Installation LVSD2. Table of Contents. Verge Lavatory System LVS-Series with Evero Natural Quartz Material

Similar documents
LVRD3. Verge Lavatory System LVRD-Series with Evero Natural Quartz Material WARNING

Installation LVAD2. Table of Contents. Verge Wash Basin LVA-Series with Evero Natural Quartz Material

Installation LVRD1 IMPORTANT! Verge Lavatory System LVRD-Series with Evero Natural Quartz Material. Table of Contents

DISCONTINUED. Installation LD OmniDeck Series. Table of Contents

Installation CRS-2/IR, CRS-3/IR WARNING IMPORTANT. Table of Contents. Express Crescent Lavatory System CRS-Series

Installation LC800. Patient Care Unit, 47", Fixed Water Closet. Table of Contents

Installation. MG-2 TouchTime. Express Lavatory System - MG Series with TouchTime Metering. Table of Contents

Installation Instructions

Installation LD3060. OmniDeck Series. Table of Contents Rev. R; ECM Bradley Corporation Page 1 of 10 3/30/11

Installation WARNING SXWS9561. Stainless Steel Panel Shower

WARNING NOTICE. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi. IMPORTANT

Installation LC840. Patient Care Unit, 40", Fixed Water Closet. Table of Contents

Terreon Lav Decks WARNING

WARNING. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi.

Installation MG-2/IR. Express Lavatory System - MG Series with Adaptive Infrared Control. Table of Contents

LA90 DISCONTINUED IMPORTANT!

Terreon WARNING. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi.

LA45 DISCONTINUED IMPORTANT!

LA60 DISCONTINUED IMPORTANT!

Installation LVQD2. Table of Contents. Verge Lavatory System LVQ-Series with WashBar Technology

Terreon WARNING. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi.

Installation. SS-2N TouchTime (Standard and Wall-Hung) Table of Contents. Express Lavatory System SS-Series

WARNING. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi.

Installation. SS-3N Infrared (Standard and Wall-Hung) Table of Contents. Express Lavatory System SS-Series

For Service Only. Installation Instructions EXD-3/WH97. Express Deck Lavatory System EXD Series

For Service Only. Installation Instructions EXD-2/STD EXD-2/JUV. Express Deck Lavatory System EXD Series

Installation LVQD1. Table of Contents. Verge Lavatory System LVQ-Series with WashBar Technology

Installation TDB3105 IMPORTANT! Table of Contents. Terreon 36" Circular Deep Bowl Washfountain with Infrared Control

For Service Only. Installation Instructions. SS-3/AZ/WH97 Express Lavatory System SS-Series

Models: FM FM WARNING

Installation IMPORTANT! Bradley Multi-Station Wall Sink

Installation TDB3103 WF3203. Table of Contents. Terreon 36" Semi-circular Deep Bowl Washfountain with TouchTime Control

Installation TDB3104 WF3204. Table of Contents. Terreon 54" Semi-Circular Deep Bowl Washfountain with TouchTime

Installation Instructions OBSOLETE

For Service Only. Installation Instructions SS-3/IR/WH97. Express Lavatory System SS-Series

Installation. S Series Navigator Thermostatic Mixing Valve

LVSD2 Verge Wash Basin LVS-Series

Installation Instructions

Installation SS-3N/IR/STD SS-3N/IR-WH. Express Lavatory System SS-Series. Table of Contents

DISCONTINUED. Installation. SS-2N/ndt/STD SS-2N/ndt/WH. Express Lavatory System SS-Series. Table of Contents

Installation Instructions

PAT BASIN MODEL 9121, 9131, & 9141

Installation S

LVSD2 Verge Wash Basin LVS-Series

LVQD3 Verge with WashBar Technology LVQ-Series

Installation S

Installation S

Installation S

Installation Instructions

Installation Instructions

Installation S

LVQD3 Verge with WashBar Technology LVQ-Series

MERIDIAN MODEL# 3793

LVQD1 Verge with WashBar Technology LVQ-Series

Installation Instructions

Installation Instructions

Installation S HL2X2 High Capacity Manifold System. Table of Contents Rev. B; ECN Bradley Page 1 of 8 11/10/2014

Installation Instructions

Installation Instructions

Installation S19-324D1. Class I, Division 1, Groups C & D Explosion Proof. Emergency Signaling System

GRANITE COMPOSITE SINK

? Teflon Tape? 9/16 Fixture Wall Anchors and. ? 9/32 Fixture Wall Anchors and

Installation & Operation Manual

INSTALLATION, OPERATIONS & MAINTENANCE MANUAL

3/4.8 AERODYNE 3/4.8L CLASS FIVE+

Installation S IMPORTANT! Bradley Thermostatic Mixing Valve for Individual Showers. Table of Contents

Installation & Operation Manual

CARE & CLEANING GUIDE. Bathroom & Kitchen Products

FL-1H, FL-1L Frequency Lavatory System FL-Series

ACRYLIC PEDESTAL TUB

BARRINGTON PRESSURE LITE VITREOUS CHINA SIPHON JET TOILET K-4327

INSTALLATION INSTRUCTIONS

INSTALLATION AND CARE GUIDE MARCO VANITY FRAME BASE & SINKTOP E E E E052463

Installation & Operation Manual

Stainless Steel. Care and Cleaning. Mott Manufacturing Limited PO Box 1120 Brantford, Ontario N3T 5T3 Canada

SAN RAPHAEL PRESSURE LITE VITREOUS CHINA SIPHON JET TOILET

Installation and Maintenance Instructions

CARE & CLEANING GUIDE. Bathroom & Kitchen Products

FL-2H, FL-2L Frequency Lavatory System FL-Series

FL-3H, FL-3L Frequency Lavatory System FL-Series

Installation & Operation Manual

Assembly instructions. Alexandria Pedicare System ALEXANDRIA. Perfect design. Personal service.

Ligature Resistant. ADA Compliant

01694-REVC_081315_ENGLISH

WELLWORTH /HIGHLINE WITH PEACEKEEPER VITREOUS CHINA TOILET

KOHLER Care and Cleaning Guide

STAINLESS STEEL OFFSET DOUBLE BOWL SINK

INSTALLATION INSTRUCTIONS. Downtown Contempo Widespread Faucets Part # s: 8882-****, 8883-***

TSL-Aerofoil. wall mounted basin. installation + maintenance

FAQ s ABOUT TOPZERO STAINLESS STEEL SINKS: >What type of stainless steel does TopZero use?

INSTALLATION INSTRUCTIONS

Features Luxier SP21-SS

Features Luxier SP26-GS

AV30 Advocate Lavatory System AV-Series

MODENA ZUHNE

Features Luxier SP21-SS

Pocket Hardmount. Preventative Maintenance.

Decor Star 1. Decor Star PL-037-SS

ENGINEERED QUARTZ SINK Installation & Care Instructions

Installation Keltech S19361 Heater Safety Fixture Skid Keltech S19361F Freeze Protected Heater Safety Fixture Skid

Transcription:

LVSD2 Verge Lavatory System LVS-Series with Evero Natural Quartz Material Table of Contents Components...3 4 Supplies Required...5 Dimensions...5 6 Rough-Ins...7 Frame Mounting...8 Faucet Box and Valve Mounting...9 Overflow Plug ssembly...9 Drain ssembly...10 Faucets and Optional Soap Valve...10 Bowl Mounting...11 Strainer and P-trap...11 djust Temperature...12 Trap Cover...12 Cleaning and Maintenance...13 215-1829 Rev. B; ECN 16-08-008 2016 Bradley Page 1 of 12 6/6/2016 P.O. Box 309 Menomonee Falls, WI 53052 US 800 BRDLEY (800 272 3539) +1 262 251 6000 bradleycorp.com

LVSD2 WRNING Make sure that all water supply lines have been flushed and then completely turned off before beginning installation. Debris in supply lines can cause valves to malfunction. Turn OFF electrical power to the electrical outlets, then unplug all electrical units prior to installation. Electrical power MUST remain off until installation is complete. Installer's hardware must be appropriate for wall construction. Wall anchors must have a minimum pull-out rating of 1,000 pounds. IMPORTNT Read this entire installation manual to ensure proper installation. When finished with the installation, file this manual with the owner or maintenance department. Compliance and conformity to local codes and ordinances is the responsibility of the installer. Product warranties may be found under Products on our Web site at www.bradleycorp.com. Separate parts from packaging and make sure all parts are accounted for before discarding any packaging material. If any parts are missing, do not begin installation until you obtain the missing parts. For standard height mounting, do not exceed the recommended 33.5" distance from the fixture rim to the finished floor. 2 6/6/2016 Bradley 215-1829 Rev. B; ECN 16-08-008

LVSD2 Components Complete Drain Prepack (S45-2862) Bowl Contact your Bradley Representative for color options Prepack (S45-2861) Drain dapter Prepack (S45-2480) *Screw Strainer *Standoff, Hex, SS #6-32 x 1" O-Ring (125-111) Drain dapter Packing Washer #10-24 Screw *Screw #6-32 x 1-1/4" Pan *Included in Prepack S45-2778 ccess Panel (186-1905) Individual Rough-In Option Chrome P-trap (S29-094) Plastic P-trap (269-1697) Wall Bracket (140-1128) TMV Supply Connections Plastic Hose TMV Valve (1/2" NPTM Outlet) (S45-2701) Tempered Supply Connections Supply Fittings (S45-2511) Plastic Hose Plastic Hose Supply Fittings (S45-2510) Stainless Steel Hose Hose Prepack (S45-2731) Hose Prepack (S45-2730) Bradley 215-1829 Rev. B; ECN 16-08-008 6/6/2016 3

LVSD2 Components IR-DCD Faucet* (S53-336) Plug-In Transformer Option (PT) for IR-DCD Faucet (S53-337) IR-DCG Faucet* (S53-350) Plug-In Transformer Option (PT) for IR-DCG Faucet (153-486) *dapter S45-2872 included with faucet *dapter S45-2872 included with faucet CP-DC Faucet (S53-334) Plug-in transformer option (PT) includes Transformer (S53-338), dapter (S53-339), and Grounding Kit (S53-349) for CP-DC Faucets Battery Box for CP-DC Faucets Optional Transformer 6315-KT0000 Soap Dispenser 6324-68 Soap Dispenser 6334 Soap Dispenser 4 6/6/2016 Bradley 215-1829 Rev. B; ECN 16-08-008

LVSD2 Supplies Required (6) 3/8" fasteners and wall anchors (minimum pull-out rating of 1,000 lbs.) (2) 1/4" fasteners and wall anchors (minimum pull-out rating of 100 lbs.) 1/2" hot/cold or tempered stub-out(s) 1-1/2" NPT drain stub-out(s) OPTIONL: (2) 110 volt GFCI protected electrical outlets for 100 120 VC plug-in transformers only Screen filter(s) as needed, if not included with faucet(s) Dimensions Top View (shown with CP-DC faucet and 6315 soap as shared soap) 15" (381mm) 6" (152mm) 15" (381mm) 6" (152mm) 4-1/4" (165mm) 21" (533mm) 2" (51mm) = Personal soap locations Front View 60" (1524mm) 1-7/8" (48mm) 12-7/8" (327mm) 38-3/8" (975mm) Bradley 215-1829 Rev. B; ECN 16-08-008 6/6/2016 5

LVSD2 Dimensions Side View 13¹ ₈" (333mm) 18½" (470mm) 14" (356mm) 10¹ ₈" (257mm) B C D/TS Standard Height D/TS Juvenile Height (Children 6-12 years) CS Standard Height OBC Standard Height OD-2015 Standard Height Dim 33-1/2" (851mm) 31" (787mm) 33-1/2" (851mm) 33" (838mm) 32½" (826mm) Dim B 27" (686mm) 24" (610mm) 29-5/8" (752mm) 28-15/16" (735mm) 28-15/16" (735mm) Dim C 20-3/4" (527mm) 18-1/4" (464mm) 21-1/8" (536mm) 20-1/4" (514mm) 19-3/4" (502mm) 6 6/6/2016 Bradley 215-1829 Rev. B; ECN 16-08-008

LVSD2 Structural Rough-Ins Mounting for Standard, D and TS height shown. Points, B and C require sufficient backing compliant with local building codes. WRNING Ensure bowl is completely seated in the wall bracket and securely fastened to the wall at point. Wall Bracket 36-1/2" (927mm) C L Secure bracket to wall using min. (2) 3/8" anchor bolts to the left of C/L and min. (2) 3/8" anchor bolts to the right of C/L. The (2) anchor bolts to the right of C/L must be min. 16" apart from the anchor bolts to the left of C/L. When mounting is complete, check to ensure the bracket is level. See Step 1: Bracket Mounting for more information. 33-1/2" (851mm) Rim Height 31-1/2" (800mm) 25-1/2" (648mm) B C 28-1/2" (724mm) Bottom of Bracket 20" (508mm) 24" (610mm) 20" (508mm) 24" (610mm) C B CODE DESCRIPTION QTY. Install (1) 3/8" wall anchor with a minimum pull-out force of 1,000 lbs. per local codes at locations shown 2 B Provide structural backing compliant with local building codes. 2 C Install wall anchor with a minimum pull-out force of 100 lbs. per local codes at locations shown 2 RIM HEIGHT VERTICL HEIGHT DJUSTMENTS FIXTURE STYLE 33-1/2" No djustment Standard Height, D, TS and CS 30-1/2" Subtract 3" Juvenile, D and TS 32½" Subtract 1" OD 33" Subtract 1/2" OBC Bradley 215-1829 Rev. B; ECN 16-08-008 6/6/2016 7

LVSD2 Plumbing and Electrical Rough-Ins Mounting for Standard, D and TS height shown. (mm) 33-1/2" (851) Rim Height P E S H C P E 26" - 27" (660-686) 23" - 24" (584-610) 20" - 23" (508-584) 20-3/4" (527) 4" - 5" (102-127) 5-1/2" - 6-1/2" (139-165) 14" - 16" (355-406) 2-1/2" - 3-1/2" (64-89) 12" - 13" (305-330) 14" - 16" (355-406) CODE DESCRIPTION QTY. 1-1/2" NPT Drain, Stub-out 2" from wall, individual waste option 2 H,C 1/2" Nominal (5/8" O.D. Comp.) Hot/Cold supplies, Stub-out 2" from wall 1 E 110V GFI protected electrical outlet (C faucet and soap only) 2 S Outline of shared soap container (if selected) 1 P Outline of personal soap container (if selected) 2 8 6/6/2016 Bradley 215-1829 Rev. B; ECN 16-08-008

LVSD2 1 Bracket Mounting Typical installation is shown. It may be necessary to repair the wall after mounting. The fixture may not cover all of the wall modifications. Mounting height per structural rough-in dimensions. 16" (406mm) min. Install wall bracket to wall per structural rough-in dimensions. Check to ensure the bracket is level. Example anchor locations shown. C L 2 Drain ssembly For ease of drain installation, lay the bowl on its back. Thread the standoff onto the now fully engaged B screw. Standoff, Hex SS #6-32 x 1" O-Ring Thread screw into drain adapter until it becomes fully engaged. Drain dapter Packing Washer #6-32 x 1-1/4" Screw #10-24 Screw ssemble the remaining components as shown and thread the four screws through the drain adapter and into the basin inserts. C Ensure the screws compress the drain adapter evenly onto the basin. Bradley 215-1829 Rev. B; ECN 16-08-008 6/6/2016 9

LVSD2 3 Faucet For ease of drain installation, lay the bowl on its back. Install the faucets and optional soap valves according to the manufacturer's instructions. 4 Bowl Mounting (to Bracket and Wall) WRNING Ensure bowl is completely seated in the wall bracket and securely fastened to the wall at point. CUTION Bracket is not intended to support the weight of bowl for an extended period of time. Be sure to secure the bowl to the wall using appropriate fasteners. 5 Secure the bowl to the wall anchors using fasteners per the structural B rough-in requirement (supplied by installer). Strainer and P-Trap Ensure not to overtighten the strainer screw. Position bowl above wall bracket. Press firmly on the back of the bowl to seat the bowl flange into the wall bracket lip. Ensure bowl is level. Strainer Thread the strainer screw through the strainer and into the stand off on the drain adapter. Install supplied p-trap to B drain adapter. 10 6/6/2016 Bradley 215-1829 Rev. B; ECN 16-08-008

H LVSD2 6 djust Temperature with Water Running WRNING This valve is NOT factory preset. Upon installation, the temperature of this valve must be checked and adjusted to ensure delivery of a safe water temperature. Water in excess of 110 F (43 C) may cause scalding. Loosen Cap Screw about 1/4" (4-6 turns) and lift up cover (do not remove). B Using cover, turn cartridge gently until desired water temperature is reached. Do not turn past stops as this may damage unit. Push cover down and tighten screw. C 7 Trap Cover Make all connections before installing trap cover. ssemble and attach the trap cover hook as shown. Hang the trap cover B onto the center hook. E Secure the trap cover to the wall using screws provided by installer (2 locations). Secure the trap cover to the bowl using the screw and finishing D washer provided (2 locations). #10-24 Flat Head Screw (160-520) Finishing Washer (142-002C) Pivot the trap cover onto the bowl and secure the trap cover to the bowl gussets using the C screws and finishing washers provided (2 locations). Bradley 215-1829 Rev. B; ECN 16-08-008 6/6/2016 11

LVSD2 Cleaning and Maintenance for Evero Material Description: Evero Natural Quartz Material is made from a blend of acrylic modified bio-based polyester resin, natural quartz and other materials and is resistant to chemicals, stains, burns and impact. Surface damage can be easily repaired with everyday cleansers or fine grit abrasives. Routine Cleaning: For regular cleaning, use standard commercial or household products such as Simple Green, Creamy Cleanser brand, Formula 409 or Windex. Stubborn Stains: Remove tough stains, with non abrasive cleaners and pads such as a white Scotch Brite pad and Lysol. Special Situations for Evero Material Hard Water Deposits: Remove hard water deposits with a mild solution of vinegar and water. lways rinse the unit thoroughly after cleaning. Restoring the surface: Refresh and restore the rich surface with one of the following: Geo Series: Color enhancer such as Tenax ger Pearl Series: Impregnating sealer such as DryTreat Stain - Proof Original or Miracle Sealants 511 Impregnator NOTICE! Do not use strong acid or alkaline chemicals and cleansers to clean Evero. If these chemicals come in contact with the surface, wipe them off immediately and rinse with soapy water. void contact with harsh chemicals such as paint remover, bleach, acetone, etc. void contact with hot pans and objects. Repair Kits: Evero repair kits are available. Contact your Bradley representative or distributor for part numbers and pricing. Repair kits are made to order and have a shelf life of 30 days. Evero is a unique cast material. ggregate flow and distribution as well as shades of color can vary from product to product creating natural characteristics. Cleaning and maintenance instructions for stainless steel Material Description: Stainless steel is extremely durable, and maintenance is simple and inexpensive. Proper care, particularly under corrosive conditions, is essential. lways start with the simplest solution and work your way toward the more complicated. Routine cleaning: Daily or as often as needed use a solution of warm water and soap, detergent, or ammonia. pply the cleaning solution per the manufacturer s instructions and always use a soft cloth or sponge to avoid damaging the finish. Stubborn Stains: To remove stains from stainless steel use a stainless steel cleaner and polish such as Ball stainless steel cleaner or a soft abrasive. lways follow the manufacturer s instructions and apply in the same direction as the polish lines. NOTICE! Never use ordinary steel wool or steel brushes on stainless steel. lways use stainless steel wool or stainless steel brushes. Special Situations for Material Fingerprints and Smears: To remove fingerprints or smears use a high quality stainless steel cleaner and polish in accordance with the manufacturer s instructions. Many of these products leave a protective coating that helps prevent future smears and fingerprints. Grease and Oil : To remove grease and oil use a quality commercial detergent or caustic cleaner. pply in accordance to the manufacturer s instructions and in the direction of the polish lines. Precautions: void prolonged contact with chlorides (bleaches, salts), bromides (sanitizing agents), thiocyanates (pesticides, photography chemicals, and some foods), and iodides on stainless steel equipment, especially if acid conditions exist. NOTICE! Do not permit salty solutions to evaporate and dry on stainless steel. The appearance of rust streaks on stainless steel leads to the belief that the stainless steel is rusting. Look for the actual source of the rust in some iron or steel particles which may be touching, but not actually a part of the stainless steel structure. NOTICE! Strongly acidic or caustic cleaners may attack the steel, causing a reddish film to appear. The use of these cleaners should be avoided. Brand Names: Use of brand names is intended only to indicate a type of cleaner. This does not constitute an endorsement, nor does the omission of any brand name cleaner imply its inadequacy. Many products named are regional in distribution, and can be found in local supermarkets, department and hardware stores, or through your cleaning service. It is emphasized that all products should be used in strict accordance with package instructions. 12 6/6/2016 Bradley 215-1829 Rev. B; ECN 16-08-008