High-Performance Bolt Heaters

Similar documents
Screw plug immersion heaters

Flange immersion heaters

Industrial Cast-in Circulation Heaters for ATEX/IECEx hazardous areas or in non-atex version

Defrosting. Flexible Heating Elements. DEFA, DEFB, DEFC range. Straight annealed elements adaptable for evaporators or tray defrosting, DEFA range

Electric Air Heating Standard product ranges

Immersion heaters for ATEX/IECEx hazardous areas or in non-atex version

Duct heaters for ATEX/IECEx hazardous areas or in non-atex version

Circulation heaters for ATEX/IECEx hazardous areas or in non-atex version

Condair Esco. Steam humidification system INSTALLATION INSTRUCTIONS EN 1310

Tubular Heaters Series

HERZ-DR-T-90. Radiator Control Valves with Pre-Setting Function by Means of Double Cone, Suitable for Conversion to Thermostatic Operation. H max.

BRINGING WARMTH TO YOUR WORLD

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

The heart of electric appliances ELECTRIC WATER HEATING MADE IN ITALY

BAND HEATERS. This technology is suitable for different industrial heating applications : Sealed mica band heaters

INSTALLATION GUIDELINES

Manifold Cleaning and System Refurbishment...N3 Nozzle Heater and Hot Runner Component Repair...N4

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

DURA RIMP. Goodall Duracrimp coupling system: INFERNO ISO A and SUPER INFERNO. A safe crimping connection for our GOODALL steamhoses

Model: 1100 Float-Controlled Condensate Trap, PN 25

Machine needle shut-off nozzle type-s

EXPANSION JOINT PRODUCTS

1 of 12. Goldvent Marketing Sdn. Bhd. Immersion Heaters with Control. Temperature Controller, SSR Process Control Panels

Strip/Clamp-On Heaters

Tubular Heaters and Heating Elements

INSTALLATION AND OPERATING INSTRUCTIONS GN2. HIGH EFFICIENCY CAST IRON BOILER FOR LIQUID and/or GAS FUELS

Differential Pressure and Flow Meter. Media 5 Indicator 160 Ø PN 50

Operating Manual. Model: Float-Controlled Condensate Trap, PN Safety instructions. 2 General description and usage

Heated tools. Semiconductor equipment

IRmax & IREX accessories

AZN ATEX INSTALLATION AND MAINTENANCE

Water mist nozzles With anti-drip

Semi-Automatic Suction Screen Filters 3"-4 Angle. Service & Maintenance Manual

ISO9001:2008 Cert Certified FIRE HYDRANTS. since SFFECO

Mineral Insulated Band Heater

Machine needle shut-off nozzle Type SHP (high performance) spring operated

STRAIGHT & FORMED TUBULAR HEATERS

infranomic INFRARED HEATING PANELS Operating and Installation Instructions Wolff+Meier GmbH & Co. KG Glaswerke Am Wingert Langgöns Germany

Installation Instructions

HEATING ELEMENTS FOR WATER HEATING output 500W W water and similar liquid heating

Model: 1200 Model: 1200-G Model: 1200-N Float-Controlled Condensate Trap, PN 40

Pro-Clean Stratified Tank scope of delivery:

Industrial Heaters for Plastic Applications

Installation guide PRO3. Before installing read this guide first

For our present, For their future. Version 11.04

Safety vacuum drying oven for flammable solvents

Design and manufacture of agitators since INSTALLATION MANUAL Start-up and maintenance. Top-entry agitators

CYLINDER PLASTICS CERAMIC BAND HEATERS. Main technical characteristics: Mechanics. Electrics

Cartridge Heaters. Metric FIREROD Cartridge. Applications and Technical Data

FALSE CEILING KIT FOR MAJOR PRO-C INSTRUCTION MANUAL

Plate Coil Heat Exchangers

LOW PRESSURE SYSTEM INSTALLATION GUIDE

C 9000 Polymer Quick-Acting Safety Coupler Range

Integrated Process Solutions. Series 48 Heaters. heater jackets sizes 1 1/2'' to 4'' (nw 40 to nw 100)

Heat on. Air heaters. Blowers. from 400 Watt to Watt. from 1,45 m 3 /min to 16,5 m 3 /min

nr. 4 Ø64 RECEIPT OF PRODUCT The convector is supplied in two cardboard packages: - Convector - Fume exhaust and combustion air inlet pipes.

Safe, abundant supply of hot water on board!

Band Heaters W A T L O W. Special Mica Barrel and Nozzle

Lowara ecocirc and ecocirc PREMIUM THE NEW HIGHLY EFFICIENT CIRCULATORS WITH THE PATENTED ANTI-BLOCK-TECHNOLOGY

Temperature Sensor TRG Original Installation Instructions English

HERZ-Thermostatic and Return Valves. DE LUXE Edition 1000 (0999) HERZ Armaturen. Standard Sheet for DE LUXE. Richard-Strauss-Straße 22 A-1230 Wien

Quality Heat Exchangers

AVANI Grinding Booth

CAP SERIES SEWAGE AND WASTE WATER PUMPS

INTRODUCTION: COOLING TOWER INTRODUCTION: COOLING TOWER FANS. The cooling Tower is commissioned since 2006 and 1 st failure was encountered in 2007

THERMOSTATIC EXPANSION VALVES AND THERMOSTAT CONTROL DEVICES

Excellent Engineering Solutions. Solids Handling Pumps. Recessed Vortex Impeller Pumps CLEAR LIQUID

Integrated Process Solutions. Series 46 Heaters HEATER JACKETS FOR STAINLESS STEEL PIPING SIZES 1 1/2 TO 4 (NW 40 TO NW 100)

Pro-MAX Ultraviolet Sterilizer

MEGAWAT * HIGH DENSITY CARTRIDGE HEATERS

AUTOMATIC POOL COVER. Serial number: ENGLISH MANUAL N'CARLIT MODEL INSTALLATION MANUAL AND MAINTENANCE. 0/15 Revison n

Nozzle Band Heaters. Construction Characteristics. Single Port Igloo TM Covers

OWNER S MANUAL LOW-POWER SCREW-IN AND FLANGE-MOUNTED IMMERSION HEATERS (MAXIMUM 3 PINS)

Installation Operation Maintenance

GRINNELL Rapid Installation Pivot-Bolt

Fuel Manager Diesel Fuel Filtration. FM1, FM10, FM100 and FM1000 Complete Systems, Elements and Service Parts

Sinus Jevi (Explosion-Proof) Condens Heaters

Micro/Ultra Filtration System StamoClean CAT 430

Electronic Standard Devices. Annunciator Relay. MR 11 and MRE 11 MR 21 and MRE 21

Agency Certifications, Recognition and Approvals

Technical Data. Sizes 2 in. (DN50) to 16 in. (DN400) Approvals UL and ULC Listed FM Approved

Dräger Polytron SE Ex Fixed Gas Detector

DLKF. EBARA Submersible Sewage Pumps Specifications Project: Model: Chk d: Date:

Quality Heat Exchangers

PIROWATT - High Power Cartridge Heaters -

CRYOGENIC EXPERTS, INC. World Wide Web Toll Free FOR CEXI Phone (805) Facsimile (805)

SERVICE MANUAL. 300 Series Motorized 35650, 35651, 35652, 36750, 36751, and Model

Operating Manual. Model: 1400 Model: 1400-N RIFOmat Float-Controlled Condensate Traps, PN Safety instructions. 2 General description and use

Pumps Mixers Aeration Controls Services SCANPUMP SPLIT CASING PUMP Z22.

Cartridge/Insertion Heaters

HORIZONTAL MULTISTAGE CENTRIFUGAL PUMP

Manual Wöhler Rotary Viper Vent M 10

Sintrol Snifter A1+ Manual. Version 1.2.2

NON-SLAM DYNAMIC ARV FAF 7330

INSTALLATION INSTRUCTIONS John Deere One Series; 1023E, 1025R and 1026R Models A HEATER KIT. Figure 1 (General Layout and Parts I.D.

Rev Installation Guide. Sondex Industrial and Marine Pumps

Camaro A/C Install Instructions

Hydronic Heating Fan Coils Radiant ceiling systems Water Source Heat Pumps Alumline Radiant Heating and Cooling Ceiling Panels

STEAM TRAPS

Transcription:

High-Performance Bolt Heaters Boron Nitrid Technology TIGHTENING / UNTIGHTENING OF DRILLED BOLTS THROUGH THERMAL EXPANSION Smaller equipment Less space, weight, heat loss, cost saving, reduced thermal inertia Increased Productivity More heat in less time for shorter production cycles High Temperature Longer heater life in extreme conditions, very high temperatures Power control panels and connecting cables available on demand www.cetal.com www.cetal.com - Tel.: +33 3 88 06 19 49 - E-mail: contact@cetal.fr

CETAL bolt heaters reduce the nut tightening and untightening time by heating while improving the safety of operators and heated material. High performance through boron nitrid insulation The use of boron nitrid as insulation allows to concentrate a lot of energy in a small space. The power is transmitted by radiation. With this technology, high temperatures can be obtained in a short time, thus reducing to a few minutes the nut tightening/untightening time. Applications Tightening/untightening of drilled bolts through thermal expansion Maintenance of turbine engines Advantages Very short heating time Heating to approx. 350 C (depending on the bolt material) Easy handling - one operator per machine - one power outlet per bolt heater Significantly reduces the assembling/ deassembling time of large forged and cast-iron parts Capacity to heat only the central part of the bolt Long lifetime: 10 000 cycles Workstation safety through low voltage < 50 V Industrial sectors Shipyards Thermal power stations Metallurgy... Design The bolt heaters are designed according to specifications using standard tube diameters. Lenght and power are defined according to the bolt to be heated (size, Ø of drilling, mounting tolerance). The bolt heaters can be supplied with 24 V (BT plug), 110 V, 230 V or other voltage. The heating part of the bolt heaters is indicated through small machined grooves. To avoid incorrect installation, a positioning ring helps identifying the active zone. The CETAL expertise After customer specification analysis, our engineers will drive you to the best solution for your process. 2 www.cetal.com - Tel.: +33 3 88 06 19 49 - E-mail: contact@cetal.fr

Bolt heater application Tightening through thermal expansion Assembling Heating Tightening Cooling Dilatation Expansion Main advantages of Boron Nitrid technology Temperature gradient improved by 10 compared to Magnesia Heating 100% homogeneous (Straight wire) Medium voltage No leakage current at high temperature Boron Nitrid heating elements are smaller and lighter: they save space and are easy to handle Insulation: Boron Nitrid Connecting terminals Tube sheath Resistance wire (80/20) Benefit from the CETAL advantages! Design and manufacturing experts since 50 years! Calculation and design tools specifically developed for industrial heating applications End-to-end control of design and production chain for products which suit your process perfectly Benefit from the CETAL know-how to optimize your process and reduce costs! www.cetal.com - Tel.: +33 3 88 06 19 49 - E-mail: contact@cetal.fr 3

4 3 4 9 8 B A Ø7 ØC Design of your bolt heater 9 Input data Bolt material, ideally incl. specific heat and expansion coefficient Thinned length of the bolt (A) Length of bolt end (B) Bolt drilling diameter (C) Outer diameter of the thinned length (D) Straight or angled? Power (W) Voltage (V) 1PH or 3PH Supply, connecting box Total length (including 30-40 mm cold length) Power control panel and cables? (please specify the cable length) CETAL thermal design and offer Design procedure to optimize your product 1. Power 2. Voltage 3. Heating length 4. Cold length 5. Total length 6. Watt density (W/cm²) 7. Material / Tube diameter 8. Positioning ring 9. Type of plug or connecting box 10. Power control panel 11. Cables 12. Quotation: price and delivery time 10 ØD 11 4 www.cetal.com - Tel.: +33 3 88 06 19 49 - E-mail: contact@cetal.fr

Données techniques Tube materials Inox AISI 316L (1.4404) Others on request Tube / bolt diameters (mm) Ø bolt heater Ø H11 bolt 10.70 11 11.70 12 12.20 12.5 15.70 16 17.70 18 19.70 20 21.65 22 24.60 25 25.60 26 29.60 30 Other diameters on request Electrical Voltage: VAC or VCC Cabling according to main voltage VAC/VCC 1PH + N or 3PH Power: < 10 000 W (higher on request) Standard documentation EU Certificate of Compliance Instruction manual On-request documentation Certificate of conformity to the order Supplied according to directives and standard Material certificate 3.1 acc. to NF EN 10204 Certifications (if requested) According to standard to comply with EAC CU&TR Options Detachable cable (except for box filled with resin) Other connection boxes on request Power control panels - Power 5, 10, 15, 20 KVA - 24 V / 48 V, primary 230 V or 400 V - 110 V / 230 V on request Connection / Connection box 24 V or 48 V plug - Female aluminum plug - Male plug, plastic, with cable - Thermal grease Box filled with resin, 230-400 V - With HO7RNF or silicone cable - Thermal grease Box with handle, 230-400 V - With or without LED - With HO7RNF or silicone cable - Thermal grease Other connection boxes on request (e. g, RATEAU connection box), can be supplied with simple threaded rods www.cetal.com - Tel.: +33 3 88 06 19 49 - E-mail: contact@cetal.fr 5

Design and manufacturing of electrical heating equipment for your industrial process for use in ATEX/IECEx harzardous areas or in non-atex version All CETAL products can be adapted to your specifications. Contact us! Flange immersion heaters Screw plug immersion heaters Removable immersion heaters Circulation heaters Cast line heaters Air duct heaters Industrial convectors Formed elements www.cetal.com Cast elements Ribbed heaters New! Anti-condensation heating elements Power control panels Standard range Bolt heaters 42 rue des Aviateurs BP 20037 F67501 HAGUENAU CEDEX France - Tel.: +33 3 88 06 19 49 - Fax: +33 3 88 06 19 30 - E-mail : contact@cetal.fr 2017 CETAL Sous réserve de modifications, d erreurs et de fautes d impression High-Performance Bolt Heaters