OBSEG METOD S FLEKSIBILNIM OBSEGOM AKREDITACIJE. Oddelek za kemijske analize živil, vod in drugih vzorcev okolja, Gosposvetska ulica 12, 4000 Kranj

Similar documents
PRILOGA K AKREDITACIJSKI LISTINI Annex to the accreditation certificate LP-047

PRILOGA K AKREDITACIJSKI LISTINI Annex to the accreditation certificate LP- 018

PRILOGA K AKREDITACIJSKI LISTINI Annex to the accreditation certificate LP- 018

PRILOGA K AKREDITACIJSKI LISTINI Annex to the accreditation certificate LP-004

This annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation

PRILOGA K AKREDITACIJSKI LISTINI Annex to the accreditation certificate LP-076

Metode preskušanja cementa - 1. del: Določanje trdnosti Methods of testing cement - Part 1: Determination of strength

Seznam akreditiranih metod Laboratorij za cemente, malte in keramiko

Test procedure/ method identification IP 100 (ISO 9096, ČSN EN )

Ministerial Decree No. 14/2005 (VI. 28.) KvVM. on the rules concerning the screening surveys of remedial site investigations.

Seznam akreditiranih metod Laboratorij za cemente, malte in keramiko

PRILOGA K AKREDITACIJSKI LISTINI Annex to the accreditation certificate LP-107

PRILOGA K AKREDITACIJSKI LISTINI Annex to the accreditation certificate LP-076

PERFORMANCE EVALUATION OF DIFFERENT GREEN ROOF DESIGNS CHENGDU, CHINA

TEST REPORT Page 1 of 28. Uçar Oyuncak San.ve Tic.Ltd.Şti.

PRILOGA K AKREDITACUSKI LISTINI Annex to the accreditation certificate

Technical manual 2G-TA 04 - Gas

Seznam akreditiranih metod. Laboratorij za toplotno zaščito in akustiko

Chemistry Instrumental Analysis Lecture 29. Chem 4631

SEZNAM AKREDITIRANIH METOD V PRESKUSNEM LABORATORIJU IRMA (LP-008) / LIST OF ACCREDITED METHODS IN TESTING LABORATORY IRMA (LP-008)

Soil and Plant Methods List for Automated Ion Analyzers. Flow Injection Analysis

PRILOGA K AKREDITACIJSKI LISTINI Annex to the accreditation certificate LP-032

Soil. Acidic soils... 1/19/2014

This document is a preview generated by EVS

Anorganic Fertilizer. Lenny Sri Nopriani, SP.MP

Monitoring Nutrition for Crops

This document is a preview generated by EVS

Understanding the Balance

NM Water Resources Research Institute Environmental Conditions of the Animas and San Juan Watersheds with Emphasis on Gold King Mine

A Big Picture View of Halogenated Chemical Exposures in China

PRILOGA K AKREDITACIJSKI LISTINI Annex to the accreditation certificate LP- 099

F321: Atoms, Bonds and Groups Electron Structure

Pretreatments to LLE

The Road to Recovery. Mapping Advanced Sample Preparation Techniques for GC, GC-MS and HPLC Analysis

STS Directory Accreditation number: STS 0021

EFFECT OF MOLYBDENUM TRATMENTS ON GROWTH AND MOLYBDENUM UPTAKE OF GREEN PEA

Greenhouse Plant Nutrition

Nutrient Management And Nutrient Cycling Raymond C. Ward, President Ward Laboratories, Inc Kearney, NE

Fertilizers and nutrient management for hops. Diane Brown, Michigan State University Extension

The plating industry

Tim O Hare Associates LLP Howbery Park Wallingford Oxfordshire OX10 8BA T:

Soils and Fertilizers. Leo Espinoza Soils Specialist

Multiple-event study of bioretention for treatment of urban storm water runoff

Order all the parts and accessories needed at one time Reduced learning curve for rapid implementation

Part 3: Quality of Compost.

Declaration of Compliance BS3882:2015

PASTURE AND HAY FIELDS: SOIL FUNDAMENTALS. Sanders County April 8, Clain Jones

Effect of Storage Duration in the Quality of Vermicompost

Chi-hsu Hsieh*, and Allen P. Davis**,

High Carbon Wood Fly Ash as a Biochar Soil Amendment

INTERNATIONAL STANDARD

EESTI AKREDITEERIMISKESKUS ESTONIAN ACCREDITATION CENTRE

ATTACHMENT A BIORETENTION SOIL SPECIFICATION

Volume 10 Summer Understanding Terminology Key to Treatment Program Success

Terminology & Soil Science. Andy Spetch

What s in Your Media? Analysis of media components for micronutrient content

Advancing the power of SPE. Intelligent Automated Solid Phase Extraction. SmartPrep Brochure

Soil Test Report. HOME GARDEN VEGETABLE GARDEN Analysis Results

Know Your Soil Getting the Dirt on Your Dirt FWAA. Dr. Steve Petrie Director of Agronomic Services

Sunlight. Chlorophyll

plants the total amount of input materials was 6,7 million tons input and therefore the average throughout per plant nearly tons per year.

Process and Air Monitoring. Online GC systems for continuous monitoring of organic compounds in air and gaseous samples

Auto SPE-06Plus Solid Phase Extraction System. Reeko Instrument USA

Soil Quality / Understanding Soil Health what are we missing?

LISA Tallinna Vesi AS akrediteerimistunnistusele nr L065 ANNEX to the accreditation certificate No L065 of Tallinn Water Ltd

Soil Management Site Selection, Soil Fertility. Warren Roberts George Kuepper

CENTRAL TESTING LABORATORY CATALOG

TECHNICAL NOTE. Response Factors for Flame Ionization Detector Operation FLAME IONIZATION DETECTOR OPERATION BASICS

PARTS CLEANING AND DEGREASING

PURITY GRADES OF LAB REAGENTS

GUIDELINES FOR DESCRIBING THE ACCREDITATION SCOPES OF TESTING LABORATORIES

Refrigeration air dryer

GEOL 408/508 INTRODUCTORY SOILS

Effect on Soil Quality and Plants on Utilization of Domestic and paper mill sludge in Farm Lands

For demanding applications in life sciences and labs, and as supplier to analysers, autoclaves, glassware washers.

Effect of Soil Amendment with Dry and Wet Distillers Grains on Growth of Canola and Soil Properties

Class 3: Soil Sampling and Testing. Chris Thoreau

Learning Objectives. C. Owen Plank

Chapter 2.2. Basic Soil-Plant Interactions. learning objectives

Rootstocks are the foundation of a healthy and productive

Developing and Implementing a Fertilizer Program. Marc van Iersel. mixed with substrate components before planting

SOIL SAMPLING AND ANALYSIS

Green Roof Benefits. Green Roof Media Selection for the Minimization of Pollutant Loadings in Roof Runoff

150 & 200 RT MG-SERIES GAS FIRED DOUBLE-EFFECT EFFECT ABSORPTION CHILLER-HEATER

Schedule of Accreditation issued by United Kingdom Accreditation Service High Street, Feltham, Middlesex, TW13 4UN, UK

FERN MULTIPLICATION KIT

Advancing the power of SPE. Intelligent Automated Solid Phase Extraction. SmartPrep Brochure

Thermo Scientific Dionex AutoTrace 280 SPE Instrument. Automate Large-Volume. Solid-Phase Extractions

NUTRIENT MANAGEMENT. PHOSPHORUS (P) is an essential element

The Effect of ph from Simulated Acid Rain on Multi- Element Contents of Leaves, Stems and Roots of the Crops

Waspmote Plug & Sense! Quick Overview

Bio Fertilizer: A Promising Tool for Sustainable Farming

Water Quality Report

Effect of Inoculation with VAM Fungi on Macro Nutrient Status of Soil of Tagetes erecta L.

Table of Contents. Automated SPE Systems. Applications. Drinking water. Waste Water. Page. Page. Page. 2 EconoTrace tm 5 TurboTrace tm 8 NanoTrace tm

Land, then, is not merely soil; it is a fountain of energy flowing through a circuit of soils, plants, and animals.

B. Land capability subclass - DELETED Determine Land Capability Subclass according to the following rules. Mark all subclasses that apply.

Final Report Project Number: 08CA31673 File Number: IN 15941

SOIL TEST HANDBOOK FOR GEORGIA

INDIAN INSTITUTE OF SCIENCE EDUCATION AND RESEARCH PUNE

Transcription:

OBSEG METOD S FLEKSIBILNIM OBSEGOM AKREDITACIJE Center za kemijske analize živil, vod in drugih vzorcev okolja Oddelek za kemijske analize živil, vod in drugih vzorcev okolja, Gosposvetska ulica 12, 4000 Kranj Tabela / Table 1 Tip obsega: fleksibilni (možnost uvajanja manjših sprememb metode) / Type of scope: flexible (possibility of implementing minor s of the method) Področja preskušanja glede na vrsto preskušanca: okolje in vzorci iz okolja (, odpadki) / Testing fields with reference to the type of test item: environment and samples from the environment (, s) nestandardne preskusne metode Reference to standard or non-standard metode in morebitne navezave na druge standarde ali metode Title of standard or non-standard preskušanja (kjer je to Range of testing; Uncertainty of the result of testing (where relevant) 1. ND-IV-NLZOH-OKAKR-OV-045A izdaja 11 version 11 interna metoda in-house method Določanje mineralnih olj z ekstrakcijo v tetrakloroetilen in FTIR spektrometrijo Determination of mineral oils with extraction in tetrachloroethylen and FTIR spectrometry (0,1 500) mg/l odpadne 2. ND-IV-NLZOH-OKAKR-OV-054A izdaja 9 version 9 interna metoda in-house method Kakovost - Določevanje polarnih organskih topil Water quality Determination of polar organic solvents (5 100) mg/l metanol etanol (2 100) mg/l aceton acetonitril 1-propanol metil-etil-keton etilacetat tetrahidrofuran butanol odpadne Oddelek za kemijske analize živil, vod in drugih vzorcev okolja, Prvomajska ulica 1, 2000 Maribor Tabela / Table 2 Tip obsega: fleksibilni (možnost uvajanja manjših sprememb metode / Type of scope: flexible (possibility of implementing minor s of the method Področja preskušanja glede na vrsto preskušanca: okolje in vzorci iz okolja (, odpadki) / Testing fields with reference to the type of test item: environment and samples from the environment (, s) nestandardne preskusne metode metode in morebitne navezave na druge standarde ali metode Title of standard or non-standard Range of testing; Uncertainty of the result of testing (where relevant) OBR-II-NLZOH-K-42 1.izdaja Velja od: 2.7.2018 Stran: 1 od 1

Tip obsega: fleksibilni (možnost uvajanja manjših sprememb metode / Type of scope: flexible (possibility of implementing minor s of the method Področja preskušanja glede na vrsto preskušanca: okolje in vzorci iz okolja (, odpadki) / Testing fields with reference to the type of test item: environment and samples from the environment (, s) nestandardne preskusne metode metode in morebitne navezave na druge standarde ali metode Title of standard or non-standard Range of testing; Uncertainty of the result of testing (where relevant) 3. DIN 38407-35:2010 modificiran Nemške standardne metode za preiskavo, odpadne in usedlin-skupaj določljive skupine spojin (skupina F) 35.del: Določanje izbranih fenoksialkankarbonskih kislin in drugih kislinskih sredstev za zaščito rastlin z metodo HPLC in MS detekcijo Deutsche Einheitsverfahren zur Wasser-, Abwasser und Schlammuntersuchung Gemeinsam erfassbare Stoffgruppen (Gruppe F) Teil 35: Bestimmung ausgewählter Phenoxyalkancarbonsäuren und waiterer acider Pflanzenschutzmittelwirkstoffe-Verfahren mittels Hochleistungs- Flüssigkeitschromatographie und massespektrometrische Detektion (HPLC- MS/MS) (F 35) (0,02 1,0) µg/l dikamba MCPP MCPA 2,4-D silveks MCPB 2,4,5-T 2,4-DP 2,4-DB bromoksinil bentazon joksinil mezotrion metolaklor-esa metolaklor-oxa pitna, površinske surface 4. ISO 9562:2004 Kakovost Določanje adsorbljivih organsko vezanih halogenskih spojin (AOX) Water quality Determination of adsorbable organic halogens (4 300) µg/l surface 17.02.2012 (20 1000) µg/l odpadne 5. ISO 11423-1:1997 Kakovost Določevanje benzena in nekaterih derivatov 1. del: Plinska kromatografska metoda s tehniko»head space«water quality Determination of benzene and some derivatives Part 1: Head-space gas chromatographic method (0,6 400) µg/l benzen (1 700) µg/l toluen m, p-ksilen o-ksilen izopropilbenzen 1,3,5-trimetilbenzen 1,2,4-trimetilbenzen etilbenzen stiren surface 17.02.2012 (20 9000) µg/l benzen odpadne (20 18000) µg/l toluen m,p-ksilen o-ksilen izopropilbenzen 1,3,5-trimetilbenzen 1,2,4-trimetilbenzen etilbenzen stiren OBR-II-NLZOH-K-42 1.izdaja Velja od: 2.7.2018 Stran: 2 od 2

Tip obsega: fleksibilni (možnost uvajanja manjših sprememb metode / Type of scope: flexible (possibility of implementing minor s of the method Področja preskušanja glede na vrsto preskušanca: okolje in vzorci iz okolja (, odpadki) / Testing fields with reference to the type of test item: environment and samples from the environment (, s) nestandardne preskusne metode metode in morebitne navezave na druge standarde ali metode Title of standard or non-standard Range of testing; Uncertainty of the result of testing (where relevant) 6. ND-IV-NLZOH-OKAMB-34 izdaja 10 interna metoda in-house method Določanje nekaterih organodušikovih in organofosfornih pesticidov v vodi z metodo plinske kromatografije z masno selektivnim detektorjem po ekstrakciji na trdni fazi interna metoda Determination of selected organonitrogen and organophosphorous pesticides in water by gas chromatography and mas spectrometry after solid phase extraction in-house method (0,05 10) µg/l acetoklor alaklor ametrin atrazin bromopropilat cianazin ciprodinil desizopropil atrazin desetil atrazin desetil-terbutilazin diazinon diklobenil 2,6-diklorobenzamid dimetenamid dimetoat endosulfan-alfa endosulfan-beta endosulfan sulfat 2-etil-6-metil-2-kloro acetanilid fludioksinil flufenacet flurpkloridon heksazinon krezoksin metil klorfenvinfos kloropirifos-metil kloropirifos-etil malation metalaksil metazaklor metolaklor napropamid orbenkarb paration-etil paration-metil pendimetalin penkonazol pirimikarb prometrin propazin prosimidon sebutilazin sekbumeton simazin terbutilazin terbutrin terbumeton tetradifon tetrakonazol triadimefon vinklozolin površinske surface OBR-II-NLZOH-K-42 1.izdaja Velja od: 2.7.2018 Stran: 3 od 3

Tip obsega: fleksibilni (možnost uvajanja manjših sprememb metode / Type of scope: flexible (possibility of implementing minor s of the method Področja preskušanja glede na vrsto preskušanca: okolje in vzorci iz okolja (, odpadki) / Testing fields with reference to the type of test item: environment and samples from the environment (, s) nestandardne preskusne metode metode in morebitne navezave na druge standarde ali metode Title of standard or non-standard Range of testing; Uncertainty of the result of testing (where relevant) 7. ISO 10301:1997 poglavje 3 chapter 3 Kakovost Določevanje nekaterih lahkohlapnih halogeniranih ogljikovodikov Metoda plinske kromatografije Poglavje 3: Plinska kromatografska metoda s tehniko»head space«water quality Determination of highly volatile halogenated hydrocarbons Gas chromatographic methods Chapter 3: Static head space method and analysis by GC v µg/l: 1,1-dikloroetilen: (1 700) trans-1,2-dikloroetilen: (1 600) triklorometan: (0,5 300) 1,1,1-trikloroetan: (0,5 310) tetraklorometan: (0,2 70) 1,2-dikloroetan: (1 700) 1,1,2-trikloroetilen: (0,4 300) 1,1,2,2-tetrakloroetilen: (0,3 150) bromodiklorometan: (0,5 350) 1,1,2-trikloroetan: (0,5 350) klorodibromometan: (0,5 350) tribromometan: (0,5 300) 1,1-dikloroetan: (1,0 600) cis-1,2-dikloroetilen: (1,0 750) 1,3,5-triklorobenzen: (0,3 150) 1,2,4-triklorobenzen: (0,3 250) 1,2,3-triklorobenzen: (0,3 200) HCBD: (0,3 200) HCE: (0,3 150) surface 17.02.2012 OBR-II-NLZOH-K-42 1.izdaja Velja od: 2.7.2018 Stran: 4 od 4

Tip obsega: fleksibilni (možnost uvajanja manjših sprememb metode / Type of scope: flexible (possibility of implementing minor s of the method Področja preskušanja glede na vrsto preskušanca: okolje in vzorci iz okolja (, odpadki) / Testing fields with reference to the type of test item: environment and samples from the environment (, s) nestandardne preskusne metode metode in morebitne navezave na druge standarde ali metode Title of standard or non-standard Range of testing; Uncertainty of the result of testing (where relevant) 8. ISO 10301:1997 poglavje 3 chapter 3 Kakovost Določevanje nekaterih lahkohlapnih halogeniranih ogljikovodikov Metoda plinske kromatografije Poglavje 3: Plinska kromatografska metoda s tehniko»head space«water quality Determination of highly volatile halogenated hydrocarbons Gas chromatographic methods Chapter 3: Static head space method and analysis by GC v µg/l: 1,1-dikloroetilen: (10 18000) trans-1,2-dikloroetilen: (10 15000) triklorometan: (5 8000) 1,1,1-trikloroetan: (5 8000) tetraklorometan: (5 1800) 1,2-dikloroetan: (10 17000) 1,1,2-trikloroetilen: (5 7000) 1,1,2,2-tetrakloroetilen: (5 3500) bromodiklorometan: (5 9000) 1,1,2-trikloroetan: (5 9000) klorodibromometan: (5 9000) tribromometan: (5 7500) 1,1-dikloroetan: (10 14000) cis-1,2-dikloroetilen: (10 19000) 1,3,5-triklorobenzen: (5 4000) 1,2,4-triklorobenzen: (5 6000) 1,2,3-triklorobenzen: (5 4000) HCBD: (5 6000) HCE: (5 5000) odpadne v µg/l Cl: 1,1-dikloroetilen: (7 13000) trans-1,2-dikloroetilen: (7 11000) triklorometan: (4 7100) 1,1,1-trikloroetan: (4 6300) tetraklorometan: (5 1600) 1,2-dikloroetan: (4 12000) 1,1,2-trikloroetilen: (4 5600) 1,1,2,2-tetrakloroetilen: ( 4 3000) bromodiklorometan: (2 3900) 1,1,2-trikloroetan: (4 7200) klorodibromometan: (1 1500) 1,1-dikloroetan: OBR-II-NLZOH-K-42 1.izdaja Velja od: 2.7.2018 Stran: 5 od 5

Tip obsega: fleksibilni (možnost uvajanja manjših sprememb metode / Type of scope: flexible (possibility of implementing minor s of the method Področja preskušanja glede na vrsto preskušanca: okolje in vzorci iz okolja (, odpadki) / Testing fields with reference to the type of test item: environment and samples from the environment (, s) nestandardne preskusne metode metode in morebitne navezave na druge standarde ali metode Title of standard or non-standard Range of testing; Uncertainty of the result of testing (where relevant) (7 10000) cis-1,2-dikloroetilen: (7 14000) 1,3,5-triklorobenzen: (3 2300) 1,2,4-triklorobenzen: (3 3500) 1,2,3-triklorobenzen: (3 2300) HCBD: (4 4900) HCE: (4 4500) triklorometan: (1 2000) tribromometan: (1 1900) bromodiklorometan: (1 1100) dibromoklorometan: (1 1100) bazenske swimming pool 9. ISO 7887:2011 poglavje B chapter B Kakovost Pregled in določevanje barve Water quality Examination and determination of colour Določanje prave barve z optičnim instrumentom 436nm (0,1-100)m -1 525nm (0,2-50)m -1 620nm (0,1-25)m -1 odpadne surface, 10. ISO 7027-1:2016 Kakovost Ugotavljanje motnosti Water quality Determination of turbidity (0,1 30) NTU/FNU bazenske surface, swimming pool 26.09.2016 11. EN ISO 8467:1995 Kakovost Določanje permanganatnega indeksa Water quality Determination of permanganate index (2 25) mg/l KMnO 4 (0,5 5) mg/l O 2 odpadne surface, 17.02.2012 OBR-II-NLZOH-K-42 1.izdaja Velja od: 2.7.2018 Stran: 6 od 6

Tip obsega: fleksibilni (možnost uvajanja manjših sprememb metode / Type of scope: flexible (possibility of implementing minor s of the method Področja preskušanja glede na vrsto preskušanca: okolje in vzorci iz okolja (, odpadki) / Testing fields with reference to the type of test item: environment and samples from the environment (, s) nestandardne preskusne metode metode in morebitne navezave na druge standarde ali metode Title of standard or non-standard Range of testing; Uncertainty of the result of testing (where relevant) 12. ISO 8245:1999 Kakovost Smernice za določevanje celotnega organskega ogljika (TOC) Water quality Guidelines for the determination of total organic carbon (TOC) and dissolved organic carbon (DOC) Priprava izlužka po SIST EN 12457-4: 2004 (0,5 3) mg/l (2 2000) mg/l surface odpadne 17.02.2012 (5 20000) mg/kg s.s. odpadki (izlužek) (leachate) 13. ISO 11083:1994 Kakovost Določanje kroma (VI) Spektrofotometrijska metoda z uporabo 1,5-difenilkarbazida Water quality Determination of chromium (VI) Spectrometric metod using 1,5 diphenylcarbazide 14. ISO 6439:1990 Kakovost Določanje fenolnega indeksa Spektrofotometrijska metoda s 4- aminoantipirinom s predhodno destilacijo Water quality Determination of phenol index 4 aminoantipyrine spectrometric method after distillation (0,01 0,5) mg/l odpadne surface, (10 2000) µg/l odpadne surface, 17.02.2012 17.02.2012 15. ISO 6878:2004 poglavji 4, 8 chapters 4, 8 Kakovost Določevanje fosforja Spektrofotometrijska metoda z amonijevim molibdatom Poglavje 4: Določevanje ortofosfata Poglavje 8: Določevanje skupnega fosforja po kislinskem razklopu Water quality Spectrometric determination of phosphorus using ammonium molybdate Chapter 4: Determination of ortophosphate Chapter 8: Determinaton of total phosphorus after nitric acid sulfuric acid digestion o-fosfat: (0,005 5) mg/l PO 4 3- -P (0,015-15) mg/l PO 4 3- P-celoten: (0,005 100)mg/L PO 4 3- -P (0,015-306) mg/l PO 4 3- P-celoten: (0,015-100) mg/l PO 4 3- -P (0,15-306) mg/l PO 4 3- površinske surface odpadne 16. ISO 7150-1:1984 Kakovost Določanje amonija 1. del: Ročna spektrofotometrijska metoda Water quality Determination of ammonium Part 1: Manual spectrometric method (0,010 1,0)mg/L NH 4 + - N (0,013-1,3)mg/L NH 4 + surface OBR-II-NLZOH-K-42 1.izdaja Velja od: 2.7.2018 Stran: 7 od 7

Tip obsega: fleksibilni (možnost uvajanja manjših sprememb metode / Type of scope: flexible (possibility of implementing minor s of the method Področja preskušanja glede na vrsto preskušanca: okolje in vzorci iz okolja (, odpadki) / Testing fields with reference to the type of test item: environment and samples from the environment (, s) nestandardne preskusne metode metode in morebitne navezave na druge standarde ali metode Title of standard or non-standard 17. ISO 5664:1984 Kakovost Določanje amonija Destilacijska in titracijska metoda Water quality Determination of ammonium Distillation and titration method Range of testing; Uncertainty of the result of testing (where relevant) (1 3000) mg/l NH 4 + - N odpadne 17.02.2012 18. ISO 10304-1:2007 Kakovost Določevanje raztopljenih anionov z ionsko kromatografijo 1. del: Določevanje klorida, nitrata in sulfata Water quality Determination of dissolved anions by liquid chromatography of ions Part 1: Determination of bromide, chloride, fluoride, nitrate, nitrite, ortophosphate, and sulfate v mg/l: Cl - : (0,5 200) SO 4 2- : (1,0 3000) NO 3 - - N: (0,5 30) NO 3 - : (2,2 133) mineralne surface, mineral Priprava izlužka po SIST EN 12457-4: 2004 v mg/l: Cl - : (0,5 200) SO 4 2- : (1,0 3000) NO 3 - - N : (0,5 30) NO 3 - : (2,2 133) odpadne Cl - : (5 20000) mg/kg s.s. SO 4 2- : (10 3000) mg/kg s.s odpadki (izlužek) (leachate) 19. ISO 10304-3:1997 Kakovost Določevanje raztopljenih anionov z ionsko kromatografijo 3. del: Določevanje sulfita Water quality Determination of dissolved anions by liquid chromatography of ions Part 3: Determination of chromate, iodide, sulfite, thiocyanate and thiosulfate sulfit: (0,5 50) mg/l odpadne surface, 17.02.2012 20. ISO 6777:1984 Kakovost Določanje nitrita Molekularna absorpcijska spektrometrijska metoda Water quality Determination of nitrite Molecular absorption spectrometric method (0,002 1,0) mg/l NO 2 - -N (0,007-3,29) mg/l NO 2 - odpadne surface, 21. ISO 11923:1997 Kakovost Določevanje suspendiranih snovi s filtracijo skozi filter iz steklenih vlaken Water quality Determination of suspended solids by filtration through glassfibre filters (2 300) mg/l odpadne surface, 17.02.2012 OBR-II-NLZOH-K-42 1.izdaja Velja od: 2.7.2018 Stran: 8 od 8

Tip obsega: fleksibilni (možnost uvajanja manjših sprememb metode / Type of scope: flexible (possibility of implementing minor s of the method Področja preskušanja glede na vrsto preskušanca: okolje in vzorci iz okolja (, odpadki) / Testing fields with reference to the type of test item: environment and samples from the environment (, s) nestandardne preskusne metode metode in morebitne navezave na druge standarde ali metode Title of standard or non-standard Range of testing; Uncertainty of the result of testing (where relevant) 22. SM 4500-NO 3B: 2017 Določanje nitrata z UV spektrofotometrijo Nitrogen (nitrate) ultraviolet spectrophotometric screening method (0,5 20) mg/l NO 3 - - N (2,2 88) mg/l NO 3 - bazenske surface, swimming pool 01.02.2018 23. ISO 6060:1989 Kakovost Določanje kemijske potrebe po kisiku Water quality Determination of chemical oxygen demand O 2 : (30 30000) mg/l odpadne 17.02.2012 24. EN 1899-1:1998 Kakovost Določevanje biokemijske potrebe po kisiku po n- dneh (BPKn) 1. del: Metoda razredčevanja in cepljenja z dodatkom aliltiosečnine Water quality Determination of biochemical oxygen demand after n- days (BODn) Part 1: Dilution and seeding method with allylthiourea addition O 2 : (3 5000) mg/l odpadne surface, 25. EN 1899-2:1998 Kakovost Določevanje biokemijske potrebe po kisiku po n dneh (BODn) 2. del: Metoda za nerazredčene vzorce Water analysis-determination of biochemical oxygen demand after n days (BODn) Part 2: Method for undiluted samples O 2 : (0,5 6,0) mg/l površinske surface 17.02.2012 26. EN ISO 15680:2003 Kakovost Določevanje monocikličnih aromatskih ogljikovodikov in posameznih kloriranih spojin s plinsko kromatografijo z uporabo tehnike purge and trap in toplotno desorpcijo Water quality Gas-chromatographic determination of a number of monocyclic aromatic hydrocarbons, naphthalene and several chlorinated compounds using purgeand-trap and thermal desorption (0,1 200) g/l trans-1,2-dikloroeten 1,1-dikloroetan cis-1,2-dikloroten bromoklorometan triklorometan tetrakloroeten 1,1,2-trikloroeten 1,3-diklorobenzen 1,4-diklorobenzen 1,2-diklorobenzen 1,2,4-triklorobenzen 1,2,3-triklorobenzen 1,3,5-triklorobenzen bazenske, mineralne surface,swim ming pool, mineral 17.02.2012 (0,2 200) g/l 1,2-dikloroetan 1,1,1-trikloroetan 1,1-dikloropropen tetraklorometan benzen dibromometan 1,2-dikloropropan bromodiklorometan 1,1,2-trikloroetan toluen dibromoklorometan 1,2-dibromoetan klorobenzen OBR-II-NLZOH-K-42 1.izdaja Velja od: 2.7.2018 Stran: 9 od 9

Tip obsega: fleksibilni (možnost uvajanja manjših sprememb metode / Type of scope: flexible (possibility of implementing minor s of the method Področja preskušanja glede na vrsto preskušanca: okolje in vzorci iz okolja (, odpadki) / Testing fields with reference to the type of test item: environment and samples from the environment (, s) nestandardne preskusne metode metode in morebitne navezave na druge standarde ali metode Title of standard or non-standard Range of testing; Uncertainty of the result of testing (where relevant) etilbenzen tribromometan stiren o-ksilen 1,2,3-trikloropropan izopropilbenzen bromobenzen n-propilbenzen 2-klorotoluen 4-klorotoluen 1,3,5-trimetilbenzen ter-butilbenzen 1,2,4-trimetilbenzen sec-butilbenzen p-izopropiltoluen n-butilbenzen heksaklorobutadien heksakloroetan (0,4 200) g/l m,p-ksilen 27. ISO 10530:2002 Kakovost Določanje raztopljenega sulfida Fotometrijska metoda z uporabo metilen modrega Water quality Determination of dissolved sulfide Photometric method using methylene blue (0,5 200) g/l 1,1-dikloroeten tetrabutilmtileter cis-1,3-dikloropropen trans-1,3- dikloropropen 1,3- dikloropropan (2 200) g/l diklorometan (0,05 20) mg/l odpadne surface, 17.02.2012 28. ISO 5663:1984 modificiran Kakovost Določanje dušika po Kjeldahlu Metoda po mineralizaciji s selenom Water quality Determination of Kjeldahl nitrogen Method after mineralization with selenium (0,5 3000) mg/l N odpadne surface, 17.02.2012 29. SIST EN ISO 12846:2012 brez poglavja 6 without chapter 6 Kakovost Določevanje živega srebra - Metoda atomske absorpcijske spektrometrije (AAS) s predkoncentracijo ali brez nje Water quality Determination of mercury - Method using atomic absorption spectrometry with and without enrichment (ISO 12846:2012) (0,1 10) µg/l mineralne mineral OBR-II-NLZOH-K-42 1.izdaja Velja od: 2.7.2018 Stran: 10 od 10

Tip obsega: fleksibilni (možnost uvajanja manjših sprememb metode / Type of scope: flexible (possibility of implementing minor s of the method Področja preskušanja glede na vrsto preskušanca: okolje in vzorci iz okolja (, odpadki) / Testing fields with reference to the type of test item: environment and samples from the environment (, s) nestandardne preskusne metode metode in morebitne navezave na druge standarde ali metode Title of standard or non-standard Range of testing; Uncertainty of the result of testing (where relevant) 30. SIST EN ISO 12846:2012 modificiran v poglavju 7.4 in chapter 7.4 brez poglavja 6 without chapter 6 Kakovost Določevanje živega srebra - Metoda atomske absorpcijske spektrometrije (AAS) s predkoncentracijo ali brez nje Water quality Determination of mercury - Method using atomic absorption spectrometry with and without enrichment (0,20 50) µg/l (1 150) µg /kg s.s. odpadne odpadki (izlužek) (leachate) 22.06.2016 Razklop preskusnega vzorca odpadnih vod po SIST EN ISO 15587-1: 2003 Priprava izlužka po SIST EN 12457-4: 2004 31. SIST EN ISO 18856:2005 Modificiran v točki 7 in 8.2 Modified in point 7 and 8.2 Kakovost Določevanje izbranih ftalatov s plinsko kromatografijo/masno spektrometrijo (ISO 18856:2004) Water quality Determination of selected phthalates using gas chromatography/mass spectrometry (ISO 18856:2004) (0,1-100) µg/l dimetil ftalat dietil ftalat, dibutil ftalat butil benzil ftalat di(2-etilheksil)ftalat, di(n-oktil)ftalat tributilfosfat trikloroetilfosfat trikloropropilfosfat izvirske, mineralne, potable ground, surface, spring, mineral 32. ISO 10359-1:1992 Kakovost Določanje fluorida 1. del: Elektrokemijska metoda z iono selektivno elektrodo za pitne in malo onesnažene Water quality Determination of fluoride Part 1: Electrochemical probe method for potable and lightly polluted water (0,2 10) mg/l mineralne surface, mineral 17.02.2012 Priprava izlužka po SIST EN 12457-4: 2004 (0,2 2000) mg/l (2 100) mg/kg s.s. odpadne odpadki (izlužek) (leachate) 33. EN ISO 9377-2:2001 Kakovost Določanje indeksa mineralnih olj 2. del: Metoda z uporabo ekstrakcije s topilom in plinske kromatografije Water quality Determination of hydrocarbon oil index Part 2: Method using solvent extraction and gas chromatography (0,020 150) mg/l (0,2 10000) mg/l površinske surface odpadne 17.02.2012 34. EN ISO 11369:1997 modificiran Kakovost Določanje izbranih sredstev za zaščito rastlin Metoda z uporabo tekočinske kromatografije visoke ločljivosti (ISO 11369:1997) Wasserbeschaffenheit Bestimmung ausgewählter Pflanzenbehandlungsmittel on-line metoksuron: (0,02-10) µg/l diklorfos: (0,05-1,0) µg/l OBR-II-NLZOH-K-42 1.izdaja Velja od: 2.7.2018 Stran: 11 od 11 površinske

Tip obsega: fleksibilni (možnost uvajanja manjših sprememb metode / Type of scope: flexible (possibility of implementing minor s of the method Področja preskušanja glede na vrsto preskušanca: okolje in vzorci iz okolja (, odpadki) / Testing fields with reference to the type of test item: environment and samples from the environment (, s) nestandardne preskusne metode metode in morebitne navezave na druge standarde ali metode Title of standard or non-standard Range of testing; Uncertainty of the result of testing (where relevant) Verfahren mit der Hochauflösungs- Flüssigkeitschromatographie mit UV- Detektion nach Fest-Flüssig-Extraktion (ISO 11369:1997) (0,01 5,0) µg/l alaklor ametrin atrazin azinfos-etil azinfos-metil azoksistrobin bromacil buturon cianazin ciprodinil desetilatrazin desetilterbutilazin desizopropilatrazin diazinon difenkonazol dimetenamid: dimetoat diuron fention fenuron flufenacet heksazinon imidakloprid izoproturon klorbromuron klorfenvinfos klortoluron linuron malation metalaksil metamitron metazaklor metobromuron metolaklor metribuzin mevinfos monolinuron monuron napropamid neburon pendimetalin penkonazol pirimikarb prometon prometrin propazin propikonazol sebutilazin simazin simetrin terbumeton terbutilazin terbutrin tetrakonazol triadimefon trifloksistrobin surface OBR-II-NLZOH-K-42 1.izdaja Velja od: 2.7.2018 Stran: 12 od 12

Tip obsega: fleksibilni (možnost uvajanja manjših sprememb metode / Type of scope: flexible (possibility of implementing minor s of the method Področja preskušanja glede na vrsto preskušanca: okolje in vzorci iz okolja (, odpadki) / Testing fields with reference to the type of test item: environment and samples from the environment (, s) nestandardne preskusne metode metode in morebitne navezave na druge standarde ali metode Title of standard or non-standard Range of testing; Uncertainty of the result of testing (where relevant) 35. ISO 17294-2:2016 Kakovost - Uporaba masne spektrometrije z induktivno sklopljeno plazmo (ICP/MS) - 2. del: Določevanje izbranih elementov, vključno z izotopi urana Water quality Application of inductively coupled plasma mass spectrometry (ICP- MS) Part 2: Determination of selected elements including uranium isotopes v g/l: Al (10 100) As (1 100) Sb (1 100) Cu (1 100) Ba (10 100) Zn (10 1000) Cd (0,1 100) Co (1 100) Sn (1 100) Cr (1 100) Ni (1 100) Ag (1 100) Pb (1 100) B (10 1000) V (1 100) Mn (1 1000) Be (1 10) Mo (1 100) Se (1 10) površinske surface 26.09.2016 v mg/l: Na (0,5 2000) K (0,2 100) Ca (1,0-500) Mg (0,5-1000) površinske, mineralne surface, mineral OBR-II-NLZOH-K-42 1.izdaja Velja od: 2.7.2018 Stran: 13 od 13

Tip obsega: fleksibilni (možnost uvajanja manjših sprememb metode / Type of scope: flexible (possibility of implementing minor s of the method Področja preskušanja glede na vrsto preskušanca: okolje in vzorci iz okolja (, odpadki) / Testing fields with reference to the type of test item: environment and samples from the environment (, s) nestandardne preskusne metode metode in morebitne navezave na druge standarde ali metode Title of standard or non-standard Range of testing; Uncertainty of the result of testing (where relevant) 36. ISO 17294-2:2016 Kakovost - Uporaba masne spektrometrije z induktivno sklopljeno plazmo (ICP/MS) - 2. del: Določevanje izbranih elementov, vključno z izotopi urana Water quality Application of inductively coupled plasma mass spectrometry (ICP- MS) Part 2: Determination of selected elements including uranium isotopes Razklop preskusnega vzorca odpadnih vod po SIST EN ISO 15587-1: 2003 Priprava izlužka po SIST EN 12457-4: 2004 v mg/l: Ag (0,005 1,0) Al (0,1 10) As (0,010 1,0) B (0,10 50) Ba (0,10 10) Be (0,001 10) Cd (0,001 1,0) Co (0,010 5,0) Cr (0,010 10) Cu (0,005 10) Mn (0,10 10) Mo (0,010 10) Ni (0,010 10 Pb (0,005 5,0) Sb (0,010 1,0) Se (0,010 10) Sn (0,10 10) Tl (0,001 1,0) V (0,050 5,0) Zn (0,10 100) odpadne v mg/kg s.s.: As (0,05 0,5) Ba (1,0 100) Cd (0,001 0,2) Cr (0,05 100) Cu (0,10 500) Ni (0,01 500) Mo (0,05 5,0) Pb (0,05 100) Sb (0,01 0,5) Se (0,01 5,0) Zn (0,5 100) odpadki (izlužek) (leachate) 37. DIN 38406-E32-1: 2000 Nemške standardne metode za preiskavo, odpadne in usedlin Kationi (skupina E) 32. del: Določanje železa z atomsko absorpcijsko spektrometrijo Deutsche Einheitsverfahren zur Wasser-, Abwasser und Schlammuntersuchung Kationen (Gruppe E) Teil 32: Bestimmung von Eisen mittels Atomabsorptionsspektrometrie (E 32) samo plamenska AAS tehnika Razklop preskusnega vzorca odpadnih vod po SIST EN ISO 15587-1: 2003 (0,1 10) mg/l mineralne, bazenske, odpadne surface, mineral, swimming pool, 05.02.2015 OBR-II-NLZOH-K-42 1.izdaja Velja od: 2.7.2018 Stran: 14 od 14

Tip obsega: fleksibilni (možnost uvajanja manjših sprememb metode / Type of scope: flexible (possibility of implementing minor s of the method Področja preskušanja glede na vrsto preskušanca: okolje in vzorci iz okolja (, odpadki) / Testing fields with reference to the type of test item: environment and samples from the environment (, s) nestandardne preskusne metode metode in morebitne navezave na druge standarde ali metode Title of standard or non-standard Range of testing; Uncertainty of the result of testing (where relevant) 38. EN ISO 9963-1:1995 Kakovost Določanje alkalitete 1. del: Določanje celotne in sestavljene alkalitete Water quality Determination of alkalinity Part 1: Determination of total and composite alkalinity (0,1 30) mmol/l (6,0 1800) mg/l HCO 3 surface 39. DIN 38409-44:1992 modificiran Nemške standardne metode za preiskavo, odpadne in usedlin Skupni učinki vrste in količine snovi Določanje kemijske potrebe po kisiku v območju 5 do 50 mg/l (H 44) Deutsche Einheitsverfahren zur Wasser-, Abwasser- und Schlammuntersuchung- Summarische Wirkungs- und Stoffkenngrössen -Bestimmung des Chemischen Sauerstoffbedarfs (CSB) im Bereich 5 bis 50 mg/l (H 44) O 2: (5 30) mg/l površinske surface 17.02.2012 40. ISO 6468:1996 modificiran Kakovost Določevanje nekaterih organoklornih insekticidov, polikloriranih bifenilov in klorobenzenov Plinska kromatografska metoda po tekočinski ekstrakciji Water quality Determination of certain organochlorine insecticides, polychlorinated biphenyls and chlorobenzenes Gas chromatographic method after liquid liquid extraction (0,005 0,10) g/l PCB 28 PCB 52 PCB 101 PCB 138 PCB 153 PCB 180 Pentaklorobenzen (0,003 0,10) µg/l α HCH (0,002 0,10) µg/l HCB (0,002 0,10) µg/l β HCH (0,004 0,10) µg/l γ HCH (0,003 0,10) µg/l kvintozen (0,002 0,10) µg/l δ HCH (0,004 0,10) µg/l heptaklor (0,003 0,10) µg/l aldrin (0,003 0,10) µg/l isodrin (0,003 0,10) µg/l cis-heptaklorepoksid (0,003 0,10) µg/l trans-heptaklorepoksid (0,003 0,10) µg/l trans-klordan (0,003-0,10) µg/l o,p' DDE (0,004 0,10) µg/l endosulfan-1 (0,004 0,10) µg/l cis-klordan (0,002 0,10) µg/l p,p' DDE (0,004 0,10) µg/l dieldrin (0,004 0,10) µg/l površinske surface 17.02.2012 o,p' DDD (0,005 0,10) µg/l endrin (0,005 0,10) µg/l OBR-II-NLZOH-K-42 1.izdaja Velja od: 2.7.2018 Stran: 15 od 15

Tip obsega: fleksibilni (možnost uvajanja manjših sprememb metode / Type of scope: flexible (possibility of implementing minor s of the method Področja preskušanja glede na vrsto preskušanca: okolje in vzorci iz okolja (, odpadki) / Testing fields with reference to the type of test item: environment and samples from the environment (, s) nestandardne preskusne metode metode in morebitne navezave na druge standarde ali metode Title of standard or non-standard Range of testing; Uncertainty of the result of testing (where relevant) endosulfan-2 (0,004 0,10) µg/l p,p' DDD (0,004 0,10) µg/l o,p' DDT (0,005 0,10) µg/l endrin aldehid (0,004 0,10) µg/l endosulfan sulfat (0,005 0,10) µg/l p,p' DDT (0,005-0,10) µg/l o,p' metoksiklor (0,005 0,10) µg/l endrin keton (0,005 0,10) µg/l p,p' metoksiklor (0,005 0,10) µg/l mirex (0,004 0,10) µg/l 41. ISO 13358:1997 Kakovost Določanje lahko sprostljivega sulfida Water quality Determination of easily released sulfide (0,05 20,0) mg/l odpadne surface, 17.02.2012 42. ISO 6468:1996 modificiran Kakovost Določevanje nekaterih organoklornih insekticidov, polikloriranih bifenilov in klorobenzenov Plinska kromatografska metoda po tekočinski ekstrakciji Water quality Determination of certain organochlorine insecticides, polychlorinated biphenyls and chlorobenzenes Gas chromatographic method after liquid liquid extraction (0,010 1,0) g/l PCB 28 PCB 52 PCB 101 PCB 138 PCB 153 PCB 180 (0,010 1,0) g/l HCH HCB HCH HCH kvintozen heptaklor aldrin isodrin cis-heptaklor-epoksid trans-heptaklor-epoksid trans-klordan o,p' DDE cis-klordan p,p' DDE dieldrin o,p' DDD endrin p,p' DDD o,p' DDT p,p' DDT o,p' metoksiklor p,p' metoksiklor mirex odpadne 05.02.2015 OBR-II-NLZOH-K-42 1.izdaja Velja od: 2.7.2018 Stran: 16 od 16

Tip obsega: fleksibilni (možnost uvajanja manjših sprememb metode / Type of scope: flexible (possibility of implementing minor s of the method Področja preskušanja glede na vrsto preskušanca: okolje in vzorci iz okolja (, odpadki) / Testing fields with reference to the type of test item: environment and samples from the environment (, s) nestandardne preskusne metode metode in morebitne navezave na druge standarde ali metode Title of standard or non-standard Range of testing; Uncertainty of the result of testing (where relevant) 43. EN ISO 14911:1999 Kakovost Določanje raztopljenih ionov Na +, K +, Ca 2+ in Mg 2+ z ionsko kromatografijo Metoda za vodo in odpadno vodo Water quality Determination of dissolved ions Li +, Na +, Mn 2+, NH 4+, K +, Mn 2+, Ca 2+, Mg 2+, Sr 2+ and Ba 2+ using ion chromatography Method for water and water v mg/l: Na: (1 1500) K: (0,2 100) Ca: (2 500) Mg: (1 1300) odpadne, mineralne surface,, mineral 17.02.2012 44. DIN 38409-6:1986 Nemške standardne metode za preiskavo, odpadne in usedlin Skupni učinki vrste in količine snovi Trdota (H6) Deutsche Einheitsverfahren zur Wasser- Abwasser- und Schlammuntersuchung- Summarische Wirkungs- und Stoffkenngrössen-Härte eines Wassers (H6) (0,05 26) mmol/l (0,3 150) o N odpadne surface, Vsebnost Ca in Mg določena po EN ISO 14911 ali ISO 17294-2 Content of Ca and Mg determined according to EN ISO 14911 or ISO 17294-2 45. ISO 6059:1984 Kakovost Določanje vsote kalcija in magnezija Titrimetrična metoda z EDTA Water quality Determination of the sum of calcium and magnesium EDTA titrimetric method (0,05 26) mmol/l (0,3 150) o N površinske surface 22.06.2016 46. ISO 6058:1984 Kakovost Ugotavljanje vsebnosti kalcija Titrimetrična metoda z EDTA Water quality Determination of calcium content EDTA titrimetric method (0,05 12) mmol/l (2 500) mg/l površinske surface 17.02.2012 47. ISO 10523:2008 Kakovost Določanje ph Water quality Determination of ph Priprava izlužka po SIST EN 12457-4: 2004 2-12 odpadne surface, odpadki (izlužek) (leachate) OBR-II-NLZOH-K-42 1.izdaja Velja od: 2.7.2018 Stran: 17 od 17

Tip obsega: fleksibilni (možnost uvajanja manjših sprememb metode / Type of scope: flexible (possibility of implementing minor s of the method Področja preskušanja glede na vrsto preskušanca: okolje in vzorci iz okolja (, odpadki) / Testing fields with reference to the type of test item: environment and samples from the environment (, s) nestandardne preskusne metode metode in morebitne navezave na druge standarde ali metode Title of standard or non-standard Range of testing; Uncertainty of the result of testing (where relevant) 48. EN 27888:1993 Kakovost Določanje električne prevodnosti Water quality Determination of electrical conductivity Priprava izlužka po SIST EN 12457-4: 2004 (2 2000) µs/cm T=20 o C odpadne surface, 22.06.2016 (2 5000) µs/cm T=20 o C T=25 o C odpadki (izlužek) (leachate) 49. DIN 38409-H1-1:1987 Nemške standardne metode za preiskavo, odpadne in usedlin Skupni učinki vrste in količine snovi Določevanje celotnega trdnega ostanka po sušenju in trdnega ostanka filtrata po sušenju ter žarenju (H1) Deutsche Einheitsverfahren zur Wasser-, Abwasser- und Schlammuntersuchung- Summarische Wirkungs- und Stoffkenngrössen Bestimmung des Gesamttrockenrückstandes, des Filtrattrockenrückstandes und des Glührückstandes (H1) (10 10000) mg/l (100 10000) mg/l odpadne surface, mineralne, termalne mineral, thermal 17.02.2012 50. DIN 38409-H9-2:1980 Nemške standardne metode za preiskavo, odpadne in usedlin Skupni učinki vrste in količine snovi Določanje prostorninskega deleža usedljivih snovi v odpadni vodi Deutsche Einheitsverfahren zur Wasser-, Abwasser- und Schlammuntersuchung- Summarische Wirkungs- und Stoffkenngrössen Bestimmung des Volumenanteils der absetzbaren Stoffe im Wasser und Abwasser (0,1 100) ml/l odpadne 17.02.2012 51. ISO 17353:2004 Določanje izbranih organokositrovih spojin v vodi s plinsko kromatografijo Water quality Determination of selected organotin compounds Gas chromatographic method (0,05 1000) µg/l monobutilkositrove spojine dibutilkositrove spojine tributilkositrove spojine difenilkositrove spojine trifenilkositrove spojine odpadne surface, 17.02.2012 52. ISO 11732:2005 Kakovost Določanje amonijevega dušika s pretočno analizo (CFA) in spektrofotometrijsko detekcijo Water quality Determination of ammonium nitrogen by flow analysis (CFA and FIA) and spectrometric detection (0,010 2,0) mg/l NH 4 + - N (0,013 2,6) mg/l NH 4 + površinske surface OBR-II-NLZOH-K-42 1.izdaja Velja od: 2.7.2018 Stran: 18 od 18

Tip obsega: fleksibilni (možnost uvajanja manjših sprememb metode / Type of scope: flexible (possibility of implementing minor s of the method Področja preskušanja glede na vrsto preskušanca: okolje in vzorci iz okolja (, odpadki) / Testing fields with reference to the type of test item: environment and samples from the environment (, s) nestandardne preskusne metode metode in morebitne navezave na druge standarde ali metode Title of standard or non-standard Range of testing; Uncertainty of the result of testing (where relevant) 53. ISO 14402:1999 Kakovost Določevanje fenolnega indeksa s pretočno analizo (CFA) Water quality Determination of phenol index by flow analysis (FIA and CFA) fenolni indeks: (10 7000) μg/l odpadne surface, 17.02.2012 Priprava izlužka po SIST EN 12457-4: 2004 (0,1 70) mg/kg s.s. odpadki (izlužek) (leachate) 54. ISO 16265:2009 Kakovost Določevanje MBAS indeksa Metoda s pretočno analizo (CFA) Water quality Determination of the methylene blue active substances (MBAS) index Method using continuous flow analysis (CFA) MBAS (0,05 5,0) mg/l odpadne surface, 17.02.2012 55. ISO 15681-2:2003 Kakovost Določevanje ortofosfata s pretočno analizo (CFA) 2. del: Metoda s kontinuirno pretočno analizo (CFA) Water quality Determination of orthophosphate and total phosphorous contents by flow analysis (FIA and CFA) Part 2: Method by continuous flow analysis (CFA) (0,010 10) mg/l PO 4 3 -P (0,031-31) mg/l PO 4 3- odpadne surface, 56. EPA 1613B:1999 Določanje tetra do okta kloriranih dioksinov in furanov z metodo izotopskega redčenja HRGC/HRMS v vodi Determination of tetra- through octachlorinated dioxins and furans by isotope dilution HRGC/HRMS (0,001 1000) ng/l 2,3,7,8-TCDD 1,2,3,7,8-PeCDD 1,2,3,4,7,8-HxCDD 1,2,3,6,7,8-HxCDD 1,2,3,7,8,9-HxCDD 1,2,3,4,6,7,8-HpCD 1,2,3,4,5,6,7,8-OCDD 2,3,7,8-TCDF 1,2,3,7,8-PeCDF 2,3,4,7,8-PeCDF 1,2,3,4,7,8-HxCDF 1,2,3,6,7,8-HxCDF 1,2,3,7,8,9-HxCDF 2,3,4,6,7,8-HxCDF 1,2,3,4,6,7,8-HpCDF 1,2,3,4,7,8,9-HpCDF 1,2,3,4,5,6,7,8-OCDF odpadne surface, 17.02.2012 57. ISO 6703-1:1984 Kakovost Dočevanje cianida 1. del: Določevanje skupnega cianida Water quality Determination of cyanide Part 1: Determination of total cyanide (0,01 1,0) mg/l odpadne surface, 17.02.2012 OBR-II-NLZOH-K-42 1.izdaja Velja od: 2.7.2018 Stran: 19 od 19

Tip obsega: fleksibilni (možnost uvajanja manjših sprememb metode / Type of scope: flexible (possibility of implementing minor s of the method Področja preskušanja glede na vrsto preskušanca: okolje in vzorci iz okolja (, odpadki) / Testing fields with reference to the type of test item: environment and samples from the environment (, s) nestandardne preskusne metode metode in morebitne navezave na druge standarde ali metode Title of standard or non-standard Range of testing; Uncertainty of the result of testing (where relevant) 58. SIST ISO 6703-2:1996 brez poglavja 3 without chapter 3 Kakovost Določanje cianida 2. del: Določanje prostega cianida Water quality Determination of cyanide Part 2: Determination of easily liberatable cyanide (0,01 1,0) mg/l odpadne 17.02.2012 59. SIST ISO 11349: 2011 Kakovost Določevanje težko hlapnih lipofilnih snovi Gravimetrijska metoda Water quality Determination of lowvolability liphophilic substances-gravimetric method (5 300) mg/l odpadne surface, 19.12.2013 60. ND-IV-NLZOH-OKAMB-14 izdaja 8 interna metoda in-house method Določanje skupnega dušika v vodi Determination of total nitrogen in water (3 3000) mg/l N odpadne surface, 23.05.2017 61. ISO 13395:1996 Kakovost določanje nitritnega dušika s pretočno analizo (CFA in FIA) in spektrometrično detekcijo Water quality Determination of nitrite nitrogen and nitrate nitrogen and the sum of both by flow injection analysis (CFA and FIA) and spectrometric detection (0,002 0,5)mg/L NO 2 - -N (0,006-1,6) mg/l NO 2 - odpadne surface, 22.06.2016 62. ISO 17993:2003 modificiran Določanje izbranih policikličnih aromatskih ogljikovodikov vodi s HPLC s fluorescenčnim detektorjem po ekstrakciji tekoče-tekoče Water quality Determination of 15 polycyclic aromatic hydrocarbons (PAH) in water by HPLC with fluorescence setection after liquid-liquid extraction (0,004 0,1) µg/l fenantren antracen fluoranten piren bezo(a)antracen krizen benzo(b)fluoranten benzo(k)fluoranten benzo(a)piren dibenzo(a,h)antracen benzo(g,h,i)perilen površinske surface 17.02.2012 OBR-II-NLZOH-K-42 1.izdaja Velja od: 2.7.2018 Stran: 20 od 20

Tip obsega: fleksibilni (možnost uvajanja manjših sprememb metode / Type of scope: flexible (possibility of implementing minor s of the method Področja preskušanja glede na vrsto preskušanca: okolje in vzorci iz okolja (, odpadki) / Testing fields with reference to the type of test item: environment and samples from the environment (, s) nestandardne preskusne metode metode in morebitne navezave na druge standarde ali metode Title of standard or non-standard Range of testing; Uncertainty of the result of testing (where relevant) 63. EPA 528:2000 modificiran Določanje fenolov v vodah z metodo plinske kromatografije v povezavi z masno selektivnim detektorjem po ekstrakciji na trdni fazi Determination of phenols in drinking water by solid phase extraction and capillary column gas chromatography/mass spectrometry 64. EPA 1668C:2010 Določanje kloriranih bifenilov v vodi, tleh in sedimentu metodo HRGC/HRMS Chlorinated biphenyl congeners in water, soil, sediment and tissue by HRGC/HRMS (0,05 5) g/l fenol 3-metilfenol 2-metilfenol 4-metilfenol 2-klorofenol 2,4-dimetilfenol 3,5-dimetilfenol 2-metoksifenol 2,4-diklorofenol 2,6-diklorofenol 4-kloro-3-metilfenol 2,4,5-triklorofenol 2,4,6-triklorofenol 2,4-dinitrofenol 2-nitrofenol 4-nitrofenol 2-metil-4,6-dinitrofenol pentaklorofenol 2(metilpropil)-4,6- dinitrofenol 0,1 ng/l 100 μg/l PCB 77 PCB 81 PCB 126 PCB 169 mineralne, bazenske, odpadne suraface, mineral, pool, 05.02.2015 17.02.2012 PCB 105 PCB 114 PCB 118 PCB 123 PCB 156 PCB 157 PCB 167 PCB 189 65. SIST ISO 17852: 2008 modificiran Kakovost Določevanje živega srebra Metoda atomske fluorescenčne spektrometrije Water quality Determination of mercury Method using atomic fluorescence spectrometry (10 100) ng/l površinske surface 17.02.2012 66. SIST EN 15216: 2008 Karakterizacija odpadkov Določevanje celotnih raztopljenih snovi (TDS) v izlužkih Characterization of Determination of total dissolved solids (TDS) v vodi in izlužkih (400-5000)mg/L (4000 50000) mg/kg s.s. odpadki (izlužek) (leachate) Priprava izlužka po SIST EN 12457-4: 2004 OBR-II-NLZOH-K-42 1.izdaja Velja od: 2.7.2018 Stran: 21 od 21

Tabela / Table 3 Tip obsega: fleksibilni (možnost uvajanja manjših sprememb metode / Type of scope: flexible (possibility of implementing minor s of the method Področja preskušanja glede na vrsto preskušanca: okolje in vzorci iz okolja (tla, odpadki) / Testing fields with reference to the type of test item: environment and samples from the environment (soil, s) nestandardne preskusne metode metode in morebitne navezave na druge standarde ali metode Title of standard or non-standard and eventual relations to other standards or methods Range of testing; Uncertainty of the result of testing (where relevant) 67. SIST EN 15308:2017 modificiran Karakterizacija odpadkov Analiza izbranih polikloriranih bifenilov (PCB) v trdnih odpadkih s kapilarno plinsko kromatografijo z detektorjem na zajetje elektronov ali masnospektrometričnim detektorjem Characterization of Determination of selected polychlorinated biphenyls (PCB) in solid by using capillary gas chromatography with electron capture or mass spectrometric detection (0,01 1,0) mg/kg s.s PCB 28 PCB 52 PCB 101 PCB 118 PCB 138 PCB 153 PCB 180 trdni odpadki solid Priprava preskusnih vzorcev iz laboratorijskega vzorca po SIST EN 15002:2015 68. EPA 1668C:2010 Določanje kloriranih bifenilov v vodi, tleh in sedimentu metodo HRGC/HRMS Chlorinated biphenyl congeners in water, soil, sediment and tissue by HRGC/HRMS Priprava preskusnega vzorca tal iz laboratorijskega vzorca po ISO 14507:2003 0,5 ng/kg 100 μg/kg s.s. PCB 77 PCB 81 PCB 126 PCB 169 sediment, tla sediments, soil 22.06.2016 Priprava preskusnega vzorca sedimenta iz laboratorijskega vzorca po navodilih za delo ND- IV-NLZOH-OOZ Mb-12 PCB 105 PCB 114 PCB 118 PCB 123 PCB 156 PCB 157 PCB 167 PCB 189 69. EPA 7473:2007 Določevanja živega srebra v raztopinah in trdnih snoveh z atomsko absorpcijsko spektroskopijo po termičnem razklopu in amalgamaciji Mercury in solids and solutions by thermal decomposition, amalgamation and atomic absorption spectrometry Hg (50 5000) µg/kg s.s. tla, sedimenti, odpadki soil, sediments, Priprava preskusnega vzorca tal iz laboratorijskega vzorca po SIST ISO 11464:2006 Priprava preskusnega vzorca sedimenta iz laboratorijskega vzorca po navodilih za delo ND-IV-NLZOH-OOZ Mb-12 Priprava preskusnega vzorca iz laboratorijskega vzorca odpadka po SIST EN 15002: 2015 OBR-II-NLZOH-K-42 1.izdaja Velja od: 2.7.2018 Stran: 22 od 22

Tip obsega: fleksibilni (možnost uvajanja manjših sprememb metode / Type of scope: flexible (possibility of implementing minor s of the method Področja preskušanja glede na vrsto preskušanca: okolje in vzorci iz okolja (tla, odpadki) / Testing fields with reference to the type of test item: environment and samples from the environment (soil, s) nestandardne preskusne metode metode in morebitne navezave na druge standarde ali metode Title of standard or non-standard and eventual relations to other standards or methods 70. ISO 15936 Blato, obdelani biološki odpadki, tla in odpadki - Določevanje celotnega organskega ogljika (TOC) s suhim sežigom Sludge, treated bio, soil and - Determination of total organic carbon (TOC) by dry combustion 71. ISO 6439:1990 modificiran Kakovost Določanje fenolnega indeksa Spektrofotometrijska metoda s 4- aminoantipirinom s predhodno destilacijo Water quality Determination of phenol index 4 aminoantipyrine spectrometric method after distillation Range of testing; Uncertainty of the result of testing (where relevant) TOC (0,1-30) % s.s. tla, blato, biološki odpadki, odpadki soil, sludge, treated bio, (0,1 300) mg/kg s.s. tla, odpadki soil, 22.06.2016 Priprava preskusnega vzorca iz laboratorijskega vzorca odpadka po SIST EN 15002:2015 Priprava preskusnega vzorca iz laboratorijskega vzorca tal po ISO 14507:2003 72. SIST EN 15169:2007 Točka 9.1 Point 9.1 Karakterizacija odpadkov Določevanje žarilne izgube odpadka, blata in sedimentov Characterization of Determination of loss on ignition in, sludge and sediments žarilna izgiba (1 95) % s.s. odpadki 04.09.2015 Priprava preskusnega vzorca iz laboratorijskega vzorca po SIST EN 15002:2015 73. ISO 11465:1993 Kakovost tal Ugotavljanje suhe snovi in vsebnost na osnovi mase v tleh in odpadkih Gravimetrijska metoda Soil quality Determination of dry matter and water content on a mass basis gravimetric method suha snov: (30 99) % tla soil 22.06.2016 Priprava preskusnega vzorca iz laboratorijskega vzorca po SIST ISO 11464:2006 74. SIST EN 14346:2007 metoda A method A Karakterizacija odpadkov Izračun suhe snovi z določitvijo suhega ostanka ali Characterization of Calculation of dry matter by determination of dry residue or water content suha snov. (20 99) % odpadki 22.06.2016 Priprava preskusnega vzorca iz laboratorijskega vzorca po SIST EN 15002:2015 75. SIST EN 12880:2001 Karakterizacija blata - Določevanje ostanka po sušenju in količine Characterization of sludges - Determination of dry residue and water content suha snov (1 99) % blato, digestat sludge, digestate 22.06.2016 OBR-II-NLZOH-K-42 1.izdaja Velja od: 2.7.2018 Stran: 23 od 23

Tip obsega: fleksibilni (možnost uvajanja manjših sprememb metode / Type of scope: flexible (possibility of implementing minor s of the method Področja preskušanja glede na vrsto preskušanca: okolje in vzorci iz okolja (tla, odpadki) / Testing fields with reference to the type of test item: environment and samples from the environment (soil, s) nestandardne preskusne metode metode in morebitne navezave na druge standarde ali metode Title of standard or non-standard and eventual relations to other standards or methods 76. ISO 10390:2005 Kakovost tal Ugotavljanje ph Soil quality Determination of ph Range of testing; Uncertainty of the result of testing (where relevant) 4-8,5 tla soil Priprava preskusnega vzorca iz laboratorijskega vzorca tal po SIST ISO 11464: 2006 77. ISO 11261:1995 modificiran Kakovost tal Ugotavljanje skupnega dušika Modificiran Kjeldahlova metoda Soil quality Determination of total nitrogen Modified Kjeldahl method (0,05 3) % s.s. N tla, sediment soil, sediment 22.06.2016 Priprava preskusnega vzorca iz laboratorijskega vzorca tal po SIST ISO 11464: 2006 Priprava preskusnega vzorca iz laboratorijskega vzorca sedimenta po navodilih za delo ND-IV-NLZOH- OOZ Mb-12 78. SIST EN 13654-1:2002 Izboljševalci tal in rastni substrati Določevanje dušika 1. del: Spremenjena Kjeldahlova metoda Soil improvers and growing media - Determination of nitrogen - Part 1: Modified Kjeldahl method (0,10 10)% s.s. N kompost, blato, digestat compost, sludge, digestate 22.06.2016 79. SIST EN 14039:2005 Karakterizacija odpadkov Določevanje ogljikovodikov v območju od C 10 do C 40 s plinsko kromatografijo Characterization of Determination of hydrocarbon content in the range of C 10 to C 40 by gas chromatography (20 10000) mg/kg s.s. odpadna tla, odpadni sedimenti soils, sediments Priprava preskusnega vzorca iz laboratorijskega vzorca po SIST EN 15002:2015 OBR-II-NLZOH-K-42 1.izdaja Velja od: 2.7.2018 Stran: 24 od 24

Tip obsega: fleksibilni (možnost uvajanja manjših sprememb metode / Type of scope: flexible (possibility of implementing minor s of the method Področja preskušanja glede na vrsto preskušanca: okolje in vzorci iz okolja (tla, odpadki) / Testing fields with reference to the type of test item: environment and samples from the environment (soil, s) nestandardne preskusne metode metode in morebitne navezave na druge standarde ali metode Title of standard or non-standard and eventual relations to other standards or methods Range of testing; Uncertainty of the result of testing (where relevant) 80. ND-IV-NLZOH-OKAMB-92 izdaja 9 interna metoda in-house method Določanje nekaterih pesticidov v vzorcih tal z metodo plinske kromatografije z masno selektivnim detektorjem Determination of selected pesticide residues in soil by GC-MSD Priprava preskusnega vzorca iz laboratorijskega vzorca po ISO 14507:2003 (0,005 5) mg/kg s.s. 2,6-diklorobenzamid 2-etil-6-metil 2- kloroacetanilid acetoklor alaklor atrazin cianazin desetil atrazin desetil terbutilazin des-izo-propil atrazin diklobenil dimetenamid flufenacet metalaksil metolaklor prometrin propazin sebutilazin simazin terbutilazin terbutrin flurokloridon metazaklor pendimetalin tla soil 81. ISO 17294-2:2016 modificiran Kakovost - Uporaba masne spektrometrije z induktivno sklopljeno plazmo (ICP/MS) - 2. del: Določevanje izbranih elementov, vključno z izotopi urana Water quality - Application of inductively coupled plasma mass spectrometry (ICP-MS) - Part 2: Determination of selected elements including uranium isotopes v mg/kg s.s.: Cd: 0,10 20 Cr: 5 1000 Cu: 5 1000 Ni: 5 1000 Pb: 5 1000 Zn: 10 2000 tla, sediment soil, sediments 26.09.2016 Priprava preskusnega vzorca iz laboratorijskega vzorca tal po SIST ISO 11464: 2006 Priprava preskusnega vzorca iz laboratorijskega vzorca sedimenta po navodilih za delo ND-IV-NLZOH- OOZ Mb-12 Razklop preskusnega vzorca po ISO11466:1995 OBR-II-NLZOH-K-42 1.izdaja Velja od: 2.7.2018 Stran: 25 od 25