ENERGY SAVING SEIBU GIKEN DST

Similar documents
DEHUMIDIFIERS SEIBU GIKEN DST. Seibu Giken DST AB. Avestagatan 33 SE Spånga, Sweden. Tel Fax

Dehumidifiers from Seibu Giken DST

SEQUENCE OF OPERATIONS

Corrigo E. Second generation which contains all applications and languages

VERSO DOMEKT. Residential ventilation units m³/h. Non residential ventilation units m³/h

DAP III Zone Master User s Guide

ADAC. Advanced Deaerator Control

Flexible & Innovative. Cooling Solutions

Key benefits. Why Condair CP3?

SCC Inc. Master Panel. Specifications. Document No. TS 2010 February 11, Product Description. Sample Specification

L CONNECTION NETWORK Commercial Controls

Reference Guide for Microprocessor Controller

NH Series. Electric Steam Humidifiers. Designed for installation flexibility while maintaining precise humidification control

Master devices. Type X-AIR-ZMAS. Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems

Dehumidifying Dryers DP DP 615 Series

Smart thermostat with Humidification/De-humidification control

Control Systems. Design & Manufacturing. Eco-Friendly. High Performance

Ventilation in balance

Feature Summary. I. System

SIMPLICITY BY DESIGN M52 CONTROLLER

Advanced Facility Air-Management Technology

Siemens Thermostats. RDY2000BN Thermostat

Pressure Steam Humidifiers. Designed to deliver reliable humidity from facility steam boilers. Live Steam

Affordable wireless monitoring without compromise

Pressure Steam Humidifiers LS SERIES. humidity.com

MX43. Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. Cost savings on wiring installation

VERSO-P, VERSO-R Series Air Handling Units with C3 Control System Electrical Installation and Operation Manual

Cultivator & Hybrid Cultivator

Rooftop Ventilator. Models RV and RVE. with Packaged Cooling & Heating

Building system automation. How to use

Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. Cost savings on wiring installation

SAUTER EY-modulo 5. The complete building management solution

INDUSTRIAL DEHUMIDIFIERS. Advanced range of compressor and desiccant dehumidifiers. Dehumidification and drying

Lennox Climatic 50 and BMS Modbus, Trend or BACnet.

NE Series TM. Indoor Pool Dehumidifiers The industry benchmark in quality and customer satisfaction

Daikin Applied UK Technically better... D-AHU Modular R. Air handling units. Compact air handling unit with heat recovery wheel

Energy Recovery with Cooling and Heating Model ERCH

MX43. Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. SIL1 reliability. Gas Detection Control Panel

N M AirControl AHU. Control manual

Swine & Poultry Ventilation - Controllers

Laboratory Enclosed Scroll Air Compressor System with Premium NFPA Controls

NEW. Innovative heating controls. Commercial boiler control systems. Control 8000 & MX25

Dehumidifying Dryers DP DP 615 Series

PRODUCT RANGE POOL AIR HANDLING UNITS. Swimming pool and spa environmental control, heating, cooling and dehumidification

Application Manual LT-6617 Rev. 1 July 2017

Refrigeration Dryers TG TI Series

CAREL heatersteam Electric Element Steam Humidifiers

CONDAIR EL. Electrode boiler steam humidifier Easy maintenance with replaceable cylinders. Humidification and Evaporative Cooling

NA G µair CONNECT 2

DATASHEET CoolTeg Plus CW CoolTeg Plus DX CoolTeg Plus XC

TAP v2.10 Version Date: 6/12/13. Document Microprocessor Controller for Tempered Air Products

Corrigo E - User Manual Ventilation

INC. DESIGN AND INTEGRATION OF ADVANCED SYSTEMS. Multipli Cité REMOTE WATER TREATMENT MANAGEMENT SYSTEM

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

Intelligent control systems Compressor control systems Overriding control systems Central instrumentation and control

Affordable wireless monitoring without compromise

Job Name Control Systems Description Date

EXcon zone control. Control for up to 4 individual zones _ fm. EXHAUSTO A/S Odensevej 76 DK-5550 Langeskov

Humidity Controller Specification and Installation Instructions. Model HRO20

PRODUCT RANGE POOL AIR HANDLING UNITS. Swimming pool and spa environmental control, heating, cooling and dehumidification

Fingertip control, optimum efficiency, total comfort and clear reporting. warmafloor.co.uk

Reference Guide for Microprocessor Controller

Refrigerated Compressed Air Dryers

LV CONTROLLER

COTES ALL-ROUND THE C65 RANGE

0 C to 50 C ( 32 F to 122 F ) 0% to 95% R.H. non-condensing. 30 to 95% R.H. Dry contact across terminal BI1, BI2 & UI3 to Scom

SWIMMING POOL AIR MANAGEMENT DanX

Advantages. Evaporation Chamber. Evaporate water, not money! No tools required. Limits lifting and simplifies handling

Manual for the integration in BMS/GTC

Control System Structure

eq PRIME » ENERGY EFFICIENCY AND FLEXIBILITY STRAIGHT OUT OF THE BOX AIR COMFORT AIR TREATMENT AIR HANDLING UNITS

COOLROW Close control air conditioners for In-Row installation Cooling Capacity: kw

Wilo CO-Helix Booster Systems. Product Presentation July, 2017

Climate control precision in Hi-tech environments Jupiter and Mercury Close Control Units

VERSO Air Handling Units

Effluent Monitoring. Solutions

user s manual VUBMG102

Customers. The core of our innovation. Feeding&Conveying. Drying Dosing Temperature Control Refrigeration Granulation

Energy-efficient heat source provides comfort in large rooms

HVAC Products. SAPHIR AirGo OEM Air Handling Unit Concept

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

Dew point. Special features: Dew point monitoring DS 400. Technical data DS 400. Technical data FA 510

READ AND SAVE THESE INSTRUCTIONS

SAUTER flexotron800 V2 Ventilation V3.3. manual P P

INDUSTRIALS GROUP. Screw Compressors. ESM Fixed Speed & VS Variable Speed

PRODUCT DATA COMBI 300 POLAR BY NILAN. Ventilation with passive & active heat recovery. Active heat recovery. Passive heat recovery.

APC APPLICATION NOTE #119

Process Alarm Solutions

Installation Instructions for the TBLZ-2-66 control box. for controlling two air handling units (Twin Function) GOLD RX

CONDAIR RS. Resistive steam humidifier With advanced scale management. Humidification and Evaporative Cooling

DEHUMIDIFICATION: Ice Arena Application & Product Guide. Design, construct and operate to control indoor humidity in ice rinks

DELOMATIC 400, DM-400 HYDRO

The integral solution for. Air Handling Units. Technology & Evolution

Better Design, Better Control, Better Systems.

Refrigerated Compressed Air Dryers 5-6,000 scfm

Hydronic & HVAC Control Systems

Fan Coil Thermostat Controller Specification and Installation Instructions. Model TFHB24F3XYZ1 with External Humidity Sensor and BACnet Communication

Homepage > Products > Control systems > Demand-based room control with X-AIRCONTROL > Sensors > X-SENS X-SENS

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

CONDENSATION/HUMIDITY PROBLEMS IN BREWERIES

Transcription:

ENERGY SAVING SEIBU GIKEN DST

Energy efficient control for DST dehumidifiers Economy and Environment With new government efficiency targets and ever-increasing energy prices, it is DST s policy to use new technologies wherever possible. This ensures that our products continue to use energy effectively and efficiently. Our programmable logic control (PLC) systems can increase operating efficiency, lower carbon emissions and reduce running costs; factors that may be crucial for environmental certification. PLC s are tailored to ensure highest operating efficiency is achieved for each specific project. PLC s can be used independently, with one of our digital controllers (EH3 T2 & EH4) or interlinked with a building management system (BMS). The primary functions of the PLC are to: - provide a user friendly interface - synchronize the operation of key components - monitor protection devices, trips and alarms - adjust unit capacity to maintain required humidity, temperature or airflow One supplier DST offers a number of systems which controls both humidity and temperature. This means you do not need to coordinate multiple installations everything is supplied optimised, from a single supplier. PLC for industrial dehumidifiers DST s entry level PLC type C2 is fitted as standard to our larger industrial dehumidifiers. A user friendly keypad allows easy access to the menu options and a two-row backlit LCD screen displays important messages to the user. Used in conjunction with one of our humidity controllers (EH3 & EH4) or an external controller (BMS), the dehumidifier drying capacity can be finely tuned to accurately maintain the required set point. PLC C2:1 In/Outputs Digital Inputs: 9 Digital Outputs: 7 Analogue Outputs: 2 PLC C2:1 Features A two row text display Standard PLC for DST dehumidifiers type RZ, RLZ, CZ and Flexisorb. Energy Saving 2 The reactivation heater power is fully regulated between zero and full capacity using either binary (multi-step) or linear (triac or actuator) control. Using our humidity controller EH3 T2 + PLC C2 or an external control signal (BMS + PLC C2), the drying capacity is finely adjusted to accurately maintain the required set point (humidity or dew point). Where precise control is required. Where the process air inlet condition is constantly changing. Where a specific dry air outlet condition is required. On large dehumidifiers to save energy. Energy Saving 3 Used on steam reactivated dehumidifiers only, the reactivation air fan is regulated between 20% and full flow using a motor frequency inverter. The reactivation temperature is maintained at a high level. Using our humidity controller EH3 T2 + PLC C2 or an external control signal (BMS + PLC C2), the drying capacity is finely adjusted to accurately maintain the required set point (humidity or dew point). Where precise control is required. Where the process air inlet condition is constantly changing. Where a specific dry air outlet condition is required. Rotor rotation guard is included in Energy Saving 2 Steam flow automatically adjusts to a change in air flow. Rotor rotation guard is included in Energy Saving 3 Preventing condensation and corrosion using EH3 T2 A temperature sensor attached to the coldest surface is paired with a room humidity sensor. Our EH3 T2 simultaneously monitors surface temperature, relative humidity and dew point of the room air. Our humidity controller EH3 T2 accurately adjusts the drying capacity to maintain the required RH set point. Should the air dew point exceed the monitored surface temperature, EH3 T2 will automatically override the RH set point, increasing its control output to the dehumidifier. EH3 T2 regulates the drying capacity to control both RH and dew point while ensuring least possible energy is consumed. Energy Saving 1 The reactivation heater power output is regulated in two steps. Our humidity controller EH3 T2 or EH4 adjusts the drying capacity between High, Low & Off, as required to maintain the humidity (or dew point) between two programmable set points. Where precise control is not required. Where process air is fully recirculated. Dehumidifier capacity control is achieved by regulating the reactivation heater power Below 50%RH Below the dew-point of the cold water pipe Control the humidity along the red line

Controlling humidity and temperature The PLC C4 and C7 can easily overview and manage the process of controlling both humidity and temperature. The user may also set regulator values and view the process-data. It is possible to manage the start-up process, control, see the functions as well as start and stop the dehumidifier via internet. The PLC s also offers great expansion possibilities since it is easy to add on different functions. Humidity and temperature control Integrating output temperature control in the dehumidification process makes it possible to reduce the total energy consumption thanks to interaction of the humidity and temperature parameters. Cooling and heating coils are built into the dehumidifier. DST is able to offer both DX cooling and coils for chilled water. Heating can be done with either hot water, electricity or steam heating. C4 and C7 For advanced RZ, RLZ, CZ and Flexisorb unit control. Graphic touch display, C4 with 5.7 and C7 with 7. Communication via Modbus TCP/IP, or Remote Access* through Ethernet. C7 also have communicaition with Profibus. Vaisala transmitter connected to C4 Cost-effective process control online. Example of configuration with options PLC C4 with graphic touch display, 5.7. Advanced PLC control with great expansion options. DST provides pre- and post treatment coils complete with temperature control, and all from a single supplier. Contact your nearest DST representative for further information. C4 In/Outputs Digital Inputs: 16 Digital Outputs: 16 Analogue Outputs: 4 Modbus TCP/IP, RTU or Remote Access* via Ethernet. C7 In/Outputs Digital Inputs: 16 Digital Outputs: 16 Analogue Outputs: 4 Modbus TCP/IP, RTU, Remote Access* via Ethernet or Profibus. Rotor Heater Cooler Fan Pilot valve Temp. sensor Moist warm air passes through the dehumidifier and is supplied to the factory as dried and cooled air. PLC C7 with graphic touch display, 7. Advanced PLC control and possible to add Profibus communication. Filter Humidity sensor * Free software from Seibu Giken DST AB. The panel can be mirrored on a computer screen at low cost. Customer oriented solutions The functions of the C4 and C7 can be adapted in many different ways to suit the requirements of a customer. For instance, it is possible to view operating data and alarm logs online, as well as other settings. Since the PLC can be mirrored on a computer screen, allowing to control the dehumidifier via internet, a company can save both personnel resources and travelling time, which is good from an environmental standpoint. The software can be updated through a modem or internet. Modbus, Profibus or Bacnet Communication via TCP/IP or RTU gives the actual values for temperature and humidity, possibility to start/ stop the dehumidifier as well as alarm readouts and operation indicators. Remote access PLC C4 and C7 can be mirrored locally on one or more computers via a network connection. You can communicate with and control your dehumidifier without actually being present! This saves time, money and personnel resources.

Humidity control with electronic humidistat and regulator EH3 T2 and humidistat EH4 Process fan control The dehumidifier can adapt to the customer s process and save energy by controlling the process fan. Constant flow with frequency converter Constant flow regulation irrespective of pressure drop in filters. The flow remains constant even if the filters have been exposed to dirty air, and you can also read the desired and actual flow on your C4 as well. Humidistat and regulator EH3 T2 Humidistat EH4 Room sensor Duct sensor IP 65 EH3 T2, Elektronic humidistat and regulator EH4, electronic humidistat Relative humidity in %RH Absolute humidity in g/kg Dewpoint Cdp Temperature C / K / F Two independent potential PI Regulators for humidity or temperature Two step humidistat Two independent potential free closing contacts Possible to add extra temperature sensor to control condense EH3 T2 In/Outputs Digital Outputs: 2 Analogue Outputs: 2 Option: Modbus RTU Examples of installations EH3 T2 Features: PI regulator for humidity or temperature. Analogue outputs enables possibility to overview status by external computer. Two-step humidistat Sensor with quick respons Two independent potential free closing contacts %RH display with two dioids indicates e.g. too high RH EH4 In/Outputs Digital Outputs: 2 EH4 Features: %RH display with two dioids indicates e.g. too high RH. Option: External display. Display and key set via a 25 meter low voltage cable. Constant pressure with frequency converter This solution allows you to maintain a constant pressure in the dry air duct. Set the desired pressure in the dry air duct to adapt the speed of the process fan to the customer s process. This allows you to open and close valves to various parts of the process and the dehumidifier adapts automatically. Ecovent The Ecovent function is running the unit for 5 minutes/ hour or a fixed time set on the customers PLC, when the humidity is under the set-point. This mean that the unit is running only when necessary and it saves several hours of kwh. The Ecovent is possible to combine with Energysaving 2. The unit is switched on every 5 minutes/ hour to reassure the humidity hasn t gone over the set limit. EH4 mounted in a R-61R dehumidifier Timer control In those cases when it can be difficult to measure the humidity, the dehumidifier can be controlled by a timer. This way, the customer can be reassured that the energy-comsumption is kept low and the area will be dehumidified e.g. during hours with a high level of moisture load. A DR-010B with DST humidistat EH4 controls moisture at a water booster station EH3 T2 mounted in a R-61R unit

Seibu Giken DST AB with representatives in more than 45 countries all over the world Seibu Giken DST AB Avestagatan 33 SE-163 53 Spånga, Sweden Tel +46 (0)8 445 77 20 Fax +46 (0)8 445 77 39 www.dst-sg.com info@dst-sg.com EN 17.10