-circular: 3 gpm 36" circular: 2 gpm 5 circular: 5 gpm onstruction owl and Pedestal Materials onstructed of, a densified solid surface material composed of polyester resin. is resistant to chemicals, stains, burns and impact. Surface damage can be easily repaired with everyday cleansers or fine grit abrasives. radstone : An extremely durable plastic material made of reinforced thermosetting polyester resins, finely ground inorganic fillers and fade resistant pigments. Pedestals: onstructed of die-formed legs, upper braces, scuff bases and panels: legs are zinc chromate plated 14 gauge steel; upper braces are 16 gauge galvanized steel; and scuff bases are 300 series stainless steel with a #4 finish. models have pedestal panels with the same 300 series stainless steel and radstone models have tapered, vacuum-formed plastic panels. Standard Equipment Valves and Fittings In addition to the bowl and pedestal assembly, the following valves and fittings are standard: sprayhead with stainless steel support tube and bowl gasket; spud with domed strainer; sprayhead supply line; manual mixing valve; volume control valve; and (2) stop, strainer and check valves. ode ompliance and ertifi cations UP Approved The pre-assembled lassic Washfountains are Uniform Plumbing ode (UP) approved through the International Association of Plumbing and Mechanical Officials (IAPMO). ANSI Standards is NA certified to meet ANSI Z124.3, Z124.6 and ANSI/IPA SS-1-2001. U P WF2504 Activation ontrols Mechanical Foot ontrol (F) Each press of the foot rail mechanically actuates a hold-open valve, with slow closing upon release of foot pressure. Air Valve and ontrol (AST) Each push button pneumatically actuates a non-hold-open, air metering, singletemperature valve with field adjustable timing from 0 45 seconds. Factory preset at 10 seconds. Each push button activates a flow of tempered water from the non-sectional sprayhead. Push button requires less than five pounds of pressure. Electronic Infrared ontrol (IR) Each of the stream formers is controlled by a separate solenoid valve. ands placed within the bowl are detected by an infrared sensor module which activates a flow of tempered water from one station. Shut-off is automatic after hands are removed from the detection area. The infrared sensor uses a conical-shaped transmitting beam, having a detection area adapted to, but not exceeding, the bowl perimeter. The detection area projects forward 15 to each side and 15 below. The adaptive infrared sensor automatically adapts to the bowl after power is turned on. The infrared sensor is not affected by varying color tones or darkness. irect sunlight or bright washroom lights will not activate the system. Infrared models also include solenoid valves and a low-voltage transformer as standard equipment: Solenoid 24V, 50/60 z, 3/8" NPT. Few moving parts, and resistant to most chemicals, minerals, and impurities often present in municipal water supplies. Low-Voltage Transformer lass II UL/SA listed, 110/24 VA plug-in transformer. Plugs into a standard GFI protected electrical outlet. Location of transformer per local electrical code. Touch Time and ontrol (TT) Each low-voltage button actuates a non-hold-open, slow-closing anti-hammer solenoid valve that is timed from an electronic potted assembly. Each push button activates a flow of tempered water from the non-sectional sprayhead. Touch Time controls water flow at each station through the use of solid state, digital circuitry. Timing is electronically controlled at 15 seconds. Push button requires less than five pounds of pressure. R Page 1 of 9

WF Model lassic Washfountains Semi-ircular WF2503 and WF2504, ircular WF2505 and WF2508 WF2508 WF2504 WF2503 WF2505 Models (Must select one) Model Size Users Material WF2503 WF2504 WF2505 WF2508 36" Semi-ircular 5 Semi-ircular 36" ircular 5 ircular 3 4 5 8 Standard Selections (Must select one from each category) rain Type (select one) A Off-line vent with supplies from below entrally rising vent with supplies from above entrally rising vent with supplies from below O Off-line vent with supplies from above Pedestal eight (select one) ST Standard eight JUV Juvenile eight ontrols (select one) F Foot ontrol Valve IR Infrared Activation Mixing Valve (select one) MMV Manual Mixing Valve Soap ispenser (select one) PS Powdered Soap ispenser LS Liquid Soap ispenser TT AST NS TouchTime Metering Air Valve Metering No Soap ispenser owl olor (select one) SS-GRAY Soapstone Gray A-TAN anyon Tan Optional Selections Thermostatic Mixing Valve TMA Thermostatic Mixing Valve (in lieu of manual mixing valve) Metal Soap ispenser MLS Metal-lad Liquid Soap isp. MPS Metal-lad Powdered Soap isp. 1-1/2" Tie Pipe Assembly TA Shroud S ose ibb Reinforces Support Tube Stainless Steel Shroud (onceals Overhead Piping) ose ibb* Paper Towel ispensers T (2) -Fold, Multi-Fold ispenser *Non-cancelable, not-returnable ST (2) Single-Fold ispenser Page 2 of 9

WF Model lassic Washfountains Semi-ircular radstone WF2803 and WF2804, ircular radstone WF2805 and WF2808 WF2803 WF2804 WF2805 WF2808 Models (Must select one) Model Size Users Material WF2803 WF2804 WF2805 WF2808 36" Semi-ircular 5 Semi-ircular 36" ircular 5 ircular 3 4 5 8 radstone radstone radstone radstone Standard Selections (Must select one from each category) rain Type (select one) A Off-line vent with supplies from below entrally rising vent with supplies from above entrally rising vent with supplies from below O Off-line vent with supplies from above Pedestal eight (select one) ST Standard eight ontrols (select one) F Foot ontrol Valve IR Infrared Activation Mixing Valve (select one) MMV Manual Mixing Valve Soap ispenser (select one) PS Powdered Soap ispenser LS Liquid Soap ispenser radstone owl olor (select one) SOX Sandbox ON arbon Optional Selections Thermostatic Mixing Valve TMA TT AST NS Thermostatic Mixing Valve (in lieu of manual mixing valve) Metal Soap ispenser MLS Metal-lad Liquid Soap ispenser MPS Metal-lad Powdered Soap ispenser 1-1/2" Tie Pipe Assembly TA Shroud S Reinforces Support Tube Stainless Steel Shroud (onceals Overhead Piping) Paper Towel ispensers T (2) -Fold, Multi-Fold ispenser *Non-cancelable, not-returnable TouchTime Metering Air Valve Metering No Soap ispenser SFT (2) Single-Fold ispenser Page 3 of 9

WF Model lassic Washfountains imensions Semi-ircular Add 3-1/2" to imensions & E for Optional TouchTime (TT), Infrared Sensor (IR) or Air Wave (AST) radstone J J I I E E F F A G imensions Inches (mm) Material Size A* * * * ** E* ** F* G I J 54 (1372) 19 (483) 29-1/2 (749) 38-3/4 (984) 47-1/4 (1200) 55-3/4 (1416) 36-1/2 (927) 23-1/2 (597) 21-1/4 (540) 32-1/4 (819) 5-1/4 (133) radstone 54 (1372) N/A 29 (737) 37-3/4 (959) 46-1/4 (1175) 55-3/4 (1391) 35 (889) N/A 24-1/4 (616) 35-1/4 (895) 8-1/4 (222) 36 (914) 19 (483) 29-1/2 (749) 35-1/4 (895) 43-1/4 (1099) 52-1/4 (1327) 33-3/8 (848) 17-1/4 (438) 15-1/4 (387) 22-3/4 (578) 4-3/4 (121) radstone 36 (914) N/A 29 (737) 34-1/4 (870) 42-1/2 (1080) 51 (1295) 35 (889) N/A 18-1/4 (464) 25-3/4 (654) 7-3/4 (197) * Juvenile eight: Subtract from dimensions A through F for juvenile height. Juvenile eight is not available in radstone. ** Add 3-1/2" (mm) for optional TouchTime (TT), infrared sensor (IR) or air valve (AST). Page 4 of 9

WF Model lassic Washfountains imensions ircular radstone Add 3-1/2" to imensions & E for Optional TouchTime (TT), Infrared Sensor (IR) or Air Wave (AST) E E A F F G imensions Inches (mm) Material Size A* * * * ** E* ** F* G 54 (1372) 19 (483) 29-1/2 (749) 38-3/4 (984) 47-1/4 (1200) 55-3/4 (1416) 32 (813) 36 (914) 54 (1372) radstone 54 (1372) N/A 29 (737) 37-3/4 (959) 46-1/4 (1175) 55-3/4 (1391) 32 (813) N/A 54 (1372) 36 (914) 19 (483) 29-1/2 (749) 35-1/4 (895) 43-1/4 (1099) 52-1/4 (1327) 21 (533) 25 (635) 36 (914) radstone 36 (914) N/A 29 (737) 34-1/4 (870) 42-1/2 (1080) 51 (1295) 21 (533) N/A 36 (914) * Juvenile eight: Subtract from dimensions A through F for juvenile height. Juvenile eight is not available in radstone. ** Add 3-1/2" (mm) for optional TouchTime (TT), infrared sensor (IR) or air valve (AST). Page 5 of 9

Rough-Ins Semi-ircular Type A Off-line vent with supplies from below. Top View WF Model lassic Washfountains Rough-In Notes 1. All pipes and fittings not furnished by radley are shown in broken lines. 2. Supply lines for one to two washfountains should be 1"; for three washfountains 1-1/; for more than three washfountains, pipe sizes should be increased proportionately. 3. Overhead supplies must be reduced to 1/2" copper tube to pass through support tube. 4. heck valve inlets are 1/2" NPT. 5. rain Types and : For maximum rigidity of sprayhead/support tube assembly, use 1-1/2" NPT galvanized pipe for vent. Use of plastic or copper for vent is not recommended. 1" NPT Supplies Through Wall 2" NPT rain Through Wall (Stub Out to Suit Trap imension) Trap 2" NPT rain Through Floor (Stub Up 3" (76mm) Above Floor) 3-1/ (83mm) See elow 1" NPT Supplies Through Floor (Optional) Stub Up 2-1/2" (64mm) Above Floor enter Line of rain to enter Line of Fixture 5 (1372mm) Type O Off-line vent with supplies from above. Top View 1" NPT Supplies from Above Must Reduce to 1/2" Nom. opper Tube on These enters to Pass Thru Washfountain 2" NPT rain Through Wall (Stub Out to Suit Trap imension) See elow * Trap (22mm) (22mm) 1-1/ (32mm) 2" NPT rain Through Floor (Stub Up 3" (76mm) Above Floor) 5 (1372mm) enter Line of rain to enter Line of Fixture Side View rain Through Wall learance ole Wall Trap for Wall Outlet Only Side View learance ole rain Through Wall Trap for Wall Outlet Only ** 12" (305mm) for Standard eight 8-1/ (210mm) for Juvenile eight ** Wall Supplies Through Wall Floor rain and Supplies Through Floor Trap Located elow Floor (Optional) Floor rain and Supplies Through Floor Trap Located elow Floor (Optional) Installing Traps When installing trap with a coupling and nipple, see dimension in the chart below. If trap is installed tight to bottom of bowl, dimension depends on design of trap. Material owl Size * ** (Standard eight) ** (Juvenile eight) owl Size * ** (Standard eight) ** (Juvenile eight) 5 (1372mm) 5-1/ (133mm) 6 to 13-1/ (152 to 337mm) 6 to 10-1/ (152 to 260mm) 4-3/ (121mm) 6 to 13-1/ (152 to 337mm) 6 to 10-1/ (152 to 260mm) radstone 5 (1372mm) 8-1/ (210mm) 6 to 11-5/8" (152 to 295mm) 6 to 8-5/8" (152 to 219mm) 7-3/ (197mm) 6 to 12" (152 to 305mm) 6 to 9" (152 to 229mm) * Wall to centerline of trap ** enterline of drain to floor Page 6 of 9

Rough-Ins Semi-ircular (continued) WF Model lassic Washfountains Type entrally rising vent with supplies from above. Top View Side View 1" NPT Supplies from Above Must Reduce to 1/2" Nom. opper Tube on These enters to Pass Thru Washfountain (22mm) (22mm) 4-3/ (121mm) for owl 7-3/ (197mm) for radstone owl 5-1/ (133mm) for 5 (1372mm) owl 8-1/ (210mm) for 5 (1372mm) radstone owl Wall 1-1/ (32mm) 1-1/2" NPT Vent to eiling 2" NPT rain Through Floor (Stub Up 3" (76mm) Above Floor) Vent 5 (1372mm) Washfountain owl Type entrally rising vent with supplies from below. Top View 1" NPT Supplies Through Wall Side View 3-1/ (83mm) 4-3/ (121mm) for owl 7-3/ (197mm) for radstone owl 5-1/ (133mm) for 5 (1372mm) owl 8-1/ (210mm) for 5 (1372mm) radstone owl Vent 1-1/2" NPT Vent to eiling 5 (1372mm) 2" NPT rain Through Floor (Stub Up 3" (76mm) Above Floor) 12" (305mm) for Standard eight 8-1/ (210mm) for Juvenile eight 1" NPT Supplies Through Floor (Optional) Stub Up 2-1/2" (63mm) Above Floor Note: Vented Trap oes Not omply With UP WALL Floor Note: Vented Trap oes Not omply With UP rain Through Floor rain Through Floor Supplies Through Floor (Optional) imensions Pedestal Anchoring owl Size 5 (1372mm) 36" (914mm) Standard eight Juvenile eight G J G J 16-1/2" (419mm) 11" (279mm) 1 (356mm) 8-5/8" (219mm) 18-1/ (464mm) 18-1/ (464mm) 16-1/2" (419mm) 11" (279mm) 1 (356mm) 8-5/8" (219mm) 14-1/ (362mm) 14-1/ (362mm) J G G Anchoring Pedestals 1. Place pedestal assembly as shown. 2. Anchor pedestal assembly to floor and wall with suitable wall fasteners. acking may be required in some types of wall construction. Page 7 of 9

Rough-Ins Semi-ircular (continued) WF Model lassic Washfountains Types A and O Types and Fixture enterline Vented Trap 111-024 * 11"* (279mm) 7" (178mm) rain Through Floor (Optional) * Suggested location of 110VA GFI electrical outlet. Always check local codes before installing. Outlet may be required to be in a remote location. Material owl Size Standard eight Juvenile eight Standard eight Juvenile eight 5 (1372mm) 5-1/ (133mm) 18-5/8" (473mm) 14-5/8" (371mm) 6 to 13-1/ (152 to 337mm) 6 to 10-1/ (152 to 260mm) radstone 5 (1372mm) 8-1/ (210mm) 17" (432mm) 13" (330mm) 6 to 11-5/8" (152 to 295mm) 6 to 8-5/8" (152 to 219mm) 4-3/ (121mm) 18-5/8" (473mm) 14-5/8" (371mm) 6 to 13-1/ (152 to 337mm) 6 to 10-1/ (152 to 260mm) radstone 7-3/ (197mm) 17-3/8" (441mm) 13-3/8" (340mm) 6 to 12" (152 to 305mm) 6 to 9" (152 to 229mm) Page 8 of 9

Rough-Ins ircular Type A Off-line vent with supplies from below. WF Model lassic Washfountains Type entrally rising vent with supplies from above. 1" NPT Supplies Through Floor: Stub Up 2-1/2" (64mm) Above Floor Note: Vented Trap oes Not omply with UP 1" NPT Supplies Through Floor: Must Reduce to 1/2 Nom. opper Tube on These enters to Pass Through Washfountain (22.2mm) (22.2mm) 2-1/2" (64mm) 5"* (127mm) onduit Location (IR Only) 1-1/ (32mm) 5"* (127mm) onduit Location (IR Only) 2" NPT rain: Stub Up 3" (76mm) Above Floor 2" NPT rain: Stub Up 3" (76mm) Above Floor 1-1/2" NPT Vent to eiling 5 (1372mm) owl owl 5 (1372mm) owl owl Type entrally rising vent with supplies from below. Type O Off-line vent with supplies from above. Note: Vented Trap oes Not omply with UP 1" NPT Supplies Through Floor: Stub Up 2-1/2" (64mm) Above Floor 1" NPT Supplies Through Floor: Must Reduce to 1/2 Nom. opper Tube on These enters to Pass Through Washfountain 2" NPT rain: Stub Up 3" (76mm) Above Floor 2-1/2" (64mm) 1-1/ (32mm) (22.2mm) (22.2mm) 5"* (127mm) onduit Location (IR Only) 1-1/2" NPT Vent to eiling 5"* (127mm) onduit Location (IR Only) 2" NPT rain: Stub Up 3" (76mm) Above Floor 5 (1372mm) owl owl * Remote mounting of transformer with 24 VA electrical supply to washfountain is recommended. See local electrical codes before roughing in. (This conduit location is only a recommendation.) 5 (1372mm) owl owl Page 9 of 9