M/1700; 5/2 & 5/3 Solenoid and pilot actuated spool valves

Similar documents
97105 Namur direct pneumatically actuated 3/2 and 5/2 spool valves

NuGGeT 200 spool VALVes

VAL-110. Nugget 200 Spool Valves 1/4" and 3/8" Solenoid Pilot Actuated 3/2, 5/2, & 5/3 Inline Valves. Valves. Solenoid Operating Specifications

Monitored Pneumatic Valves On Series Ported Manifold

½ Monitored Pneumatic Valves On Series Ported Manifold

½ Monitored Pneumatic Valve Patented Technology

Air. Pressure. Motion. nnnnnnnn

Condensate drains WA/PWEA

Vacuum generators VADM/VADMI

Vacuum unit ideal for controlling large flow rates Vacuum unit VSQ/VSQP series

How to Order. Combination of supply valve. Light/Surge voltage suppressor. Electrical entry. and release valve Pilot valve. Voltage 5 L Z E C.

Vacuum generators VADM/VADMI

High Pressure Water - Descale Valves - VXXX Series. Quad-S TM Poppet Cartridge Zero Leakage, Media Piloted Raw Water Operation

multi-stage vacuum generators - general information

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-214(C) Series 61 Low Water Cut-Off OPERATION

Vacuum generators. Festo core product range Covers 80% of your automation tasks

INDEX APPLIANCE GAS WATER HEATER CONTROLS 150 ELECTRIC WATER HEATER THERMOSTATS 151 SNAP DISC CONTROLS/LIMITS/SWITCHES 152 GAS DRYER VALVES 153

Condensate Drain Valves

MMEngineering. Suction lifter. Lightning fast suction for lifting and moving. with only on vaccum line. Suction lifters Vacuum-operated

Adsorption dryer SDAT

MODEL A-316 CARBON MONOXIDE (CO) MONITOR AND ALARM FOR COMPRESSED AIR TESTING

Specification/ Data Sheet

Flopurge TS. Operation Manual

Technical Specification VFD

Flostop TS D7E and A8E. Operation Manual

OPERATING AND MAINTENANCE MANUAL FOR PLATE HEAT EXCHANGER INDIRECT FIRED WATER HEATER. Electric Heater Company Base Model "BWXP"

Compressed air treatment. Condensate drains OMEGA AIR

Centro-Matic Automated Lubrication Systems System Controls

Adsorption dryers PDAD

Min Series. Modular Venturi Vacuum Pumps Min Series. Modular Venturi Vacuum Pumps with Solenoid-Operated Vacuum and Blow-Off

PWM expansion valves 2028

Vacuum suction nozzle OVEM-...-1P/1N

Vacuum Module: Ejector System/Vacuum Pump System. For electronic components and precision components up to 100 g

Product Data Sheet Adsorption Dryer DPS (A)

MVG. Modular Vacuum Grippers. US5

Productinformatie BAFA.NL BAFA.NL A.U.K. MÜLLER GMBH & CO. KG

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

Complex Vacuum Generator realizing Stable and High-Speed Response Vacuum Generator VN Series

INSTRUCTION MANUAL MM-615E. Series FS1 High Sensitivity Liquid Flow Switch

21 20 LITER GAS FRYER FFA3200 INSTALLATION AND SERVICING.

Air Filter. Filter for Removing Dust and Drain in Compressed Air. Filter for Drain and Dust (Filtering Accuracy: 5µm)

3500 SERIES CONVECTION STEAM COOKER PARTS AND SERVICE MANUAL

Thermostats type KPU REFRIGERATION AND AIR CONDITIONING. Technical leaflet

SECTION KITCHEN HOOD AND DUCT FIRE SUPPRESSION SYSTEM

Contact Davies Pros On Controls For Proper Application. Solenoid Valves

F261 Series Fluid Flow Switches

PART 0 A/E INSTRUCTIONS 0.01 DESIGN REQUIREMENTS

KITCHEN HOOD AND DUCT FIRE SUPPRESSION SYSTEM

Two-Position Electric Duplex Room Thermostats

FCHM Hydromatic Pump Control Module

SIHI Dry GD S Sizes S450, S650

Water separators MS-LWS, MS series

Automatic Drain Valves. Lasting Values. Series LDV

APPLICATIONS. For the accelerated circulation of hot water in heating circuits with duty point optimisation

Vacuum generators VAD/VAK

IA Inlet Actuator. Instruction Manual. IA Inlet Actuator Models: IA0090 IA0090P. Munters Corporation, March 2017 QM1235r1

Installation Instructions for P/N: Algas-SDI thermostat retrofit kit

Operation Manual. Time controlled condensate drain unit UFZ. 000_H_uf_UFZ_GB_R00_D011002

SECTION AUTOMATIC TRANSFER SWITCHES

THERMOSTATS THERMOSTATS HEATING AND COOLING

TIMER CONTROLLED DRAINS

IS Series Pressure Sensing Switches

Vacuum generation Content

DIESEL ENGINE CONTROL UNIT DCU USER S MANUAL - N-2000 Lillestrøm, Norway Tel: (+47) Fax: (+47)

PRIUX HOME D. High-efficiency double circulating pumps Heating Air conditioning 50 Hz OPERATING RANGE APPLICATIONS BENEFITS

INSTALLING AND USING THE KELCO F50 PUMP CONTROLLER

Product Specification RobExtractSpray 2400/4400

Safety Light Curtains Area Access Control

! WARNING. Before using product, read and understand instructions.

DC200 Digital Dispenser Operating Manual

Effective october 14, 2014

TIMER CONTROLLED DRAINS

UV Flame Supervision System

Dual Pressure Controls

Suction cups VAS/VASB

WILKERSON MODELS DE3, DE4 AND DE5 COMPACT HEATLESS AIR DRYERS

LINETRAXX RCMA420. Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems

SECTION GENERAL-SERVICE COMPRESSED-AIR SYSTEMS

VAV Thermostat Controller Specification and Installation Instructions. Model TRO24T4XYZ1

INSTRUCTION MANUAL MM-601REVI. Series FS4-3 General Purpose Liquid Flow Switch

! WARNING. Before using product, read and understand instructions.

M7100 Pressure Transducer

SECTION HEATING BOILER FEEDWATER EQUIPMENT

Oxygen Sensing Solutions

Caresaver Universal Refrigerant Recovery Unit

QUALITY ASSURANCE/QUALITY CONTROL DOCUMENTATION SERIES OPTEC NGN-2 NEPHELOMETER AUDIT PROCEDURES (IMPROVE PROTOCOL) STANDARD OPERATING PROCEDURE

RA15/6T & TB Conversion Valve

Power Flame Incorporated

Air Filter. Filter for Removing Dust and Drain in Compressed Air. Filter for Drain and Dust (Filtering Accuracy: 5µm)

Installation Instructions for W2H Series Signals

PCS 2000 CONTROLLER USER GUIDE PCS 2000 CONTROLLER. Contents

PC15CP PUMP CONTROLLER

TIMER CONTROLLED DRAINS

Service Data Vickers. Piston Pumps. PVH98/106 Variable Displacement Piston Pump - 11 Design M-2208-S. Revised 05/01/97

MULTI-STAGE, MULTI-FUNCTION AND MODULAR INTERMEDIATE VACUUM MODULES SERIES MI

Hodge Clemco Ltd. MJC Mini Cartridge Filters Owners Manual. TSOM 556 Date of issue 13/07/04. Hodge Clemco Ltd

RQE Series Temperature Controllers

! WARNING. Before using product, read and understand instructions.

cutting systems We Bring Intelligence to the Table.TM Victor Thermal Dynamics introduces

3480/RCH SERIES INSTALLATION INSTRUCTIONS

Transcription:

M/700; / & / > > Port size: G/8... G Sub-base mounted > > Rugged, well proven range of valves > > Simple to service > > Ideal for control of large cylinders > > Ideally suited to heavy duty applications in harsh environments > > G port size - with integral high flow silencer Technical features Medium: Compressed air, filtered, lubricated or non-lubricated Operation: Spool valves, solenoid pilot or air pilot actuated Mounting: On sub-bases Port sizes: G/8, G/, G/ or G Electrical details for solenoid operators Maximum operating pressure: Solenoid pilot actuated valves... 0 bar (9... psi),7... 0 bar (9... psi) or... 0 bar (... psi) depending on solenoid pilot operator Air pilot operated valves:... 0 (9... psi) Refer to technical specification table for details Voltage tolerance ± 0% Rating 00% continuous duty Inlet orifice,0 mm (low power), mm (high power) Electrical connection Industrial Standard, mm (corresponding to choosen coil) Solenoid coil mounting Four positions x 90 Manual override Push and turn to lock (plastic) Protection class IP (with sealed plug) Ambient/Media temperature: Solenoid pilot actuated valves +... +0 C (+... + F) Air pilot actuated valves -0... +80 C (-... +7 F) Air supply must be dry enough to avoid ice formation at temperatures below + C (+ F). Materials: M/7..., M/7... Body and sub-base: Die-cast zinc alloy Spool: Aluminium Centering mechanism: Steel or plastic Seals: NBR M/78 Body and sub-base: Die-cast Aluminium Bush: Brass Spool: and end caps: Light alloy Cushion discs: PU Seals: NBR without notice, the specifications given in this document. (990-70b) 0 Norgren Ltd. / en..0.0

M/700; / & / / Solenoid pilot actuated valves Symbol *) Power see table on page Port size Actuation Pilot supply Flow (l/min) Operating pressure (bar) Power *) Voltage Weight (kg) Drawing No. Model G/8 Solenoid/air spring Internal 0... 0 Low V d.c 0,9 M/7//MAJ G/8 Solenoid/air spring Internal 0... 0 Low 0 V a.c. 0,9 M/7//MA8J G/8 Solenoid/air spring Internal 0... 0 Low 0 V a.c. 0,9 M/7//MA9J G/8 Solenoid/air spring Internal 0... 0 Low Without coil QM/7//MA/ G/8 Solenoid/air spring Internal 0... 0 High V d.c 0,9 M/7//MD8J G/8 Solenoid/air spring Internal 0... 0 High 0 V a.c. 0,9 M/7//MD88J G/8 Solenoid/air spring Internal 0... 0 High 0 V a.c. 0,9 M/7//MD89J G/8 Solenoid/air spring Internal 0... 0 High Wi hout coil QM/7//MD/ G/ Solenoid/air spring Internal 90,7... 0 Low V d.c,07 M/7//MAJ G/ Solenoid/air spring Internal 90,7... 0 Low 0 V a.c.,07 M/7//MA8J G/ Solenoid/air spring Internal 90,7... 0 Low 0 V a.c.,07 M/7//MA9J G/ Solenoid/air spring Internal 90,7... 0 Low Wi hout coil QM/7//MA/ G/ Solenoid/air spring Internal 90,7... 0 High V d.c,07 M/7//MD8J G/ Solenoid/air spring Internal 90,7... 0 High 0 V a.c.,07 M/7//MD88J G/ Solenoid/air spring Internal 90,7... 0 High 0 V a.c.,07 M/7//MD89J G/ Solenoid/air spring Internal 90,7... 0 High Wi hout coil QM/7//MD/ G/ Solenoid/air spring Internal 00,7... 0 Low V d.c., M/7//MAJ G/ Solenoid/air spring Internal 00,7... 0 Low 0 V a.c., M/7//MA8J G/ Solenoid/air spring Internal 00,7... 0 Low 0 V a.c., M/7//MA9J G/ Solenoid/air spring Internal 00,7... 0 Low Wi hout coil QM/7//MA/ G/ Solenoid/air spring Internal 00,7... 0 High V d.c, M/7//MD8J G/ Solenoid/air spring Internal 00,7... 0 High 0 V a.c., M/7//MD88J G/ Solenoid/air spring Internal 00,7... 0 High 0 V a.c., M/7//MD89J G/ Solenoid/air spring Internal 00,7... 0 High Wi hout coil QM/7//MD/ G Solenoid/air and spring Internal 980,7... 0 High V d.c, 7 M/78/7/MD8J G Solenoid/air and spring Internal 980,7... 0 High 0 V a.c., 7 M/78/7/MD88J G Solenoid/air and spring Internal 980,7... 0 High 0 V a.c., 7 M/78/7/MD89J G/8 Solenoid/solenoid Internal 0... 0 Low V d.c. 0,7 M/7//MAJ G/8 Solenoid/solenoid Internal 0... 0 Low 0 V a.c. 0,7 M/7//MA8J G/8 Solenoid/solenoid Internal 0... 0 Low 0 V a.c. 0,7 M/7//MA9J G/8 Solenoid/solenoid Internal 0... 0 Low Without coil QM/7//MA/ G/8 Solenoid/solenoid Internal 0... 0 High V d.c 0,7 M/7//MD8J G/8 Solenoid/solenoid Internal 0... 0 High 0 V a.c. 0,7 M/7//MD88J G/8 Solenoid/solenoid Internal 0... 0 High 0 V a.c. 0,7 M/7//MD89J G/8 Solenoid/solenoid Internal 0... 0 High Wi hout coil QM/7//MD/ G/ Solenoid/solenoid Internal 90... 0 Low V d.c.,8 M/7//MAJ G/ Solenoid/solenoid Internal 90... 0 Low 0 V a.c.,8 M/7//MA8J G/ Solenoid/solenoid Internal 90... 0 Low 0 V a.c.,8 M/7//MA9J G/ Solenoid/solenoid Internal 90... 0 Low Wi hout coil QM/7//MA/ G/ Solenoid/solenoid Internal 90... 0 High V d.c,8 M/7//MD8J G/ Solenoid/solenoid Internal 90... 0 High 0 V a.c.,8 M/7//MD88J G/ Solenoid/solenoid Internal 90... 0 High 0 V a.c.,8 M/7//MD89J G/ Solenoid/solenoid Internal 90... 0 High Wi hout coil QM/7//MD/ G/ Solenoid/solenoid Internal 00... 0 Low V d.c., M/7//MAJ G/ Solenoid/solenoid Internal 00... 0 Low 0 V a.c., M/7//MA8J G/ Solenoid/solenoid Internal 00... 0 Low 0 V a.c., M/7//MA9J G/ Solenoid/solenoid Internal 00... 0 Low Wi hout coil QM/7//MA/ G/ Solenoid/solenoid Internal 00... 0 High V d.c, M/7//MD8J G/ Solenoid/solenoid Internal 00... 0 High 0 V a.c., M/7//MD88J G/ Solenoid/solenoid Internal 00... 0 High 0 V a.c., M/7//MD89J G/ Solenoid/solenoid Internal 00... 0 High Wi hout coil QM/7//MD/ G Solenoid/solenoid Internal 980... 0 High V d.c,0 8 M/78//MD8J G Solenoid/solenoid Internal 980... 0 High 0 V a.c.,0 8 M/78//MD88J G Solenoid/solenoid Internal 980... 0 High 0 V a.c.,0 8 M/78//MD89J en..0.0 without notice, the specifications given in this document. (990-70b) 0 Norgren Ltd. /

M/700; / & / / Solenoid pilot actuated valves Symbol *) Power see table below Port size Actuation Function Pilot supply Flow Operating pressure Power *) Voltage Weight Drawing Model (l/min) (bar) (kg) No. G/ Solenoid/solenoid APB Internal 90,7... 0 Low V d.c, M/7//MAJ G/ Solenoid/solenoid APB Internal 90,7... 0 Low 0 V a.c., M/7//MA8J G/ Solenoid/solenoid APB Internal 90,7... 0 Low 0 V a.c., M/7//MA9J G/ Solenoid/solenoid APB Internal 90,7... 0 Low Wi hout coil QM/7//MA/ G/ Solenoid/solenoid APB Internal 90,7... 0 High V d.c, M/7//MD8J G/ Solenoid/solenoid APB Internal 90,7... 0 High 0 V a.c., M/7//MD88J G/ Solenoid/solenoid APB Internal 90,7... 0 High 0 V a.c., M/7//MD89J G/ Solenoid/solenoid APB Internal 90,7... 0 High Without coil QM/7//MD/ G/ Solenoid/solenoid APB Internal 00,7... 0 Low V d.c, M/7//MAJ G/ Solenoid/solenoid APB Internal 00,7... 0 Low 0 V a.c., M/7//MA8J G/ Solenoid/solenoid APB Internal 00,7... 0 Low 0 V a.c., M/7//MA9J G/ Solenoid/solenoid APB Internal 00,7... 0 Low Without coil QM/7//MA/ G/ Solenoid/solenoid APB Internal 00,7... 0 High V d.c, M/7//MD8J G/ Solenoid/solenoid APB Internal 00,7... 0 High 0 V a.c., M/7//MD88J G/ Solenoid/solenoid APB Internal 00,7... 0 High 0 V a.c., M/7//MD89J G/ Solenoid/solenoid APB Internal 00,7... 0 High Without coil QM/7//MD/ G/ Solenoid/solenoid COE Internal 90... 0 Low V d.c, M/77//MAJ G/ Solenoid/solenoid COE Internal 90... 0 Low 0 V a.c., M/77//MA8J G/ Solenoid/solenoid COE Internal 90... 0 Low 0 V a.c., M/77//MA9J G/ Solenoid/solenoid COE Internal 90... 0 Low Wi hout coil, QM/77//MA G/ Solenoid/solenoid COE Internal 90... 0 High V d.c, M/77//MD8J G/ Solenoid/solenoid COE Internal 90... 0 High 0 V a.c., M/77//MD88J G/ Solenoid/solenoid COE Internal 90... 0 High 0 V a.c., M/77//MD89J G/ Solenoid/solenoid COE Internal 90... 0 High Without coil, QM/77//MD G/ Solenoid/solenoid COE Internal 00,7... 0 Low V d.c, M/77//MAJ G/ Solenoid/solenoid COE Internal 00,7... 0 Low 0 V a.c., M/77//MA8J G/ Solenoid/solenoid COE Internal 00,7... 0 Low 0 V a.c., M/77//MA9J G/ Solenoid/solenoid COE Internal 00,7... 0 Low Without coil QM/77//MA G/ Solenoid/solenoid COE Internal 00,7... 0 High V d.c, M/77//MD8J G/ Solenoid/solenoid COE Internal 00,7... 0 High 0 V a.c., M/77//MD88J G/ Solenoid/solenoid COE Internal 00,7... 0 High 0 V a.c., M/77//MD89J G/ Solenoid/solenoid COE Internal 00,7... 0 High Without coill QM/77//MD Spare coils and alternative voltages mm coil -,0 mm orifice (low power) for connector interface acc. to industrial standard Voltage Power Inrush/Hold Model V d.c W QM/8/J/ V d.c W QM/8/J/ V a.c. /, VA QM/8/J/ 0/0 V 0/0 Hz /, VA QM/8/8J/ 0/0 V 0/0 Hz / VA QM/8/9J/ mm coil -, mm orifice (high power) for connector interface acc. to industrial standard Voltage Power Inrush/Hold Model V d.c 7, W QM/8/8J/ V d.c W QM/8/8J/ V a.c. /8 VA QM/8/8J/ 0/0 V 0/0 Hz /8 VA QM/8/88J/ 0/0 V 0/0 Hz /8 VA QM/8/89J/ Connector plugs - ordered separately Industrial standard mm -pole + PE 0788 / without notice, the specifications given in this document. (990-70b) 0 Norgren Ltd. en..0.0

M/700; / & / / air pilot actuated valves Symbol Port size Actuation Flow (l/min) Operating pressure (bar) Pilot pressure (bar) Weight (kg) Drawing No. G/8 Air/air 0... 0 0,7 + (0, x supply pressure) 0, 9 M/70/ G/ Air/air 90... 0 0,7 + (0,7 x supply pressure) 0,9 M/70/ G/ Air/air 00... 0 0, + (0,7 x supply pressure),0 M/70/ G/8 Air/air 0... 0 + (0, x supply pressure) 0, 0 M/70/ G/ Air/air 90... 0, + (0, x supply pressure) 0,8 M/70/ G/ Air/air 00... 0 + (0, x supply pressure), M/70/ G Air/air... 0 0,7 + (0, x supply pressure),00 M/78/ G/8 Priority air/air 0... 0 *) 0, 0 M/70/ G/ Priority air/air 90... 0 *) 0,99 M/70/ G/ Priority air/air 00... 0 *),0 M/70/ G/ Air/spring 90... 0, + (0,0 x supply pressure) *),00 M/70/0 G/ Air/spring 00... 0, + (0, x supply pressure) *), M/70/0 G Air/air spring 980... 0 + (0, x supply pressure),00 M/78/ Model 8 G/ Air/single impulse 90... 0 0, x supply pressure ( bar) *) 0,90 7 M/787 *) *) Large end 0,8 + (0,0 x supply pressure) bar, at zero; Small end,0 + (0, x supply pressure) bar, at zero If air is permanently applied to the pilot pressure to is 0,7 + (0, x supply pressure) bar when = supply *) Large end 0,8 + (0,08 x supply pressure) bar, at zero; Small end, + (0, x supply pressure) bar, at zero If air is permanently applied to the pilot pressure to is 0,7 + (0,7 x supply pressure) bar when = supply *) Large end 0, + (0,08 x supply pressure) bar, at zero; Small end,0 + (0, x supply pressure) bar, at zero If air is permanently applied to the pilot pressure to is 0, + (0,7 x supply pressure) bar when = supply *) M/70/0 and M/70/0 when used with dual supplies (i.e. main supply to both ports and ) the supply pressure range is... 7 bar. This valve is not intended to be held in the operated condition for more than hours. Where the operation involves delay in excess of hours, please consult our Technical Service. *) Single pulse valve; signal time: 00 ms; pilot signal sequence: 00 ms. Application of a signal on reset port 8 ensures that the valve is in the» flow condition / air pilot actuated valves Symbol Port size Actuation Function Flow (l/min) Operating pressure (bar) Pilot pressure (bar) Weight (kg) Drawing No. G/ Air/air APB 90... 0, + (0, x supply pressure) 0,8 M/70/ G/ Air/air APB 00... 0, + (0, x supply pressure),8 M/70/ G/ Air/air COE 90... 0, + (0, x supply pressure) 0,8 M/7/ G/ Air/air COE 00... 0, + (0, x supply pressure),8 M/7/ Model Seal kit Valve series Port size Seal kit M/70/...; M/7/... G/8 QM/70/00 M/70/...; M/7/...; M/77/... G/ QM/70/00 M/787 G/ QM/787/00 M/70/...; M/7/...; M/77/... G/ QM/70/00 M/78/...; M/78/... G QM/78/00 en..0.0 without notice, the specifications given in this document. (990-70b) 0 Norgren Ltd. /

M/700; / & / Drawings, 7, 7 7 7 0 9 9 9, 8 G/8 9 8, 9, 8 G/8 8, 9 7, 7, 7, 7, 8 8 7, 7 7, 7 7, 7, 9, 9, 0 G/ 9, 8 9, 8 G/ 8 8 8 8 0 Clockwise 90 turnable Mounting threads M through sub-base (M/7, M7) Screwdriver manual override Exhaust port (M) with diffuser Minimum / without notice, the specifications given in this document. (990-70b) 0 Norgren Ltd. en..0.0

M/700; / & / 0, 0,,,,, 0 9 G/ 89,, 9, 8 9 G/ 89, 9, 8, 7,,, 7, 8,,, 7, 8, 97, 8 Clockwise 90 turnable Mounting threads M8 through sub-base (M/7) Screwdriver manual override Exhaust port (M) with diffuser Minimum en..0.0 without notice, the specifications given in this document. (990-70b) 0 Norgren Ltd. /

M/700; / & / 7 0, 77 70 7 9 > 7 8 99 G 8 9 9 9 G 0 99, 9 0 Clockwise 90 turnable Mounting threads M0, 0 mm deep (M/78) Screwdriver manual override Exhaust port (M) with diffuser Minimum / without notice, the specifications given in this document. (990-70b) 0 Norgren Ltd. en..0.07

M/700; / & / 8 0, 77 70 7 9 > 7 8 99 G 0 9 8 9 9 G 0 99, 9 0 Clockwise 90 turnable Mounting threads M0 through sub-base (M/78) Screwdriver manual override Exhaust port (M) with diffuser Minimum en..0.08 without notice, the specifications given in this document. (990-70b) 0 Norgren Ltd. /

M/700; / & / 9, 7 0, 7 G/8, 7 G/8, 7 8, 9 G/8 8, 9 G/8 9, 9, 7, 7, 7, 7, 8 8 7, 7 7, 7 7, 7, G/8 7, 9, G/8 7, 9, G/ G/ 9, 9, 8 8 8 0 0, 0, G/8,, 9, G/8,, 9, 9 G/ 9 G/ 89, 89, 7,,, 7, 8, 97,,, 7, 8, 8 Mounting threads M through sub-base (M/70, M70) M8 through sub-base (M/70) Minimum / without notice, the specifications given in this document. (990-70b) 0 Norgren Ltd. en..0.09

M/700; / & / 0, G/8,, 9 G/ 9, 89, 7,,, 7, 8, 97, 0, 77 70 > 7 8 99 G 9 9 G 0 99, 9 0 Mounting threads M8 through sub-base (M/70) M0 through sub-base (M/78) Minimum en..0.0 without notice, the specifications given in this document. (990-70b) 0 Norgren Ltd. /

M/700; / & / 7 7, 7 7, G/8 9, 7, 8 G/8 8 9, 0 8 G/ Mounting threads M through sub-base (M/787) Minimum Signal reset port Warning These products are intended for use in industrial compressed air systems only. Do not use these products where pressures and temperatures can exceed those listed under»technical features/data«. Before using these products with fluids other than those specified, for non-industrial applications, life-support systems or other applications not within published specifications, consult IMI NORGREN. Through misuse, age, or malfunction, components used in fluid power systems can fail in various modes. The system designer is warned to consider the failure modes of all component parts used in fluid power systems and to provide adequate safeguards to prevent personal injury or damage to equipment in the event of such failure. System designers must provide a warning to end users in the system instructional manual if protection against a failure mode cannot be adequately provided. System designers and end users are cautioned to review specific warnings found in instruction sheets packed and shipped with these products. / without notice, the specifications given in this document. (990-70b) 0 Norgren Ltd. en..0.