DEVICE SPECIFICATION FOR PYROELECTRIC IR-DETECTOR

Similar documents
DEVICE SPECIFICATION FOR PYROELECTRIC IR-DETECTOR

Electrical Configuration: Two single sensing elements and two compensating elements are connected to built-in FET in source follower circuit,

ENGINEERING SAMPLES PYRO-ELECTRIC IR-DETECTOR

Dated 15-Dec-2000; J. Schilz, subject to change

Thermopile Sensor TPS 230 / 3365

Temperature dependent Components within the Pyroelectric Detector

Catalog Pyroelectric & Multispectral Detectors uncooled highly stable high performance highest quality. multi color.

Infrared Sensing Solutions

Pyroelectric Infrared Sensors

Surface Mount 905 nm Pulsed Semiconductor Lasers High Power Laser-Diode Family for Commercial Range Finding

For a Healthier, Cleaner and Safer Tomorrow. Infrared Sensing. For Secure Homes, Healthier Families and Energy Savings

Pyroelectric Infrared Sensor

Infrared Sensing Solutions

Pyroelectric Infrared Sensors

ZMOTION Pyroelectric Sensors

SPECIFICATION of PYROELECTRIC PASSIVE INFRARED SENSOR

Standard SPECIFICATIONS FEATURES APPLICATIONS

SPECIFICATION OF ELECTRET CONDENSER MICROPHONE ( TO : )

mach 5 100kHz Digital Joulemeter: M5-SJ, M5-IJ and M5-PJ Joulemeter Probes

Choosing and Using Pyroelectric Detectors

Technical Data Sheet 5mm Infrared LED, T-1

D5100 Industrial Differential Pressure Transducer

MODEL 834M1 ACCELEROMETER

(PT-A1-AC ) Surface Mount Ambient Visible Light Sensor. Electronics Tech. Direct Electronics Industry Co., Ltd. Version: July 31, 2017

Reverse Package Infrared LED IR25-21C/TR8

Process Technologies for High-Resolution Infrared Detectors based on LiTaO 3

Pyroelectric Infrared Sensor PIR

Installation Instructions for the

Technical Data Sheet. Pb Free. Specification NB104 SSC. Customer. Rev. 03 July 서식번호 : SSC- QP (Rev.0.

-smartgas- A new low cost infrared gas sensor for domestic and automotive applications

D5100 Industrial Differential Pressure Transducer

IR15 Dual Gas Series Datasheet

Technical Data Sheet 3mm Phototransistor T-1

CM97-xxx-7x. Cooled 980nm Pump Laser Module. Product Datasheet. Features. Applications

Data Sheet Sensor: IRA-S210ST01 Lens: IML-0685 / IML Sensor : IRA-S210ST01 Lens : IML-0685/0688. Pyro Electric Infrared Sensor Fresnel Lens

EVERLIGHT ELECTRONICS CO.,LTD.

154BC SPECIFICATIONS FEATURES APPLICATIONS STANDARD RANGES

(HR) Heating Resistors

MS1471 SPECIFICATIONS. PC Board Mountable Pressure Sensor 0-60 mv Output Gage and Absolute Low Cost

SPECIFICATIONS FOR REFOND SURFACE MOUNT LED

Used as indicators of indicating the Degree, Functions, Positions etc, in electronic instruments

The J22 and J23 series are high performance InGaAs detectors operating over the spectral range

82 Constant Voltage SPECIFICATIONS. 316L SS Pressure Sensor 19mm Diameter Package 0-100mV Output Absolute and Gage Temperature Compensated

to get there. together. Infrared Sources Swiss made

Technical Data Sheet 1.5mm Side Face Infrared LED

86 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated

Basic Board Mount Pressure Sensors: NBP Series Uncompensated/Unamplified 60 mbar to 10 bar [1 psi to 150 psi]

IR25 Dual Gas Series Datasheet

Issue C. Installation Instructions for the Basic Amplified Board Mount Pressure Sensors, ABP Series

Installation Instructions for the MicroPressure Board Mount Pressure Sensors MPR Series Compact, High Accuracy, Compensated/Amplified

Honeywell Zephyr Digital Airflow Sensors: HAF Series High Accuracy ±50 SCCM to ±750 SCCM

Highly Near-Infrared-Sensitive, Printed Flexible Thermistors. Austin Shearin ext Brewer Science Inc.

Basics. Conversion principle and parameters of pyroelectric detectors

DP86 Constant Voltage with Fitting

Spectrum Detector, Inc.

FPI Detectors Pyroelectric Detectors with Spectrometer Functionality

Basic Board Mount Pressure Sensors. NBP Series Uncompensated/Unamplified 60 mbar to 10 bar [1 psi to 150 psi] Datasheet

Infrared Sensors Line Guide

85 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated

Free Height 0.8 mm Pitch Board-to-Board Connector (SMT)

Indium Gallium Arsenide Detectors

Technical Data Sheet 5mm Phototransistor T-1

The MiCS-5524 is a compact MOS sensor.

NX7363JB-BC. Data Sheet R08DS0009EJ0200 Rev.2.00 LASER DIODE. Sep 19, 2010 DESCRIPTION FEATURES

Beam Analysis nm and µm - Pyroelectric Array Camera. Pyrocam TM IIIHR & Pyrocam IV Series

Key Features. General Description

A214B/SUG/S400-X6 LAMP. Features. Description. Applications. Revision 1. Expired Period: Forever. LifecyclePhase: Low power consumption

SSC Series Standard Accuracy Plastic Silicon Pressure Sensors ±2 % Total Error Band, Digital Output, SMT and DIP, 1 psi to 150 psi

PRESENTATION OVERVIEW OF THE DIFFERENT MODELS MONITORS

Surface Mount Ambient Light Sensor PTAS-P1F1708CH6. Features. Descriptions. Applications. Device Selection Guide

SPECIFICATIONS. US0603YG LED Chip 0603 Yellow Green SWISSDIS. Swissdis AG Grasweg 7 CH-4911 Schwarzhäusern

RFFM6403. Manufacturing Notes. Table of Contents

PRESENTATION OVERVIEW OF THE DIFFERENT MODELS MONITORS

154BC SPECIFICATIONS. Please refer to the 154N uncompensated and constant voltage datasheets for more information on different features of the 154.

Flame Simulator User Manual. Publication Rev. A

Pyroelectric Infrared Radial Sensor

Quadrature Speed and Direction Sensors

SIEMENS ULTRAMAT 6 IR CARBON MONOXIDE ANALYZER METHOD VALIDATION FOR TESTING CARBON MONOXIDE IN NITROGEN, NF

Basic Board Mount Pressure Sensors: NBP Series Uncompensated/Unamplified 1 Bar to 10 Bar [15 psi to 150 psi]

RPS/DPS High Accuracy Resonant Pressure Sensor. GE Oil & Gas. Features:

Specification MBT801-S

PRODUCT SPECIFICATION

NIDS Dust sensor ED-N-DS-1408

HOA1888 Series. Infrared Assemblies Wide Gap Transmissive Sensor. MICRO SWITCH Sensing and Control

2015 Amphenol Advanced Sensors. Jinton Industrial Park, Wujin, Changzhou, Jiangsu, China. Web:

SPECIFICATION OF ANALOG MEMS MICROPHONE. ( Ultra Mini Top Port ) MODEL NO. : F1-(A)MOE-C110T42-4CP

E PIR Motion Detector. Features. General Description. Applications. Single Sensor Application Circuit

APPLICATION NOTES for LED DISPLAYs

OPERATION MANUAL MODEL 3038 ACCELEROMETER

APPLICATION NOTE. 1. Introduction Application Considerations

Specific Lighting Product Data Sheet M08 CoB Product Series Data Sheet Spec No.: DS Effective Date: 12/15/2016 LITE-ON DCC RELEASE

Measuring THz Radiation choose a Pyroelectric Detector or Golay Cell?

FEATURES ORDERING CODE KED ST D T (1) (2) (3) (4) (5) (6) (7) Transient Voltage Suppressors (ESD Diodes) TRIGON COMPONENTS

Manufacturing Notes for RFPA2016

Following this guideline enables proper treatment of the relays during the critical phase in the relay life.

CMT MANUAL 6. NMC SENSORS

PRODUCT SPECIFICATION

NX7535 Series DESCRIPTION NX7535AN-AA FEATURES NX7535BN-AA

Technical Data Sheet 1.6mm Side Looking Phototransistor

Instruments Designed for POF & Fibre Optic Cable Testing

Transcription:

DEVICE SPECIFICATION FOR PYROELECTRIC IR-DETECTOR CUSTOMER : TYPE PART-NO. : 3800 No. of samples : : PYS 3228 TC G2/G20 Thermally compensated two channel single element detector with lithium-tantalate crystal as sensing element, FET in source follower configuration. This specification is provided by PerkinElmer Optoelectronics GmbH & Co. KG, Wiesbaden. It covers the complete technical data of a pyroelectric IR detector. In case of samples attached to this paper, these have been taken randomly from normal production output. All detectors have met the requirements of PerkinElmer test-specifications and passed outgoing inspection. We kindly ask for approval with the return of a signed copy. Checked: Date: 15.02.07 Customer approval: Date: Detectortype : PYS 3228 TC G2/G20 Partno.: 3800 Page: 1

Electrical Configuration: Two single sensing elements and two compensating elements are connected to built-in FET in source follower circuit, connections "Drain-Source-Ground". It is recommended to use a load resistor of 47 kω. Electrical data: Unless specified differently, all data refer to 25 C: Responsivity: min.: 2,2 kv/w typ.: 3,5 kv/w Responsivity is measured within spectral range 7-14 µm as per fig. 3 at 1Hz. Temperature coefficient of responsivity typ.: -0.1 %/K. Noise: max.: 50 µv pp typ.: 15 µv pp After a 10 minute settling time, noise is monitored for the duration of 1500 sec. at a temperature of 25 C, shut from infrared energy, electrical bandwidth of 0.4 to 10Hz. Operating voltage: Source voltage: Drain-source voltage: V DD = 2-12 V V S = 0.2-1.5 V V DS = min 0.5 V Drain Source 47kΩ Ground Typical Responsivity vs. Frequency Fig.1: Test circuit 100 10 R [kv/w] 1 0,1 0,01 0,1 1 10 f [Hz] Fig.2: Frequency response Detectortype : PYS 3228 TC G2/G20 Partno.: 3800 Page: 2

Test Set up 1: Black Body Radiator 373K = 100 C 2: 1 Hz Chopper 3: Aperture 4: Cover plate 5: Detector 6: Bandpass filter 1 Hz 7: Rectifier 8: Lowpass filter 9: Temperature compensation 10: Display Fig.3: Test Set up Spectral range: The spectral range of the detector is determined by filter built in (window). Substrate: Silicon, multilayer coated Filter (A;B) Application Centre wave length (µm) Half power bandwidth (µm) G20 Reference 4.00 ± 0.08 0.09 ± 0.02 G2 CO 2 4.26 ± 0.05 0.18 ± 0.02 100 90 80 70 Channel A (G20): Reference Channel B (G2): CO2 Transmission [%] 60 50 40 30 20 10 0 3,5 3,7 3,9 4,1 4,3 4,5 4,7 4,9 Wavelength [µm] Fig.4: Filter Transmission Detectortype : PYS 3228 TC G2/G20 Partno.: 3800 Page: 3

Configuration: Housing: TO- 5 metal housing with infrared transparent window Element size: 1.5 x 1.5 mm 2, see also drawing: 2/71321 Connections: Refer to drawing: 2/71321 Field of View Fig.5: Field of View Operating temperature: -40 C to +85 C The electrical parameters may vary from specified values accordance with their temperature dependence. Storage temperature: -40 C to +85 C Avoid storage under high humid environment. Microphonic noise: max: 30 µv rms /g PerkinElmer IR-detectors covered herein have passed qualification test for microphonic noise in x-y-z axis, exciting frequencies from 5Hz to 2kHz. Humidity: The IR-detector shall not increase noise or decrease responsivity when exposed to 95% r.h. at 30 C. Operation below dew point might effect performance. Hermetic seal: This IR-detector is sealed to pass a He-leakage test with maximum leak rate of 10-8 mbar. l. s -1. Quality: PerkinElmer is a QS 9000 certified manufacturer with established SPC and TQM. Detector out-going inspections include the parameters Responsivity, Match, Offset, Noise, Gross leak (Mil Std 883 method 1014C1) on 100%. Individual data are not stored, statistical details can be disclosed on request. Handling: Electrostatic charges may destroy the detector. We recommend to apply precautions necessary for ESD devices to avoid damages. Do not apply physical force to detector leads. Do not expose detector to aggressive detergents such as freon, trichlorethylene, etc. Solder conditions: Hand soldering and standard wave soldering process may be applied. Avoid heat exposure to the top and the window of the detector. Reflow soldering is not recommended. Detectortype : PYS 3228 TC G2/G20 Partno.: 3800 Page: 4

Detectortype : PYS 3228 TC G2/G20 Partno.: 3800 Page: 5