SLATE. Base Module INSTALLATION INSTRUCTIONS R8001A1001

Similar documents
SLATE. Sub-Base Module INSTALLATION INSTRUCTIONS R8001S9001

SLATE. Burner Control Module INSTALLATION INSTRUCTIONS R8001B2001

SLATE. Rectification Ampli-Check Flame Amplifier INSTALLATION INSTRUCTIONS R8001V1031

SLATE. UV Ampli-Check Flame Amplifier INSTALLATION INSTRUCTIONS R8001S1071

INSTALLATION INSTRUCTIONS

YP7999A1000 ControLinks Fuel Air Ratio Control Panel

7800 SERIES 22-Terminal Universal Subbase

Honeywell SLATE ICM Platform

7800 SERIES RM7888A Relay Module

RM7838A 7800 SERIES Relay Modules

7800 SERIES EC7823/RM7823 Relay Module

7800 SERIES RM7888A Relay Module

RM7895A,B,C,D/EC7895A,C; RM7896A,B,C,D 7800 SERIES Relay Modules

7800 SERIES S7830 Expanded Annunciator

7800 SERIES EC7885A/RM7885A Relay Module

7800 SERIES EC7890A,B; RM7890A,B,C Relay Module

7800 SERIES RM7840E,G,L,M; EC7840L Relay Module

7800 SERIES S7800A2142 Keyboard Display Module

RM7897A,C 7800 SERIES Relay Modules

7800 SERIES EC7895A,C; RM7895A,B,C,D and RM7896A,B,C,D Relay Modules

configurable safety and programmable logic SLATE Integrated Combustion Equipment Management The revolutionary integration of

RM7895A,B,C,D/EC7895A,C; RM7896A,C,D 7800 SERIES

R7120M 7800 SERIES Relay Modules

7800 SERIES: EC7895A,C; RM7895A,B,C,D; RM7896A,B,C,D RM7897A,C and RM7898A Relay Modules

R7824, R7847, R7848, R7849, R7851, R7852, R7861, R7886 Amplifiers for 7800 SERIES and R7140 Relay Modules

7800 SERIES RM7840E,G,L,M Relay Module

RM7890D; RM7895E,F 7800 SERIES Relay Modules

Q7800H Integrated Burner Control Subpanel

7800 SERIES S7800A1167 Keyboard Display Module

CR Series Command Relays

Cleaver-Brooks CB780/CB784 Operation and Maintenance Manual

R7824, R7847, R7848, R7849, R7851, R7852, R7861, R7886 Amplifiers for 7800 SERIES and R7140 Relay Modules

RM7890A1056, RM7890B SERIES

RM7890; RM Vac 7800 SERIES Relay Modules

YP7899C SERIES Burner Management Panel

MBCE-110/230FR Flame Sensor Module

Model 17A00 Expansion Enclosure

VA301C CONTROLLER WITH BACnet OPTION

7800 Series RM7888A Relay Module

Commercial/Industrial Combustion Control Level Three Announcement

Solid Core and Split Core 0-5, 0-10 Vdc Output Current Sensors CTS-05,10; CTP-05,-10

Suggested Specification: Benchmark 1.5 Low NOx Gas-Fired Hydronic Boiler(s)

Carbon Monoxide Transmitter

Sola Hydronic Control. An Eco-Friendly Solution.

MBCE-110/230FR Flame Sensor Module

R7910A SOLA (Hydronic Control) and R7911 SOLA (Steam Control) Systems

Refer to Bulletin E-1101 for detailed information on the FLAME-MONITOR System.

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

Solid Core and Split Core 4-20 ma Output Current Sensors CTS-20; CTP-20

7800 SERIES EC7810A, EC7820A Relay Module

R7910A SOLA (Hydronic Control) and R7911 SOLA (Steam Control) Systems

APPLICATION SPECIFICATIONS INSTALLATION INSTRUCTIONS. The following assumptions apply when using the RM7840G,L, RM7800L, EC7840L:

MBCE-110/230UV Flame Sensor Module

SCC Inc. TS Series. Technical Instructions. Document No. TS 1000 June 25, TS Touchscreen Kits. Description. Touchscreen

T M. User Manual. MarinaGuard. Ground Fault Monitoring Panel For Marina Shore Power

A New Standard of Excellence

LORAIN CIP 4890/48120 DC Power System

Power Supply Display Module PSDM. Installation and Operation Manual

Networked Access Control Panel. Installation Guide

SP-1000X. Panic Device Power Controller Installation Guide. Rev

ACS-30 MULTIPOINT COMMERCIAL HEAT-TRACING SYSTEM PRODUCT OVERVIEW. ACS-30 System

R7824, R7847, R7848, R7849, R7851, R7852, R7861, R7886 Amplifiers for 7800 SERIES and R7140 Relay Modules

isopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

IS Series Pressure Sensing Switches

RPSMLR2 RPSMLR2BB. Panic Device Power Controller Installation Guide LISTED. Rev

ELECTRONIC FLAME SUPERVISION MULTI-BURNER

SPECIFICATION: AlarmLine TM INTELLIGENT LINEAR HEAT DETECTION

RMS/RPX Reader. User Manual

Operating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm

INSTALLATION INSTRUCTIONS

FIREYE NXF4000 ADVANCED BURNER MANAGEMENT SYSTEM with INTERNAL FLAME SAFEGUARD

KT-100 Door Controller

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 PRODUCT OVERVIEW

EC-BOS-602/616 AX Security

ISOMETER IRDH375. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems)

21-light Remote Annunciator. Owner s Manual

C SINGLE-POINT HEAT-TRACING CONTROL SYSTEM PRODUCT OVERVIEW

C554A Cadmium Sulfide Flame Detector

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3

WARRANT Y AND LIMITS OF LIABILIT Y Vulcain Inc. warrants to the original purchaser that its product, and the component parts thereof, will be free fro

Dual Input ph/orp Analyzer

Across-the-Line SERIES MP300 Combined Manual and Automatic

4100U City and Relay Cards Installation Instructions

LC3000 Level Controller Installation and Maintenance Instructions

THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16

Booster Power Supply Manual

TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS

T7079A,B Solid State Remote Temperature Controllers

Rev Pulse Modulating Anti- Sweat Control (PMAC II) Installation and Operation Manual

Two-Channel Gas Controller

LORAIN CSP DC Power System

NGC-40 Advanced Heat-Tracing Control System

SmartVFD HVAC and BYPASS

Halton SAFE / 7.14 user guide and installation instructions

LG ELECTRONICS Air Conditioning Technologies LG Guide Specifications Controls

C7232A,B Sensor and Controller CARBON DIOXIDE SENSOR

7800 SERIES RM7824A Relay Module

Installation Guide for models:

TTSIM-1A. TraceTek Sensor Interface Module with Relay. Installation/Operation Instructions. Installation Items (not supplied) Tools Required.

Transcription:

SLATE Base Module R8001A1001 INSTALLATION INSTRUCTIONS

Scan for more information

Application SLATE brings configurable safety and programmable logic together into one single platform. The platform can easily be customized for almost any requirement or application offering virtually limitless development opportunities with far less complexity. The R8001A1001 base module provides communications and power supply for the SLATE system, configurable safety for Burner Control, Flame Amps, Fuel Air Ratio, and Limit modules, and programmable logic for Digital and Analog I/O, and Annunciation. SLATE is a combustion system with configurable safety and programmable logic. The system is modular in format and DIN rail mountable. Modules include: Base Burner Control Module Flame Amp Modules Fuel Air Ratio Control Module Limit Module Analog I/O Module Digital I/O Module Annunciator Module SLATE BASE MODULE 3 R8001A1001

Features Within the SLATE system, the base module provides: Power to all modules with multiple voltage options External communication protocols Modbus/TCP, BACnet MSTP or IP, and web services Overall health of the system The ability to do remote troubleshooting Network identification of the system as a single device Web-based pages (both Honeywell provided and designer customized) for Web browser access to the system Module identification for the system Event log storage for user lockouts, fault history, and user requested events Trend logging for user specified data Specifications Electrical Ratings: Input Voltage and Frequency: 24 VDC (± 15%), 24 VAC (± 15%), 50/60 Hz, 85-264 VAC, 50/60 Hz Output Voltage: 18 VDC (± 1 VDC) Power Dissipation: 38W max @ 24V (approx. 12 modules), 45W max @ 85-264V (approx. 14 modules) Fusing Total Connected Modules: 5A, slow type, non-replaceable Terminal Ratings: See Table 1. Terminal Description Rating E100-1 L1 - line voltage hot --- E100-2 L2 - line voltage common --- E100-3 PE - Earth Ground --- 4 32-00005 01

Terminal Description Rating E200-1 Alarm (dry contacts) 120 / 240 VAC, 1A pilot duty E200-2 Alarm (dry contacts) 120 / 240 VAC, 1A pilot duty E200-3 Unused --- E200-4 A (BACnet MS/TP) --- E200-5 B (BACnet MS/TP) --- E200-6 GND (BACnet MS/TP) --- E200-7 VAUX + 3.3-24 VDC output, 250mA max E200-8 VAUX - a 3.3-24 VDC output, 250mA max a Do not connect to earth ground. Table 1. Terminal Ratings. Environmental Ratings Ambient Temperature: Operating: -20 F to +150 F (-29 C to +66 C). LCD Operating: 32 F to +150 F (0 C to +66 C). Shipping: -40 F to +150 F (-40 C to +66 C) Humidity: 95% continuous, noncondensing. Vibration: 0.5G environment Dimensions: See Fig. 1 Weight: 2 lb 1 oz (0.94 Kg) Approvals: Underwriters Laboratories Inc. Listed, File: MP268. IRI acceptable. Federal Communications Commission: Part 15, Class A Emissions. Must be mounted inside a grounded metal enclosure. Mounting: DIN Rail (See Fig. 4) SLATE BASE MODULE 5 R8001A1001

7-3/32 (180) 6-3/32 (155) 5-19/64 (135) M35389 Fig. 1. Dimensions in in. (mm). 6 32-00005 01

Principal Technical Features The R8001A1001 base module provides communications and power supply for the SLATE system, configurable safety for Burner Control, Flame Amps, Fuel Air Ratio, and Limit modules, and programmable logic for Digital and Analog I/O, and Annunciation. Communications The base module provides communications via Modbus IP RS485, BACNet IP/MSTP (RS-485), and Web Services. User Interface The menu-driven user interface provides system status and alerts via a dot matrix display on the front of the module. It is controlled by a 7-button keypad. LED Array There are three LEDs on the front of the base module that provide quick identification of system status and problems. This status is broadcast to other modules on the platform bus in case they are affected by the inoperable module(s). LED Color Description Power No light System does not have power Green System has power CPU Fault Red Green Red No light Table 2. LED Descriptions. No wire sheet or problem with the wire sheet Running Fault Running SLATE BASE MODULE 7 R8001A1001

LCD Screen The base module LCD screen will show information about various modules and other parts of the combustion system. Use the arrow keys to navigate the items on the LCD screen, then press OK to select one. In Fig. 2, Burner6 is in Lockout. For additional information, navigate to that menu item and press OK. Slate Application: Running m6 Burner6: Lockout > 1FM-VU-Achk Running m1 Base: Running m2 Burner: Hold > scroll 8:07 am OK:select > > Power CPU Fault Light Sensor Main Power Status Menu OK Fig. 2. LCD display showing a fault (Burner6 is in Lockout). M35422 Additional information, as shown in Fig. 3, is displayed. Use this information to troubleshoot the combustion system. 8 32-00005 01

< m6 Burner6: FAULT Fault code: 35 Flame is OFF Date: 4 Nov 2014 Time: 3:30 PM scroll <back > > Power CPU Fault Light Sensor Main Power Status Menu OK Fig. 3. Additional lockout information. M35423 Light Sensor SLATE contains a light sensor that is used when the system is exposed to light. This is a power saving feature. Installation WARNING Fire or Explosion Hazard Can cause severe injury, death, or property damage. Verification of safety requirements must be performed each time a control is installed on a burner to prevent possible hazardous burner operation. SLATE BASE MODULE 9 R8001A1001

When Installing This Product 1. Read these instructions carefully. Failure to follow them could damage the product or cause a hazardous condition. 2. Check the ratings given in the instructions and on the product to make sure the product is suitable for your application. 3. After installation is complete, check out the product operation as provided in these instructions. Wiring WARNING Electrical Shock Hazard. Can cause severe injury, death, or equipment damage. 1. Disconnect the power supply before beginning installation to prevent electrical shock and equipment damage. More than one power supply disconnect can be involved. Fig. 4. Installing the Base Module on DIN Rail. M35390 10 32-00005 01

2. Wiring must comply with all applicable codes, ordinances and regulations. See Table 1, Table 3, and Recommended Grounding Practices on page 13 for connections and terminals. For DIP switch settings, see DIP Switches on page 15. Note: MS/TP must be wired in a straight line without spurs no star wiring. Main Power Status Menu OK DIP SWITCHES USB ETHERNET REMOVEABLE SD CARD INTERNAL SD CARD INTERNAL CLOCK BATTERY INPUT POWER BACnet AND PROGRAMMABLE POWER SUPPLY L1 L2(N) ALARM A B G M35391 Fig. 5. Base Module inputs and terminals. SLATE BASE MODULE 11 R8001A1001

3. Wiring must comply with NEC Class 1 (Line Voltage) wiring. 4. The R8001A1001 should not interfere with the proper safety operation of the controls, limits, and interlocks it is monitoring. After installation, check each control, limit, and interlock to ensure that it is operating properly. DO NOT PLACE JUMPER WIRES ACROSS THE INSTALLATION CONTROLS, LIMITS, AND INTERLOCKS. Application Line voltage terminals Communication lines a Other terminals Recommended Wire Size 14, 16, or 18 AWG copper conductor, 600 volt insulation, moistureresistant wire. 22 AWG two-wire twisted pair with ground, or five-wire. 18 AWG wire insulated for voltages and temperatures for given application. Recommended Part Numbers TTW60C, THW75C, THHN90C Belden 8723 shielded cable or equivalent. TTW60C, THW75C, THHN90C a BACnet MS/TP connections must be wired in daisy chain configuration, 1(a)-1(a), 2(b)-2(b), 3(c)-3(c). The order of interconnection of all the devices is not important. Be aware that the termination DIP switch (number 3) must be used if the SLATE system is at the end of connections over 100 feet. Table 3. Recommended Wire Sizes and Part Numbers. 12 32-00005 01

Recommended Grounding Practices Use an Earth ground or a signal ground as described below. Earth ground (Base, Rectification Flame Amp Module, other modules optional) 1. Use to provide a connection between the base and the control panel of the equipment. Earth ground must be capable of conducting enough current to blow the breaker in the event of an internal short circuit. 2. Use wide straps or brackets to provide minimum length, maximum surface area ground conductors. If a leadwire is required, use 14 AWG copper wire. 3. Make sure that mechanically tightened joints along the ground path are free of nonconductive coatings and protected against corrosion on mating surfaces. Signal ground Note the 18V system ground is not electrically connected to earth ground. Follow local codes and appliance recommendations to determine if this should be connected to earth ground. Recommended wire routing of leadwires Do not run high voltage ignition transformer wires in the same conduit with the flame detector or data lines. Do not route flame detector or data lines in conduit with line voltage circuits. Enclose flame detector leadwires without armor cable in metal cable or conduit. Follow directions in flame detector instructions. Be sure loads do not exceed the terminal ratings. Refer to the labels or terminal ratings in Table 1. The SLATE system must be mounted in an electrical enclosure. When mounting in an electrical enclosure, provide adequate clearance for servicing, installation and removal of SLATE modules. SLATE BASE MODULE 13 R8001A1001

IMPORTANT 1. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with these instructions, may cause interference for radio communications. It has been tested and found to comply with the limits of a Class A computing device of part 15 of FCC rules, which are designed to provide reasonable protection against such interference when operated in a commercial environment. Operation of this equipment in a residential area may cause interference; in which case, the user, at their own expense, may be required to take whatever measures are required to correct this interference. 2. This digital apparatus does not exceed the Class A limits for radio noise, set out in the Radio Interference Regulations of the Canadian Department of Communications. 3. For straight gas burner applications, the oil limit and interlock inputs DO NOT need to be jumpered. 4. For straight oil burner applications, the gas limit and interlock inputs DO NOT need to be jumpered. 5. For combination gas-oil burner applications, a double pole, double throw (dpdt) fuel select switch is required. 6. Cable shield must be terminated to ground at both ends. If shielded cable is NOT used, use three-wire twisted cable. WARNING Electrical Shock Hazard. Can cause severe injury, death or equipment damage. Disconnect the power supply from the main disconnect before beginning installation to prevent electrical shock and equipment damage. More than one disconnect can be required. 14 32-00005 01

DIP Switches The SLATE Base Module has three DIP switches. DIP switches 1 and 2 should be On only if no other MS/TP device providing bias resistors is connected. DIP switch 3 should be On only if SLATE is the last device in the communication chain. SLATE BASE MODULE 15 R8001A1001

32-00005-01 For more information and detailed instructions on the SLATE display please refer to the SLATE User Guide document located on our website at http://combustion.honeywell.com/slate Automation and Control Solutions Honeywell International Inc. U.S. Registered Trademark. 1985 Douglas Drive North 2014 Honeywell International Inc. Golden Valley, MN 55422 32-00005 01 M.S. 12-14 customer.honeywell.com Printed in U.S.A.