Test report no.: Plug and key - Damp heat test

Similar documents
Test Report to AS/NZS :2015. Report No. T160402_S

SUPPLEMENT REPORT No.: XPL/13600/

INTERNATIONAL STANDARD

TABLE OF CONTENTS. 1.0 INTRODUCTION Scope References Test Specimen Description Summary 1

THINKING BEYOND THE OBVIOUS

SOUTH AFRICAN NATIONAL STANDARD

Ultrasonic Clamp-On Flow Meter Testing

INTERNATIONAL STANDARD

Furenflex RWV Advanced Liner

WYLE LABORATORIES, INC. Huntsville Facility

DEPARTMENT OF TRADE AND INDUSTRY DEPARTEMENT VAN HANDEL EN NYWERHEID. NATIONAL REGULATOR FOR COMPULSORY SPECIFICATIONS ACT (Act 5 of 2008)

SmartSensor 105 & Advance NEMA External Ice

Engineering Report Vibration Test for Intertek Testing Services Prepared by Approved by 9725 Girard Avenue South Minneapolis, MN 55431

SOUTH AFRICAN NATIONAL STANDARD

Test Report. Appliance EMF Testing

Fire-resistance test on fire collars protecting a concrete slab penetrated by services

INTERNATIONAL STANDARD

EU-Type Examination Certificate

Environment Test Report

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

WH-1404, Rev. Feb 97

SANS :2014 Edition 1 IEC :2012 Edition 1

INTERNATIONAL STANDARD

This document is a preview generated by EVS

CNBOP-PIB Standard Fire Protection

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Fire resistance test on fire collars protecting a concrete slab penetrated by services

31 March 2015 LW JELE (TECHNICAL SPECIALIST) NRCS Regulatory research and development

SOUTH AFRICAN NATIONAL STANDARD. Part 2-19: Particular requirements for the basic safety and essential performance of infant incubators

MS1471 SPECIFICATIONS. PC Board Mountable Pressure Sensor 0-60 mv Output Gage and Absolute Low Cost

AS/NZS :2012. Regulatory compliance mark for electrical and electronic equipment AS/NZS :2012. Part 1: Use of the mark

SANS :2014 Edition 1 IEC :2012 Edition 1

INTERNATIONAL STANDARD

A three-pole dead-tank SF 6 circuit-breaker incorporating one interrupter per pole in single-pole enclosures with a common operating mechanism

This document is a preview generated by EVS

Equipment specifications (D6)

Fire-resistance test on fire collars protecting a plasterboard wall penetrated by services

SOUTH AFRICAN NATIONAL STANDARD

ETSI TS V1.2.1 ( )

ETSI TS V1.2.1 ( )

INTERNATIONAL STANDARD

Product Specification Qualification Test Report

EIA STANDARD TP-38B EIA B. Cable Pull-Out Test Procedure for Electrical Connectors. EIA/ECA B (Revision of EIA A)

INTERNATIONAL STANDARD

Provläsningsexemplar / Preview INTERNATIONAL

Fire-resistance test on fire collars protecting a plasterboard wall penetrated by services

AS/NZS 3820:2009 (Incorporating Amendment 1) Essential safety requirements for electrical equipment

AS/NZS 3190:2011 AS/NZS

Sound Performance Rating of Outdoor Unitary Equipment

SOUTH AFRICAN NATIONAL STANDARD

This document is a preview generated by EVS

STANDARD FOR INDOOR-OUTDOOR OPTICAL FIBER CABLE

Michael J. Caron, Test Engineer. Lee R. Senne, Test Technician. Kent L. Erickson, Dynamics Division Manager

TECHNICAL REPORT Crimp Splice Protection -250M/P150 mark 2

Draft ES V1.1.1 ( )

safety requirements are to comply with this compulsory specification twelve (12) months after the publication of this notice.

Business Quality Assurance International Ltd

This document is a preview generated by EVS

SOUTH AFRICAN NATIONAL STANDARD

Standard SPECIFICATIONS FEATURES APPLICATIONS

SOUTH AFRICAN NATIONAL STANDARD

ENVIRONMENTAL TEST REPORT

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

E/ECE/324/Rev.1/Add.27/Amend.5 E/ECE/TRANS/505/Rev.1/Add.27/Amend.5

INTERNATIONAL STANDARD

This document is a preview generated by EVS

FINAL ATEX REPORT ON EQUIPMENT FOR USE IN POTENTIALLY EXPLOSIVE ATMOSPHERES FOR GOLDEN PROMISE EQUIPMENT INC. FLOW MONITOR, GPE3000 SERIES,

PCT Workshop Before you leave the office

Vibration tests on a TNAML Luminaire

Management Systems Certification Ltd

Certifikat och provningsprotokoll för art och 4511

INTERNATIONAL STANDARD

PQS Independent type-testing protocol

Medical electrical equipment

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

AS/NZS 4012:1999 AS/NZS

IFLA Regional Office for Latin America and the Caribbean: Call for Applications to host the Regional Office

This draft Tanzania Standard gives the general requirements and conditions for electrical tests to be performed on coaxial communication cables.

This document is a preview generated by EVS

Information Bulletin

TECHNICAL REPORT. Household high-fidelity audio equipment and systems Methods of measuring and specifying the performance

INTERNATIONAL STANDARD

This document is a preview generated by EVS

This is a preview - click here to buy the full publication TECHNICAL REPORT. Environmental testing

FDBZ290 Air sampling smoke detection kit

INTERNATIONAL STANDARD

MODEL 834M1 ACCELEROMETER

TABLE OF CONTENTS. 1.0 INTRODUCTION Scope References Test Specimen Description Summary 3

Loss Prevention Standard

INTERNATIONAL STANDARD

Provläsningsexemplar / Preview TECHNICAL REPORT. Part 3-1: Conformity verification report for IEC :2001 General requirements

Government Gazette Staatskoerant

Australian/New Zealand Standard

ELAF LOAD CELL SPECIFICATIONS FEATURES

Environmental testing Part 3-6: Supporting documentation and guidance Confirmation of the performance of temperature/humidity chambers

Shipboard incinerators with capacities up to 4000 kw

Transcription:

r Yebotech 14405.docx Test report no.: 14405 Plug and key - Damp heat test EDITION 1 PAGE 1 OF 4

Tel: +27 (0)12 371 2000 Fax: +27 (0)12 371 2001 www.gerotek.co.za WF Nkomo Street Pretoria West P O Box 7413 Pretoria 0001 South Africa Mr. Shayne Jones Company registration: 1968/008611/30 VAT registration: 439 016 0077 YeboTech (Pty) Ltd Tokai on main Business Park Date: 2017-02-22 TOKAI Enquiries: H Prinsloo 7966 Cell no.: 082 7703531 e-mail address: shayne.jones@yebotech.com e-mail address: henniep@gerotek.co.za Telephone No.: 021-713 7260 Report no.: 14405 STATEMENT OF AUTHORITY This report is issued in accordance with the conditions of approval granted by the South African National Accreditation System (SANAS) and without alteration. It is a correct record of measurements made at the time of testing. Copyright of this report is owned jointly by SANAS and Gerotek Test Facilities (GTF) and may not be reproduced other than in full except with prior approval of SANAS and GTF. This report relates only to the specific samples tested as identified herein. The test results do not apply to any similar item that has not been tested. GTF accepts no liability for losses or legal matters arising from misinterpretation, misunderstanding or misuse of this test report. TEST OFFICIAL: APPROVAL: H Prinsloo SANAS SIGNATORY R van den Berg TECHNICAL MANAGER 2017-02-22 2017-02-27 Date Date Directors: Vice Admiral (ret) RJ Mudimu (Chairman), Ms T Skweyiya, Mr KPE Wakeford (CEO), Dr M Khanyile, Adv VLA de la Hunt, Mr NM Tyibilika, Mr RM Vokwana, Mr JG Grobler (Chief Financial Officer), Adv NB Senne (Company Secretary) Customer Focus : Care and Respect for Others : Excellence : Integrity : Leading by Example : Results Driven : Teamwork EDITION 1 PAGE 2 OF 4

Test procedure used: Type of test(s): Test result: Test item description: Manufacturer: Model no.: Serial no.: Remarks: TEST INFORMATION IEC60068-2-30 - Environmental testing Part 2-30:Tests Test Db:Damp heat, cyclic (12 h + 12 h cycle) Third edition:2005-08 Damp heat test Compliant. Both the plug and key performed satisfactory during the tests. Plug and key YeboTech (Pty) Ltd YL15-Plug-01_B and YK15-KeyB-02 N/a None Date received: 2017-02-15 Test location: Gerotek Test Facilities Test commencement date: 2017-02-15 Test completion date: 2017-02-22 Test witnessed by: Ambient temperature: N/a 23 C ±6 C TABLE OF CONTENTS 1. TEST EQUIPMENT UTILISED... 4 2. TEST RESULTS... 4 2.1 DAMP HEAT TEST IN ACCORDANCE WITH IEC60068-2-30... 4 2.1.1 Results... 4 LIST OF APPENDICES Appendix A: Appendix B: Photographs Certificate of conformance EDITION 1 PAGE 3 OF 4

1. TEST EQUIPMENT UTILISED Type of Instrument Asset no. Calibration certificate no. Climatic chamber 13000062 C/2016/055 Traceability: All test equipment utilised to conduct tests were calibrated in terms of standards, the accuracy of which is traceable to the national measuring standards kept and maintained by the NMISA. 2. TEST RESULTS 2.1 Damp heat test in accordance with IEC60068-2-30 The Plug and Key was subjected to a damp heat test with the temperature cycled from +25 C to +55 C with the relative humidity constant above 90%. The plug and key were functionally tested prior to and upon completion of the test. The duration of the test was 6 x 24 hour cycles. The test was performed in accordance with figure 2a of IEC60068-2-30 test Db. See photographs and graph of Damp heat test in Appendices A and B. 2.1.1 Results The plug and key performed satisfactory during the functional test. END OF REPORT EDITION 1 PAGE 4 OF 4

Appendix A Photographs EDITION 1

Plug and Key The Plug and Key inside the chamber during the damp heat test EDITION 1 PAGE A1 OF A1

Appendix B Damp heat test graph EDITION 1

Damp heat test in accordance with Figure 2a of IEC60068-2-30 test Db EDITION 1 PAGE B1 OF B1

Appendix C Certificate of conformance EDITION 1

Tel: +27 (0)12 371 2000 Fax: +27 (0)12 371 2001 www.gerotek.co.za WF Nkomo Street Pretoria West P O Box 7413 Pretoria 0001 South Africa Shayne Jones Company registration: 1968/008611/30 VAT registration: 439 016 0077 YeboTech (Pty) Ltd Tokai on main Business Park Date: 2017-02-22 TOKAI Enquiries: H Prinsloo 7966 Cell no.: 082 7703531 e-mail address: shayne.jones@yebotech.com e-mail address: henniep@gerotek.co.za Telephone No.: 021-713 7260 Report no.: 14405 CERTIFICATE OF CONFORMANCE Test item description Model number Specification number Conformance result : Plug and key Remarks : None Test date : 2017-02-22 : YL15-Plug-01_B and YK15-KeyB-02 : IEC60068-2-30 - Environmental testing Part 2-30:Tests Test Db:Damp heat, cyclic (12 h + 12 h cycle) Third edition:2005-08 VESA- ABS 5001 06 Product specification for Vehicle Security Revision 05 : Compliant. Both the plug and key performed satisfactory during the tests. TEST OFFICIAL: APPROVAL: H Prinsloo TEST OFFICIAL R van den Berg TECHNICAL MANAGER 2017-02-22 2017-02-27 Date Date Directors: Vice Admiral (ret) RJ Mudimu (Chairman), Ms T Skweyiya, Mr KPE Wakeford (CEO), Dr M Khanyile, Adv VLA de la Hunt, Mr NM Tyibilika, Mr RM Vokwana, Mr JG Grobler (Chief Financial Officer), Adv NB Senne (Company Secretary) Customer Focus : Care and Respect for Others : Excellence : Integrity : Leading by Example : Results Driven : Teamwork EDITION 1 PAGE C1 OF C1