COOLING and DE-HUMIDIFICATION WITHOUT USING REFRIGERANTS

Similar documents
Centeral Station Air Handling Unit

Heat pump and energy recovery systems

EU Air Handling Units with SEMCO EXCLU-SIEVE

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

of environmental a product range engineering excellence PR1 ISSUE 2 HEADQUARTERS Dalair Limited Southern Way Wednesbury West Midlands WS10 7BU

1.1 This section applies to air handling units for HVAC Systems.

MECHANICAL SERVICES 101. Ian White

Mystery of Sustainable Heat Exchange Material Heat Recovery Ventilator(HRV)

GUIDE SPECIFICATIONS FOR AIR HANDLING UNITS VENTILATION UNITS & HEAT RECOVERY UNITS

Material and rotor description.

Dehumidification Systems

Heat Recovery Dehumidification (HRD) system. Designed for municipal swimming pools

If a peak space temperature to about 28ºC is acceptable to the occupants then a naturally ventilated solution is a viable option.

Submittal Data Performance Data Electrical Data

ETA ACCU 90% HIGHEST EFFICIENCY AIR HANDLING UNIT

Trane CDQ Desiccant Dehumidification

YMA Air Handling Units

» WITH REGASORP ROTARY HEAT EXCHANGER

The ultimate in air handling units: directly and indirectly fired

PINNACLE SERIES DEDICATED OUTDOOR AIR SYSTEM ENERGY EFFICIENT DEHUMIDIFICATION

The Potential for Solar Powered Desiccant Cooling

Air Handling Units. Real HVACR people who understand your needs.

The ultimate in air handling units: directly and indirectly fired

Evaporative Cooling. HEVAC Association. Humidity Group. an alternative and supplement to mechanical cooling

Comfort and health-indoor air quality

Adsorption Chillers Energysmart Green Cooling

DES CHAMPS PRODUCTS. Specializing in: -- Air-to-Air Energy Recovery -- Conditioning Outdoor Air -- Controlling IAQ -- Indirect Evaporative Cooling

S.A. Klein and G.F. Nellis Cambridge University Press, 2011

EP SERIES PACKAGED ENERGY RECOVERY SYSTEM ENERGY EFFICIENT AIR COMFORT

Easdale International INFINITY

Air is our element. energy recovery our passion. Rotors overview. Quick guide GOST VDI 6022

Solar Heating and Cooling Systems

Menerga Adconair Various solutions one heat recovery system

Rotors overview. Quick guide GOST VDI 6022

Walk in Steam Curing Chamber for Concrete Application. Detailed Working Specifications

TYPICAL CPA SPECIFICATIONS

AFD Industrial Dehumidifier Series

ME Mechanical Engineering Systems Laboratory. Experiment 3 - Mass and Energy Balances in Psychrometric Processes

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

The ultimate in air handling units: directly and indirectly fired

Preliminary Findings on the Performance of a New Residential Solar Desiccant Air-Conditioner

Desiccant Cooling with Solar Energy

Hi-Pres. Self Contained A/C Unit HI-PRES MARINE & OFFSHORE

CHAPTER 4. HVAC DELIVERY SYSTEMS

Principles of Active Desiccant Operation. Presented by Tom Peterson, CEO and Founder. Climate by Design International

AIR HANDLING UNITS. Revision AG 16-07

R07. Answer any FIVE Questions All Questions carry equal marks *****

Chilled Water system

Air handling units KLASIK. Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation

DERV / ERV DEHUMIDIFICATION & ENERGY RECOVERY V E N T I L A T O R U N I T S I N N O V AT I O N W I T H S T Y L E

Operating Performance

Air handling units KLASIK. Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation

SUSPENDED AIR HANDLING UNIT WITH ROTARY HEAT EXCHANGER

Heat Recovery Units. Heat Recovery 1

AIR HANDLER SPECIFICATION

The ultimate in air handling units: directly and indirectly fired

HEATING & COOLING COIL PRODUCTS

SOLAR AIR CONDITONING SYSTEM USING DESSICANTS

Indoor Air Quality. For assured. Double Skin Air Handling Units

Oxyvap Evaporative Cooling Applications

INSTITUTE FOR ENVIRONMENTAL RESEARCH & SUSTAINABLE DEVELOPMENT NATIONAL OBSERVATORY OF ATHENS (NOA)

YMA Custom Air Handling Units

INDUSTRIAL / DOMESTIC WATER HEATERS

LZT High efficiency air to water heat pumps with E.V.I. compressors

GV Standard X-Vent Operation and Maintenance Manual

WORKSHOP VENTILATION- PSYCHROMETRICS-AHU

THE PSYCHROMETRIC CALCULATOR By: Stanley F. Gallos, The Bastian-Blessing Company INTRODUCTION PROPERTIES OF THE RSES CALCULATOR

Bulletin C6200 MAY Buffalo. Big Buffalo. Air Handling. Custom Applications

ENGINEERING & SERVICE

39HQM Central Station Air Handling Units AiroVison Guide Specifications

Adsolair 56/58. Comfort air conditioning unit with double plate heat exchanger and adiabatic evaporative cooling system

TDSHS Air Change Requirements and the Basics of Psychrometrics. Presented by: Aric Murray December 06, 2013

Benefits Offered by Passive Dehumidification Wheel Speed Control

Solar Air-Conditioning and Refrigeration - Introduction

A. Section includes Factory Packaged, Modular units, providing cooling and heating for air distribution systems.

Framework is anodised aluminium with airtight door seals and manual door catches which can be tool locked in position.

Chapter 14 GAS VAPOR MIXTURES AND AIR-CONDITIONING

Enthalpy Wheel and its Application in Air Conditioning

AIR HANDLING UNITS ZHK 2000

Australian Solar Cooling Interest Group (ausscig) Conference

TECHNICAL BULLETIN SELECTING A COMPRESSED AIR DRYER INTRODUCTION

HEAT REGENERATED ADSORPTION DRYERS

Brown Hills College of Engineering & Technology

High Efficiency Compressed Air Dryers. Adsorption Dryers Modular System INTELLIGENT AIR TECHNOLOGY

A. Air Handling Units shall be designed to the specific requirements of the application: Recirculation or 100% Makeup.

K.F. Fong *, C.K. Lee, T.T. Chow

Complete HVAC Capability. Central Station Air Handling Units. Publication No. WT-CSX-0616A

Dehumidification for Industrial Coating Applications. By: Jay Kranker Munters MCS

Air-Handling System Cooling Options

MINI BENCH TOP CHAMBER MODEL: MI-80-A-H

UNIT 1 AIR CONDITIONING 1. Write the various psychometric processes? Explain any four processes with neat sketches?

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

Urbana Free Library HVAC Analysis. Prepared for the Urbana Free Library. Prepared by Paul Boland, P.E., and Nathan Alderman, E.I.T.

Horizontal rotor heat recovery ventilation unit RH 5. Vertical rotor heat recovery ventilation unit RV 9

AIR HANDLING UNITS Vibration Isolation Air Filtration Equipment Ductwork.

ABOUT US OUR EXPERTISE WHAT IS ENERGY RECOVERY? ERV (Energy Recovery Ventilation) AHU (Air Handling Units) PAC (Package Air Conditioning Equipment)

Fans Air handling units Air Distribution Products Fire Safety Air Curtains and Heating Products Tunnel Fans Air Humidifiers For DV Air Handling Units

Appendix 13. Categories of Cooling and Heating systems

PERFORMANCE OF SOLID DESICCANT COOLING WITH SOLAR ENERGY IN HOT AND HUMID CLIMATE

CZT CZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSIONS ACCESSORIES

Transcription:

COOLING and DE-HUMIDIFICATION WITHOUT USING REFRIGERANTS

THE DAWN OF A NEW ERA Political and ecological pressures over the past few years, have led to a change of emphasis in the design of fully air-conditioned buildings. Sick Building Syndrome and the recommended maximum absolute humidity level in occupied buildings, has highlighted the advantages of all fresh air central station plant with full humidity control. Much attention is now being focused on desiccant cooling / de-humidification systems, which can provide a substantial part of a buildings cooling requirements on a central station Air Handling Plant, and allow rigorous control of humidity. This aspect can be most important, not only from a health stand point, but is also vital for successful applications with chilled beams and ceilings THE HEART OF THE SYSTEM. The desiccant cooler is a rotating wheel which is capable of transferring both heat and moisture between the Exhaust and Supply air streams. The matrix is of a honey combe structure, manufactured from silica gel in a special process, offering an extended hygroscopic surface for the adsorption of water vapour. The wheel is constructed in a cassette form with rotating motor and purge section, similar in many ways to the conventional Thermal Wheel. A C P Airconditioning Page 2

Let us Examine the Advantages Desiccant cooling allows control of space humidity level to be maintained plus provides a substantial part of the sensible cooling requirement at summer conditions. The system is ideal for chilled beam or ceiling installations where as well as absolute humidity levels, surface dewpoints must also be strictly controlled to prevent condensation. Energy input for regeneration reaches a peak at summer design conditions. Conveniently available building boiler plant can then be used, without additional capital cost, as boiler output is usually well within the ECO - COOL requirement when selected to satisfy heat demand at winter conditions. It is important to recognise that the largest energy use in U.K installations is for the winter heating cycle. The Eco - Cool system enables a remarkable 85% or more of the sensible heat and moisture to be recovered, drastically reducing heating and humidification costs. A C P Airconditioning Page 3

How Does It Work? Exhaust Side Air returning from the space at (E1) is filtered before passing through a humidifier which increases the moisture content and reduces the db of the air. With the adiabatic cooling process condition (E2) is reached. Exhaust air then passes through a thermal wheel where dry bulb temperature increases (E3), Next the air passes through the regenerator which increases the dry bulb temperature without change in moisture content (E4). The air then enters the desiccant cooler and exchanges energy with the cooler supply air. Moisture is extracted from the supply side and absorbed by the extract air before being rejected to atmosphere (E5). Supply Side Ambient air (S1) is filtered before reaching the desiccant cooler. The moisture content is reduced and dry bulb temperture increased (S2). This warm dry air then exchanges heat with the colder exhaust air (E2) to provide condition (S3). Supply air then passes across a cooling coil where conventional cooling reduces the temperature to (S4). The air is supplied to the space at condition (S5). A C P Airconditioning Page 4

EXAMPLE PSYCHROMETRIC DATA E1 Exhaust air entering AHU 23 C 6.8 g/kg E2 Exhaust air leaving humidifier 15.81 C 9.76 g/kg E3 Exhaust air leaving thermal wheel 37.27 C 9.76 g/kg E4 Exhaust air leaving regeneration heater 70 C 9.76 g/kg E5 Exhaust air leaving desiccant wheel 46 C 16 g/kg S1 Fresh air entering AHU 28 C 11g/Kg S2 Supply air leaving desiccant wheel 44.4 C 6.1 g/kg S3 Supply air leaving thermal wheel 22.9 C 6.1 g/kg S4 Supply air leaving cooling coil 15 C 6.1 g/kg S5 Supply condition 16.5 C 6.1 g/kg A C P Airconditioning Page 5

DIMENSIONS MODEL MAX AIR VOL M3/S H W L REFERENCE ACEC 95 0.8 1150 1150 5000 ACEC114 1.3 1350 1350 5000 ACEC131 1.7 1500 1500 5000 ACEC146 2.2 1670 1670 5400 ACEC162 2.7 1850 1850 5400 ACEC203 4.4 2200 2200 5400 ACEC254 7.1 2900 2900 5700 ACEC304 10.3 3300 3300 6500 ACEC370 14.8 3900 3900 7000 Additional cooling available; Chilled Water or DX. Regenerative heat source options; LPHW, Steam, Electric, Gas or Oil Filtration options; EU3 to EU14 Controls options; Full air side and power controls, built in packages available A C P Airconditioning Page 6

The component parts of any full ECO - COOL package are standard from our range of CONSORT 2000 Advanced Air Handling Equipment, for full technical description of individual elements, please refer to publication Consort 2000. 1. Desiccant Cooler. The principle component in the ECO - COOL system is the desiccant cooler. Essentially this consists of a rotating wheel within a metal housing, with central drive shaft, motor and bearings. This arrangement provides a huge extended surface of hygroscopic and thermal storage material to the air flow. Extract and supply air streams pass in opposite directions through each half of the wheel, with a purge sector incorporated, and the rate of heat and moisture transfer can be controlled by the speed of rotation, and regeneration temperature adjustments. 2. Thermal Wheel. This component of the ECO - COOL system provides the means of transferring heat energy between the extract and supply air streams. It is similar in construction to the desiccant wheel. The thermal wheel also consists of a central drive shaft, motor and bearings. The core of the wheel is constructed of alternative layers of plain and corrugated aluminium, with supply and extract air streams passing in opposite directions through each side of the wheel. A purge sector is included and the rate of heat transfer is regulated by controlling the speed of operation. 3. Humidifier. A basic component of the ECO - COOL system is the adiabatic cooling of the supply air by the extract air. The humidifier consists of water sprayed onto, or trickling down, an extended surface positioned across the exhaust air stream. The close contact causes 85% or more saturation to be achieved, at the same time reducing the dry bulb temperature. The humidifier contains drain tray, circulating pump and spray pipework system, necessary for certain duties and applications. A C P Airconditioning Page 7

CABINET SPECIFICATION. FRAMEWORK: Each AHU or AHU section is fabricated with a framework of 50mm extruded aluminium boxed section with die cast aluminium or nylon corner joints and accessories. OPTIONS: Anodised finish, nylon corners and accessories, extensions for valves, bulkhead lights wired to outside switch, enclosures for control panel, enclosure with internal walkway (on larger units). ACCESS PANELS: Panels secured in place by compressive hand operated locks. Complete with pull-off grips or grab handles (depending on panel size). OPTIONS: Lift off doors, hinged doors, tool operated lockable handle, key operated lockable handle, single half turn compressive hand operated latch, double handle with internal release, inspection windows, electrical interlock switches fitted. PANELS: The frame is clad with 25mm thick double skinned insulated panels, which fit into the rebated edges of the corner or intermediate section, to form a continuous flush surface. Minimum metal thickness is 0.9mm and outer skin is plasticised steel sheet. Inner skin is self-finish galvanised steel sheet. Standard colour finishes are available. All access panels are sealed against framework with rubber gasket. On 50mm framing, a tubular rubber gasket can be mechanically fitted to a preformed groove in the section for extra quality seal. OPTIONS: 50mm panel thickness, increased metal skin thickness, range of alternative colour finishes, range of acoustic constructions - high density board, perforated inner skin, septum plates, thicker panel skins, etc. INSULATION: 25mm thick mineral wool slab, minimum density 45 Kg/m3 EXTRAS: High density acoustic infill. BASES: Each AHU (or AHU section) is normally fitted underneath with a base frame. After fabrication the base is cleaned, primed and finished in black hammerite paint or anodised on aluminium bases. EXTERNAL AHU: Fitted with pitched weather roof overhung all round as standard. All fixed panels mastic sealed in place and additional gaskets used on removable panels. PRESENTED BY