Novel Liquid Desiccant Systems

Similar documents
Modular Air Handling Units TECHNICAL CATALOGUE

RISKY REFRIGERANTS AND REDUCES ELECTRICAL CONSUMPTION BY

Vicot Air Conditioning Co., Ltd. CONTENT

FAST AND ROBUST BUILDING SIMULATION SOFTWARE. Chilled Beam Performance: 1 Shelly Street, Sydney

Experimental Investigation of a Multi Effect Membrane Based Regenerator for High Concentration Aqueous LiCL Solution as Desiccant

Adsorption Chillers Energysmart Green Cooling

State of the art building simulation software... Frenger Radiant chilled beam performance at 1 Shelly St - Sydney

Liquid Desiccant Air Conditioning Systems

ACMVTECH HIGH EFFICIENCY UNITARY AHU

INSTITUTE FOR ENVIRONMENTAL RESEARCH & SUSTAINABLE DEVELOPMENT NATIONAL OBSERVATORY OF ATHENS (NOA)

Ultra Efficient Desiccant Based Evaporative Cooling for Air- Conditioning

SEMCO CHILLED BEAMS INDOOR AIR QUALITY AND ENERGY SAVINGS FANLESS FILTERLESS SPACE CONDITIONING

Feasibility of a Liquid Desiccant Application in an Evaporative. Cooling Assisted 100% Outdoor Air System

Modular Active. Chilled. Beams

Available online at ScienceDirect. Procedia Engineering 121 (2015 )

Kawasaki centrifugal chiller using water as a refrigerant. Sep 26 th 2017 Kawasaki Heavy Industries, Ltd. Machinery Division Hayato Sakamoto

EVALUATION OF A LIQUID DESICCANT AIR CONDITIONING SYSTEM WITH SOLAR THERMAL REGENERATION

Low Energy Air Conditioning

Comparison Simulation between Ventilation and Recirculation of Solar Desiccant Cooling System by TRNSYS in Hot and Humid Area

Benefits Offered by Passive Dehumidification Wheel Speed Control

Recent Advances in Energy, Environment and Economic Development

Available online at Energy Procedia 6 (2011) MEDGREEN 2011-LB

Customers. The core of our innovation. Feeding&Conveying. Drying Dosing Temperature Control Refrigeration Granulation

Feasibility study on an energy-saving desiccant wheel system with CO 2 heat pump

Solar Heating and Cooling Systems

SIMULATION ANALYSIS OF BUILDING HUMIDITY CONTROL AND ENERGY CONSUMPTION FOR DIFFERENT SYSTEM CONFIGURATIONS USA

DEHUMIDIFICATION: Ice Arena Application & Product Guide. Design, construct and operate to control indoor humidity in ice rinks

Implementation of Energy Saving measures in Existing Buildings

SYSTEM DESIGN REQUIREMENTS

Desiccant Cooling with Solar Energy

Temperature. In the HVAC area, we talk about two kinds of temperatures.

Liquid Desiccant Technology Delivers Energy Cost Reductions and Indoor Air Quality Improvements. White Paper

NEW GENERATION INTELLIGENT ADIABATIC PRE-COOLING SYSTEM

A SOLAR LIQUID-DESICCANT AIR CONDITIONER

The product segments Heating, ventilation, air conditioning. Control Products & Systems OEM.

High Efficiency Heating and Cooling Systems for Community Colleges Kirk Mescher, PE, LEED AP Principal ICCCFO

MECCI Engineers. Institute of Engineering Design & Research

Air Conditioning and process cooling Energy Components at a Glance

Optimization of Moisture condensation rate of Liquid Desiccant Dehumidifier through Genetic Algorithm

HVAC Mandatory Provisions Part II, Page 1

General HVAC Recommendations

Daikin VRV Systems Plugin VE2012 User Guide

seasons in regions with hot, humid climates. For this reason, a dehumidification system with a radiant panel system needs to be developed. In a former

K.F. Fong *, C.K. Lee, T.T. Chow

DEVELOPMENT OF THE WORLD S FIRST SMALL-SCALE TWO-STAGE ABSORPTION CHILLER/HEATER/HOT-WATER SYSTEM

Asia Pacific Research Initiative for Sustainable Energy Systems 2013 (APRISES13)

Impact of indirect evaporative air cooler type on the performance of desiccant systems

Session: HVAC 101 HVAC 101. Steve Sain Sain Engineering Associates, Inc. August 9, Rhode Island Convention Center Providence, Rhode Island

AIR TREATMENT. ReCOOLER HP» INTEGRATED COOLING/HEATING FUNCTION WITH REVERSIBLE HEAT PUMP IN THE eq AIR HANDLING UNIT

MODELING AND OPTIMIZATION FOR REGENERATOR WITH HEAT RECOVERY IN LIQUID DESICCANT DEHUMIDIFICATION SYSTEM

Performance evaluation of a liquid desiccant solar air conditioning system

Haitian Jupiter Series

THE FIELD OPERATION OF A THERMALLY DRIVEN LIQUID-DESICCANT AIR CONDITIONER

Liquid desiccant dehumidification systems. Product guide

SOLAR AIR CONDITONING SYSTEM USING DESSICANTS

Industrial Heat Pumped Hot Water

Energy Efficiency Through Waste Heat Recovery. Heat Recovery Centrifugal Chillers and Templifier Water Heaters

INDUSTRIAL APPLICATIONS THE PROMISE THE PROOF HEATEX AIR-TO-AIR HEAT EXCHANGERS

LG VRF Systems. Air Conditioning Technologies

Theoretical Performance Analysis of a Liquid Desiccant Air- Conditioning System for Air Heating and Cooling

2010 Green Product Portfolio

Chilled beam technology overview John Woollett 1, Jonas Åkesson 2 Swegon AB 1,2

Technical Data Sheet

INTRODUCTION HVAC BASICS AND HVAC SYSTEM EFFICIENCY IMPROVEMENT SECTION O 4/19/2012

CONTROLLED CHILLED BEAM PUMP MODULE

ARCTIC EVAPORATIVE COOLING. Direct Evaporative Coolers Indirect Evaporative Coolers Dew Point Evaporative Coolers

TopGas Wall Hung Condensing Gas Boiler

100% Outdoor Air Dehumidification Methods

Best Row Number Ratio Study of Surface Air Coolers for Segmented Handling Air-conditioning System

Appendix 13. Categories of Cooling and Heating systems

SHConDEMAND. True Redundancy. Heating. Cooling. Simultaneous. Efficient. Reliable

SIMULATION ANALYSIS ON THE FRESH AIR HANDLING UNIT WITH LIQUID DESICCANT TOTAL HEAT RECOVERY

Menerga Adconair Various solutions one heat recovery system

Midea VFD Centrifugal Chiller Technology

CONDENSATION/HUMIDITY PROBLEMS IN BREWERIES

The smart handling of liquid chemicals: quickly connected safely dispensed.

Engineering Bulletin Rev B. Contents. Piping Arrangements for Heat Pump Water Heating Systems

Humidity Control Systems for Civil Buildings in Hot Summer and Cold. Winter Zone in China

In Search of the Magic Box: A Review of Crossover Conditioning/Ventilation/Dehumidification Devices on the US Market

edwardsvacuum.com VACUUM PUMPS EOSi ROTARY SCREW PUMP

Product Catalog. Trane Rental Services Temporary HVAC Equipment, Oil-Free Air Compression, and Power Distribution SRV-PRC006B-EN.

Temperature and Humidity Individual Controll HVAC System with the New Desiccant Device DESICA-

CHAPTER 4. HVAC DELIVERY SYSTEMS

VRV The total solution. Integrated Climate Control

APPLICABILITY OF VRV/VRF HVAC SYSTEM A JUDICIOUS AND RATIONAL APPROACH

NEW GENERATION INTELLIGENT CHILLER BOOSTER, ADIABATIC PRE-COOLING SYSTEM

In Search of the Magic Box: A Review of Crossover Conditioning/Ventilation/ Dehumidification Devices on the US Market

Gas condensing boiler (wall mounted) TopGas

Energy Saving Measures for Automotive Air Conditioning (AC) System in the Tropics

CHP INTEGRATION (OR IES): MAXIMIZING THE EFFICIENCY OF DISTRIBUTED GENERATION WITH WASTE HEAT RECOVERY

simatec technologies for plastics industries

Air Conditioning for and-humid Climates:

Heat pump and energy recovery systems

Feasibility of Controlling Heat and Enthalpy Wheel Effectiveness to Achieve Optimal Closed DOAS Operation

COMcheck Software Version Mechanical Compliance Certificate

White Paper Dehumidification in Humid Climates - A Theoretical Case Study

HVAC 101. The Basics of Heating, Ventilation and Air Conditioning

CONTROLLED CHILLED BEAM PUMP MODULE

Impact of Multi-Stage Liquid Desiccant Dehumidification in a Desiccant and Evaporative Cooling-Assisted Air Conditioning System

Solar Liquid Desiccant Air- Conditioning

Transcription:

Novel Liquid Desiccant Systems -For more comfortable and energy efficient air-conditioning applications Breeding a better environment into your building Air T&D Pte. Ltd

Introduction We provide the most energy efficient Liquid Desiccant Dehumidification System (LDDS) and Liquid Desiccant Air-Conditioning (LDAC) on the world market. Through the breakthrough on the design and operation of LDDS & LDAC technologies, our products can achieve 30% to 50% energy savings when applied to residential and commercial building HVAC systems. Our Products LDDS: a series of standard products with single unit air treatment capacities ranging from 500 m3/h to 4,000m3/h. Since the products are modular designed, we can meet all users need through module combination. Our professional design team can also tailor the design for any special requirements from customers. Figure 1 LDDS LDAC: The LDAC are designed for general building HVAC applications to realize independent control of air temperature and humidity, with air flow ranging from 1000 m3/h to 40,000m3/h. LDAC can integrate with existing HAVC components easily to supply cool, dry and clean air into occupied space. Figure 2 Absorption Regenerator

Both LDDS &LDAC have been effectively integrated with the following energy sources: Utilize two-way heat pump to supply cooling and heating energy for dehumidifier and regenerator simultaneously. This integration enables the system to operate independently and is suitable for the application that renewable and cooling energy are not conveniently available. They are very flexible for temporary and mobile dehumidification applications. Integrate the LDDS with existing HVAC systems to employ chilled water and condensation heat as external energy to drive the dehumidifier and regenerator, respectively. The high COP of this integration makes it economically viable in commercial and residential building applications. This integration can also improve the COP of existing chiller plant. Combine the renewable energy and grid power to drive LDDS operation. Our intelligent control technology enables the system to operate in hybrid mode and seek a maximum usage of renewable energy while taking the grid power as an auxiliary. Figure 3 Vertical LDAC Figure 4 Horizontal LDAC Key Innovations Hybrid Operation: In conventional system, desiccant solutions continuously exchange between dehumidification and regeneration columns in order to maintain the pre-specified concentrations. Our patented hybrid operation technology makes the desiccant solutions cycling inside each tower for a specified concentration range, and exchanges the solutions once the limit is reached to avoid the energy waste and improve the system efficiency. Energy Recovery: Conventional systems require a large amount of heat energy for solution regeneration. Most of the heat energy is waste as the regeneration air is discharged directly. Our LDDS & LDAC are able to recurve most of the heat with a heat pipe energy recovery device.

This structure innovation results in 60% regeneration energy saving compared the current technologies. Vacuum Regeneration: High desiccant solution regeneration temperature has been become a key barrier for wide application of LDDS & LDAC. Our novel designed absorption-based liquid desiccant regeneration can drastically reduce the regeneration temperature from 80 C (conventional type) to 40 C, thus most low grade energy, such as solar energy, wasted heat from chiller etc, can be utilized effectively to concentration the desiccant solution. Moreover, no fan is equipped so that the system is energy efficient and more reliable. Intelligent Control: The ability of liquid desiccant to remove water vapor from the air is determined by the temperature, flow rate and concentration of the solution. Air humidity ratio of the dehumidifiers can be controlled by regulating the three variables. We have developed an integrated controller with intelligent control algorithm. Though the advanced control technologies, the humidity ratio of supply air can be accurately controlled from 3gwater/kg dry air to 10gwater/kg dry air. Distributed Operation: In commercial and residential building applications, dehumidifiers are usually inside the AHU rooms located in different floors. The heating sources, either waste heat from chiller or solar energy, are available in plant room or on the roof top. The hybrid operation provides a possibility for dehumidifier and regenerator running in different places which offers an opportunity for LDDS 7 LDAC being efficiently applied in building ACMV systems. Zero Crossover: Our innovative designed on solution Distribution Nozzle and Vane Type Mist Eliminator can achieve both zero solution crossover with minimal pressure drop.

Contact Information Air T&D LTE. LTD Address: 86 Phoenix Garden, Phoenix Heights, Singapore 668336 Phone: 0065-67906538 Fax: 0065-67933318 Website: www.airtd.com.sg Since the founding in Singapore in 2014, Air T&D LTE. LTD. has aimed to be a market leader and supplier in air treatment and distribution technology and providing energy-efficient solutions and services in Southeast Asia. We hope to act as a catalyst to build a more sustainable society and create value for our communities, partners, customers and investors alike and we sincerely hope that our products and services will benefit to you.