COOPER POWER SERIES. Types R, W, WV and RV reclosers, KA869R and KA835W series trip coils replacement instructions. Reclosers MN280020EN

Similar documents
COOPER POWER SERIES. Reclosers MN280015EN

COOPER POWER SERIES. Mounting bracket KA19H3 assembly and installation instructions. Reclosers MN280072EN

COOPER POWER SERIES. QD3 Quik-Drive Tap-Changer Position Indicator Drive Gear Kit Number B11. Voltage Regulators MN225056EN

COOPER POWER SERIES. CT Protector Retrofit Kit. Voltage Regulators MN225057EN. Effective March 2017 Supersedes March 2010 (S )

COOPER POWER SERIES. S.T.A.R. TM Fiber optic cable installation instructions. Fault Indicators MN320004EN. Fiber optic fitting (To led display)

Effective May 2017 Supersedes October 1998 (S )

S Voltage Regulators

Instruction Leaflet for the K-Frame, L-Frame, M-Frame, N-Frame and R-Frame 310+ Mining Trip Units

Instruction Manual. Cheese Warmer with Pump

Instruction Manual. Cheddar Easy All-In-One Cheese Corn Shop

BX Series. Installation, Operation, Maintenance Instructions & Spare Parts

Hot Dog Roller Grills

Model 2016, 2025, 2025BN, 2025ST Staging Cabinets Instruction Manual

InstructIon Manual KrEs EQuIPMEnt stands

Instruction Manual. Portion Cup Cheese Warmer

OKB, OKD, & OKH Series

Instruction Manual. Double Candy Apple Cooker

Instruction Manual. 36 in. and 42 in. Popcorn Staging Cabinets

XT Series Thermostats

DH07, DH07A /DH08, DH08A CONVECTED AIR DISH HEATERS

MODEL 8143 SIGNAL SELECTOR INSTALLATION AND OPERATION MANUAL

In data sheets and application notes which still contain NXP or Philips Semiconductors references, use the references to Nexperia, as shown below.

Instruction Manual. Astro Staging Cabinet

Instruction Manual. Spiral Slicer

SPA BLOWER OWNER'S MANUAL XXXX, XXXX, XXXX, XXXX, XXXX, XXXX fax

Instruction Manual. Dogeroo, Super Dogeroo, and Mini Dogeroo

Elevator Control ES Switch

Rev. A AUGUST 2012 RNP SERIES REFRIGERATED COMPRESSED AIR DRYERS OPERATOR MANUAL RNP25 RNP35 RNP50

installation, operation & Maintenance manual Floor-mounted Induction units

Installation & Maintenance Instructions

Model 400 Series Lights Installation Instructions

Disposal Unit (BKSDU) Burger King Shortening. Operation, Service & Parts Manual BURGER KING BKSDU

MaxLite LED MICRO-T PANEL

LV-5 Direct Contact Low Voltage Detector and LV-5/K01 Kit including LV-PT Tester, Holster and Available Accessories

36 & 48 E-Z Cone Fan. Installation & Operator s Instruction Manual (Direct Drive)

MODEL HDM-4 AND HDM-6 PERFECT HOLD DELI CASE INSTALLATION/OPERATION MANUAL

ELECTRONIC FAUCETS INSTRUCTION MANUAL. Toll Free: (800) Haul Road Wayne, NJ krowne.

W Model 1RKU2 w/optional Wall mount. Unit Model Weight (Lbs) Kilowatts Volts- Phase Amps Fan Output Heat Output

installation, operation & Maintenance manual Floor-mounted Induction units acb 30/35

TrueClean ToteCleaner

Operation Maintenance. Mobile Oil Caddy

OPERATOR S MANUAL. For BURLY ATTACHMENTS

User s Manual and Operating Instructions

MODEL NO CRIMPING AND BEADING MACHINE OPERATION, PARTS & MAINTENANCE MANUAL

TURBO Fiberglass Cone Fan and Grill Fan 48'' Belt Drive. Installation & Operator s Instruction Manual

Instruction Leaflet. Read instructions before operating. Retain for future reference.

Service Parts, Kits and Accessories

Armstrong ExpressPack Multi-Tube Steam Dispersion Panel Assembly and Installation Instructions

MN908 No. 282C Replaces 282B LB7013

Use this product according to this instruction manual. Please keep this instruction manual for future reference. MODELS: ST-H15-B & ST-H30

Portion Bag Cheese Warmer

Warranty. Thanks. Thank you for purchasing the Oliso Smart Iron, a safer, smarter way to iron.

1500W STOVE HEATER INSTRUCTION MANUAL. Item No: 050-HA-50090

Air Storm Fans. Air Storm 54 Fiberglass Fan Installation and Operation Manual

20 High velocity Air

SSS BPV- 40 Backpack Vacuum

FE1 Series Ventilation Fans 2007 Soleus Air International. Soleus Air Ultra Quiet Ventilation Fan

SSS Intrepid 16 FMS. Manual

Residential Duct Mount Builder s Box Media Air Cleaner

GULPER 16SV 16 GALLON WET/DRY VACUUM WITH FRONT MOUNT SQUEEGEE

Wrap-Around TOTE Tank / IBC Heaters (TOTE and TOT Series)

Instruction Manual. Table Top Steamer Cart

OUTLET HOT INLET COLD INLET INSTALLATION

DUST FREE CARBON Whole House Air Purifier

LV-S-5. Instruction Manual DIRECT CONTACT STRAY VOLTAGE DETECTOR GENERAL DESCRIPTION HOW IT WORKS

Instruction Manual: IM E. Installation and Operation Manual for Powerware PVL 50, 80, 100, 120, 160, 200 KA

Ultrasonic Reflective Sensor

Instruction Leaflet. Read instructions before operating. Retain for future reference.

Installation and Maintenance "L" and "LS" Series

(HSTAT Series) Instruction Manual

C L E A N I N G / M A I N T E N A N C E WA R R A N T Y I N F O R M AT I O N CLEANING/MAINTENANCE FAN STORAGE 3 YEAR LIMITED WARRANTY INSTRUCTIONS

SSF1610B-CN TRUSTED FOR OVER 100 YEARS. 16 inch (40cm) Oscillating. Stand Fan. Instruction Leaflet PLEASE READ AND SAVE THESE IMPORTANT INSTRUCTIONS

D1C HP Centrifugal Grinder Pump Installation & Service Manual with Parts List. Grinder Pump for Residential and Pressure Sewer Applications

Corrosion Resistant Fluid and Air Handling Systems.

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:

MaxLite LED VAPOR TIGHT LINEAR FIXTURES

VSA/VSB & KSA/KSB Series Air Doors

Instruction Leaflet. Read instructions before operating. Retain for future reference.

OPERATING INSTRUCTIONS AND MAINTENANCE MANUAL

G Series SAVE THESE INSTRUCTIONS. (Model B) Convector Heater for Hazardous Locations GENERAL! INSTALLATION

To get started, please read and follow all instructions for usage and maintenance carefully before operating the VACMASTER BS116 Impulse Bag Sealer.

Cat 5 Pro Vacuum OPERATOR S MANUAL

Note: Please provide valve serial number (stamped on cover of valve) when ordering parts. Tempered Water Outlet. Hot Water Inlet.

55-Gallon Dispenser Package

48 Vanguard Belt Drive Fans Installation and Operators Instruction Manual

OWNERS MANUAL For IN ROOM BREWING SYSTEM MODEL REFILLABLE CAPSULES K901. Includes: Installation Use & Care Servicing Instructions

Roller Dog. Instruction Manual Model #8023, Model #8024 and Model #8025. Cincinnati, OH USA. Model #8024. Model #8025

IMPORTANT SAFETY INFORMATION:

THE BARCLAY HUGGER CEILING FAN INSTALLATION INSTRUCTIONS

HotPoly Tote Tank / IBC Heaters (TTH Series)

FLCH4R Garage and Utility Electric Heater

Electronic Service Manuals

MNEFDD54 & MNBCDD54 GALVANIZED WALL FANS Installation, Operation, and Maintenance Instructions

Installation, Operation and Maintenance Guide AP3900 Series Thermostatic Mixing Valves

Instruction Manual. Bucket Oil Pump

Air Storm Fans. Air Storm 18 Fiberglass Fan Installation and Operation Manual

THE VALOR CEILING FAN INSTALLATION INSTRUCTIONS

Silicone Rubber Heating Tape with Adjustable Thermostat Control (HSTAT Series) Instruction Manual

User s Manual and Operating Instructions

FES - Series Portable Electric Heaters. YES - Series Suspended Electric Heaters CONTENTS

Transcription:

Reclosers MN280020EN Effective October 2015 Supersedes S280-80-14 December 2003 COOPER POWER SERIES Types R, W, WV and RV reclosers, KA869R and KA835W series trip coils replacement instructions

DISCLAIMER OF WARRANTIES AND LIMITATION OF LIABILITY The information, recommendations, descriptions and safety notations in this document are based on Eaton Corporation s ( Eaton ) experience and judgment and may not cover all contingencies. If further information is required, an Eaton sales office should be consulted. Sale of the product shown in this literature is subject to the terms and conditions outlined in appropriate Eaton selling policies or other contractual agreement between Eaton and the purchaser. THERE ARE NO UNDERSTANDINGS, AGREEMENTS, WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE OR MERCHANTABILITY, OTHER THAN THOSE SPECIFICALLY SET OUT IN ANY EXISTING CONTRACT BETWEEN THE PARTIES. ANY SUCH CONTRACT STATES THE ENTIRE OBLIGATION OF EATON. THE CONTENTS OF THIS DOCUMENT SHALL NOT BECOME PART OF OR MODIFY ANY CONTRACT BETWEEN THE PARTIES. In no event will Eaton be responsible to the purchaser or user in contract, in tort (including negligence), strict liability or other-wise for any special, indirect, incidental or consequential damage or loss whatsoever, including but not limited to damage or loss of use of equipment, plant or power system, cost of capital, loss of power, additional expenses in the use of existing power facilities, or claims against the purchaser or user by its customers resulting from the use of the information, recommendations and descriptions contained herein. The information contained in this manual is subject to change without notice. ii TYPES R, W, WV, AND RV TRIP COILS REPLACEMENT INSTRUCTIONS MN280020EN October 2015

Contents SAFETY INFORMATION Safety instructions...iv PRODUCT INFORMATION Introduction...1 Acceptance and initial inspection...1 Handling and storage...1 Quality standards................................................................................1 Description...1 INSTALLATION PROCEDURE Disassembly...2 Replacement...3 TYPES R, W, WV, AND RV TRIP COILS REPLACEMENT INSTRUCTIONS MN280020EN October 2015 iii

! SAFETY FOR LIFE Safety for life! SAFETY FOR LIFE Eaton meets or exceeds all applicable industry standards relating to product safety in its Cooper Power series products. We actively promote safe practices in the use and maintenance of our products through our service literature, instructional training programs, and the continuous efforts of all Eaton employees involved in product design, manufacture, marketing, and service. We strongly urge that you always follow all locally approved safety procedures and safety instructions when working around high voltage lines and equipment, and support our Safety For Life mission. Safety information The instructions in this manual are not intended as a substitute for proper training or adequate experience in the safe operation of the equipment described. Only competent technicians who are familiar with this equipment should install, operate, and service it. A competent technician has these qualifications: Is thoroughly familiar with these instructions. Is trained in industry-accepted high and low-voltage safe operating practices and procedures. Is trained and authorized to energize, de-energize, clear, and ground power distribution equipment. Is trained in the care and use of protective equipment such as arc flash clothing, safety glasses, face shield, hard hat, rubber gloves, clampstick, hotstick, etc. Following is important safety information. For safe installation and operation of this equipment, be sure to read and understand all cautions and warnings. Hazard Statement Definitions This manual may contain four types of hazard statements: DANGER Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury. Indicates a potentially hazardous situation which, if not avoided, may result in equipment damage only. Safety instructions Following are general caution and warning statements that apply to this equipment. Additional statements, related to specific tasks and procedures, are located throughout the manual. DANGER Hazardous voltage. Contact with hazardous voltage will cause death or severe personal injury. Follow all locally approved safety procedures when working around highand low-voltage lines and equipment. G103.3 Before installing, operating, maintaining, or testing this equipment, carefully read and understand the contents of this manual. Improper operation, handling or maintenance can result in death, severe personal injury, and equipment damage. G101.0 This equipment is not intended to protect human life. Follow all locally approved procedures and safety practices when installing or operating this equipment. Failure to comply can result in death, severe personal injury and equipment damage. G102.1 Power distribution and transmission equipment must be properly selected for the intended application. It must be installed and serviced by competent personnel who have been trained and understand proper safety procedures. These instructions are written for such personnel and are not a substitute for adequate training and experience in safety procedures. Failure to properly select, install or maintain power distribution and transmission equipment can result in death, severe personal injury, and equipment damage. G122.2 iv TYPES R, W, WV, AND RV TRIP COILS REPLACEMENT INSTRUCTIONS MN280020EN October 2015

Product information Introduction Eaton s Service Information MN280020EN provides installation instructions for KA869R, Series Trip Coil Kit for its Cooper Power series Type R and RV reclosers, and KA835W, Series Trip Coil Kit for its Cooper Power series Type W and WV reclosers. Before installing, carefully read and understand the contents of this manual. Read this manual first Read and understand the contents of this manual and follow all locally approved procedures and safety practices before installing or operating this equipment. Additional information These instructions cannot cover all details or variations in the equipment, procedures, or process described nor to provide directions for meeting every possible contingency during installation, operation, or maintenance. For additional information, please contact your Eaton representative. Acceptance and initial inspection Each coil kit is in good condition at the factory and when accepted by the carrier for shipment. Upon receipt, inspect the carton for signs of damage. Unpack the kit(s) and inspect thoroughly for damage incurred during shipment. If damage is discovered, file a claim with the carrier immediately. Series-trip solenoids can be equipped with either standard coils or an alternate coil. Standard coils are used to achieve tripping at approximately 200 percent of full-load ratings. Alternate 400S and 560X coils are used to achieve tripping at approximately 140 percent of full-load ratings. The same basic procedure is used to dismantle either solenoid. For additional information on recloser disassembly, reassembly, and testing procedures, refer to the appropriate instruction manual. Service Information S280-30-2 Type R Maintenance Instructions Service Information S280-30-3 Type W (below Serial No. 7333) or S280-30-8 (Serial No. 7334 and above*) Maintenance Instructions Service Information S280-30-9 Types RV (Serial No. 4111 and above*) and Type WV (Serial No. 901 and above*) Maintenance Instructions Table 1. Ordering Information Kit Description Type R Reclosers, Series Trip Coil Kit Serial numbers 9000 and above Type RV Reclosers, Series Trip Coil Kit All Serial Numbers Type W reclosers, Series Trip Coil Kit Serial numbers 2000 and above* Type WV reclosers, Series Trip Coil Kit All Serial Numbers *or beginning with CP57 Cataog Number. KA869R KA803W Handling and storage Be careful during handling and storage of the kit to minimize the possibility of damage. If the valve is to be stored for any length of time prior to installation, provide a clean, dry storage area. Quality standards ISO 9001 Certified Quality Management System Description KA869R series-trip coils can be replaced only in Type R reclosers beginning with serial no. R-9000 and above and all Type RV reclosers. Replacement of KA835W coils is confined to Type W reclosers beginning with serial no. W-2000 or CP57 and all Type WV reclosers. Two coil kits are furnished for replacements to change recloser minimum trip ratings. Two coils in one kit are for substitution in Phase A and Phase B interrupters. The separate one coil kit for Phase C, the interrupter furthest away from the sleethood, has a coil with an opposite wind because of its different position on the interrupter. TYPES R, W, WV, AND RV TRIP COILS REPLACEMENT INSTRUCTIONS MN280020EN October 2015 1

Installation procedure Hazardous voltage. De-energize the switchgear before installing this kit. Follow all locally approved safety practices and procedures when working around high voltage lines and equipment. Failure to comply can result in contact with high voltage, which will cause death or severe personal injury. T232.3 Equipment damage. Refer to the specific switchgear unit maintenance manual for tanking/untanking procedures and related instructions. Failure to follow these instructions could result in equipment damage or personal injury. T238.0 Follow all locally approved safety practices when lifting and mounting the equipment. Use the tapped lifting provisions provided. Lift the load smoothly and do not allow the load to shift. Improper lifting can result in equipment damage. G126.0 Disassembly Refer to the appropriate maintenance manuals referenced on page 1 of this publication for step-by-step procedures to remove the recloser from service, and for specific disassembly and reassembly procedures. The entire installation process should be conducted in a clean environment, such as a repair shop. 1. Bypass, trip, and de-energize the recloser. 2. Carefully transport the unit to a suitable service facility. Equipment damage. Recloser must be open (yellow operating handle, under sleethood, down) before untanking. Tripping the mechanism out of oil will cause excessive mechanical shock to the operating mechanism, which will cause accelerated wear and/or damage to the mechanism. T202.0 Equipment damage. Keep work areas clean to prevent debris from accumulating on or in the hydraulic mechanism during disassembly and reassembly procedures. Failure to comply can result in hydraulic failure and recloser misoperation. T254.0 IMPORTANT When installing this kit, use a clean, lint free cloth to prevent contamination of the hydraulic mechanism during series trip coil replacement. 3. With the recloser in the open position, untank the recloser by loosening the head bolts and washers on the head casting. Carefully lift the head assembly out of the tank using the lifting lug(s). 4. Remove cotter pin and slide out the groove pin that connects the insulated operating links and the solenoid plunger (Figure 1). 5. Remove the terminal that fastens both the bushing lead and the outer coil terminal to the support bracket (Figure 1). Note that for 400S and 560 S coils there is no support bracket. 6. Remove the cap screw that fastens both the terminal and the fiber end of the support bracket to the contact nut of the generator contact tube. 7. Remove the two frame-mounting bolts that secure the solenoid frame to the mounting board and lift the entire solenoid assembly off the mounting board. Dielectric failure, equipment damage. Never use volatile solutions, detergents, or water-soluble cleaners when cleaning the interior of this equipment. These cleaners will contaminate the insulating oil, reducing its dielectric strength. Operation with contaminated insulating oil can result in internal flashovers that will cause equipment damage and possible personal injury. T201.2 8. Lift out the solenoid plunger, guide clips, and guide channels. Slide the upper insulation washer as far as it will go in the direction of the terminal strap. Lift the coil slightly and pull it out of the solenoid frame (Figure 2). Wipe off any carbon deposits on these parts with a clean lint-free cloth. Replace any damaged parts at this time. Figure 1. Series trip solenoid with standard coil. 2 TYPES R, W, WV, AND RV TRIP COILS REPLACEMENT INSTRUCTIONS MN280020EN October 2015

Replacement Check upper coil washer before replacing coils. For coils 280 amperes and below, the upper and lower coil washers are identical. For the 400- and 560-ampere coils a washer with a larger center slot (1-17/32 long instead of 1-7/32 ) is substituted for the upper washer. The bottom remains the same for all coils. 1. Place the lower insulation washer in position (Figure 3). Pass the upper insulation washer over the terminal strap and position it on top of the coil shown in Figure 2-A. Push the coil into the solenoid frame and slide the upper washer into its normal position. Note that in 400X and 560X coils the outer coil is not wrapped around the outside of the solenoid frame, due to the extra one-half turn required inside the frame. Thus, the coil is pushed into the solenoid frame as shown in Figure 2-B. Replace in order the guide channels, guide clips, and solenoid plunger. 2. Place the solenoid assembly back on the mounting board and secure it with two frame-mounting bolts. 3. Connect the operating links to the plunger with groove pin and replace the cotter pin. 4. A separate sleeve is provided with each coil to insulate the outer coil terminal from the frame. Slide sleeve over this outer coil as illustrated. 5. Connect the terminals to the contact tube and the bushing lead to complete reassembly. If 400X or 560X coils are being installed, no support bracket (Figure 1) is required. 6. Retank the recloser and return to service. Figure 2. Solenoid reassembly Standard and 400X/500X coils. Figure 3. Placement of lower insulation washer. TYPES R, W, WV, AND RV TRIP COILS REPLACEMENT INSTRUCTIONS MN280020EN October 2015 3

! SAFETY FOR LIFE Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com Eaton s Cooper Power Systems Division 2300 Badger Drive Waukesha, WI 53188 United States Eaton.com/cooperpowerseries 2015 Eaton All Rights Reserved Printed in USA Publication No. MN280020EN KA2048-076 Rev: 02 Eaton is a registered trademark. All trademarks are property of their respective owners. For Eaton's Cooper Power series product information call 1-877-277-4636 or visit: www.eaton.com/cooperpowerseries.