SS-1N Express Lavatory System SS-Series

Similar documents
Express Lavatory System SS-Series

SS-2N Express Lavatory System SS-Series

FL-2H, FL-2L Frequency Lavatory System FL-Series

SS-3N Express Lavatory System SS-Series

TDB3104. Terreon 54" Semi-Circular, Deep Bowl Washfountain

TDB3105 Terreon 36" Circular, 7-1/2" Deep Bowl Washfountain

Express Lavatory System MG-Series

Express Lavatory System MG-Series

AV30 Advocate Lavatory System AV-Series

DISCONTINUED. LA75 Advocate Lavatory System LA-Series. Specifications. Code Compliance and Certifications. Construction

AV60 Advocate Lavatory System AV-Series

SN2003, SN2023, SN2004, SN2024 Sentry Semi-Circular Shallow Bowl Washfountain

FL-1H, FL-1L Frequency Lavatory System FL-Series

SN2003, SN2023, SN2004, SN2024

AV60 Advocate Lavatory System AV-Series

AV60 Advocate Lavatory System AV-Series

AV90 Advocate Lavatory System AV-Series

WF3204. Extra Height 54" Terreon Semi-Circular Washfountain. Specifications

SN2003, SN2023, SN2004, SN2024 Sentry Semi-Circular Shallow Bowl Washfountain

LD-5010 OmniDeck with WashBar 5000 Series

SN2013, SN2033 Sentry Corner Shallow Bowl Washfountains

SN2005, SN2008 Sentry Circular Shallow Bowl Washfountain

WF2613 Classic Corner Washfountain with 9" Deep Bowl

WF Model Classic Washfountains Pre-Assembled Semi-Circular and Circular with 9" Deep Bowl

FL-3H, FL-3L Frequency Lavatory System FL-Series

WF2613 Classic Corner Washfountain with 9" Deep Bowl

WF2503, WF2504, WF2505, WF2508 Terreon Classic Washfountains

For Service Only. Installation Instructions SS-3/IR/WH97. Express Lavatory System SS-Series

LVSD2 Verge Wash Basin LVS-Series

WF2803, WF2804, WF2805, WF2808 Bradstone Classic Washfountains

WF2603, WF2604, WF2605, WF2608 Terrazzo Classic Washfountains

Installation Instructions OBSOLETE

WF2803, WF2804, WF2805, WF2808 Bradstone Classic Washfountains

For Service Only. Installation Instructions EXD-2/STD EXD-2/JUV. Express Deck Lavatory System EXD Series

For Service Only. Installation Instructions. SS-3/AZ/WH97 Express Lavatory System SS-Series

Installation CRS-2/IR, CRS-3/IR WARNING IMPORTANT. Table of Contents. Express Crescent Lavatory System CRS-Series

LVSD2 Verge Wash Basin LVS-Series

WF2803, WF2804, WF2805, WF2808 Bradstone Classic Washfountains

Installation. SS-2N TouchTime (Standard and Wall-Hung) Table of Contents. Express Lavatory System SS-Series

BRADLEY CORPORATION WASH FOUNTAINS Page 1 of 8

For Service Only. Installation Instructions EXD-3/WH97. Express Deck Lavatory System EXD Series

Installation. SS-3N Infrared (Standard and Wall-Hung) Table of Contents. Express Lavatory System SS-Series

Installation SS-3N/IR/STD SS-3N/IR-WH. Express Lavatory System SS-Series. Table of Contents

DISCONTINUED. Installation LD OmniDeck Series. Table of Contents

Installation LVRD1 IMPORTANT! Verge Lavatory System LVRD-Series with Evero Natural Quartz Material. Table of Contents

Installation MG-2/IR. Express Lavatory System - MG Series with Adaptive Infrared Control. Table of Contents

LVQD3 Verge with WashBar Technology LVQ-Series

DISCONTINUED. Installation. SS-2N/ndt/STD SS-2N/ndt/WH. Express Lavatory System SS-Series. Table of Contents

Terreon Lav Decks WARNING

PAT BASIN MODEL 9121, 9131, & 9141

LVQD3 Verge with WashBar Technology LVQ-Series

Installation LD3060. OmniDeck Series. Table of Contents Rev. R; ECM Bradley Corporation Page 1 of 10 3/30/11

LVRD3. Verge Lavatory System LVRD-Series with Evero Natural Quartz Material WARNING

Installation LVSD2. Table of Contents. Verge Lavatory System LVS-Series with Evero Natural Quartz Material

LVQD1 Verge with WashBar Technology LVQ-Series

Installation TDB3103 WF3203. Table of Contents. Terreon 36" Semi-circular Deep Bowl Washfountain with TouchTime Control

Washfountain Application Guide

Installation. MG-2 TouchTime. Express Lavatory System - MG Series with TouchTime Metering. Table of Contents

LA45 DISCONTINUED IMPORTANT!

Installation TDB3104 WF3204. Table of Contents. Terreon 54" Semi-Circular Deep Bowl Washfountain with TouchTime

Installation TDB3105 IMPORTANT! Table of Contents. Terreon 36" Circular Deep Bowl Washfountain with Infrared Control

LA60 DISCONTINUED IMPORTANT!

School Solutions Ideabook

LA90 DISCONTINUED IMPORTANT!

Model Z TAS. Standards Compliance. Sundara Drift Double Basin Hand Washing System

LC500. Patient Care Unit, 29", Fixed Water Closet. Specifi cations Standard Equipment

Installation LVAD2. Table of Contents. Verge Wash Basin LVA-Series with Evero Natural Quartz Material

Model Z Sundara Reef Triple Basin Hand Washing System

ESS-2200 Double Station Scrub Sink. with Two Sensor Operated Gooseneck Spout. ESS-3200 Deluxe Double Station Scrub Sink

A. All fixtures shall meet the requirements of ANSI A117.1, ANSI Z124.2 and the State of Texas Accessibility Standards (TAS).

SPEAKMAN SAFETY PRODUCTS Installation, Maintenance & Operation Instructions SEF-18XY, EYESAVER FAUCET with SENSORFLOW, Battery or AC POWER

? Teflon Tape? 9/16 Fixture Wall Anchors and. ? 9/32 Fixture Wall Anchors and

Model Z Sundara Float Double Basin Hand Washing System

MERIDIAN MODEL# 3793

DUKE UNIVERSITY CONSTRUCTION STANDARDS

A. Section Joint Sealants: Seal fixtures to walls and floors.

WARNING. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi.

Installation LC800. Patient Care Unit, 47", Fixed Water Closet. Table of Contents

Terreon WARNING. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi.

DESIGN STANDARDS SECTION PLUMBING FIXTURES AND EQUIPMENT. 1.3 Wall hung toilet room fixtures. Urinals for handicapped may be stall type.

DESIGN STANDARDS SECTION Toilet rooms and utility rooms to have floor drains at lowest point.

Installation LC840. Patient Care Unit, 40", Fixed Water Closet. Table of Contents

IMPORTANT. Wash Basin 1.0 Installation. Installation instructions for models:

INSTALLATION, OPERATIONS & MAINTENANCE MANUAL

WARNING. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi.

Ligature Resistant Sensor Faucet Patent # US D635,386 #SAL-5011/SF370

Terreon WARNING. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi.

WAW-2311 WAW-2322 WAW SERIES LAVATORIES

Installation LVQD2. Table of Contents. Verge Lavatory System LVQ-Series with WashBar Technology

Installation Instructions

BRADLEY HALO EMERGENCY PLUMBING FIXTURES (Short Form Version)

CONTINENTAL METAL PRODUCTS. Stainless Steel Healthcare Equipment Meeting the Demands of the OR. Proudly Made in the USA for over 65 years

BRADLEY CORPORATION DOMESTIC WATER PIPING SPECIALTIES Page 1 of 9

Durability within reach

WARNING NOTICE. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi. IMPORTANT

Installation LVQD1. Table of Contents. Verge Lavatory System LVQ-Series with WashBar Technology

LIVIN THE DOG LIFE DRINKING FOUNTAINS INSTALLATION & OPERATION MANUAL

Automatic Temperature Controller (ATC)

BRADLEY HALO EMERGENCY PLUMBING FIXTURES

2). Crane Co. 4). Kohler Co. 5). Universal-Rundle Corp. Revised September 29, 2017 Commercial Plumbing Fixtures

Transcription:

ADA, ANSI, TAS and UFAS Compliant Constructed of Vandal Resistant-Terreon Solid Surface Material Available in 29 Colors Choose from a Terreon Sprayhead or a Bowl Only Model with Your Choice of Faucet Optional Deck-Mounted Soap Dispensers Mount with Optional Surface Bracket by Bradley or In-Wall Carriers by Others Optional Tankless Electric Water Heater Specifi cations Wall-hung single station fixture. Designed specifically for high traffic commercial hand washing applications. The preassembled sprayhead module is equipped with an independent stream-former that is served by an infrared sensing module and solenoid valve (Model SS-1N/IR), an independent battery IR sensor and battery (Model SS-1N/BIR3) or a push-button TouchTime electronic metering valve (Model SS-1N/TT). Standard flow rate of.5 GPM meets industry standards for water conservation, while providing enough water to rinse hands quickly and efficiently. Operating range is 20 80 PSI. Construction Bowl and Sprayhead Constructed of Terreon, a densified solid surface material composed of polyester resin, or TerreonRE, a densifi ed solid surface material composed of a bio-based resin and preconsumer recycled granules. Terreon and TerreonRE are resistant to chemicals, stains, burns and impact. Surface damage can be easily repaired with everyday cleansers or fine grit abrasives. Terreon and TerreonRE are certified by NAHB to meet ANSI Z124.3, Z124.6 and ANSI/ICPA SS-1-2001. Terreon and TerreonRE are GREENGUARD certified as lowemitting materials. High Impact Polymer Trap Cover Optional trap cover is composed of vacuum-formed acrylic laminate. It is highly resistant to impact, abrasion, acid and corrosion. The panel will not chip, peel or flake. This option is not compatible with a tankless electric water heater or a sensor-operated soap dispenser. Stainless Steel Trap Cover The optional stainless steel trap cover is constructed of 22 gauge Type 304 stainless steel with a #4 fi nish and is mounted with (4) ¼"-20 fasteners (supplied by others) into (4) wall anchors (supplied by others). The stainless steel trap cover is compatible with a tankless electric water heater or a sensor-operated soap dispenser. Vandal Resistance The molded sprayhead is bolted securely to the lavatory bowl. The Terreon and TerreonRE bowls are resistant to chemicals, stains, burns and impact. Damage is repairable. The chrome plated brass streamformer and activation mechanism are secured to the unit from inside the sprayhead module. The infrared sensor will automatically shut off water flow after 30 45 seconds if a vandal attempts to trigger constant operation. TouchTime activation is electronically controlled at 15 seconds. Optional trap covers conceal all below deck valving, connections and other optional items. SS-1N Infrared Express Lavatory System shown with optional acrylic trap cover Code Compliance and Certifi cations ANSI Standards Terreon and TerreonRE are certified by NAHB to meet ANSI Z124.3, Z124.6 and ANSI/ICPA SS-1-2001. UPC Approval The Express Lav Systems are Uniform Plumbing Code (UPC) approved through the International Association of Plumbing and Mechanical Officials (IAPMO). This plumbing fixture is designed for hand washing only. It is not Intended to dispense water for human consumption through drinking or for preparation of food or beverages Mounting The Express SS-1N is designed to mount at different heights (adult and children) to comply with guidelines on reaches, clearances and operation for various codes including, ADA Accessibility Guidelines for Buildings and Facilities (ADAAG) and TAS (Texas Accessibility Standards). Always check your local and state codes.the SS-1N can be supported by a surface-mounted bracket supplied by Bradley or in-wall carriers supplied by others. The surface-mounted bracket is constructed of 1" square structural tubing and is zinc-plated mild steel. The surface-mounted bracket also includes a locking device and leveling screws. TAS Page 1 of 7

Standard Equipment Models SS-1N/IR and SS-1N/TT include bowl, a 110/24 VAC plug-in transformer, flexible stainless steel supply connection, P-trap, grid strainer and tailpiece. Battery included in SS-1N/BIR3 only. The SS-1N (bowl only) includes P-trap, grid strainer and tailpiece. Optional Equipment The SS-1N is available less solid surface sprayhead as a bowl-only unit drilled for a 4" and 8" centerset or centershank faucet options. Equip with your choice of Bradley faucets or a faucet by others. The various SS-1N models can be equipped with a deck-mounted soap dispenser. Optional trap covers and optional surface-mounted brackets are also available. Express Lavatory System Thermostatic Tankless Electric Water Heater The optional tankless electric water heater is equipped with a microprocessing temperature control capable of maintaining outlet temperature accuracy of +/- 1 F. Factory preset at 105º F. Flow switch activates heater only on demand with 99% efficiency. For easy service, the heater features a replacement cartridge element. Select TC-STEEL if a trap cover is desired with the heater option. Heaters not available with BIR3 activation. Model KW VAC Amps Temp. Rise @ 1 GPM EX95TMLB 9.5 240/208* 40 65 F EX100TMLB 10 277 36 68 F *240 volt can also be rated 208 volts with a 25% reduction in power TouchTime Metering Control The low voltage push button activates a non-hold-open, slow closing anti-hammer solenoid valve that is timed from an electronic potted assembly. The push button activates one valve, which, in turn, activates water flow. TouchTime controls water fl ow through the use of solid state, digital circuitry. Timing is electronically controlled at 15 seconds. Battery Infrared Sensor The battery-powered sensor uses a zone-focused infrared transmitting beam, creating a large detection area not exceeding the bowl perimeter. The sensor is not affected by varying skin tones or darkness. When hands enter the detection area, the sensor starts water flow by opening the valve electronically. When hands leave the detection area, the sensor stops the flow of water by closing the electronically activated solenoid valve. The 6-volt DC, electronically activated solenoid valve has few moving parts providing reliable operation which is unaffected by most chemicals and minerals often present in municipal water supplies. The station is powered by a single lithium battery. Battery type is Duracell DL 223A or equivalent (battery included). Flow Control Rate Operating range 20 80 psi. Flow restrictor keeps flow rate constant at all pressures. Flow rate: 0.5 GPM. For more information on faucets, valves, transformers, cabinets and soap dispensers, visit. U.S. Patent Pending Sensor-Operated Soap Dispenser The optional sensor-operated soap dispenser (6315) is available on all SS-1N units. The soap dispenser features reliable infrared metering activation and LED indicators for Low Battery / Low Soap Refi ll (soap not included). The dispenser is powered by (4) D -cell batteries (not included). 27-oz. (1000-shot) and 54-oz. (2000-shot) soap bottles are available from Bradley for use with the sensor operated soap dispenser. Sensor operated soap dispenser (6315) is compatible with the stainless steel trap cover only. Activation Controls Infrared Sensor The streamformer is controlled by a solenoid valve. Hands placed within the bowl are detected by an infrared sensor module, which activates a flow of tempered water to the streamformer. Shut-off is automatic after hands are removed from the detection area. The infrared sensor uses a conical shaped transmitting beam, having a detection area adapted to, but not exceeding, the bowl perimeter. The detection area projects forward 15 to each side and 15 below horizontal. The infrared sensor automatically adapts to the bowl after power is turned on. The infrared sensor is not affected by varying color tones or darkness. Direct sunlight or bright washroom lights will not activate the system. Includes solenoid valve and a low voltage transformer as standard equipment: Solenoid - 24V, 50/60 Hz, 3 8" NPT. Few moving parts, and resistant to most chemicals, minerals, and impurities often present in municipal water supplies. Low Voltage Transformer - Class II UL/CSA listed, 110/24 VAC plug-in transformer. Plugs into a standard GFCI protected electrical outlet. Page 2 of 7

Top View 7¼" (184mm) 8 1 8" (206mm) 21¼" (540mm) Front View 4" (102mm) Install #10 Anchors (4) Places 21½" (546mm) SS-1N IR with Optional Stainless Steel Trap Cover 13" (330mm) 8" (203mm) 20¼" (514mm) Ref. 21" (533mm) Ref. Front View 4" (102mm) 19 5 8" (498mm) 11 1 8" (283mm) SS-1N TT with Optional Acrylic Trap Cover 17 7 8" (454mm) Ref. Page 3 of 7

Stainless Steel Trap Cover Standard Height Juvenile Height: Ages 6 through 12 34" (864mm) 38½" (978mm) 31" (787mm) 27" (686mm) 35½" (902mm) 17" (432mm) 14" (356mm) Grades Pre-K through 5 or 6 Grades 6 through 8 or 9 34½" (876mm) 36½" (927mm) 26" (660mm) 32" (813mm) 28" (711mm) 13" (330mm) 15" (381mm) Page 4 of 7

High Impact Polymer Trap Cover Standard Height Juvenile Height: Ages 6 through 12 34" (864mm) 38½" (978mm) 31" (787mm) 27" (686mm) 35½" (902mm) 19" (483mm) 16" (406mm) Grades Pre-K through 5 or 6 Grades 6 through 8 or 9 34½" (876mm) 36½" (927mm) 26" (660mm) 15" (381mm) 32" (813mm) 28" (711mm) 17" (432mm) Page 5 of 7

SS-1N Rough-in Bowl Outline 38½" (978mm) D 3 3 8" (86mm) 2" (51mm) C D B 34" (864mm) Hot A A 2" (51mm) 26 7 8" (683mm) 27" (686mm) E 4" (102mm) Cold or Tempered Supply 23" (584mm) 26¼" (667mm) 5½" (140mm) 20½" (521mm) Fixture Centerline Floor Chart 1 Rim Height Vertical Height Adjustments A E Fixture Style 34" None Standard Height 34" None Wall-Hung 32" Subtract 2" TAS, Grades 6 through 8 or 9 31" Subtract 3" Juvenile Height Subtract 4" TAS, Pre-K through Grades 5 or 6 Chart 2 Code Description Qty. A ½" NPT Hot/Cold Supplies, Stub-Out 2" from Wall 2 B 1½" NPT Drain, Stub-Out 2" from Wall 1 C 110V GFCI Protected Electrical Outlet. I.R. and TouchTime Only 1 D #10 Fasteners/Wall Anchors, Optional 2 E Optional Heater, Electric Box Location. 4" L x 4" W x 4" H 1 Page 6 of 7

Standard Selections (Must select one from each category) Sprayhead or Faucet Drilling IR Sprayhead w/infrared Control BIR3 TT Sprayhead w/battery Infrared Control Sprayhead w/touchtime Control Soap Dispenser (select one) 6322 16-oz Plastic Globe, 2½" Spout 6322-67 6322-68 16-oz Stainless Steel Globe, 2½" Spout 32-oz Plastic Globe, 2½" Spout 4" SET 4" Centerset 8" SET 8" Centerset SHANK Centershank 6315 SDO NSD For 6315 Dispenser must order as separate line items P19-232B 1000-Shot or 27-oz Lotion Soap with Moisturizer (Case of 4 Bottles) P19-232A P19-231F AC Adapter 6315 2000-Shot or 54-oz Lotion Soap with Moisturizer (Case of 4 Bottles) Water Supply (select one) TMA Vernatherm Thermostatic Mixing Valve (Hot and Cold Supplies) TL Single Tempered Line Tankless Heaters (Not Available with BIR3 Activations) HEAT277 Tankless Electric Water Heater, 277 Volts HEAT240-208 NONE Tankless Electric Water Heater, 240/208 Volts No Valve Option Selected Color of Terreon Bowl/Sprayhead Cover (select one) Standard Colors CHAR Charcoal Gray GRAPH Graphite COBBLE E-GRAY Cobblestone Empire Gray JADE Jade LANNON Lannonstone SS-1N NFD Sensor-Operated Soap Dispenser Soap Drilling Only No Soap Dispenser LONDON London Gray O-TAUPE Organic Taupe PEP-WHT Peppered White Designer Colors (available at an additional charge) (Non-cancelable, non-returnable) ARC-CHIP Arctic Chip CORN Cornfi eld MYSTIC-M Mystic Moss BLUESKY COFFEE Blue Sky Coffee Bean HILLSIDE Hill Side MOUNTAIN Mountain Top RIVER S-SAGE Riverstone Summer Sage TerreonRE Colors (available at an additional charge) (Non-cancelable, non-returnable) BIRCH-BARK Birch Bark FERN Fern MOONDUST Moon Dust DUSK Dusk Optional Selections MAIZE Maize OAT Oat SAND No Faucet Drilling Sandtrap WHT-SAND White Sand STAR-D Stardust OCEAN-MIST Ocean Mist OLIVE Color of Trap Cover (select one) TC-GRAY Gray TC-PUTTY Putty TC-COAL Coal TC-STEEL Stainless Steel Mounting BRKT Surface-Mounted Bracket (Instead of carrier by others) P-Trap S-CHROME Single Chrome-Plated P-Trap Olive Page 7 of 7