SYSTEM Inverter Air Conditioners

Similar documents
OPERATION MANUAL. SYSTEM Inverter Air Conditioners FXSQ36MVJU FXMQ36MVJU FXSQ48MVJU. MODELS Ceiling-mounted Duct type. Ceiling-mounted Built-in type

SYSTEM Inverter Air Conditioners

SYSTEM Inverter Air Conditioners

SYSTEM Inverter Air Conditioners

SPLIT SYSTEM Air Conditioners

OPERATION MANUAL. Split system air conditioners FHYBP71B8V1 FHYBP100B8V1 FHYBP125B8V1 FHYCP71B8V1 FHYCP100B8V1 FHYCP125B8V1

Operation manual. Split system air conditioners FDXM25F3V1B FDXM35F3V1B FDXM50F3V1B FDXM60F3V1B. Operation manual Split system air conditioners

OPERATION MANUAL. System air conditioners FXAQ15AUV1B FXAQ20AUV1B FXAQ25AUV1B FXAQ32AUV1B FXAQ40AUV1B FXAQ50AUV1B FXAQ63AUV1B

OPERATION MANUAL. Split system air conditioners FCQG35FVEB FCQG50FVEB FCQG60FVEB FCQG71FVEB FCQG100FVEB FCQG125FVEB FCQG140FVEB

OPERATION MANUAL. Air Conditioners FXAQ20PV1 FXAQ25PV1 FXAQ32PV1 FXAQ40PV1 FXAQ50PV1 FXAQ63PV1. MODELS Wall-mounted type. English. Deutsch.

Wireless Remote Controller Kit

OPERATION MANUAL. SYSTEM Inverter Air Conditioners FXAQ15PAV1 FXAQ20PAV1 FXAQ25PAV1 FXAQ32PAV1 FXAQ40PAV1 FXAQ50PAV1 FXAQ63PAV1

OPERATION MANUAL. VRV Classic System air conditioner RXYCQ8A7Y1B RXYCQ10A7Y1B RXYCQ12A7Y1B RXYCQ14A7Y1B RXYCQ16A7Y1B RXYCQ18A7Y1B RXYCQ20A7Y1B

OPERATION MANUAL. SYSTEM Inverter Air Conditioners

DAIKIN ROOM AIR CONDITIONER. Operation Manual

DAIKIN ROOM AIR CONDITIONER. Operation Manual. English. Deutsch. Français. Nederlands. Español. Italiano. Ελληνικά. Portugues. Русский.

OPERATION MANUAL. Split system air conditioners FDYP125B8V1 FDYP200B8V1 FDYP250B8V1 FDQ125B8V3B FDQ200B8V3B FDQ250B8V3B

SPLIT SYSTEM Air Conditioners

KSD-35 DR11 KUE-35 DVN11

Owner s Manual Super-Slim Four-Way Cassette

SPLIT SYSTEM Air Conditioners

Owner s Manual. Middle Static Pressure Duct Type MEU-18MPH2 MEU-24MPH2 MEU-36MPL2 MEU-48MPL2 MIDDLE STATIC PRESSURE DUCT TYPE AIR CONDITIONER

SLIM CASSETTE TYPE AIR CONDITIONER OWNER S MANUAL

Operation manual. Split system air conditioners FBA35A2VEB FBA50A2VEB FBA60A2VEB FBA71A2VEB FBA100A2VEB FBA125A2VEB FBA140A2VEB

DUCTED AIR CONDITIONER. Owner s Manual. KD Series KD24. Kaden Owner s Manual 1

OWNER S MANUAL KPD-105 DTN11 KPD-140 DVN11 KPD-140 DTN11 KPD-160 DTN11 KPD-52 DVR11

OPERATION MANUAL. System air conditioner

WINDOW TYPE COOLING MODEL AKT7F AKT9F REVERSE CYCLE MODEL AKT7U AKT9U FUJITSU GENERAL LIMITED

OPERATION MANUAL FAQ18PVJU FAQ24PVJU. MODELS (Wall mounted type)

OPERATION MANUAL. Split series room air conditioners Multi system room air conditioners FDBQ25B7V1

OPERATION MANUAL. Split series room air conditioners Multi system room air conditioners FDBQ25B7V1

OPERATION MANUAL. System Inverter Air Conditioners FXNQ20A2VEB FXNQ25A2VEB FXNQ32A2VEB FXNQ40A2VEB FXNQ50A2VEB FXNQ63A2VEB

Operation Manual. Before use. Before use. Operation. Operation. Maintenance. For Your Information. Use smart and save smart DCS601C71

English DAIKIN ROOM AIR CONDITIONER OPERATION MANUAL. Français. Español MODELS FTXS09LVJU FTXS12LVJU CTXS07LVJU

Bosch Split-Type Ductless Air Conditioner / Heat Pump

General safety precautions English

NEXXOS INVERTER USER MANUAL

AIR CONDITIONER. Please read this owner, s manual carefully before using the air conditioner, and keep this manual for the future reference.

INVERTER ONE-TWO/ONE-THREE/ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER

Owner s Manual INVERTER ONE-TWO/ONE-THREE /ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER

Owner s Manual INVERTER ONE-TWO/ONE-THREE /ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER

Inverter Split-type Room Air Conditioner

CDKD25CVM CDKD35CVM Operation Manual

OPERATION MANUAL. MODELS Ceiling mounted cassette type (Round flow model)

Middle Static Pressure Duct Type

DAIKIN ROOM AIR CONDITIONER MODELS CDXS25EAVMA CDKS25EAVMA CDXS35EAVMA CDKS35EAVMA. Operation Manual

Owner s Manual CS

Table of Contents SAFETY FIRST. Owner s Manual. Safety Precautions Unit Specifications and Features Manual Operation (Without Remote)...

General safety precautions English

General safety precautions English

Owner s Manual. Fairwind Series All Model Numbers SPLIT-TYPE ROOM AIR CONDITIONER CS

FLOOR & CEILING SERIES

General safety precautions English

Operating Instructions Air Conditioner

MULTI-SPLIT SYSTEM AIR CONDITIONER / HEAT PUMP. YN-M Series. Inverter++ Models. Two, Three, Four, and Five Zones (Dual, Triple, Quad, and Quint Multi)

English DAIKIN ROOM AIR CONDITIONER OPERATION MANUAL. Français. Español MODELS FDXS09LVJU FDXS12LVJU CDXS15LVJU CDXS18LVJU CDXS24LVJU

AH-PNX11 AU-PNX11 AH-PNX14 AU-PNX14 EN-1 SPLIT TYPE ROOM AIR CONDITIONER OPERATION MANUAL ENGLISH

CENTRAL REMOTE CONTROLLER

OPERATION MANUAL DAIKIN ROOM AIR CONDITIONER MODELS

WIRED REMOTE CONTROLLER

USER S MANUAL AQV09V A Series AQV12V A Series AQV18V A Series AQV24V A Series

INSTALLATION AND OPERATION MANUAL

OPERATION MANUAL. MODELS Ceiling mounted cassette type (Round flow model) FCQN140KVEA FCQN125KVEA

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference.

Utopian Split A/C. Thank you for purchasing this quality Split A/C system!

CPG*CA CPG*CD CGC*CA CGC*CD CIM*CA CIM*CD CPP*CA CPP*CD

OPERATION MANUAL. MODELS (Ceiling-mounted Multi flow Cassette type) FFQ25BV1B FFQ35BV1B FFQ50BV1B FFQ60BV1B

X-POWER Full DC Inverter Outdoor Unit

Washing Machine. User manual WW9*K5*****/WW8*K5*****/WW7*K5***** Untitled :17:40

Air conditioner. User manual AC777KN4DCH

OPERATING MANUAL AIR CONDITIONER CASSETTE TYPE. AUT Series KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N

INDOOR UNIT/OUTDOOR UNIT

Owner s Manual SPLIT-TYPE ROOM AIR CONDITIONER

FLOOR CONSOLE/ UNDER CEILING DUAL TYPE. ABT Series FUJITSU GENERAL LIMITED AIR CONDITIONER OPERATING MANUAL P/N

Wireless Remote Controller Kit

SPLIT TYPE. Instruction manual

Indoor Unit (2 Series)

INDOOR UNIT/OUTDOOR UNIT

DAIKIN ROOM AIR CONDITIONER. Operation Manual ATXD60CV4 ATXD71CV4 ATXD80CV4

GDDEM10 DEHUMIDIFIER

INDOOR UNIT/OUTDOOR UNIT

General safety precautions English

Operation Manual MODELS FTYN25DV3B FTN25DV3B FTYN35DV3B FTN35DV3B FTYN25DAV3B FTN25DAV3B FTYN35DAV3B FTN35DAV3B DAIKIN ROOM AIR CONDITIONER.

OPERATION MANUAL FTQ18PBVJU FTQ24PBVJU FTQ30PBVJU FTQ36PBVJU FTQ42PBVJU. MODELS Air Handling Unit

OPERATION MANUAL. Wireless Remote Controller Kit

INDOOR UNIT/OUTDOOR UNIT

General safety precautions English

Indoor Unit :FPA-18 FPA-24 FPA-36DU FPA-48DU Outdoor Unit :CPP018CD(O) CPP024CD(O) CPP036CD(O)-DU CPP048CD(O)-DU

OPERATION MANUAL DAIKIN ROOM AIR CONDITIONER

15,000 BTU Portable Air Conditioner

INDOOR UNIT/OUTDOOR UNIT

This air conditioner comprises an indoor unit, outdoor unit, and a connection pipe.

OWNER S MANUAL COMPLETE VRF OUTDOOR UNIT

R410A SPLIT SERIES FIXED SPEED

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference.

Operating Instructions

Middle Static Pressure Duct Type

INDOOR UNIT/OUTDOOR UNIT

INDOOR UNIT/OUTDOOR UNIT

INSTALLATION MANUAL. Decoration Panel Provided with Filter Auto Cleaning Function Self Cleaning decoration panel BYCQ140D7GW1 BYCQ140D7GFW1

Transcription:

OPERATION MANUAL SYSTEM Inverter Air Conditioners MODELS Ceiling-mounted Cassette type (Multi flow model) FXFQ12MVJU FXFQ18MVJU FXFQ24MVJU FXFQ30MVJU FXFQ36MVJU Read these instructions carefully before installation. Keep this manual in a handy place for future reference. This manual should be left with the equipment owner.

SAFETY CONSIDERATIONS Please read these SAFETY CONSIDERATIONS carefully before installing air conditioning equipment and be sure to install it correctly. After completing the installation, make sure that the unit operates properly during the start-up operation. Please instruct the customer on how to operate the unit and keep it maintained. Also, inform customers that they should store this operation manual along with the installation manual for future reference. This air conditioner comes under the term appliances not accessible to the general public. Meaning of warning, caution and note symbols. WARNING...Indication a potentially hazardous situation which, if not avoided, could result in death or serious injury. CAUTION...Indication a potentially hazardous situation which, if not avoided, may result in minor or moderate injury. It may also be sued to alert against unsafe practices....indication situation that may result in equipment or property-damage-only accidents. Keep these warning sheets handy so that you can refer to them if needed. Also, if this equipment is transferred to a new user, make sure to hand over this operation manual to the new user. WARNING It is not good for your health to expose your body to the air flow for a long time. In order to avoid electric shock, fire or injury, or if you detect any abnormality such as smell of fire, turn off power and call your dealer for instructions. Ask your dealer for installation of the air conditioner. Incomplete installation performed by yourself may result in a water leakage, electric shock, and fire. Ask your dealer for improvement, repair, and maintenance. Incomplete improvement, repair, and maintenance may result in a water leakage, electric shock, and fire. The refrigerant in the air conditioner is safe and normally does not leak. If the refrigerant leaks inside the room, the contact with a fire of a burner, a heater or a cooker may result in a harmful gas. Do not use the air conditioner until when a service person confirms to finish repairing the portion where the refrigerant leaks. For refrigerant leakage, consult your dealer. When the air conditioner is to be installed in a small room, it is necessary to take proper measures so that the amount of any leaked refrigerant does not exceed the limiting concentration even when it leaks. If the refrigerant leaks exceeding the level of limiting concentration, an oxygen deficiency accident may happen. Improper installation or attachment of equipment or accessories could result in electric shock, short-circuit, leaks, fire or other damage to the equipment. Be sure only to use accessories made by Daikin which are specifically designed for use with the equipment and have them installed by a professional. Ask your dealer to move and reinstall the air conditioner. Incomplete installation may result in a water leakage, electric shock, and fire. Never let the indoor unit or the remote controller get wet. It may cause an electric shock or a fire. Never use flammable spray such as hair spray, lacquer or paint near the unit. It may cause a fire. Never replace a fuse with that of wrong ampere ratings or other wires when a fuse blows out. Use of wire or copper wire may cause the unit to break down or cause a fire. Never remove the fan guard of the unit. A fan rotating at high speed without the fan guard is very dangerous. Never inspect or service the unit by yourself. Ask a qualified service person to perform this work. To prevent refrigerant leak, contact your dealer. When the system is installed and run in a small room, it is required to keep the concentration of the refrigerant, if by and chance coming out, below the limit. Otherwise, oxygen in the room may be affected, resulting in a serious accident. Cut off all electric waves before maintenance. To avoid the risk of serious electrical shock, never aprinkle or spill water or liquids on the unit. Do not install the air conditioner at any place where flammable gas may leak out. If the gas leaks out and stays around the air conditioner, a fire may break out. Do not touch the switch with wet fingers. Touching a switch with wet fingers can cause electric shock. CAUTION Do not use the air conditioner for other purposes. In order to avoid any quality deterioration, do not use the unit for cooling precision instruments, food, plants, animals or works of art. To avoid oxygen deficiency, ventilate the room sufficiently if equipment with burner is used together with the air conditioner. After a long use, check the unit stand and fitting for damage. If they are left in a damaged condition, the unit may fall and result in injury. Do not allow a child to mount on the unit or avoid placing any object on it. Falling or tumbling may result in injury. Do not let children play on and around the unit. If they touch the unit carelessly, it may result in injury. Do not place a flower vase and anything containing water. Water may enter the unit, causing an electric shock or fire. 2 English

Never touch the internal parts of the controller. Do not remove the front panel. Some parts inside are dangerous to touch, and a machine trouble may happen. For checking and adjusting the internal parts, contact your dealer. Avoid placing the controller in a spot splashed with water. Water coming inside the machine may cause an electric leak or may damage the internal electronic parts. Do not operate the air conditioner when using a room fumigation - type insecticide. Failure to observe could cause the chemicals to become deposited in the unit, which could endanger the health of those who are hypersensitive to chemicals. Do not put a finger, a rod or other objects into the air inlet or outlet. As the fan is rotating at high speed, it will cause injury. Do not touch the heat exchanger fins. Improper handling may result in injury. Safely dispose of the packing materials. Packing materials, such as nails and other metal or wooden parts, may cause stabs or other injuries. Tear apart and throw away plastic packaging bags so that children will not play with them. If children play with a plastic bag which was not torn apart, they face the risk of suffocation. Do not turn off the power immediately after stopping operation. Always wait at least five minutes before turning off the power. Otherwise, water leakage and trouble may occur. The appliance is not intended for use by young children or infirm persons without supervision. The remote controller should be installed in such away that children cannot play with it. Dismantling of the unit, treatment of the refrigerant, oil and eventual other parts, should be done in accordance with the relevant local and national regulations. Do not dry the filter by exposing it to direct sunlight or warming it using fire, etc. Doing so can result in the deformation of the filter. Never touch the air outlet or the horizontal blades while the swing flap is in operation. Fingers may become caught or the unit may break down. Never press the button of the remote controller with a hard, pointed object. The remote controller may be damaged. Never pull or twist the electric wire of the remote controller. It may cause the unit to malfunction. Do not place appliances which produce open fire in places exposed to the air flow from the unit or under the indoor unit. It may cause incomplete combustion or deformation of the unit due to the heat. Arrange the drain hose to ensure smooth drainage. Incomplete drainage may cause wetting of the building, furniture etc. Do not place the controller exposed to direct sunlight. The LCD display may get discolored, failing to display the data. Do not wipe the controller operation panel with benzine, thinner, chemical dustcloth, etc. The panel may get discolored or the coating peeled off. If it is heavily dirty, soak a cloth in water-diluted neutral detergent, squeeze it well and wipe the panel clean. And wipe it with another dry cloth. English 3

MAINTENANCE HOW TO CLEAN THE AIR FILTER Clean the air filter when the display shows (TIME TO CLEAN AIR FILTER). Increase the frequency of cleaning if the unit is installed in a room where the air is extremely contaminated. (As a yardstick for regulating yourself, consider cleaning the filter once a half year.) If the dirt becomes impossible to clean, change the air filter. (Air filter for exchange is optional) 2. Remove the air filter. Pull the air filter clips downward at an angle to detach the filter. 1. Open the suction grille. Slide the latches ( 2) outward to the side and carefully lower the grille. (Do the same procedure for closing.) 4 English

3. Clean the air filter. Use vacuum cleaner A) or wash the air filter with water B). A) Using a vacuum cleaner (Do not use air of 120 F or higher) HOW TO CLEAN THE SUCTION GRILLE 1. Open the suction grille. Slide the latches ( 2) and carefully lower the grille. (Do the same procedure for closing.) B) Washing with water To clean the air filter, use soft brush and neutral detergent. (Do not use water of 120 F or higher) Remove water and dry in the shade. 2. Remove the air filter. Refer to HOW TO CLEAN THE AIR FILTER. 3. Detach the suction grille. Open the suction grille 45 degrees and lift it upward. 4. Fix the air filter. 1. Hook the air filter on the projections at the top of the suction grille. 2. Press the bottom of the air filter against the projections on the bottom of the grille to snap the air filter into place. 4. Clean the suction grille. Wash with a soft bristle brush and neutral detergent or water, and dry throughly. 5. Shut the suction grille. Refer to item No. 1. 6. Press the FILTER SIGN RESET BUTTON on the remote controller. The display (TIME TO CLEAN AIR FILTER) vanishes. (For details, see the operation manual for the outdoor unit.) Do not remove the air filter except when cleaning. Unnecessary handling may damage the filter. When badly soiled, spray with a typical kitchen cleanser and let sit for about 10 minutes. Then, wash with water. 5. Reattach the suction grille. Refer to item No. 3. 6. Fix the air filter. Refer to HOW TO CLEAN THE AIR FILTER. 7. Close the suction grille. Refer to item No. 1. HOW TO CLEAN AIR OUTLET AND OUTSIDE PANELS Clean with soft cloth. When it is difficult to remove stains, use water or neutral detergent. Do not use gasoline, benzene, thinner, polishing powder, liquid insecticide. It may cause discoloring or warping. Do not let the indoor unit get wet. It may cause an electric shock or a fire. English 5

MEMO 6

Daikin US Corporation 375 Park Avenue, Suite 3308 New York, NY 10152 www.daikinac.com info@daikinac.com 3PN02401-6N EM03A039B (0403) HT