Pac Ex 2. Elegant and smart Explosive hazards and lack or surplus of oxygen under control

Similar documents
micropac. Personal Gas Detection Instruments

Dräger Pac Ex 2. Elegant and smart... Explosive hazards and lack or surplus of oxygen under control

Dräger X-am Dräger X-am 7000: Modular, rugged and waterproof.

Dräger X-am Dräger X-am 3000: Designed for the harshest industrial environments.

Dräger X-am 7000 Multi-Gas Detection

Dräger X-am 2500 Multi-Gas Detection

Dräger X-am 7000 Multi-Gas Detection

Dräger X-am 5000 Multi-Gas Detection

Dräger X-am 2500 Multi-Gas Detector

Dräger X-am 5000 Multi-Gas Detection

Dräger X-am 5600 Personal Monitor Multi-Gas Detection Device

Dräger X-am 5000 Multi-Gas Detector

ALTAIR 5X Multigas Detector Product Specification

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

GasAlertMicroClip X3 Specifications

Dräger Polytron 7000 Fixed gas detector

GMS800 FIDOR TOTAL HYDROCARBON ANALYZER CONTINUOUS MONITORING OF HYDROCARBON EMISSIONS

Dräger Pac 7000 Single-Gas Detection Device

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

Dräger PIR 3000 Detection of flammable gases and vapours

PRODUCT INFORMATION. GM901 Carbon Monoxide Gas Analyzers CO MEASUREMENT FOR EMISSION MONITORING AND PROCESS CONTROL. In-situ Gas Analyzers

Dräger PointGard 2100 Detection of toxic gases and vapours

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Dräger X-zone 5500 Area Monitoring

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Dräger Polytron 5720 IR Toxic Gas Detection

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

Dräger X-am 2500 (MQG 0011) Technical Manual

Confined Space Monitoring. Leak Investigation. Functions 4. Bar Hole Sampling. Line Purge Testing. Actual Size GX-2012

Dräger Polytron 5720 IR Detection of carbon dioxide

Dräger Pac 5500 Single-Gas Detection Device

IT S WHAT S INSIDE THAT COUNTS

IT S WHAT S INSIDE THAT COUNTS

Dräger Pac 6000 Single-Gas Detection Device

Dräger Polytron 5100 EC Detection of toxic gases and vapors

PERSONAL COMBUSTIBLE GAS DETECTOR

PRODUCT INFORMATION. SureSense THE SURE WAY TO DETECT ANY OBJECT. Photoelectric Sensors

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Dräger X-zone 5500 Area Monitoring

Dräger Polytron 8100 EC Detection of toxic gases and oxygen

Dräger Pac 8500 Single-Gas Detection Device

Dräger Polytron 8200 Stationary gas detector (CatEx)

Dräger QuadGard Control System

1.1 Definitions of alert icons. For your safety

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

VICOTEC450 EXTRACTIVE VISIBILITY MEASURING DEVICES EXTRACTIVE VISIBILITY MEASUREMENT FOR INCREASED SAFETY IN TUNNELS

Dräger X-zone 5500 Multi-Gas Detection Device

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Dräger PIR 7000 Flammable Gas Detection

ia d ATEX 100 II 2G D MT 99 ATEX G 001 x EX-METER II Series [ Versatility in Explosive Atmospheres]

Dräger Pac 8000 Single-Gas Detection Device

Dräger Pac 3500 Single-Gas Detection Device

Dräger Polytron 8100 EC Detection of toxic gases and vapors

Dräger Catalytic Ex-Sensors DrägerSensors

Dräger X-am approved as type MQG 01** Multi-Gas Monitor. Technical Handbook. CO2 Vol% CH4 %UEG. CO ppm. ppm NH _01.

Dräger Pac 3500 Single-Gas Detection Device

Quality. Water. Water Quality. Testing. Testing. Toxic Gas Detection. Toxic Gas. Detection. Air Quality. Monitoring. Monitoring. Monitoring.

Dräger Polytron 8310 Stationary gas detector (DSIR)

Dräger Polytron 8200 CAT Detection of flammable gases and vapors

Dräger Configuration and Evaluation Software

MultiRAE Lite. Wireless Portable Multi-Gas Monitor

IT S WHAT S INSIDE THAT COUNTS

Dräger X-am approved as type MQG 0010 Multi-Gas Monitor Technical Manual _01.eps

Dräger Polytron 8720 IR Detection of carbon dioxide

Press Release. Short profile Beckhoff. Short profile February 2009 Page 1 of 6

Dräger Polytron 8000 Stationary gas detector (EC)

Polytector III G999 for Ex zone 0

Dräger Pac 8500 Single-Gas Detector

Dräger Pac 6000 Single-Gas Detector

EAGLE 2. 6 Channel Capacity. Inlet fitting. Loud buzzer (95dB) IrDA communication port Low flow shutoff and alarm Alarm LED s with wide visibility

Dräger Catalytic Ex-Sensors DrägerSensors

Accuracy counts! Sensors with analog output

PHD6. Flexible, comprehensive monitoring backed up by high performance functionality

PRODUCT INFORMATION HISIC450 OVERHEIGHT DETECTORS RELIABLE OVERHEIGHT DETECTION OF VEHICLES. Traffic sensors

testo 316-EX gas leak detector Instruction manual

Dräger REGARD -1 Control System

Dräger REGARD -1 Control System

OO Measuring range from bar rel. OO Large selection of pressure sensors. OO Automatic sensor recognition

Monitores Personales. Personal Monitor

VENTIS PRO SERIES. Product Guide

Dräger PIR 7200 Toxic Gas Detection Transmitter

High vacuum guide FOR PRE-SEPARATORS AND CYCLONES

Dräger Polytron 8310 IR Detection of flammable gases and vapour

Leading manufacturer of high-end ball valves and pneumatic actuators. Over 60 years experience with industrial applications

IT S WHAT S INSIDE THAT

KNX The worldwide STANDARD for home and building control. KNX Association International

Dräger X-dock 5300/6300/6600 Calibration and Bump Testing

GAS DETECTORS EXPLOSIMETERS/CATHAROMETERS EX 2000/EX 2000 C/GD 2000/GDP Your environment, your safety, let s master them together

Beckhoff short profile

Dräger X-zone 5500 Portable gas detection system for flexible area monitoring

CO warning instruments and gas spillage detectors

Detection, Protection, Innovation

HazLoc Essential Guides:

Dräger Polytron Pulsar 2 Open Path Gas Detector

Dräger Polytron 7000 Detection of toxic gases and oxygen

Dräger PEX 3000 Flammable Gas Detection

Dräger PIR 7200 Detection of toxic gases and oxygen

For the Safety of Your

multi-gas detector Go the distance, and save Wear yellow. Work safe.

Transcription:

Pac Ex 2 Elegant and smart Explosive hazards and lack or surplus of oxygen under control

Portable instruments protecting people against explosive hazards and lack or surplus of oxygen are used in a large range of different applications such us: alerting employees to a sudden emission of gas, certification of safe work areas, monitoring staff working in areas where low concentrations of gas are constantly present, measurement for confined space entry or in difficult-to-reach areas, protecting visitors on a tour of the plant, evaluation of dangers during emergency situations involving fire services or civil defence organisations. 2

Two-in-one-instrument Pac Ex 2, Ex-Version Pac Ex 2, Ex-O 2-Version ST-192-98 2-1008-98 Two-in-one-instrument The diverse applications necessary for day-to-day work demand high performance requirements from a measuring device. Knowing this, Dräger Safety has developed the new Pac Ex 2. With a compact, handy and pocketsized design, this robust instrument can be used for personal monitoring. The instrument measures for explosive hazards and a lack or surplus of oxygen. PacEx2 is available in two instrument versions: instrument for ex gas measurement, combination instrument for ex gas and oxygen measurement. In combination with an extensive range of accessories, the Pac Ex 2 is the ideal portable instrument for: fire services, chemical industry, oil and gas industry, electrical and water utilities, disposal companies, telecommunication enterprises, mining industry, shipping industry. 2-33-97 2-33-97 3

Continuously, independtly, flexible Continuously, independently, flexible The concentrations of explosive gas or vapours and oxygen are monitored continuously, simultaneously, and independently. Combined with a vibrating alarm, an acoustic and optic alarm react when the gas concentration exceeds the set alarm thresholds. The modular design enables high instrument flexibility: The ex gas detection instrument can be easily upgraded to an ex gas and oxygen detection instrument. This flexibility is made possible by the plug and play function of the oxygen sensor and a simple to change sensor cap. The rechargeable NiMHy battery can be easily changed and is separately chargeable. Additional to the rechargeable NiMHy battery, an alkaline battery pack can be used. The selection of three different oxygen sensors is possible. The Pac Ex 2 incorporates the needs of the customer with the power of technology. Along with the basic functions warning, measuring, and datalogging, the main characteristics of the instrument are: simple operation, reliability, extra long operation time, cost-savings caused by a longer sensor life, short training times, and short charging times. ST-166-2002 Functional three-button-operation Using three clearly arranged pushbuttons the Pac Ex 2 can easily be adapted to fit diverse measuring requirements and applications. A multitude of features are available. The selection will be made through two menus: for fresh-air-calibration and a read-out of the four-hour-ex-average concentration, for password protected configuration and calibration of the instrument. ST-166-2002 4

Safety first optimum sensor technology No limits in measurement quality is the standard policy of Dräger Safety. The heart of a detection instrument is the sensor. The sensors are essential for the measuring result and the reliability of the detection instrument. For the ex measurement the Pac Ex 2 is equipped with a special robust catalytic ex sensor. The sensor reacts to present combustible gases or vapours and works with the principles of heat reaction and thermal conductivity. This sensor has a high performance because: it has short response time, it has a robust construction, it can be calibrated to various gases and vapours in the LEL range, it can be calibrated to methane in the % vol range, it is designed for low power operation, it has a warranty of 2 years, it has an expected sensor life longer than 2 years. Three kinds of oxygen sensors can be used: XS-R O 2 warranty 5 years expected sensor life 5 years XS-EC O 2 warranty 3 years expected sensor life > 3 years XS-2 O 2 warranty 2 years expected sensor life > 2 years Naturally, the electrochemical Sensors have also a high performance: intelligent Smart-Technology, internal data memory within the sensor, calibrated by the manufacturer, high selectivity, short response time, minimal long-term drift with low follow up costs and long calibration frequencies: default 12 months recommended 6 months, known and controllable cross sensitivities. 2-604-93 By using the intelligent Smart- Technology, the sensor must only be plugged into the instrument. The sensor will be recognized automatically by the Pac Ex2. 5

Adjustable instrument features Menus The Pac Ex 2 offers two menus, a quick menu and a password protected menu. When there is no activity within one minute (in the calibration menu within 15 minutes), the instrument automatically switches over to the measuring function. Quick menu Read-out of the four-hour-ex-average concentration. Fresh-air-calibration function. With this function, the oxygen sensor can be span calibrated, and the Ex sensor can be zero calibrated. Password protected menu Set up of password The password consists of a four-digit, self-defined number code. Two measuring units for ex measurement The measuring unit can be adjusted to either the LEL range or the % vol range. Ex calibration By using the LEL range, the instrument can be calibrated to various gases and vapours. In the % vol range, it can be calibrated to methane. Two adjustable alarm thresholds The alarm thresholds can be set to any value within the measuring range, providing that the pre-alarm threshold (A 1) is always lower than the main alarm threshold (A 2). PC-Software Gas Vision Using a PC with installed software Gas Vision, the stored values in the datalogger are readable. Using Windows, display and analysis of all the measurement values is possible. The values can be shown graphically and in table-form. Naturally, all data can be stored in the PC and can be exported to other software programs such as MS Excel. PC-Software CC Vision Using a PC with installed software CC Vision, Pac Ex 2 can be individually configured according to different requirements. Along with the instrument configuration, it is also possible to calibrate the device. Additionally, Pac Ex 2 can be adjusted to English, French, German, and Spanish languages. 6

Technical data Adjustment of measuring units Ex-measurement: 0 to 100 % LEL, resolution 1 %-LEL 0 to 99 vol.-% CH 4 resolution 0.1 vol.-% (0 to 5 vol.-%) resolution 1 vol.-% (0 to 99 vol.-%) Oxygen measurement: 0 to 25 Vol.-%, resolution 0.1 vol.-% Principle of measurement Ex-measurement: heat reaction and thermal conductivity Oxygen: electrochemical Ambient conditions Temperature: 25 to 55 C, intermittently to 60 C Humidity: 10 to 90 % r. h. intermittently to 95 % r. h. non condensing Pressure: 700 to 1300 hpa Ingress protection: IP 65 Power packs and operation time rechargeable NiMHy battery, changeable and separately chargeable Operation time: > 12 hours Charging time: < 4 hours Alkaline battery pack, 4 AAA cells Operation time > 12 hours Dimensions including power pack Size (h x w x d): approx. 125 x 64 x 35 mm top: approx. 82 mm Weight: approx. 320 g Alarming Optic, acoustic and vibrating alarm, two adjustable alarm thresholds for LEL range and oxygen measurement. Ex-measurement: default A 1: 10 %-LEL default A 2: 20 %-LEL Oxygen measurement: default A 1: 19 Vol.-% default A 2: 23 Vol.-% Sound volume: > 90 db (A) in a distance of 30 cm Datalogger Datalogger adjustable with Gas Vision Approvals 1) Europe CE mark IM 2 EEx iad IIC T4 Ta < 55 C II2G EEx ibd IIC Ta < 55 C Demko 02 ATEX Ta (-40 to 55 C) USA UL Class 1 Groups A, B, C, D Div. 1 Temp code T4 Canada CSA Class 1 Groups A, B, C, D Div. 1 Temp code T4 Shipping Steering Wheel Certification Ordering information and accessories Description Order code Basic units Pac Ex 2 Ex O 2 Version 83 16 107 Pac Ex 2 Ex Version 83 16 108 Charging accessories Charging module 1, 110-240 VAC for charging of 1 instrument 83 16 360 Charging module 2, 110-240 VAC 83 16 345 for charging of 1 instrument, additional separate battery charging and connection to CC / Gas Vision Car charging adapter, 12/24 V 83 16 115 Pump Adaptable automatic pump 83 16 350 Hand pump 68 01 933 (in conjunction with calaibration adapter) Power supply units Rechargeable NiMHy Battery 83 16 112 Alkaline Battery Pack (w/o Batteries) 83 16 111 Datalogging and Configuration accessories Gas Vision 83 14 034 CC Vision 64 08 515 Data transmission cable 64 08 257 RS 232 cable 9-9 including adapter from 9 to 25 pins Extension hoses and probes (use in conjunction with adaptable automatic pump or hand pump) Extension hose, 10 m incl. float probe 68 07 097 Float probe, w/o hose 68 02 337 Telescopic probe, installable 68 01 954 Telescopic probe, extendable 83 13 025 Calibration accessories Calibration adapter 83 16 300 Sensors Cat Ex sensor 0 to 100 %-LEL, 0 to 100 Vol.-% CH 4 83 16 109 XS R O 2 sensor, 0 to 25 Vol.-% 68 10 262 XS EC O 2 sensor, 0 to 25 Vol.-% 68 09 130 XS 2 O 2 sensor, 0 to 25 Vol.-% 68 10 375 Other accessories Rubber boot 83 16 116 Carrying case 83 16 117 7 1) pending

Dräger Safety AG & Co. KGaA Revalstrasse 1 D-23560 Luebeck Germany Tel. +49 451 882-0 Fax +49 451 882-20 80 www.draeger-safety.com DrägerService Dräger equipment must always be fully operational and safe. DrägerService offers a regular inspection service and isquickly available in the event of malfunction. Your equipment will be repaired and back in operation as quickly as possible. Dräger- Service facilitates the vital flow of information between client and manufacturer. Dräger Expertise Since 1889, Dräger has had an outstanding reputation for solving problems in the field of human breathing. Dräger has been deeply involved in the handling of gases, in particular hazard protection and the saving of life in medical and industrial emergencies. Many of the company's 9500 employees are active in research and innovation to ensure that the latest techniques and scientific advances are fully tested before their inclusion in new equipment. Quality and Environmental Management Our mission includes the continuous improvement of our Quality and Environmental Management Systems in accordance with ISO 9001 and ISO 14001. Dräger Worldwide The Dräger sales and service organisation is spread throughout the world. It comprises more than 25 subsidiaries and associated companies to ensure that Dräger is always within easy reach of its clients and in close contact with all important markets. Dräger's ever increasing market share demonstrates the company's international competitiveness and strength. Dräger has subsidiaries in the following countries: Australia, Austria, Belgium, Bulgaria, Canada, China, Croatia, Czech Republic, Denmark, France, Great Britain, Hungary, Indonesia, Italy, Japan, the Netherlands, Norway, Romania, Singapore, Slovenia, Slowakia, South Africa, Spain, Sweden, Switzerland, Thailand, Yugoslavia, USA. Additionally, Dräger is widely represented in Central and South America, Africa, the Middle East, the Far East and Eastern Europe. 90 44638 / PB e / 082 / H-L--DD / Corporate Communications / Printed in Germany / chlorinefree ecological / Subject to modifications!