Connecting cable. Installation instructions (2018/04) US

Similar documents
Residential Gas Condensing Boiler Greenstar ZBR16/21/28/35/42-3A... ZWB28/35/42-3A...

User manual. Logano GC 124 II. Gas boiler

Residential Gas Condensing Boiler Greenstar combi 100 p / 151 p ZWB28-3A... ZWB42-3A...

USER'S INFORMATION MANUAL

USER'S INFORMATION MANUAL

USER'S INFORMATION MANUAL

USER'S INFORMATION MANUAL

USER'S INFORMATION MANUAL

Operating instructions

Conversion Instructions Logano G234X. Gas boiler. Please read carefully before installing and servicing. Gas boiler

Intelligent cascading kit

GB162 Concentric Horizontal Vent Kit

Outdoor kit. Models: RTG 199HE / RTG 199ME. Installation Instructions

Wall Hung Boiler Room Thermostat OR30 OT Thermostat

Operating Instructions

USER'S INFORMATION MANUAL

O. Gas boiler. Gaz 6000 W WBN H-E-N/L-S2400. Operating instructions for the end customer (2017/09) en

USER'S INFORMATION MANUAL

Bosch 80% AFUE Gas Furnace BGS80 Model

Cast Iron Commercial Hot Water Or Steam Boiler

O CRC100. Comfort Room Controller (2015/01) en

USER'S INFORMATION MANUAL

O CRC200. Comfort Room Controller. Installation instructions for contractors (2015/02)

USER'S INFORMATION MANUAL

Side by side. Cascade Venting System for RTG 199HE. Extension Set for units 3 or Installation instructions

Back to back. Cascade Venting System for RTG 199HE. Basic Set for units 1 and Installation instructions

USER'S INFORMATION MANUAL

Operating instructions

/2010 US/CA

Installation instructions. Pump Group. For wall hung gas-fired condensing boiler GB162-50/65/80/ TD UK/IE (2014/09)

Installation & Operation Manual Models:

For the heating engineer. Installation manual. Interface 0-10V VR34

Tankless Water Heater

Bosch Split-Type Ductless Air Conditioner / Heat Pump

Elite. User s Information Manual. Elite and Elite VWH* All Models

TO DO IF YOU SMELL GAS

T UNI 7000 F. Operating instructions For the user (2006/05) AU/GB

Installation & Operation Manual Models: TSU

User s Information Manual Models: ER152, ER202, ER252, ER302, and ER402

Residential Gas Hybrid Water Heater

User Manual FLOWMAX-90. for model. Condensing water heater 85,000 BTU. Installation, operating, commissioning and maintenance instructions.

Installation and maintenance instructions

User s Information Manual

CONVERSION TO PROPANE MANUAL M-Series Condensing Boiler. Wall-Mounted, Gas-Fired Boiler

Operating instructions

INSTALLATION INSTRUCTIONS FOR FLUE KIT

Operating instructions

MULTI-TEMPERATURE LOOP CONTROL BOARD INSTRUCTIONS

User s Information Manual

User s Information Manual

If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

User s Information Manual Models: 45, ,000 Btu/hr

Installation and service instructions

HMC300. Control unit. Operating Instructions. EMS plus (2014/10) O

Packaged Gas/Electric Units. Owner s Guide to Operating and Maintaining Your Gas/Electric Unit

Installation & Operation Manual NCB-E Condensing Combi-Boilers

MULTI-TEMPERATURE LOOP CONTROL BOARD INSTRUCTIONS

MC Series Gas-Fired Heating Appliance

CondenseSure Siphon INSTALLATION INSTRUCTIONS UK/IE GREENSTAR EXTERNAL 500ML SIPHON

Owner s Guide. 24-inch Gas Wall Oven with Time-Of-Day Clock and Timer Canada w A/01/08

Greenstar Xtra. Installation instructions. Passive flue gas heat recovery device. For use with Greenstar CDi Compact, Si Compact and i combi boilers

User s Information Manual

P.O. Box , Dallas, TX USER'S INFORMATION MANUAL Single-Stage Warm Air Gas Furnaces

Ignition Burner Maintenance

Installation and operation manual

User s Information Manual

User s Information Manual

Operating instructions

User Manual Models: 502, 752, 1002, 1302, 1501, 1701, and 2001 Up To 5:1 Turndown

User's Infomation Manual

Gas Fired Residential Combi Boiler Floor and Wall Mount Models

Universal Fire Tube Boiler Wall Mount Models

FM458/CMC 930. Strategy module. Service instructions. For contractors. Read carefully prior to commissioning or service.

Operating instructions

User s Information Manual

Model BW9 Gas-Fired Direct Vent Condensing Water Boiler

INSTALLATION INSTRUCTIONS INSTRUCTIONS D INSTALLATION INSTRUCCIONES DE INSTALACIÓN

R. Boiler Energy Management System FW 200. Operating Instructions for the User (2010/05)

If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

R. Room temperature controller with solar control FR 120. Operating instructions for the user (2012/02)

USER S INFORMATION MANUAL (2,4)SG13B

Indirect Fired Water Heaters

MANUAL WARNING FIRE OR EXPLOSION HAZARD. SL280UHNV SERIES WHAT TO DO IF YOU SMELL GAS:

36" GLASS SEALED-BURNER GAS COOKTOP

Room-temperature (economy/night) unit TR 212 E

SM Field Installed Electric Heat Kit

and/ or User s Information Manual

GAS COOKTOP MODELS: CTG365D, CTG305D, CTG304D TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING

Multi Box HP 10. Accessories, split air to water heat pump PRINT APPROVAL 1 NOVEMBER Installation instructions (2012/11)

Installation instructions. Advanced Weather Compensation Controller. Sense II O UK/IE (2015/10)

USER S INFORMATION MANUAL

MPE12FG MPE12FS MC

E-Z Zone Pack 3+1 And 5+1 Boiler Manifold System

USER'S INFORMATION MANUAL

RT 10 RT 10 INSTALLATION, USER INSTRUCTIONS & CUSTOMER CARE GUIDE. Order no

Installation Instructions Dual Fuel Ranges

Owner's Guide to Operating and Maintaining Your Gas/Electric Unit

GAS COOKTOP INSTALLATION INSTRUCTIONS BEFORE YOU BEGIN. IMPORTANT Save these instructions for local electrical inspector s use.

USER'S MANUAL PGE Single Package Rooftop

Fig. 1 - Unit PGD4, PGS4, WPG4

Transcription:

Connecting cable 7736504943 Installation instructions 6 720 882 320 (2018/04) US

2 Contents Contents 1 Explanation of symbols and safety instructions........................... 3 1.1 Guideline to symbols............. 3 1.2 Safety instructions............... 3 2 Information about the accessory......... 4 2.1 Cable specifications.............. 4 2.2 Proper use...................... 4 3 Scope of delivery...................... 4 4 Installation instructions................ 5 4.1 Safety instructions............... 5 4.2 Remove the HMI from water heater.. 5 6 720 882 320 (2018/04) Connecting cable

Explanation of symbols and safety instructions 3 1 Explanation of symbols and safety instructions 1.1 Guideline to symbols Warnings Warnings in this document are identified by a warning triangle printed against a grey background. Keywords at the start of a warning indicate the type and seriousness of the ensuing risk if measures to prevent the risk are not taken. Keywords at the start of a warning indicate the type and seriousness of the ensuing risk if measures to prevent the risk are not taken. The following keywords are defined and can be used in this document: DANGER indicates a hazardous situation which, if not avoided, will result in death or serious injury. WARNING indicates a hazardous situation which, if not avoided, could result in death or serious injury. CAUTION indicates a hazardous situation which, if not avoided, could result in minor to moderate injury. 1.2 Safety instructions Installation and commissioning Observe all federal, state and local regulations and standards during installation and operation! Observe all instructions to ensure satisfactory operation. Install and commission heat source and other accessories according to the relevant instructions. Before installing the remote control cable: isolate all poles of heat source and all other BUS subscribers from the power supply, secure against unintentional reconnection and make sure the power supply is disconnected. Electrical components must be installed by a trained electrician and the installation must meet the National Electric Code as well as all applicable local codes and regulations. Risk of damage from operator error Operator errors can cause injury and damage to property: Instruct the customer in the functions and operation of the remote control. Make sure that only individuals who can operate the remote control correctly have access to it. NOTICE: Contains no warning triangle and indicates a situation that could result in damage to property or equipment, but no personal injury. Important information This symbol indicates important information where there is no risk to people or property. Important information for the proper use of the boiler is also provided in this manual. You will find the information with a symbol shown on the left and bordered by horizontal lines above and below the text. Additional symbols Symbol Explanation Sequence of steps Cross-reference to other points in this document or to other documents Listing/list entry Listing/list entry (2nd level) Table 1 Connecting cable 6 720 882 320 (2018/04)

4 Information about the accessory General information This manual is available in English. Keep this manual for future use. Observe the safety instructions of this manual before putting the heating appliance into operation. If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. What to do if you smell gas Do not try to light any appliance. Do not touch any electrical switch; do not use any phone in your building. Immediately call your gas supplier from a neighbor s phone. Follow the gas supplier s instructions. If you cannot reach your gas supplier, call the fire department. Installation and service must be performed by a trained and certified heating contractor, service agency or the gas supplier. Risk of scalding If running at DHW temperatures above 104 F (40 C) ask a trained and certified heating contractor to install a tempering valve to prevent scalding. When the thermal disinfection function is enabled, DHW temperatures above 140 F (60 C) can occur. Risk of damage due to operator error Operator errors can result in personal injury and damage to property. Ensure that children never play with or operate this appliance unsupervised. Ensure that only people who know how to operate this appliance correctly have access to it. Never modify any parts. 2 Information about the accessory 2.1 Cable specifications Length 2.2 Proper use The cable is intended to connect the water heater with the HMI. Any other purpose is considered improper use. Any resulting damage is excluded from the manufacturer's warranty. 3 Scope of delivery Fig. 1 Scope of delivery [1] Cable [2] Technical documentation [3] Cable tie 33 feet (10 meters) Characteristics UL 21179 / 2x20AWG Table 2 Cable specifications 6 720 882 320 (2018/04) Connecting cable

Installation instructions 5 4 Installation instructions The HMI is inside the water heater. 4.2 Remove the HMI from water heater Loosen the two Phillips head screws located on the bottom of the front cover. Remove the front cover by lifting and pulling towards you. Fig. 2 Outdoor appliance 4.1 Safety instructions Before removing the front cover: Disconnect the appliance from the power supply. Turn off the gas shut-off valve. Fig. 4 Remove front cover Use a screw driver to open HMI. 1. 6720882320-09.1V Fig. 3 2. Disconnect cable from the HMI board. Fig. 5 3. Open HMI 6720882320-04.1V Connecting cable 6 720 882 320 (2018/04)

6 Installation instructions Choose the wire as center to mount the base. 1. 6720882320-12.1V 6720882320-10.1V Fig. 6 Disconnect cable Remove two Phillips screws from the HMI support base. Fig. 9 Wires inside the wall Remove the plastic knockout, when wires are outside the wall. 6720882320-11.1V Fig. 7 Removing base Secure the internal cable with a cable tie. Fig. 10 Wires outside the wall Mount the HMI base onto the wall. 2.37in (60mm) 6720882320-06.1V Fig. 8 Secure internal cable Fig. 11 Installing base 6 720 882 320 (2018/04) Connecting cable

Installation instructions 7 Connect the cable to the HMI. Turn on the gas shut-off valve. 6720882320-16.1V Fig. 15 Connect the appliance 6720882320-13.1V Fig. 12 Connection of the HMI Assemble the HMI interface to the base. Fig. 13 Assemble HMI Connect the cable to the water heater and HMI. 6720882320-14.1V 1. 6720882320-15.1V Fig. 14 Connect cable Connect the cable to the water heater and HMI. After mounting the front cover in the appliance: Connect the appliance to the power supply. Connecting cable 6 720 882 320 (2018/04)

6720882320