DT1101A / DT1102A / DO110xA Automatic fire detectors

Similar documents
DM1101 / DM1103 / DM1104 DM1103-L / DM1103-S Manual call points Manual release button and emergency stop button

OH720, OP720, HI720, HI722

DB110xA, DB1131A, SO620A, DB1151A Detector bases and accessories

FDOOT241-A3, FDOOT241-A4, FDOOT241-A5, FDOOT241-A9, FDOOT241-8

FDOOT221, FDO221, FDT221

FDOOT241-A9-Ex Multisensor fire detector

FDF Sinteso Cerberus PRO Cerberus FIT. Flame detector. Flame detector addressed or collective, ASAtechnology TM

ASA linear smoke detector

FDOOT241-9, FDOOT241-A, FDO241, FDT241

OOH740, OOHC740. Cerberus PRO. Automatic fire detectors

DC1192 Input /Output module

DF1101-Ex Infrared flame detector

DM1131 / DM1133 / DM1134 Manual call points

Manual call point. Sinteso Cerberus PRO FDM223H, FDM224H. 'Heavy Duty' manual call point addressed (FDnet/C-NET)

Input module, input/output modules

Multi line separator module

OOH740, OOHC740 Automatic fire detectors

OOH740-A9-Ex Multisensor fire detector

OOH740-A9-Ex Multi-sensor fire detector

Output module (230 V)

Fire & Security Products. Siemens Building Technologies Group

Input module, input/output module

Mimic display driver, LED ribbon cable

DBS721, DBS729 Sounder interbase, Sounder beacon interbase

13 tones to choose from, 2 programmable alarm levels Adjustable sound levels up to 93 dba

OH110, OP110, HI110 Automatic fire detectors

Radio fire detection system

Interbases. Sinteso FDSB221, FDSB228, FDSB229

DOW1171 / DCW1151 Radio fire detection system

Manual call points. Sinteso / Cerberus PRO FDM225, FDM226

FDS229-R / FDS229-A Alarm sounder with supplementary optical indication

FDCL221-M Multi line separator module

DF1151-Ex Infrared flame detector

DC1154 / DC1154-AA / DC1156-AA / DC1157-AA Input / Output modules

FDCW221 / DOW1171 / SMF121 SMF6120 (repair/replacement) Radio fire detection system

DM1153H-Ex / DM1154H-Ex Manual call point 'Heavy Duty'-Ex

Fire control panels FC360

Siemens aspirating smoke detector (ASD) for the addressed FDnet/C-NET detector line or for standalone operation

FDCIO223 (ES 45) Transponder

SWING radio fire detection system

FDM273 Radio manual call point Mounting

FDCL221-Ex Line adapter (Ex)

Synova TM product catalog.

FDBZ290 Air sampling smoke detection kit

SOL-LX-W, SOL-LX-C, RoLP-LX, RoLP Sounder, beacon, and sounderbeacon

XC10 Extinguishing control panels

FDBZ290 Air sampling smoke detection kit

FT2080 Fire terminal (Touch) Mounting Installation

FDCW241 Radio gateway Mounting

FT2080 Fire terminal (Touch) Mounting Installation

FDA241, FDA221 Siemens ASD

FC330A-ECO Auto-addressing analogue 1-Loop fire detection panel

XC10 combined fire detection and extinguishing control

QFM41.. Duct sensors QFM41.. AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

FC2040. Fire control panel. Sinteso. FS20 series, MP6

XC10 combined fire detection and extinguishing control

DC1136, DC1131-AA, DC1134-AA, DC1136-AA Input / Output modules

Thermal Reset Limit Thermostats Electromechanical TW according to DIN EN 14597

FDL241-9 Linear smoke detector Mounting Commissioning

FDA241, FDA221 Siemens ASD

FC722 Fire control panel

FC724 Fire control panel

FC722 Fire control panel

Frost Protection Thermostat

Fire control panels FC726 FC726-XA

Room thermostat with 24-hour time switch and large LCD

Duct Temperature Sensors

FC724 Fire control panel

Cerberus FIT conventional system

OH110, OP110, HI110. Automatic Fire Detectors. Automatic Fire Detector For collective and conventional detector lines

FDCL221 Line separator

Electronic timeswitch

QAF63.2-J QAF63.6-J. Frost detectors. for use on the air side

Test units and accessories

This document is a preview generated by EVS

Technical description

QXA2100. Condensation monitor QXA2101. Monitor to prevent damage caused by condensation on chilled ceilings and HVAC plants with AC/DC 24 V power.

Room Temperature Controllers

MULTISENSOR SMOKE AND HEAT DETECTOR DMP-100 OPTICAL SMOKE DETECTOR DRP-100 FIXED TEMPERATURE / RATE-OF-RISE HEAT DETECTOR DCP-100

TLS 600. Installation and Operation Manual. English Pages CEDES AG is certified according to ISO 9001: V 1.0.

FC2020 Fire control panel

FP120-Z1 Power supply kit A (70 W) Technical Manual

Duct Air Quality Sensors

Flush-mounted room thermostat

OH720, OP720, HI720, HI722 Automatic fire detectors Technical Manual

For internal use only. Distribution (please mark): Product Solution Multi-channel x

FDM221, FDM223, FDM224, FDM223H, FDM224H Manual call points

ISO INTERNATIONAL STANDARD. Fire detection and alarm systems Part 16: Sound system control and indicating equipment

Building Technologies

Answers for infrastructure. Cerberus PRO enjoy protecting

FC723 Fire control panel

Fire control panel for modernization

Frost Units for air temperature monitoring

Install intelligent room automation flexibly and future-proofed

Room thermostats with LCD RDD100..

Universal Dimmer N 528D01, 2 x 300VA, AC 230 V 5WG DB01

FDCI221, FDCIO221 Input module, input/output module Technical Manual

Installation Guide. Ceiling PIR Detector (311) Features and Connections

ISO INTERNATIONAL STANDARD. Fire detection and alarm systems Part 3: Audible alarm devices

RVL479. Heating Controller. for use with a partner unit

Transcription:

DT1101A / DT1102A / DO110xA Automatic fire detectors collective/synoline600 AlgoRex Synova High degree of reliability and stability Compatible with all control units with collective/synoline600 detector evaluation High resistance to electromagnetic interference humidity and corrosion Modern design Blends well with every room decor Environmentally safe material halogen-free plastic material identifiable through embossed code easy to uninstall and disassemble Comprehensive final examination and quality control Control Products and Systems

Smoke detectors DO1101A / DO1103A / DO1104A, collective wide spectrum Uniform response behavior for different types of fire New, high performance optoelectronic sensor system High resistance to soiling and temperature fluctuation Heat detectors DT1101A / DT1102A Function Penetrating smoke scatters the light of an infrared beam in the detector. If the light scatter exceeds a certain value, the detector transmits a danger signal to the control unit. Built-in alarm indicator provides on-site signaling of alarm. Application DO1101A: for the early warning of smoke-forming flaming fires and smoldering fires. DO1103A: with considerably higher response sensitivity for use in air sampling smoke detection systems. DO1104A: with higher response sensitivity for the early warning of smoke-forming flaming fires and smoldering fires. For applications in hospital rooms, archives, museums, etc. Precise maximum temperature alarm activation with quality thermo sensor Response behavior immune to deceptive phenomena with rapid and slow increases in temperature Intelligently designed differential characteristics DT1101A: Heat detector with wide application range (up to +50 C) DT1102A: Heat detector for high ambient temperatures (up to +70 C) Function The detectors measure the ambient temperature with one NTC thermistor and the detector housing temperature with another NTC thermistor. In this way the detectors can rapidly and differentially evaluate an increase in temperature independent of the starting temperature. Upon exceeding the specified threshold value or upon exceeding the corresponding maximum temperature, the detectors transmit a danger signal to the control unit. Built-in alarm indicator provides on-site signaling of alarm. Application DT1101A: for the monitoring of rooms and installations where in the event of fire, a rapid increase in temperature can be expected, or other types of detector cannot be used due to operational reasons. DT1102A: for the monitoring of rooms and installations in which high ambient temperatures can be expected (up to + 70 C). 2

Design Mounting with detector base DB1101A. Range of base accessories for installation even in critical locations. Connection to the control unit via a two-wire line. Vibration-proof mounting of detector in the base. Anti-theft device can be built in if required. Two external alarm indicators can be connected. Maintenance DO1101A / DO1104A / DT1101A / DT1102A Detectors can be inserted and removed from their bases with a detector exchanger up to a height of 7 m. DO110xA By means of a periodic factory overhaul (cleaning and re-calibration), smoke detectors are given a new lease of life. Dimensions Ø 115 47...70 Ø 115 47...70 51 54.5 DO110xA with base DB1101A DT1101A/02A with base DB1101A 3

Technical data DO1101A DO1104A DO1103A DT1101A DT1102A Operating voltage 16 24 VDC 16 24 VDC 16 24 VDC 16 24 VDC Operating current (quiescent) max. 100 ma max. 100 ma max. 100 ma max. 100 ma Operating temperature -25 +60 C -25 +60 C -25 +50 C -25 +70 C Storage temperature -30 +75 C -30 +75 C -30 +75 C -30 +75 C Humidity 95 % rel. 95 % rel. 95 % rel. 95 % rel. Protection category IP44 IP44 IP44 IP44 IEC629 Color white, ~RAL 9010 white, ~RAL 9010 white, ~RAL 9010 white, ~RAL 9010 Standards EN 54-7 EN 54-5: A1R EN 54-5: B Approvals VdS LPCB DO1101A / DO1104A G2940 / 1161a/01 / - 1161c/01-1161c/03 Connection factor KMK 1 1 1 1 Compatibility Compatible with all control units with collective/synoline600 detector evaluation QS Standards Fire protection industry certified quality assurance system according to EN ISO 9001:2000 0786 DO1101A DO1101A - Point type smoke detector for use in fire detection and fire alarm systems installed in buildings. 3/2011/EU (CPR): EN 54-7 ; 2004/108/EC (EMC): EN 50130-4 / EN 61000-6-3 Technical data: see doc. 001001 DoP No.: 0786-CPR-20136; DoC No.: CED-DO1101A 0786 DO1104A DO1104A - Point type smoke detector for use in fire detection and fire alarm systems installed in buildings. 3/2011/EU (CPR): EN 54-7 ; 2004/108/EC (EMC): EN 50130-4 / EN 61000-6-3 Technical data: see doc. 001001 DoP No.: 0786-CPR-20077; DoC No.: CED-DO1104A 0786 DT1101A DT1101A - Point type heat detector for use in fire detection and fire alarm systems installed in buildings. 3/2011/EU (CPR): EN 54-5 ; 2004/108/EC (EMC): EN 50130-4 / EN 61000-6-3 Technical data: see doc. 1039 DoP No.: 0786-CPR-20079; DoC No.: CED-DT1101A 0786 DT1102A DT1102A - Point type heat detector for use in fire detection and fire alarm systems installed in buildings. 3/2011/EU (CPR): EN 54-5 ; 2004/108/EC (EMC): EN 50130-4 / EN 61000-6-3 Technical data: see doc. 1039 DoP No.: 0786-CPR-20094; DoC No.: CED-DT1102A 4

Details for ordering Type Part no Designation Weight DO1101A BPZ:4930020001 Smoke detector 0.160 kg DO1103A BPZ:4945800001 Smoke detector 0.160 kg (for air sampling smoke detection systems) DO1104A BPZ:5090640001 Smoke detector 0.160 kg (with higher response sensitivity) DT1101A BPZ:4931700001 Heat detector 0.140 kg DT1102A BPZ:4931830001 Heat detector 0.140 kg Base and base accessories see document 001035 5

Issued by Siemens Switzerland Ltd Division International Headquarters Gubelstrasse 22 CH-6301 Zug Tel. +41 41 724 24 24 www.siemens.com/buildingtechnologies Siemens Switzerland Ltd, 2015 Technical specifications and availability subject to change without notice. Document no. 001578_m_en_-- Manual S11 / FD-C Edition 2018-07-02 Section 2 / 3