AIRE ACONDICIONADO PORTATIL

Similar documents
INSTALLATION &OPERATIONS MANUAL PORTABLE AIR CONDITIONER KOREL AIR CONDITIONING KMA1-12GRC FOR FUTURE REFERENCE

Table of Contents. Notice: Any maintenance should be returned to the dealer or factory! Attention: Please read this instruction carefully before use.

MOBILE ROOM AIR CONDITIONER

INSTALLATION &OPERATIONS MANUAL

PORTABLE AIR CONDITIONER

Model No. PE2-07R / PE2-09R / 9000 BTU Portable Air Conditioner with dehumidifier & Fan PE2-07R-62 / PE2-09R-32 Operating Instructions

Portable Air Conditioner and Heater With Heat Pump Technology Operating Instructions. Model No.: PH3-12R-03 Reference No.: KY2-34

Downloaded from manuals search engine

PORTABLE AIR CONDITIONER

Dual-Hose Portable Air Conditioner User Manual

Portable Air Conditioner with Evaporative Technology PE6-10R-03 Operating Instructions. Model No. PE6-10R Soleus Air International

Model No. GB-PAC-08E4. 8,000 BTU Portable Air Conditioner Operating Instructions

Model No.: PS08-01 PS10-01 Ref: KY80 KY100

Portable Air Conditioner, Dehumidifier,Heater and Fan utilizing Heat Pump Technology

Portable Air Conditioner with Heat Pump Technology PH4-10R-01, PH4-12R-01, & PH4-14R-01 Operating Instructions

Instruction Manual. Portable Air Conditioner

- Cooling - Heating - Dehumidifying - Fan. Please read this owner s Manual carefully before operating the unit. -1-

Portable Air Conditioner with Heat Pump Technology Operating Instructions. Model No.: HCB-P13HP-D. Reference No.: BPD13HP V140217

11,000 BTU Portable Air Conditioner with dehumidifier & Fan PE4-11R-03 Operating Instructions. Model No. PE4-11R Soleus Air International

15,000 BTU Portable Air Conditioner

14,000 BTU Portable Air Conditioner 14,200 BTU Heat Pump Model Number: LX-140 Operating Instructions. Model No. LX Soleus Air International

ACCESSORIES INCLUDED

Moveable Air-conditioner User s Manual

USER MANUAL. Portable Air Conditioner and Heater With Heat Pump Technology PAC18. Please read this manual carefully prior to operating the product.

Operating Instructions

Owner s Manual. Portable Air Conditioner ARP-5008 ARP Royal Sovereign International, Inc.

5) Do not start or stop the unit by inserting or pulling out the power plug.

Air Conditioner PORTABLE. Instruction Manual. Your Guarantee. Portable Air Conditioner / Heater. For model WA-7500M

Air Conditioner PORTABLE. Instruction Manual. Your Guarantee. Portable Air Conditioner / Heater. For models WA-1010E, WA-1010H, WA-1010M

Portable Air Conditioner 6,000 BTU 8,000 BTU 10,000 BTU

3 In 1 AIR CONDITIONER with REMOTE CONTROL MODEL NO: CA9000 PART No: OPERATION & MAINTENANCE INSTRUCTIONS

MODEL: DC10RCDH / DC12RCDH

12,000 BTU Portable Air Conditioner PE3-12R-03. Model No. PE3-12R Soleus Air International

Air Conditioner. Instruction Manual. For Models WA-1010E, WA-1010H, WA-1010M WA-1230E, WA-1230H P O R T A B L E

CR13000-PAC OWNER S MANUAL. Portable Air Conditioner. PORTABLE AIR CONDITIONER with HEAT PUMP. Operating and Servicing Instructions

PORTABLE AIR CONDITIONER (LOCAL)

PORTABLE AIR CONDITIONER (LOCAL)

NORTH STORM. 4-in-1 AIR CONDITIONER USER MANUAL TABLE OF CONTENTS

Sunleaves Air Conditioner

Utopian Split A/C. Thank you for purchasing this quality Split A/C system!

CLIM9000CE PORTABLE AIR CONDITIONER USER MANUAL

Reverse Cycle Portable Air Conditioner with Dehumidifier

Portable Room Air Conditioner and Heat Pump


53 KNL / 53 QNL OWNER S MANUAL

PLEASEREADANDSAVETHESEINSTRUCTIONS. NewAir AC-14000E, AC-14000H Portable Air Conditioner Owner's Manual

PORTABLE AIR CONDITIONER (LOCAL)

!3 _!!ili_ '_:_i_;iii_ SG-PAC-12E1 SG-PAC- 12E 1HP. 12,000 BTU Portable Air Conditioner

SILENT 12 PORTABLE AIR CONDITIONER USER MANUAL

Portable Air Conditioner USER MANUAL

USER MANUAL SILENT16 PORTABLE AIR CONDITIONER

Owner s Manual Super-Slim Four-Way Cassette

ARTICA. 8000Btu. Room Air Conditioners Portable Range

OWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36

Portable Air Conditioner Instruction Manual

Dehumidifier. Model: GDN20AX-K4EBA1A GDN20AX-K4EBA1B

Bosch Split-Type Ductless Air Conditioner / Heat Pump

PORTABLE AIR CONDITIONER

COMPACT PORTABLE AIR CONDITIONER USER MANUAL

Owner s Manual. Middle Static Pressure Duct Type MEU-18MPH2 MEU-24MPH2 MEU-36MPL2 MEU-48MPL2 MIDDLE STATIC PRESSURE DUCT TYPE AIR CONDITIONER

WINDOW TYPE ROOM AIR CONDITIONER OPERATION AND INSTALLATION MANUAL

AC Portable Air Conditioner AC-14100E, AC-14100H OWNERS MANUAL. Read and save these instructions.

LOCAL AIR CONDITIONER

GMSG OWNER S MANUAL SPLIT-SYSTEM ROOM AIR CONDITIONER CONTENTS

Model No. SG-PAC-10E2 Reference No. KY ,000 BTU Portable Air Conditioner Operating Instructions

INVERTER ONE-TWO/ONE-THREE/ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER

AC-12200E Portable Air Conditioner

OWNER'S MANUAL R-410A Duct Free Split System Air Conditioner and Heat Pump

Portable Air Conditioner

Portable Air Conditioner

OWNER S MANUAL. Portable Refrigerated Air Conditioner. CP12CW2 (English) (CP12CW2)

PC20-AMFII / PC40-AMF USER MANUAL

PAC12H. 12,000btu Cool & Heat Portable Air Conditioner. Please read this manual carefully prior to operating the product.

OWNER S MANUAL Dehumidifier GDN50AP-A3EBA1A GDN70AP-A3EBA1B

Air Conditioner Features...8 Operating Instruction Care and Cleaning...17 Before You Call...18 Major Appliance Limited Warranty...

Mobile Air Conditioner Use and Care Manual. Part Number: 048-GM-48265

OWNER S MANUAL. High-Wall Fan Coil Unit CONTENTS

PAC12J. 12,000btu Cool & Heat Portable Air Conditioner. Please read this manual carefully prior to operating the product.

Portable Dehumidifier with Internal Pump

USER MANUAL TPS-M5/M55/M555

USER MANUAL SILENT12 PORTABLE AIR CONDITIONER

PORTABLE AIR CONDITIONER

Using the Remote Control Unit

OWNER S MANUAL. Portable Air Conditioner. Product defect? Not working properly? DO NOT return this product to the store where you purchased it.

IMPORTANT SAFETY INSTRUCTIONS

Mobile Type AIR CONDITIONERS (LOCAL AIR CONDITIONERS)

CAREFULLY READ THESE INSTRUCTIONS BEFORE USING SAFETY PRECAUTIONS USE OF EXTENSION CORDS

OWNER S MANUAL. R 410A Ductless Split System Air Conditioner and Heat Pump

KSD-35 DR11 KUE-35 DVN11

51AKS I S O OWNER S MANUAL

Inverter Split-type Room Air Conditioner

OWNER S MANUAL KPD-105 DTN11 KPD-140 DVN11 KPD-140 DTN11 KPD-160 DTN11 KPD-52 DVR11

SERVICE NUMBER ( )

WA-1240E: 12,000 BTU Cooling only WA-1240H: 12,000 BTU Cooling and Heating WA-1420E: 14,000 BTU Cooling only WA-1420H: 14,000 BTU Cooling and Heating

Owner s Manual INVERTER ONE-TWO/ONE-THREE /ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER

OWNER'S MANUAL MODEL: P-08PE P-12PE. For any service needs, call

GL-DEH Series Portable Dehumidifier Operating Instructions

Owner s Manual INVERTER ONE-TWO/ONE-THREE /ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER

PORTABLE AIR CONDITIONER WITH HEATER ... WA-9061 H" 9,000 BTU WA H" 10,000BTU

Operating Instructions Air Conditioner

Transcription:

MANUAL DE INSTRUCCIONES AIRE ACONDICIONADO PORTATIL AA-1824 AA-1825 ESTIMADO CLIENTE Felicitaciones por su compra! Por favor lea cuidadosamente este manual, y guadelo para su futura referencia. Si necesita soporte adicional, no dude en escribir a: info@premiermundo.com

R

Pagina 1

AM-09A4/R 9000 330 5.2 1150 AM-12A4/R 12000 330 5.2 1150 1PH 220V-240V~/50Hz R407c 33 56 37.8 36.8 33.8 56 83.8 10-15 14-20 DB 35 21 WB 25 15 Pagina 2

Veleta de direcion flujo de aire (horizontal) Veleta de direcion flujo de aire (vertical) Salida de aire Panel superior Panel de control Panel derecho Hueco de asidero Panel frontal Tanque de agua Ruedas Panel trasero Entrada de aire Filtro aire(interior) Conducto saida de aire Perchas de calbe Panel izquirerdo Cable Entrada de aire(condensador) VISTA TRASERA VISTA LATERAL IZOUIERDA Pagina 3

1 1 1 1 4 4 2 1 Indicador de tiempo Indicador de modo (fresco/seco/ventilador) Indicador velocidad ventilador (baja/media/alta) Pantalla digital COOL DRY FAN LOW MED HIGH TIMER ON/OFF MODE FAN ON/OFF SLEEP WATER FULL SWING UP DOWN Indicador dormir Indicador de Agua llena ~ Recibidor de senal Pagina 4

Pagina 5

Pagina 6

Mas de 50 cm Mas de 50 cm Adaptador B Pagina 7

Adaptador A Clavija I Max 120cm Min 30cm Ino! Pagina 8

Ventana horizontal IMAGEN A IMAGEN B Piezas deslizantes para ventanas minimo 67.5 cm maximo 123 cm Piezas deslizantes para ventanas minimo 67.5 cm maximo 123 cm Ventana vertical Pagina 9

Pagina 10

Pagina 11

15998001155

INSTRUCTION MANUAL PORTABLE AIR CONDITIONER AA-1824 AA-1825 DEAR CUSTOMER Congratulations for your purchase! Please read this manual carefully, and keep it for future reference. If you need extra support, please write to info@premiermundo.com

CONTENTS Belief Introduction...1 Technical Specification...2 Parts Description...3 Accessories...4 Control Panel...4 Operation...5 Installation...7 Maintenance...9 Troubleshooting...10

Belief Introduction This mobile air conditioner is a new generation air conditioner which is ideal for using in bedroom, study room, lobby, office, meeting room, warehouse, attics, sports hall and other entertainment room. Its flexibility characteristic enable easy adjustment to desirable room temperature and humidity. Besides, the built-in filter can remove floating dust, purify air to create a healthy working environment. It is designed under novelty, practically and convenience principles to satisfy the needs for convenient, efficient and mobile small-sized air conditioner. It features easy using, no need for complicated installation and convenient maintenance. Besides, the double control system (remote control /manual control optional ) eases its operation. The unit is highly competitive to other cooling capable products. With tidy structure, multiple functions and reasonable ventilation design, the unit minimizes noise and power consumption. Aiming at harmonious human life, our company adopts human factors into design, produced this high efficiency mobile air conditioner. Page 1

Technical Specifications Model Cooling capacity (Btu/h) 3 Air flow (m /h) Rated current (A) Rated input (W) Power supply Refrigerant Weight (kg) Noise db(a) Dimension(mm) 2 Suitable room area (m ) AM-09A3 9000 12000 340 340 8.0 8.5 900 950 115V~/60Hz AM-12A3 115V~/60Hz R22 R22 34 34 56 56 378 368 838 378 368 838 10-15 15-20 Note: 1.The above cooling capacity are calculated at ambient temperature DB 30, WB 25.4. 2.Our company has quick technical improvement. There will be no prior notice for any change of technical data. Please read the nameplate on the air conditioner. Working temperature range DB WB Maximum cooling Minimum cooling 35 25 21 15 Page 2

Parts Description Airflow direction vane (horizontal ) Airflow direction vane (vertical ) Air outlet Top panel Control panel Right panel Handle recess Front panel Water tank Remote controller Truckle FRONT VIEW Rear panel Air inlet Air filter (inside) Exhaust air outlet Cord hanger Left panel Power cord Air intake(condenser) REAR VIEW LEFT SIDE VIEW Page 3

Accessories Parts Parts name Quantity Duct Adaptor A (for permanent mounting use) Cover (cover the hole when not in use) Adaptor B(for temporary mounting use) Wall plug Screw Alkaline batteries 1 1 1 1 4 4 2 Remote controller 1 Control Panel Timer indicator Mode indicator Fan speed indicator Digital display COOL DRY FAN LOW MED HIGH TIMER ON/OFF MODE FAN ON/OFF SLEEP WATER FULL SWING UP DOWN Sleep indicator Water full indicator Signal receiver Page 4

Function Buttons SLEEP button Press this button to set the sleep state. TIMER ON/OFF button Press this button to initiate the auto-on or auto-off timesequence. MODE button Each time you push the button, amode is selected in a sequence that goes from cool, dry and fan. FAN button This button is used for setting fanspeed in the sequence that goes from Low Med, to High, then back to Low. SWING button Press the button to change the swing angle oflouver. UP button Push the button to make the indoor setting temperature increase. DOWN button Push the button to make the indoor setting temperature decrease. ON/OFF button To turn on or off the unit. Note :The functions of these buttons are the same asyour remote controller's. Operation WARNING 1.Plug unit only into grounded electrical outlet. 2.Do not use an extension cord or plug adaptor with this unit. 3.Do not operate unit with front removed. Failure to follow the above precaution could result in electrical shock, fire or personal injury. Before starting the unit 1) Select a suitable location, making sure you have easy access to an electrical outlet. 2) Install the flexible exhaust hose and the adjustable window slider kit. 3) Plug the unit into a 220V-240V socket. 4) Make sure the water tank is correctly positioned inside the cabinet otherwise the unit will not operate. 5) To turn the unit on. Cooling operation mode 1. Press the MODE button in a sequence until the cool indicator lighted. 2. Press the UP and DOWN button to adjust your desired set temperature. 3. Press FAN button to select the fan speed. 4. Press the SWING button to change the airflow direction. 5. Press ON/OFF button to start the unit and press it again to stop. Page 5

Dehumidifying operation mode 1. Press the MODE button in a sequence until the dry indicator lighted. 2. The fan will run at a fixed speed at this operation mode. 3. Close windows and doors for the best dehumidifying effect. 4. Do not put the duct to window. 5. Press ON/OFF button to start the unit and press it again to stop. Circulation operation mode 1. Press MODE button in a sequence until the fan indicator lighted. 2. Press the FAN button to choose the fan speed.(low-med-high) 3. Do not put the duct to window. 4. Press the on/off button to start the unit and press it again to stop. Timer operation 1. Press the TIMER ON or TIMER OFF button. Wind direction adjusting Horizontal airflow (automatically) Press the SWING button, the vertical vanes rotate automatically. If you have a desired direction, you also can press it again to stop at the position. Vertical airflow(manually) Grab and rotate the middle horizontal vane manually. Note: Adjusting the vertical vane by hand in automatically-controlled operation may damage the step-motor. Deal with condensate Condensate in water tank 1.When the water tank is full, dehumidification process will immediately stop. However,the fan motor will continue to operate for two minutes, then the LED will display PI and the unit will alarm, at the same time the water full indicator light starts flashing continuously. 2. Carefully remove the water tank from the cabinet and dispose of the water. Replace the water tank back to its original position and the dehumidifying process will automatically resume. It will take 3 minutes for the compressor to restart. This is normal.. Continuous drainage 1. Drain water can be collected externally by directing the rubber tube(inner diameter:12mm~12.5mm) inside the drain tank cabin through the water tank to any vessel such as bucket. Remove the rubber tube cap before operate. 2.Do not take out the water tank during drainage. IMPORTANT: This water is not suitable for drinking. Please insert the rubber tube cap into the drain tank cabin when the continuous drainage function is off. NOTE:it will be easier to operate if the rubber tube cap is wetted by suds. Page 6

Installation Guide of customer The customer should have a qualified power supply coincident with that printed on the tag of the air conditioner. Its voltage should be in the range of 90%-110% of its rated voltage. Must use special circuit and efficient grounding socket matching with the plug of the air conditioner. If the supply wire is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. Select a best location Install the mobile air conditioner in a flat and spacious location where the air outlets will not be covered up. A minimum clearance of 50cm from walls or other obstacles should be kept. The appliance shall not be used in the laundry. The plug shall accessible after appliance is positioned. More than 50cm More than 50cm Duct mount instruction Temporary 1.Attach one end of the duct to the exhaust air outlet of the mobile air conditioner. According to the arrow direction, first fit the left side of the duct on the exhaust air panel, then the right side duct. Push it downwards, be sure to fix thoroughly. 2.Attach the other end of the duct to adaptor B. Adaptor B 3.Put the end of duct to a nearby window. Page 7

Permanent 1.Attach one end of the duct to the exhaust air outlet of the mobile air conditioner. According to the arrow direction, first fit the left side of the duct on the exhaust air panel, then the right side duct. Push it downwards, be sure to fix thoroughly. 2.Install the adaptor A onto the wall Amplified view for I by using 4 wall plugs and screws. Adaptor A 3.Attach the other end of the duct to adaptor A. 4.Cover the hole using the adaptor Wall plugs cap when not in use. I Max 120cm Min 30cm Note: 1.The duct can be compressed to 450mm minimum and extended to 1800mm maximum. It is better to keep the duct length to a minimum. 2.Over stretching or bending the duct will affect the cooling efficiency. (As the following fig. show) Do not! Page 8

Window kit installation Your window kit has been design to fit most standard vertical and horizontal window applications. However, it may be necessary for you to improvise or modify some aspects of the installation procedure for certain types of window. Please refer to fig. A &fig. B for minimum and maximum window openings. Horizontal window Fig. A Fig. B Window slide kit minimum:67.5cm maximum:123cm Window slide kit minimum:67.5cm maximum:123cm Vertical window Maintenance Your new air conditioner is designed to give you many years of dependable service. This section tells you how to clean and care for your air conditioner properly. Call your local authorized dealer for an annual checkup. Remember the cost of this service call is your responsibility. Cleaning Air Filter If the air filter is covered by dust, the cooling effect will be undermined. Please clean the air filter every two weeks. 1. Unplug air conditioner or disconnect power. 2. Pull out the filter cover and remove the from the filter cover. 3. Wash air filter in warm soapy water. Do air filter in the dishwasher or use any chemical cleaners. Air dry filter completely before replacing to ensure max. efficiency. 4. Attach the air filter to the filter cover using the attachment hooks on the inner surface of the cover. Put the filter cover back to its place. 5. Plug in air conditioner or reconnect power. Cleaning The Unit 1.For the purpose of safety, please turn off the air-conditioner and cut off the power supply. Page 9

2.Wipe the unit with dry cloth. 3.If the unit is very dirty, please wipe with wet cloth dipped by cold water. Cleaning Drain Tank Wash the tank using warm water with neutral detergent. Rinse and then dry in a cool place. Put the tank to its original place after it is dried completely. Do not use gasoline,benzene,thinner or any other chemicals, or any liquid insecticide on the air conditioner, as these substances may cause flaking off of the paint,cracking or deformation of plastic parts. Never attempt to clean the unit by pouring water directly over any of the surface areas, as this will cause deterioration of electrical components and wiring insulation. Never use hot water over 40 (104 )to clean the air filter. You can solve many common air conditioner problem easily, saving you the cost of a service call, try the suggestions below to see if you can solve your problem without outside help. Air Condition Will Not Operate Causes The power switch is released. Power supply failure. The fuse is burnt. It doesn't reach the set time for start up. Troubleshooting Unit Doesn't Start When Pressing On/off Button Solutions Switch on the power. Wait for the recovery of power supply. Replace the fuse. Wait or eliminate the original setting. Causes Water full indicator blinks, drain tank is full. It is not three minutes after switch off. Room temperature is lower than the set temperature. Solutions Dump the water in the drain tank. Wait three minutes. Reset the temperature. Page 10

The Wind Blowing Out, But The Cooling Effect Is Bad Causes Mistakes in temperature setting. The air filter is blocked by dust. The air inlet or outlet of machine is blocked. Unit recently turned on in hot room. Insufficient cooling capacity. The doors or windows are open. Solutions Set a proper temperature, see the methods of application. Clean the air filter. Remove the obstruction. Allow additional time to remove stored heat from walls,ceiling, floor and furniture. Reconfirm the required cooling capacity with your dealer. Close the doors and windows. Noise or vibration Causes The ground is not level or not flat enough. Solutions Place the unit on a flat, level ground if possible. Page 11

15998004497 01258