SS-2N Express Lavatory System SS-Series

Similar documents
Express Lavatory System SS-Series

SS-3N Express Lavatory System SS-Series

SS-1N Express Lavatory System SS-Series

TDB3105 Terreon 36" Circular, 7-1/2" Deep Bowl Washfountain

TDB3104. Terreon 54" Semi-Circular, Deep Bowl Washfountain

FL-2H, FL-2L Frequency Lavatory System FL-Series

Express Lavatory System MG-Series

Express Lavatory System MG-Series

DISCONTINUED. LA75 Advocate Lavatory System LA-Series. Specifications. Code Compliance and Certifications. Construction

SN2003, SN2023, SN2004, SN2024 Sentry Semi-Circular Shallow Bowl Washfountain

AV60 Advocate Lavatory System AV-Series

AV30 Advocate Lavatory System AV-Series

SN2003, SN2023, SN2004, SN2024 Sentry Semi-Circular Shallow Bowl Washfountain

AV60 Advocate Lavatory System AV-Series

WF3204. Extra Height 54" Terreon Semi-Circular Washfountain. Specifications

AV60 Advocate Lavatory System AV-Series

AV90 Advocate Lavatory System AV-Series

SN2013, SN2033 Sentry Corner Shallow Bowl Washfountains

SN2003, SN2023, SN2004, SN2024

LD-5010 OmniDeck with WashBar 5000 Series

SN2005, SN2008 Sentry Circular Shallow Bowl Washfountain

WF2613 Classic Corner Washfountain with 9" Deep Bowl

FL-1H, FL-1L Frequency Lavatory System FL-Series

WF2613 Classic Corner Washfountain with 9" Deep Bowl

FL-3H, FL-3L Frequency Lavatory System FL-Series

WF Model Classic Washfountains Pre-Assembled Semi-Circular and Circular with 9" Deep Bowl

DISCONTINUED. Installation. SS-2N/ndt/STD SS-2N/ndt/WH. Express Lavatory System SS-Series. Table of Contents

WF2503, WF2504, WF2505, WF2508 Terreon Classic Washfountains

Installation SS-3N/IR/STD SS-3N/IR-WH. Express Lavatory System SS-Series. Table of Contents

WF2803, WF2804, WF2805, WF2808 Bradstone Classic Washfountains

Installation. SS-2N TouchTime (Standard and Wall-Hung) Table of Contents. Express Lavatory System SS-Series

WF2803, WF2804, WF2805, WF2808 Bradstone Classic Washfountains

WF2603, WF2604, WF2605, WF2608 Terrazzo Classic Washfountains

Installation. SS-3N Infrared (Standard and Wall-Hung) Table of Contents. Express Lavatory System SS-Series

For Service Only. Installation Instructions SS-3/IR/WH97. Express Lavatory System SS-Series

For Service Only. Installation Instructions. SS-3/AZ/WH97 Express Lavatory System SS-Series

WF2803, WF2804, WF2805, WF2808 Bradstone Classic Washfountains

Installation Instructions OBSOLETE

Installation CRS-2/IR, CRS-3/IR WARNING IMPORTANT. Table of Contents. Express Crescent Lavatory System CRS-Series

Installation MG-2/IR. Express Lavatory System - MG Series with Adaptive Infrared Control. Table of Contents

For Service Only. Installation Instructions EXD-2/STD EXD-2/JUV. Express Deck Lavatory System EXD Series

BRADLEY CORPORATION WASH FOUNTAINS Page 1 of 8

LVQD3 Verge with WashBar Technology LVQ-Series

LVSD2 Verge Wash Basin LVS-Series

LVQD3 Verge with WashBar Technology LVQ-Series

LVSD2 Verge Wash Basin LVS-Series

For Service Only. Installation Instructions EXD-3/WH97. Express Deck Lavatory System EXD Series

LVQD1 Verge with WashBar Technology LVQ-Series

DISCONTINUED. Installation LD OmniDeck Series. Table of Contents

Washfountain Application Guide

Installation LVRD1 IMPORTANT! Verge Lavatory System LVRD-Series with Evero Natural Quartz Material. Table of Contents

Model Z TAS. Standards Compliance. Sundara Drift Double Basin Hand Washing System

LA45 DISCONTINUED IMPORTANT!

LVRD3. Verge Lavatory System LVRD-Series with Evero Natural Quartz Material WARNING

LA90 DISCONTINUED IMPORTANT!

WARNING. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi.

LA60 DISCONTINUED IMPORTANT!

Installation TDB3103 WF3203. Table of Contents. Terreon 36" Semi-circular Deep Bowl Washfountain with TouchTime Control

Terreon WARNING. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi.

Installation. MG-2 TouchTime. Express Lavatory System - MG Series with TouchTime Metering. Table of Contents

Model Z Sundara Reef Triple Basin Hand Washing System

Model Z Sundara Float Double Basin Hand Washing System

School Solutions Ideabook

Terreon WARNING. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi.

PAT BASIN MODEL 9121, 9131, & 9141

Installation LVSD2. Table of Contents. Verge Lavatory System LVS-Series with Evero Natural Quartz Material

WARNING. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi.

Installation TDB3104 WF3204. Table of Contents. Terreon 54" Semi-Circular Deep Bowl Washfountain with TouchTime

Installation TDB3105 IMPORTANT! Table of Contents. Terreon 36" Circular Deep Bowl Washfountain with Infrared Control

Installation LD3060. OmniDeck Series. Table of Contents Rev. R; ECM Bradley Corporation Page 1 of 10 3/30/11

? Teflon Tape? 9/16 Fixture Wall Anchors and. ? 9/32 Fixture Wall Anchors and

WAW-2311 WAW-2322 WAW SERIES LAVATORIES

SPEAKMAN SAFETY PRODUCTS Installation, Maintenance & Operation Instructions SEF-18XY, EYESAVER FAUCET with SENSORFLOW, Battery or AC POWER

MERIDIAN MODEL# 3793

Durability within reach

INSTALLATION, OPERATIONS & MAINTENANCE MANUAL

Installation LVAD2. Table of Contents. Verge Wash Basin LVA-Series with Evero Natural Quartz Material

LC500. Patient Care Unit, 29", Fixed Water Closet. Specifi cations Standard Equipment

WARNING NOTICE. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi. IMPORTANT

Terreon Lav Decks WARNING

Automatic Temperature Controller (ATC)

BRADLEY CORPORATION DOMESTIC WATER PIPING SPECIALTIES Page 1 of 9

Installation LVQD2. Table of Contents. Verge Lavatory System LVQ-Series with WashBar Technology

Installation Instructions

ESS-2200 Double Station Scrub Sink. with Two Sensor Operated Gooseneck Spout. ESS-3200 Deluxe Double Station Scrub Sink

HL45, HL80 Thermostatic High-Low Valves

Ligature Resistant Sensor Faucet Patent # US D635,386 #SAL-5011/SF370

DUKE UNIVERSITY CONSTRUCTION STANDARDS

BRADLEY HALO EMERGENCY PLUMBING FIXTURES (Short Form Version)

TABLE OF CONTENTS. BARIATRIC SINKS & TOILETS Specially engineered fixtures designed to withstand loads typical in bariatric care environments.

A. Section Joint Sealants: Seal fixtures to walls and floors.

IMPORTANT. Wash Basin 1.0 Installation. Installation instructions for models:

Commercial washroom innovation. 90 years as the leading source of innovative solutions for all washroom design challenges. bradleycorp.

Installation LVQD1. Table of Contents. Verge Lavatory System LVQ-Series with WashBar Technology

Installation Instructions

Installation Instructions

Installation Instructions

Kitchen Faucets. KPS3029 Shasta

HOT WATER WITH THE SNAP OF A FINGER. Mini Tanks. Basic Heaters. High Capacity Heaters. Model CMT. Model SR, M & E. Model ER Series

7000BT Eye/Face Washes

Transcription:

ADA, ANSI and UFAS Compliant Serves One or Two Users at a Time Continuous owl is Constructed of Vandal Resistant Terreon or Terreon RE Solid Surface Material Available in 32 Terreon or TerreonRE Colors Reliable Plug-in, attery or ndite Infrared Activation, Push utton Air Valve, or TouchTime Metering Control Optional Electric Tankless Water Heater Specifications Accommodates one or two users. These units handle washroom traffic quickly and economically, while providing each user with their own personal space. The lavatories for the Express system are positioned on 30" centers. The preassembled sprayhead module is equipped with independent aerators each served by a separate infrared sensing module and solenoid valve (Model SS-2N/IR) or (Model SS-2N/NDT), a push button air metering valve (Model SS-2N/AST4), an independent battery IR sensor and batteries (Model SS-2N/IR3) or a push button TouchTime electronic metering valve (Model SS-2N/TT). Standard flow rate of.5 GPM meets industry standards for water conservation while providing enough water to rinse hands quickly and efficiently. Operating range is 20 80 PSI. Flow restrictor keeps flow rate constant at all pressures. Construction owl/sprayhead Cover Constructed of Terreon, a densified solid surface material composed of polyester resin, or TerreonRE, a densified solid surface material composed of a bio-based resin and preconsumer recycled granules. Terreon and TerreonRE are resistant to chemicals, stains, burns and impact. Surface damage can be easily repaired with everyday cleansers or fine grit abrasives. Terreon and TerreonRE are certified by NAH to meet ANSI Z124.3, Z124.6 and ANSI/ICPA SS-1. Terreon and TerreonRE are GREENGUARD certified as low-emitting materials. Pedestal Panels & Sprayhead ody Access panels are composed of vacuum-formed acrylic laminate. Sprayhead bodies are injection molded poly-blend. Highly resistant to impact, abrasion, acid and corrosion, the parts will not dent, chip, peel or flake. Support Frame owl assembly and panel are secured to a heavy gauge stainless steel support frame mounted to the wall. Standard frame (floor unit) includes scuff base. Vandal Resistance The molded sprayhead is an integral part of the bowl module. Its concealed vandal resistant streamformers discourage abuse. The infrared sensor will automatically shut off water flow after 30 45 seconds if a vandal attempts to trigger constant operation by covering the sensor or by placing a stationary object in the sensor s detection area. Push buttons are secured to the unit from inside the sprayhead. Air valves, water supplies, control boxes, and waste are concealed within the pedestal/support frame assembly. SS-2N/TT/WH/LSD-2 Code Compliance and Certifications ANSI Standards Terreon and TerreonRE are certified by NAH to meet ANSI Z124.3, Z124.6 and ANSI/ ICPA SS-1. cupc Approval Express Lavatory Systems are Uniform Plumbing Code (UPC), International Plumbing Code (IPC) and National Plumbing Code of Canada (NPC) approved through the International Association of Plumbing and Mechanical Officials (IAPMO). Manufactured in compliance with IGC 156, CSA 45 Series (R08) & ASME A112.18.1/CSA 125.1. This plumbing fixture is designed for hand washing only. It is not Intended to dispense water for human consumption through drinking or for preparation of food or beverages. Standard Frame The standard frame on the Express SS-Series includes a scuff base and is designed to comply with all ADA guidelines on reaches, clearances and operation for adult users. Wall-Hung Frame The wall-hung frame on the Express SS-Series (less scuff base above) is designed to mount at different heights (adult and children) to comply with guidelines on reaches, clearances and operation for various codes including, ADA Accessibility Guidelines for uildings and Facilities (ADAAG) and TAS (Texas Accessibility Standards). Always check your local and state codes. CERTIFIED PRODUCT 301-249-4000 www.nahbrc.org Page 1 of 6

Standard Equipment owls owl with two lavatories, pedestal, stainless steel mounting frame (as described above), and the following fittings: P-trap; tailpiece; two flexible stainless steel supply connections; and Navigator thermostatic mixing valve with stop valves, and 110/24 VAC plug-in transformer (Model SS-2N/IR and SS-2N/TT only). atteries are included in Model SS-2N/IR3. Activation Controls Infrared Sensor (Model SS-2N/IR) Each of the aerators is controlled by a separate solenoid valve. Hands placed within the bowl are detected by an infrared sensor module which activates a flow of tempered water from one station. Shut-off is automatic after hands are removed from the detection area. The infrared sensor uses a conical shaped transmitting beam, having a detection area adapted to, but not exceeding the bowl perimeter. The detection area projects forward 15 to each side and 15 below horizontal. The adaptive infrared sensor automatically adapts to the bowl after power is turned on. The infrared sensor is not affected by varying color tones or darkness. Direct sunlight or bright washroom lights will not activate the system. Infrared models also include solenoid valves and a low voltage transformer as standard equipment: Solenoid - 24V, 50/60 Hz, 3 8" NPT. Few moving parts, and resistant to most chemicals, minerals and impurities often present in municipal water supplies. Low Voltage Transformer - Class II UL/CSA listed, 110/24 VAC plug-in transformer. Plugs into a standard GFCI protected electrical outlet. Air Valve Hand Control (Model SS-2N/AST4) Each push button pneumatically actuates a non-hold-open, air metering, single temperature valve with field adjustable timing from 0 45 seconds. Factory preset at 10 seconds. Each push button activates one valve which, in turn, activates one station. TouchTime Metering Control (Model SS-2N/TT) Each low voltage push button actuates a non-hold-open, slow closing anti-hammer solenoid valve that is timed from an electronic potted assembly. Each push button activates one valve, which, in turn, activates one station. TouchTime controls water flow at each station through the use of solid-state, digital circuitry. Timing is electronically controlled at 15 seconds. attery Infrared Sensor (Model SS-2N/IR3) Each battery-powered sensor uses a zone-focused infrared transmitting beam, creating a large detection area not exceeding the bowl perimeter. The sensor is not affected by varying skin tones or darkness. When hands enter the detection area, the sensor starts water flow by opening the valve electronically. When hands leave the detection area, the sensor stops the flow of water by closing the electronically activated solenoid valve. The 6-volt DC, electronically activated solenoid valve has few moving parts, providing reliable operation that is unaffected by most chemicals and minerals often present in municipal water supplies. Each station is powered by a single lithium battery. attery type is Duracell DL 223A 6-volt lithium or equivalent (batteries included) with a life expectancy of 4 5 years or approximately 200,000 cycles. ndite Infrared Control (Model SS-2N/NDT) The photovoltaic cells are permanently embedded in the top of the sprayhead with a clear version of Terreon or TerreonRE. The ndite power management module is a proprietary unit that stores and provides power to the sensors and solenoid. This efficient module allows the system to work without batteries, eliminating the need to change or dispose of batteries. Each ndite-powered sensor uses a conical shaped transmitting beam, having a detection area adapted to, but not exceeding the bowl perimeter. The detection area projects forward 15 to each side and 15 below horizontal. The adaptive infrared sensor automatically adapts to the bowl after power is turned on. The electronically activated solenoid valve has few moving parts, providing reliable operation that is unaffected by most chemicals and minerals often present in municipal water supplies. Each lavatory system is powered by one ndite power management module. Restrooms with 400 lux of lighting will provide a sufficient amount of light to power the system. For more information on ndite technology, visit. Optional Equipment Thermostatic Electric Tankless Water Heater The optional tankless electric water heater is equipped with a microprocessing temperature control capable of maintaining outlet temperature accuracy of +/- 1 F. Factory preset at 105 F. Flow switch activates heater only on demand with 99% efficiency. For easy service, the heater features a replacement cartridge element. Heaters not available with IR3 or NDT activations. Model KW VAC Amps Temp. Rise @ 1 GPM EX95TML 9.5 240/208* 40 65 F EX100TML 10 277 36 68 F *240 volt can also be rated 208 volts with a 25% reduction in power. Terreon and TerreonRE Waste Receptacles Terreon and TerreonRE Waste Receptacles, Model SS-WR, feature a solid surface cover and vacuum-formed acrylic laminate base. The waste receptacle with Terreon or TerreonRE covers comes equipped with support brackets and mounting hardware. Install this Waste Receptacle between Express Lavatory Systems or at the end of an alcove. For more information on Terreon and TerreonRE Waste Receptacles for the Express SS-Series, visit www.. Soap Dispensers The Express SS-Series features an optional soap dispenser. Each hi-impact polymer tank is gravity-fed with a vertically mounted chrome plated brass valve. For refilling, the soap tank is easily removed from the sprayhead body by releasing a concealed, tamper-resistant leaf spring, which locks the tank in place. The soap valve will dispense vegetable/coconut oil liquid soaps, synthetic detergents, viscous lotion soaps and antiseptic solutions. Soap tank capacity is ¾ gallon. Page 2 of 6 Protected by one or more of the following U.S. patents: 5,611,093, D447,224, and D511,821. Other patents pending.

Dimensions - Top and Front Views 50" (1270mm) Top View 8" (203mm) Radius 15" (381mm) 15" (381mm) 10" (254mm) Radius 38¼" (972mm) Front View Standard Frame 7" (178mm) 21¼" (540mm) 30" (762mm) 36" (914mm) Front View Wall-Hung Frame 38¼" (972mm) 7" (178mm) 30" (762mm) 36" (914mm) Page 3 of 6

Dimensions - Side Views Standard Height at Standard Height 38½" (978mm) 34" (864mm) 30" (762mm) 13¼" (311mm) 3" (76mm) Scuff ase on Standard Height Only 38½" (978mm) 34" (864mm) 30" (762mm) 13¼" (311mm) at Juvenile Height Ages: 6 through 12 35½" (902mm) 31" (787mm) 27" (686mm) 10¼" (260mm) at TAS Height Grades: 6 through 8 or 9 at TAS Height Grades: Pre-K through 5 or 6 36½" (927mm) 32" (813mm) 28" (711mm) 34½" (876mm) 30" (762mm) 26" (660mm) 11¼" (286mm) TAS 9¼" (235mm) TAS Page 4 of 6

Rough-Ins Mounting for Standard and Wall Hung Heights Are Shown 23½" (597mm) 13¼" (337mm) 23½" (597mm) 9 3 8" (264mm) 9 3 8" (264mm) A A 3" (76mm) 4" (102mm) 32" (813mm) F D 4" (102mm) G D E Cold or Tempered Supply H 28¾" (730mm) 34" (864mm) Rim Height See Chart 1 25¾" (654mm) Hot Supply 20" (508mm) 19" (483mm) 2" (51mm) 13" (330mm) 22" (559mm) 15" (381mm) C C 3½" (89mm) Chart 1 Rim Vertical Height Adjustments Height Codes A,, C, D, E, F, G and H Fixture Style 34" None Standard Height 34" None Wall Hung 32" Subtract 2" TAS, Grades 6 through 8 or 9 31" Subtract 3" Juvenile Height 30" Subtract 4" TAS, Pre-K through Grades 5 or 6 Page 5 of 6 Chart 2 Code Description Qty. A 3 8" owl Wall Anchors with a minimum pull out force of 1,000 lbs. 2 3 8" Main Frame Wall Anchors with a minimum pull out force of 1,000 lbs. 4 C 3 8" ase Frame Wall Anchors with a minimum pull out force of 1,000 lbs. Standard frame option only 2 D ½" Nominal Copper Tubing for Hot/Cold Supplies, Stub-Out 2" from Wall 2 E 1½" NPT Drain, Stub-Out 2" from Wall 1 F 110V GFCI Protected Electrical Outlet. I.R. and TouchTime Only 1 G Optional Heater, Electric ox Location 4" L x 4" W x 4" H Option 1 1 H Optional Heater, Electric ox Location 4" L x 4" W x 8" H Option 2 1

Standard Selections (Must select one from each category) Sprayhead IR AST4 TT IR3 NDT Sprayhead w/infrared Control Sprayhead w/air Valve Control Sprayhead w/touchtime Control Sprayhead w/attery Infrared Control Sprayhead w/ndite Infrared Control * Pedestal (select one) STD Standard Frame (Includes Scuff ase) WH Wall-Hung Frame Soap Dispenser (select one) LSD-2 Liquid Soap Dispenser (SS-2N) NSD No Soap Dispenser Water Supply (select one) TMA Navigator Themostatic Mixing Assembly (Hot and Cold Supplies) TL Single Tempered Line Color of Terreon owl/sprayhead Cover (select one) Standard Colors E-GRAY ONE PEP-WHT SAND DS-WHT CHAR JADE Empire Gray Mesa one Peppered White Sandtrap Designer White Charcoal Gray Jade GRAPH LANNON COLE WHT-SAND FIESTA LONDON O-TAUPE Designer Colors* (available at an additional charge) ARC-CHIP Arctic Chip COFFEE S-SAGE Summer Sage CORN RIVER Riverstone LUESKY MYSTIC-M Mystic Moss HILLSIDE STAR-D Stardust MOUNTAIN TerreonRE Colors* (available at an additional charge) IRCH-ARK irch ark MAIZE Maize DUSK Dusk MOONDUST Moon Dust OLIVE Olive FERN Fern OAT Oat Color of Access Panel/Sprayhead ody (select one) GRAY COAL Gray Coal PUTTY Optional Selections Heaters (Not Available with IR3 or NDT Activations): Heat277 Electric Tankless Water Heater, 277 Volts Heat240-208 Electric Tankless Water Heater, 240/208 Volts P-Trap: S-CHROME Single Chrome-Plated P-Trap *Non-cancelable, non-returnable Graphite Lannonstone Cobblestone White Sand Fiesta London Gray Organic Taupe Coffee ean Cornfield lue Sky Hill Side Mountain Top OCEAN-MIST Ocean Mist Putty Page 6 of 6