Dräger PEX 3000 Flammable Gas Detection

Similar documents
Dräger QuadGard Control System

Catalytic Bead DrägerSensor Sensors for Fixed Gas Detectors

Dräger PIR 7000 Flammable Gas Detection

Dräger Polytron 8200 Stationary gas detector (CatEx)

Dräger Polytron SE Ex Fixed Gas Detector

Dräger PIR 3000 Detection of flammable gases and vapours

Dräger Polytron 5720 IR Detection of carbon dioxide

Dräger Flame 5000 Flame Detection

Dräger Catalytic Ex-Sensors DrägerSensors

Dräger Polytron 8000 Stationary gas detector (EC)

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Dräger Polytron 5720 IR Toxic Gas Detection

Dräger Bump Test Station Calibration and Bump Testing

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Dräger Polytron 8720 IR Detection of carbon dioxide

Catalytic Bead DrägerSensors for Fixed Gas Detectors

The SharpEye 40/40R (IR) Flame Detection

Dräger X-am 5000 Multi-Gas Detection

Dräger Polytron Pulsar 2 Detection of flammable gases and vapours

Dräger X-am 2500 Multi-Gas Detection

Dräger REGARD -1 Control System

Dräger Configuration and Evaluation Software

Electrochemical DrägerSensor Sensors for Fixed Gas Detectors

Dräger Catalytic Ex-Sensors DrägerSensors

Dräger REGARD 3900 Series Control System

Powder Extinguisher ABC (stored pressure) Portable powder extinguishers

Dräger PointGard 2100 Detection of toxic gases and vapours

Dräger Polytron 8100 EC Detection of toxic gases and vapors

Dräger Polytron 8310 Stationary gas detector (DSIR)

Dräger X-am 7000 Multi-Gas Detection

Dräger PIR 7200 Detection of toxic gases and oxygen

Dräger Polytron 8100 EC Detection of toxic gases and oxygen

Dräger GS01 (wireless) Detection of flammable gases and vapours

Dräger Pac 7000 Single-Gas Detection Device

The SharpEye 40/40M (Multi IR) Flame Detection

ST More than the sum of their components GAS DETECTION SYSTEMS

Dräger VVP 1000 System Components

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Dräger FRT 1000 / ETR 1000 Location Devices

Dräger Polytron Pulsar 2 Open Path Gas Detector

The SharpEye 40/40L4-L4B (UV/IR) Flame Detection

GS01 (wireless) Detection of flammable gases and vapours

Dräger Flame 5000 Flame Detection

Dräger Pulsar 7000 Series Detection of flammable gases and vapours

Dräger Polytron 8200 CAT Detection of flammable gases and vapors

Dräger Pac 5500 Single-Gas Detection Device

Dräger X-plore 8000 Powered Air-Purifying Respirator (PAPR)

Dräger X-am 2500 Multi-Gas Detector

Dräger X-pid 9000 / 9500 Multi-Gas Detection

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Foam Extinguisher AB - composite Portable foam extinguishers

Dräger REGARD -1 Control System

Powder Extinguisher ABC - composite Portable powder extinguishers

The SharpEye 40/40I (IR3) Flame Detection

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Dräger Polytron 7000 Detection of toxic gases and oxygen

Portable wet chemical extinguishers

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Transmitter PEX 3000 Instructions for Use

Dräger REGARD -1 Control System

Dräger P4000 Pressure and Leak Testing

Dräger VARIOx-2. Electronical measuring device for the gas concentration measurement

Training Authorised Gas Tester Level 1. Basic Information

Dräger Flame 2700 (Multi-IR) Flame Detection

Dräger X-am 5000 Multi-Gas Detector

Dräger Flame 2500 (IR3) Flame Detection

VarioVac vacuum regulators Consumables and Accessories

On-site & Shutdown Safety Service CSE Monitoring

Dräger Polytron Pulsar 2 Detection of flammable gases and vapours

Training Gas Detection Level 2 User and Calibration. Basic Information

Dräger Flame 2350 (UV&IR) Flame Detection

Dräger Flame 2370 (UV&IR) Flame Detection

Dräger Polytron 8310 IR Detection of flammable gases and vapour

ST More than the sum of their components GAS DETECTION SYSTEMS

Training Gas Detection Level 3 Maintenance and Repair

Dräger PIR 7200 Toxic Gas Detection Transmitter

THE ULTIMATE SOLUTION FOR GAS DETECTION SYSTEMS. DRÄGER REGARD

Dräger Pac 3500 Single-Gas Detection Device

VarioAir Medical Suction Solutions Consumables and Accessories

Dräger Pac 6000 Single-Gas Detection Device

Dräger Flame 2100 (UV) Flame Detection

Electrochemical (EC) DrägerSensors for Fixed Gas Detectors

Dräger Pac 8000 Single-Gas Detection Device

Dräger X-am 5000 Multi-Gas Detection

ST Explosion Protection GAS DETECTION SYSTEMS

The SharpEye 40/40I (IR3) Flame Detection

Dräger Bodyguard 1000 Warning Device

Dräger Pac 8500 Single-Gas Detection Device

Dräger X-zone 5500 Portable gas detection system for flexible area monitoring

PrimaX IR Gas Transmitter Designed for Reliable Performance in Extreme Conditions

Dräger X-zone 5500 Area Monitoring

ULTIMA XIR ULTIMA X 3 ULTIMA XE. ULTIMA X Series. [ State-of-the-Art Gas Monitoring]

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

Dräger Flame 2100 Flame Detection

Dräger Polytron 8000 Stationary gas detector (EC)

APPLICATION DATA SHEET

3M Oldham OLCT 100. Description. Fixed Gas Detector

PolyGard Single Point Controller SPC-X3-34XX for Combustible Gases

Dräger X-zone 5500 Multi-Gas Detection Device

Transcription:

Dräger PEX 3000 Flammable Gas Detection The transmitter Dräger PEX 3000 detects flammable gases and vapors in concentrations below their Lower Explosion Limit Its DD-sensor provides a very long-term stable measuring signal and responds to gas in only a few seconds D-11158-2011

02 Dräger PEX 3000 Benefits Six variants of transmitters You can choose between two measuring ranges (0 100 or 0 10 %LEL) and two different junction box sizes The larger junction box provides optional horizontal or vertical cable entry Where the application asks for the sensor to be mounted remote from the junction box then it is possible to use the remote cable assembly combined with the sensing head of type Polytron SE Ex Simple installation The three core screened cable from the control system terminates within the junction box of the Dräger PEX 3000 by means of three Ex-approved spring terminals The sensor connects to three different Ex-approved spring terminals Ex-approved spring terminals are not selfloosening and are inherently more reliable then standard screw terminals, therefore self-loosening is no longer an issue! One-man Calibration Owing to the state-of-the-art design of the Dräger PEX 3000 it is possible to open the Ex e junction box in the hazardous area to perform maintenance and calibration Using the two internal push buttons and the internal seven segment digital display you can perform many different activities including one-man calibration No additional hardware is required, eg a hand held terminal Explosion Protection The Dräger PEX 3000 is approved according to the EU-Directive 94/9/EC to be operated at ambient temperatures ranging from - 40 up to + 65 C This applies to both explosive gas atmospheres and explosive dust atmospheres (Zones 1, 2, 21, and 22) Low gas concentrations For applications where it is necessary to detect low concentrations then the transmitters Dräger PEX 3000 type XTR 0010 or XTR 0011 with their special low-drift LC sensor are very suitable These transmitters reliably detect gas leaks of concentrations up to 10 %LEL Newly developed: DD sensor The new DD sensor is based on the well-known catalytic bead technology from Dräger and is designed and manufactured by Dräger for long term stability and resistance against sensor poisons Furthermore, the new DD sensor uses an innovative non-sintered disc gas inlet therefore the reaction time towards the target gas in now only a few seconds This fast speed of detection allows for countermeasures to be initiated earlier, therefore guarding against the formation of an explosive atmosphere

Dräger PEX 3000 03 System components Catalytic Bead DrägerSensors The Dräger Catalytic Bead Sensors is designed for the continuous monitoring and detection of combustible gases and vapours with different versions for different applications or concentrations D-27777-2009 D-1119-2010 Dräger REGARD 3900 The Dräger REGARD 3900 is a standalone, self contained control system for the detection of Toxic, Oxygen and Ex hazards The control system is fully configurable between 1 and 16 channels, depending upon the type and quantity of input/output boards installed Dräger REGARD control system Tried and tested thousands of times and infinitely flexible The modular Regard control system can be individually adapted to any monitoring task Suitable for SIL 2 systems, the Regard system is also ATEX approved, and meets EMC directive standards ST-335-2004 2-669-95 Dräger REGARD-1 The Dräger REGARD-1 is a standalone, self contained single channel control system for the detection of Toxic, Oxygen and Ex hazards The control system is fully configurable for a single input from either a 4 to 20 ma transmitter or a Dräger Polytron SE Ex measuring head

04 Dräger PEX 3000 Accessories Calibration chamber A metal chamber to vaporise combustible liquids to develop vapours (eg acetone, benzene, hexane, nonane etc) Used to for zero-point tests and calibration Order No: 68 02 206 Splash guards Guards the DrägerSensors of transmitters with electrochemical sensors (not type L), catalytic sensors (pellistors) and transmitters of type Polytron IR CO 2 and Polytron IR Ex HC against splashing water Order No: 68 07 549 ST-5678-2006 ST-5687-2006 Calibration Adapter Adapter for test of zero point and calibration for transmitters with electrochemical sensors (not type L), catalytic bead sensors (Pellistors) and the transmitters of the type Dräger Polytron IR CO 2 and Dräger Polytron IR Ex HC Order No: 68 06 978 Remote calibration adapter For calibrations of transmitters with electrochemical sensors (not type L), catalytic sensors (pellistors) and transmitters of type Polytron IR CO 2 and Polytron IR Ex HC that are mounted in difficult to access positions Order No: 68 07 955 ST-5679-2006

Dräger PEX 3000 05 Related Products Dräger PIR 7000 The Dräger PIR 7000 is an explosion proof point infrared gas detector for continuous monitoring of flammable gases and vapours With its stainless steel SS 316L enclosure and drift-free optics this detector is built for the harshest industrial environments, eg offshore installations D-14979-2010 ST-11659-2007 Dräger Polytron 5700 Quick, reliable and cost-effective detection of combustible gases and vapors in ambient air: the microprocessor-based transmitter is the result of more than 40 years of experience in measurement technology and contains a new, innovative IR sensor with drift-free optics These optics are extremely resistant against deposits and insects in the beam Dräger PIR 3000 The Dräger PIR 3000 is an explosion proof infrared gas detector for continuous monitoring of combustible gases and vapors Based on a stainless steel SS 316 enclosure as well as on a good measuring performance, this transmitter offers an excellent price-performanceratio ST-8822-2005

06 Dräger PEX 3000 Technical Data Type 4-to-20-mA-transmitter with catalytic bead sensor Gases and vapors Flammable gases and vapors in the ambient air such as acetone, acetylene, ammonia, benzene, 13- butadiene, n-butane, n-butyl acetate, diethyl ether, dimethyl ether, ethanol, ethyl acetate, ethylene (ethene), ethylene oxide, n-hexane, hydrogen, methane, methanol, methyl ethyl ketone (MEK), methyl methacrylate, n- nonane, n-octane, n-pentane, petrol 065/095, propane, i-propanol, propylene (propene), propylene oxide, toluene and o-xylene Measuring range Typ XTR 0000, XTR 0001 Typ XTR 0010, XTR 0011 Power supply 12 to 30 V dc (nominal 24 V dc), max 110 ma at 24 V 0 to 100 %LEL 0 to 10 %LEL Signal output Normal operation 4 to 20 ma Maintenance 34 ma Fault condition < 12 ma Cabling max cable length (at 24 V, 250 Ohms) Response time (at 25 C, methane) Ambient conditions Housing material 3-core, shielded, core cross-section 075 to 15 mm 2, outer diameter 7 to 12 mm 2400 m at 3 x 15 mm 2, 1600 m at 3 x 10 mm 2, 1200 m at 3 x 075 mm 2 Type XTR 0000, XTR 0001 Type XTR 0010, XTR 0011 Temperature Pressure Ingress Protection IP 66 Dimensions (W x H x D) Weight Expected sensor lifetime Explosion protection Performance approval Functional Safety (100 %LEL variants only) t50: 3 5 s, t50 < 9 s, t90: 8 10 s t90 < 20 s - 40 to + 65 C (depending on temperature class) 700 to 1300 hpa Humidity 5 to 95 % r H glass fiber reinforced polyester (GRP) Type XTR 00x0 Type XTR 00x1 ca 600 g typical > 3 years except XTR 009x: II 2G Ex de IIC T6/T5/T4 Gb ca 80 x 130 x 55 mm ca 135 x 110 x 55 mm II 2D Ex t IIIC T80/95/130 C Db IP6X XTR 009x: II 2G Ex de IIC T6 Gb II 2D Ex t IIIC T80 C Db IP6X acc to EN 60079-29-1 for the am gases and vapors (100 %LEL variants only) Average probability of failure on demand (TP = 1 year) PFD = 556E-04 Safe failure fraction (HFT = 0, Type B) SFF = 904 % - 40 Ta + 40 / 55 / 65 C - 40 Ta + 65 C Ordering Information PEX 3000, Type XTR 0000, small housing, 0 to 100 %LEL 83 18 280 PEX 3000, Type XTR 0001, medium-sized housing, 0 100 %LEL 83 18 360 PEX 3000, Type XTR 0010, small housing, 0 10 %LEL 83 18 290 PEX 3000, Type XTR 0011, medium-sized housing, 0 10 %LEL 83 18 370 PEX 3000, Type XTR 0090, small housing, remote transmitter without sensor PEX 3000, Type XTR 0091, medium-sized housing, remote transmitter without sensor 83 18 380 83 18 390 Dust filter for DrägerSensor PR M DD (PE-disks, 10 pieces) 68 10 537 Calibration adapter (PE) 68 06 978 Process adapter (stainless steel) for PEX 3000 XTR 0000, XTR 0001 Process adapter (stainless steel) for PEX 3000 XTR 0010, XTR 0011 68 12 470 68 12 465

Notes Dräger PEX 3000 07

08 Dräger PEX 3000 Notes 90 41 354 15-05-3 Marketing Communications PP LE Printed in Germany Chlorine-free environmentally compatible Subject to modifications 2015 Drägerwerk AG & Co KGaA CORPORATE HEADQUARTERS Drägerwerk AG & Co KGaA Moislinger Allee 53 55 23558 Lübeck, Germany wwwdraegercom Manufacturer: Dräger Safety AG & Co KGaA Revalstraße 1 23560 Lübeck, Germany Locate your Regional Sales Representative at: wwwdraegercom/contact SYSTEM CENTERS P R CHINA Draeger Safety Equipment (China) Co, Ltd A22 Yu An Rd, B Area, Tianzhu Airport Industrial Zone, Shunyi District, Beijing 101300 Tel +86 10 80 49 80 00 Fax +86 10 80 49 80 05 GERMANY Dräger Safety AG & Co KGaA Revalstrasse 1 23560 Lübeck Tel +49 451 882-2794 Fax +49 451 882-4991 UNITED KINGDOM Draeger Safety UK Ltd Blyth Riverside Business Park Blyth, Northumberland NE24 4RG Tel +44 1670 352 891 Fax +44 1670 544 475 REGION EUROPE SOUTH Dräger Safety France SAS 25, rue Georges Besse 92182 Antony Cedex, France Tel +33 1 46 11 56 00 Fax +33 1 40 96 97 20 EuropeSouth@draegercom USA Draeger Safety, Inc 505 Julie Rivers, Suite 150 Sugar Land, TX 77478 Tel +1 281 498 1082 Fax +1 281 498 5190 infogds@draegercom REGION ASIA PACIFIC Draeger Safety Asia Pte Ltd 25 International Business Park #04-20/21 German Centre Singapore 609916 Tel +65 6308 9400 Fax +65 6308 9401 asiapacific@draegercom REGION CENTRAL AND SOUTH AMERICA Dräger Panama Comercial S de RL Complejo Business Park, V tower, 10th floor Panama City Tel +507 377-9100 Fax +507 377-9130 contactcsa@draegercom REGION MIDDLE EAST, AFRICA Dräger Safety AG & Co KGaA Branch Office PO Box 505108 Dubai, United Arab Emirates Tel +971 4 4294 600 Fax +971 4 4294 699 contactuae@draegercom