Intrinsic Safety Solenoid Valves :-

Similar documents
OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

Installing Foundation Fieldbus H1 in Hazardous Areas. Presented By: Jim Peterson Sr. Applications Engineer MTL/USA

IECEx Certificate of Conformity

Intrinsically Safe Solutions

SET Installation and Operating Instructions. Level switch for one sensor

OilSET-1000 (12 VDC)

OilSET Installation and Operating Instructions. Oil Separator Alarm Device

YTA Series Temperature Transmitters [Style: S3] EN :2006, -11:2007, -26:2007. Supply circuit: Ui=30 V, Ii=165 ma,

SET-2000 Hi Level/Oil

SET-2000 Oil/Sludge. Alarm Device for Oil Separators. Installation and Operating Instructions


Pressure-Resistant and Explosion-Proof Electric Contact Pressure Gauges and Pressure Switches

LDM-519-DIM LHDC MONITOR Digital Line Heat Detector Interface

Intrinsically Safe Flame Detector Installation Guide

SET-2000 Oil/Sludge 12 VDC

Hazardous Area Zirconia Oxygen Systems

Today's world of increasing

DB5 Intrinsically Safe Sounder Type DB-5

Inductive slot sensor

Orbis IS Product Guide MAN 3041

Manual Isolating Barrier D461R1 (Revision 01)

SBEx-4 BISTATE SEPARATOR 1, 2, 3 or 4 channels in rail housing (TS35, 22,5mm width)

DICTATOR Hold-Open Systems for Hazardous Areas

Installation Guide. EXGP Oxygen Analyzer System (ATEX) Interface Electronics Unit

Technical Data. General specifications. Rated operating distance s n 5 mm

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

INSTRUCTION MANUAL. SIL 3 - SIL 2 IIB Group Power Supply for Hazardous Area Equipment DIN-Rail Model PSD1001C PSD1001C

Safety instructions VEGADIF DF65.GX*****H/Z/P/F***** IECEx BVS

Declaration of conformity

IECEx Certificate of Conformity

Fire Alarm System Accessories

L+T GASETECHNIK. Klöpper-Waldmann GmbH & Co. K G. Alarm unit LSG4

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Certificate of Compliance

4) Intrinsic Safety Certification

0 A EIS Intrinsically-Safe Plug-in Intelligent Photoelectronic Smoke Detector INSTALLATION AND MAINTENANCE INSTRUCTIONS

Certificate of Compliance

User s Manual YTA610 and YTA710 NEPSI Certification

ACL TC 200 TEMPERATURE CONTROLLER

FS-100 Series OUTLINE MAIN APPLICATIONS FEATURES LEVEL SWITCH

Air Sensor. SAC Ex FCS Ex. Manual ATEX. AQ M-Tech AB

INSTRUCTION MANUAL (ATEX)

Metal Tube Variable- Area Flow Meter (Series KM, KMS, KMSS)

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

YO3 - YO4 / YL4 - YO5 / YL5

XP95 Intrinsically Safe Product Guide MAN 3054

Level Measurement. Point level measurement Capacitance switches. Pointek CLS100. Overview. Configuration

Matters Needing Attention of Electrical Equipment Installation Engineering in Hazardous Areas. Wang Qiaoli

Universal Tank Alarm Type Installation, Operation & Maintenance

2-Wire Gas Detector Head GD-K88Ai Operating Manual (PT2-193)

Certificate of Compliance

A Guide to Safe Electronic Weighing in Hazardous Locations

Level Measurement. Point level measurement - Capacitance switches. Pointek CLS100. 5/10 Siemens FI Overview.

Technical Information

BA334D Intrinsically safe Externally powered pulse input field mounting rate totaliser Issue 13

Manual Isolating Barrier D461 (Revision 05)

Installation guide for hazardous areas

Page 1 Copyright by the Fieldbus Foundation All rights reserved.

BA338C Intrinsically safe Externally powered pulse input panel mounting rate totaliser issue 13

Fire Alarm System Accessories

Certificate of Compliance

Certificate of Compliance

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor

PumpSaver ISS-105 IS Super Cell Installation Guide

Continuous Gas Analyzers AO2000 Series AO2040-CU Ex Central Unit in Category 2G. Operator s Manual 42/24-13 EN Rev. 3

RADAR LEVEL GAUGE SPECIAL SAFETY INSTRUCTION

UL Topic III. Converting European EEx Certificates. Into. North American Division Certificates

5.1 Safety instructions for system configuration and explosion protection. Zone-specific conditions for system configuration

RT FLOW RATE TOTALISER

ED820-24V MODEL INSTRUCTION MANUAL. fire DETECTOR

EU DECLARATION OF CONFORMITY

Leakage detection sensor

Instruction Manual. Alarm Unit For Low Gas Level # Read manual before use! Observe all safety information! Keep manual for future use!

BA374C Intrinsically safe field mounting indicating temperature transmitter

ABB Instrumentation. Instruction Manual. Model 6553 Series of Intrinsically Safe Gas Analyser Systems for Hydrogen & Purge Gas Purity Measurement

Connection. e. g. Pt100. reference limit. yellow Output I. Composition

Hazardous Areas - EXPLOSIONPROOF SOLENOIDS

Tank Gauging System Special Safety Instruction

Dräger Polytron (approved as type P3S) Transmitter for electrochemical Sensors. Instructions for Use. ST eps

OSA 3. Level alarm for oil separator. Afriso Ema AB. Kilvägen 2 SE Arlöv Sweden T +46-(0) F +46-(0)

Engineering Guideline. pac- Carriers Type Universal

Operating Instructions Edition 02/2007

Alarm Panel Operating Instructions

VERSAFLOW VORTEX Supplementary instructions

EUROPEAN DIRECTIVES Explosive atmospheres ATEX 2014/34/EU

Installing Foundation Fieldbus in Hazardous Areas. Understanding your Options and How to Use Them

User Guide IM/AK1/23 Rev. N. AK102 and AK103 Gas analyzer systems for Hydrogen-cooled alternators

Barrier. ED /07/09 Release to production R.P. A ECO N DATE DESCRIPTION OF CHANGE CHG By ISSUE TITLE TC842B1007 AE PRODUCT SPECIFICATION

Certificate of Compliance

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

Notes: Warrick Series 67 Intrinsically Safe Multi-Function Control Installation and Operation Bulletin

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 870 SERIES INDUSTRIAL CONTROL PANELS

Model FMD. Field Mounted Display Module


CW-5000/5200 Series Industrial Chiller maintenance manual

Environmental Monitoring & Control Units Types MCU 3 & 4 Installation and Hardware

Engineering Guideline. pac-carriers Type SIEMENS ET-200M Fail-safe signal modules

Engineering Guideline. pac-carriers Type for Yokogawa ProSafe-RS

Fieldbus Non-Incendive Concept takes FISCO into Zone 2 and Division 2 hazardous areas. Phil Saward

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS

Transcription:

Intrinsic Safety Solenoid Valves :- Intrinsic safety valves can be used for applications that require similar explosion class/ignition degree to d2g4 or Exd II BT5 type (explosion-proof enclosure construction). Without need for expensive connection tools and complex installation work that are inevitable for explosion-proof enclosure types, the intrinsic safety valves achieve highly reliable explosion-proof performance. Explosion proof barrier SAF3-5, MTL728+ Intrinsic safety barrier is an explosion-proof device with single channel, shunt-diode DC circuit that enables interactive electric signaling without short circuit while controlling energy transmission in order to prevent ignition in explosive atmosphere. 1.Applicable to Zone 0. 2.When serially connected to a transmission circuit, the barrier protects the circuit and components in hazardous area from being affected by a serious accident in the non-hazardous area. 3.Despite in the hazardous location, conventional wiring is available. 4.Intrinsical proof of operational signal is figured out easily and at lower cost. 5.As SAF3-5 safety barrier has protection circuit, it will be not broken if you wired in the wrong polarity. 6.SAF3-5 safety barrier employ crimping terminal wiring method. Model code SAF3-5 MTL728+ Explosion-proof construction Intrinsic safety construction(exiaⅡb) Intrinsic safety construction(i2g4) Rated voltage DC24V±5% - Max. working voltage Max. allowable voltage Safety retention voltage Rating of a fuse - DC25.5V - DC26.6V AC/DC 250V 50mA Ambient temp. -20~60-10~60 Basic circuit figure

Operating condition 1.Place the valve in non-hazardous area. 3. Use with specified solenoid valves. 4. Allowable inductance for external connection: 10mH / Capacitance: 0.5 μf 4. Allowable inductance for external connection: 1mH / Capacitance: 0.05 μf Explosion proof barrier SAF100-5 Intrinsic safety barrier is an explosion-proof device with single channel, Zener-diode DC circuit that enables interactive electric signaling without short circuit while controlling energy transmission in order to prevent ignition in explosive atmosphere. 1.Applicable to Zone 0. 2.A-class ground is not necessary since the input and output are insulated each other. 3.When serially connected to a transmission circuit, the barrier protects the circuit and components in hazardous area from being affected by a serious accident in the non-hazardous area. 4.Despite in the hazardous location, conventional wiring is available. 5.Intrinsical proof of operational signal is figured out easily and at lower cost. 6.SAF100-5 safety barrier employ crimping terminal wiring method. 7.As SAF100-5 safety barrier has protection circuit, it will be not broken if you wired in the wrong polarity. 8.LED indicates the condition of the input and output. Model code Explosion-proof construction Rated voltage Maximum voltage of a Max. allowable voltage Maximum current of a Electric power of a Ambient temp. SAF100-5 Intrinsic safety construction(exiaⅡc) DC24V±10% DC29.4V DC25.95V 93.8mA 0.689W -20~50

Basic circuit figure Does not need A-class ground. 1.Place the valve in non-hazardous area. 2.Perform single grounding using type A ground. 3. Parts and connections cannot be changed. 4. Use with specified solenoid valves. 5. Allowable inductance for external connection: 2mH / Capacitance: 0.05 μf 454 series 5-port solenoid valves (spool valve) Kind of barrier to combin e i2g4 ExiaⅡB T5 MTL728+ SAF3-5 In the case of other explosionproof barriers and combination *1 Structure of the main valve Return Hold 454S202C 454S203C 454S403C 454S404C 454D202C 454D203C 454D403C 454D404C 454S202 M 454S203 M 454S403 M 454S404 M 454D202 M Pilot spool type 454D203 M 454D403 M 454D404 M Port size Rc1/4 Rc3/8 Rc1/2 Rc1/4 Rc3/8 Rc1/2 Effective area of valve 22mm 2 40mm 2 22mm 2 40mm 2 Working pressure Ambient temp. Explosion-proof standard 0.2~0.7MPa -5~50 Intrinsic safety construction 1. Use with specified safety barrier. For i2g4 explosion-proof valves, use them with MTL728+ safety barrier. For Exia II BT5 explosion-proof valves, use them with the safety barrier SAF3-5 or that meets the conditions described below (note *1). 3. Use 1 explosion-proof barrier for each solenoid valve.

414/416 series 5-port solenoid valves (Spool valve / Ceramic slide valve) Kind of barrier to combin e i2g4 ExiaⅡBT 5 MTL728+ SAF3-5 Return 414S302C 414S303C 414S603C 414S604C 416S302C 416S303C 416S603C 416S604C 414S302 414S303 414S603 414S604 416S302 416S303 416S603 In the case of other explosionproof barriers M M M M M M M and combination* 1 Structure of the main valve Pilot spool type Pilot ceramic slide type 416S604 M Port size Rc1/4 Rc3/8 Rc1/2 Rc1/4 Rc3/8 Rc1/2 Effective area of valve 25mm 2 30mm 2 51mm 2 60mm 2 24mm 2 28mm 2 51mm 2 60mm 2 Working pressure 0.2~0.7MPa 0.12~0.7MPa Ambient temp. -5~50-10~60 Explosion-proof standard Intrinsic safety construction 1. Use with specified safety barrier. For i2g4 explosion-proof valves, use them with MTL728+ safety barrier. For Exia II BT5 explosion-proof valves, use them with the safety barrier SAF3-5 or that meets the conditions described below (note *1). 3. Use 1 explosion-proof barrier for each solenoid valve.

414/416 series 5-port solenoid valves (Terminal block ZA) (Spool valve/ceramic slide valve) SAF3-5 Return Kind of In the case of barrier other to ExiaⅡBT 414S302M 414S303M 414S603M 414S604M 416S302M 416S303M 416S603M 416S604M explosionproof barriers combin 5 -YAi -YAi -YAi -YAi -YAi -YAi -YAi -YAi e and combination* 1 Structure of the main valve Pilot spool type Pilot ceramic slide type Port size Rc1/4 Rc3/8 Rc1/2 Rc1/4 Rc3/8 Rc1/2 Effective area of valve 25mm 2 30mm 2 51mm 2 60mm 2 24mm 2 28mm 2 51mm 2 60mm 2 Working pressure 0.2~0.7MPa 0.12~0.7MPa Ambient temp. -5~50-10~60 Explosion-proof standard Intrinsic safety construction 1. Use with specified safety barrier. For Exia II BT5 explosion-proof valves, use them with the safety barrier SAF3-5 or that meets the conditions described below (note *1). 3. Use 1 explosion-proof barrier for each solenoid valve. note *1 In the case of other barriers and combination Konan 454, 414, 416 series intrinsic safety solenoid valves have passed equipment qualification tests for intrinsic safety solenoid valve. The valves can be used in combination with the safety barrier that meets the following conditions. (The valves can be used with insulation barrier that does not need type A ground.) The barrier used in combination with the valves should be the one that has passed equipment qualification tests for a barrier and that meets the following conditions. Safety retention voltage Maximum voltage of a intrinsic safety circuit Maximum current of a intrinsic Less than 29.4V Less than 93.8mA

safety circuit Performance classification / Group Electric power of a intrinsic safety circuit Performance classification Group Allowable inductance (Lo) and capacitance (Co) for an and relationship between inductance (Lo) and capacitance (Cw) for external connections to the Less than 0.689W ia ⅡB or ⅡC Allowable inductance of a intrinsic safety circuit:lo Li+Lw(mH) Allowable capacitance of a intrinsic safety circuit:co Ci+Cw(μF)