PUMP / CONTROL PANEL SWITCHES TECHNICAL BROCHURE BCPFS R10

Similar documents
TECHNICAL BROCHURE BCALARM R4. Indoor and Outdoor Panels and Accessories

QUICK SHIP Products. Available for Same/Next Day Shipment at NO ADDITIONAL CHARGE!

Liquid Level Alarms & Controls

PRODUCT PRICE BOOK January 1, 2019

PRODUCT PRICE BOOK September 4, 2018

PRODUCT PRICE BOOK JUNE 4, 2018

product brochure Sump, Effluent and Sewage Controls

THE MOST COMPLETE LINE OF SYSTEM ALARMS FLOAT SWITCHES ON-SITE ACCESSORIES CONTROL PANELS 24 HOUR SHIPPING ON ALL CATALOG ORDERS!

Alarm Systems Alarm Bot CS2004E CS CS CS H2Oil Alarm System...12

2 SJE-Rhombus...The Name You Trust Above: Simplex - Below: Duplex Above: Simplex - Below: Duplex

GRUNDFOS SEWAGE & EFFLUENT PUMP ACCESSORIES

TEMPERATURE & PRESSURE CONTROLS

Elevator Sump Kits and Components

Elevator Sump Kits and Components

Piggyback Mechanical Float Switch. Piggyback Vertical Mechanical Float Switch. Piggyback Diaphragm Switch. Accessories

STATION MODEL: KPCG21-24x48 PUMP MODEL: KEEN KPCG21 VOLTAGE: 230 PHASE: 1 TANK DIMENSIONS: 24 DIAMETER X 48 DEEP

Thermostats type KPU REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Pressure switch KPU. Data sheet

PRODUCT PRICE BOOK Pricing Effective February 4, We ve Got Panels Under Control.

SIMPLEX WEATHERPROOF CONTROL PANELS

For Technical Service Telephone Facsimile

Commercial Refrigeration Catalog

Overload relays. General descriptions. Configuration of the front

TC-5231 Series, TC-5232, & TC-5241 Series

TECHNICAL BROCHURE BCPSDWWP R2 SIMPLEX/DUPLEX WASTEWATER DISCONNECT STYLE PANELS

Product Data. 49FH, 49FP, 49BF, 49WS, 49BG Humidifiers

Thermostat Catalog 2004

CR Series Command Relays

Installation Guide for models:

Thermostat KPU. Data sheet

3NT SERIES FIXED TEMPERATURE THERMOSTATS Introduction

Afci TR Duplex 20A 125V La. Features amperage rating 20. Dimensions and Weight Width 3.3. Long Description

ADJUSTABLE CONTROLS WHO WE SERVE

Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s)

Introduction to Level Switch Solutions

Technical Instructions Document No P25 ET September 28, ET 141 Electric Surface Mounted Thermostat.

The T6140A,B Remote Bulb Temperature Controller

INSTALLATION INSTRUCTIONS FOR 9330F4552 FREE DELIVERY PLENUM KITS

Introduction to Flow Switch

Three Phase Simplex. Installation (937) Installation Instructions and Operation/Troubleshooting Manual. Installation of Floats.

VIKING RANGE CORPORATION, P.O. DRAWER 956, GREENWOOD,MS USA

PS6 SERIES. Installation PS6 SERIES. Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option

59T, 66T Series Electric Water Heater Controls

Afci TR Duplex 20A 125V Iv. Features amperage rating. Dimensions and Weight. Descriptions

Barnes Oil Sensor Switch

RDM LOCK G Series Electromagnetic Lock. Listings. Standard Features. Ordering Information:

59T, 66T Series Electric Water Heater Controls

MODELS HUM HUMIDIFIERS. Form No. PDS HUM.56.1 HUMBBLFP1025-A-- HUMBBSFP1016-A-- HUMBBLBP2018-A-- HUMBBWTR2019-A-- HUMBBSBP2017-A--

Pump-Up Controller MODEL 4062

Installation Guide for models:

INSTALLATION INSTRUCTIONS FOR 8330*633* COOL ONLY A/C 8330*635* HEAT READY A/C 8530*63** HEAT PUMP CHILLGRILLE FLUSH MOUNT CEILING ASSEMBLY

INSTALLATION INSTRUCTIONS FOR MOUNTING KIT

POWER TRANSFERS ACCESSORIES EAC. Manufacturer Product Product No. Product Description Item No.

Life insurance for your electronics

Pump-Down Controller MODEL 4052

PO Box 827 Hawley, MN (218) Fax (218)

A11 Series Low Temperature Cutout Controls

CR1 Series Triton Corrosion Resistant Washdown Heaters

Page. 1-2 Sepra-Lite Integral Optic Level Switches. 3-5 Electro Optic Level Systems: Probe and Controller

Electric Submersible Pumps

VENTURI NOZZLE SYSYTEM Specification Sheets ALL STAINLESS STEEL COMPRESSED AIR NOZZLE HUMIDIFIERS. With ON/OFF or Proportional Controls

INSTALLATION INSTRUCTIONS FOR 8330*5511 MOUNTING KIT

HUMIDISTATS and Electronic humidity controls

We ve Got Panels Under Control.

CM800 Emergency Call System

Brasch Hazardous Location Unit Heaters

Switch-Pro. AU13 & AZ13 Series Owner s Manual. w/ Compact Relay Controller

CHECK NEW PRODUCTS SECTION FOR NEW INNOVATIVE SOLUTIONS

Centro-Matic Automated Lubrication Systems System Controls

Powers Controls ET 134 Low Temperature Detection Thermostat

Models Series Series

Product Data. HUM Humidifiers

Multi-Output Access Control Power Supply Charger VDC or 24VDC VDC or 3 24VDC.

Series. Access Power Controllers. Installation Guide

INSTALLATION INSTRUCTIONS FOR 7370A736 FLUSH MOUNT CEILING PLENUM

Powers TM Controls ET 134 Line Voltage Room Thermostats

Schneider Electric Erie T155 Series

Modus Model DA General Eastern Low Differential Pressure Alarm Controller

2018 PRICING. alderonind.com STANDARD PRODUCTS

Technical Manual. VFD / Cabinet Heater Upgrade 110 VAC Heater to 12 VDC Heater. Provided by: Chart Inc.

INSTALLATION INSTRUCTIONS FOR 6797A737 HEAT PUMP FLUSH MOUNT CEILING PLENUM

Quick Reference Guide Barrier Strips

System 350 S350A Temperature, S351A Humidity, and S352A Pressure Stage Modules

Description. Construction

36T. Bimetal Disc Controls & Limits. Introduction

631RF Amp Power Supply

Thermo Scientific Air Cadet

temperature Controllers

Type STAR Radiant Heater For Portable Installations

cutting systems We Bring Intelligence to the Table.TM Victor Thermal Dynamics introduces

Installation Guide for AL400ULM. Multi-Output Access Control Power Supply Charger

MICRO SWITCH Basic Switches Line Guide

Pushbutton Switches. Nylon. Specifications. Heavy Duty, Metal Plunger. Specifications S13 S12

KUH. Horizontal Unit Heater. Applications. Description

Entry Level Assessment Blueprint Electrical Construction Technology

FLOAT LEVEL SWITCHES Vertical and horizontal models For OEM applications

Flexible Heaters W A T L O W. Temperature Sensors and Controllers SERIES EHG

FLOOD KING 120V. 2. Keep all filters clean. Do not operate the machine if the filters are clogged.

Electric Coils. Blower Coils. Product Information

Easy Dose Chemical Injection and Dispensing System DEMA Engineering Company

Transcription:

PUMP / CONTROL PANEL SWITCHES TECHNICAL BROCHURE BCPFS R10

TERMS TO KNOW Pump Switches are used to directly control the operation of a pump. They are normally wide-angle switches which means they operate over a range of approximately 70º to 90º. Pump switches are available with piggyback plugs and with bare leads. Some can also be used with control panels. Control Switches are designed to only control pumps when used with a control or alarm panel. They cannot handle the high starting amps and running amperage of a pump, only signal or control amperage. NO or Normally Open is a switch with contacts that are open in the hanging position. They are used to pump down or empty a tank. NC or Normally Closed is a switch with contacts that are closed in the hanging position. They are used to pump up or fill a tank. A2T SERIES SJE Double Float Master Pump Switch Mechanically activated, wide-angle switch designed to control pumps up to FLA, 90 LRA, 1 VAC or 240 VAC. This switch consists of two mechanical floats and a splice tube. The splice tube contains a holding relay which eliminates pump chatter in turbulent conditions. Includes standard mounting clamps and boxed packaging. Cable attached to float housing: flexible 18 gauge, 2 conductor (UL, CSA) SJOW, water-resistant (CPE). Cable above splice: flexible 14 gauge, 3 conductor (UL, CSA) SJTW, water-resistant, thermoplastic. Floats: 2.74" diameter x 4.83" long (7.0 x 12.3 cm) high impact, corrosion resistant, PP housing for use in sewage and non-potable water up to 140º F (60º C). Not sensitive to rotation or turbulence. Pumping range: 3" to 48" Available for pump up or pump down applications. For confined applications requiring an accurate pumping range. See chart for data and order numbers. A2 SERIES MilliAmpMaster Mechanical Float Switch Mechanically activated, snap-action, sealed gold cross-point contacts are designed to activate low current control panels and alarms. Narrow angle Control for Low Voltage AC or DC applications. Electrical Load low current non-arcing applications 125 VAC Max. Load.1 amps (Min. Load.16 milliamps) 30 VDC Max. Load.1 amps (Min. Load.16 milliamps) 5 VDC - Minimum Load 1 milliamp UL Listed for use in non-potable water and sewage. Mounting clamp for attaching to discharge pipe is standard. Not sensitive to rotation. Maximum submergence or water depth, 30' (9 meters), 13 psi. Flexible 18 gauge, 2 conductor SJOW water resistant cable. Impact and corrosion resistant, polypropylene float housing for use in sewage and water up to 140 º F. Float comes with blue cap for easy identification. PAGE 2

A2D SERIES SJE PumpMaster Pump Switch A2HT SERIES High Temperature Float Switch Mechanically activated, heavy duty contacts, wide angle operation. Controls pumps up to 1/2 HP at 1 VAC and 1 HP at 230 VAC. Non-corrosive PVC housing for use in liquids up to 140º F (60º C). Not sensitive to rotation or turbulence. Pumping range: 7" to 36". 16 AWG, SJOW cord is available with or without piggyback plug. Available as pump up, pump down and SPDT models, see Nomenclature Chart. For non-potable water, water or sewage applications. UL Recognized for use in water and sewage.. See chart for amperage range and other data. A2E SERIES SJE PumpMaster Plus Pump Switch Controls pumps up to 3 4 HP at 1 VAC and 2 HP at 230 VAC. 14 AWG, SJOW cord is available with or without piggyback plug. All other features are the same as A2D PumpMaster Series above. Temperature Rating: 221º F (105º C) Wide Angle Switch: contacts open @ 45º below horizontal and close at 45º above horizontal Float Material: PC/ABS (Polycarbonate ABS) Cord Material: Teflon coating Ratings: 13 Maximum Amps, ½ HP, 1/230 V Float Dimensions: 4.63" Long x 2.63" Diameter Nomenclature: see page 9 Available lengths: ', 30' and 50' * NOTE: A2HTL High Temperature Rating: 185º F * No other lengths available in this Series. A2G SERIES SJE AmpMaster Pump Switch Mechanically activated, heavy duty contacts, wide angle operation. Controls pumps up to 1 1 2 HP at 1 VAC and 3 HP at 250 VAC. Non-corrosive PVC housing for use in liquids up to 140º F (60º C). Maximum pump running current of amps. Not sensitive to rotation or turbulence. Pumping range: 9" to 24". 12 AWG, SJOW cord is available only with bare leads. Available for pump down applications only. UL Recognized for use in nonpotable water and sewage. See chart for amperage range and other data. PAGE 3

A2R SERIES SJE MicroMaster Mechanically activated, snap action contacts, wide angle. Pump down operation (optional pump up available) UL Recognized for use in non-potable water and sewage. See chart for amperage range and other data. Controls pump up to 70 amps at 1 VAC and 10 amps at 230 VAC 16 AWG, SJOW cord on 230 V; 18 AWG, SJOW cord on 1 V Pumping range: 8" to 36" Not sensitive to rotation or turbulence A2H SERIES SJE VerticalMaster Pump Switch Mechanically activated vertical operation. Controls pumps up to ½ HP at 1 VAC and 1 HP at 230 VAC. Non-corrosive PVC housing for use in liquids up to 125º F (52º C). Overall Dimensions: 12" High, 5" Deep, 3" Wide. Not sensitive to rotation. Pumping range:.75" to 6.5". 16 AWG, SJOW cord is available with or without piggyback plug. Available for pump down applications only. For confined applications requiring an accurate pumping range. Stainless steel mounting bracket and hose clamp. UL Recognized for use in non-potable water and sewage. See chart for amperage range and other data. A2N SERIES SJE SignalMaster Control Switch Mechanically activated, narrow angle, designed to activate pump control panels or alarms. Not designed for direct connection to pump. Non-corrosive PVC housing for use in liquids up to 140º F (60º C). Not sensitive to rotation. Control differential: 1.5" above or below horizontal. Available as NO (pump down), NC (pump up) or SPDT model, see Nomenclature page. For non-potable water, water or sewage applications. Supplied with a pipe clamp for mounting to pipe. UL Listed for use in non-potable water and sewage.. See chart for amperage range and other data. Normally open - comes with yellow cap for easy identification. Normally closed - comes with white cap for easy identification. Single pole double throw - comes with green cap for easy identification. A2WT SJ ELECTRO WEIGHT Adjustable snap in design. Works with all float switches shown. PVC A2WTC CONERY WEIGHT Zinc plated cord weight Works with all float switches U L PAGE 4

PUMP SWITCHES (WIDE ANGLE) can be connected directly to a pump CONTROL SWITCHES (NARROW ANGLE) can only be used with control panels or alarm panels Order Number Maximum Running Amps Maximum Starting Amps Cord Length (Feet) Bare Leads Pump Switch Control Switch (1) (2) Mounting N.0. N.C. Strap Weight A2D13-10 A2D14 - A2D23U - A2D23W - A2D33 - A2D33U - 13 A2D33W - A2D34 - A2D34W - A2D53W 30 - A2D63W 50 - A2D83W 85 100 - A2E03 4 - A2E23 - A2E23U - A2E33 - A2E53-30 A2E53U - A2E63-50 A2E63U - A2E73 75 - A2E83-100 A2E83U - A2G23 - A2G33 - A2G43 1 25 - A2G53 30 - A2G63 50 - A2H33 12 60 - A2HTL13 10 A2HTL33 A2HTL53 30 A2HT13 13 58 10 A2HT33 A2HT53 30 A2HT63 50 A2N03 3 - A2N13 10 - A2N23 - A2N23W - A2N23WB - A2N23WU - A2N33 - A2N33U - A2N33W - A2N33WB - A2N33WU - A2N34-5 N/A A2N43W - 25 A2N43WU - A2N53 - A2N53W 30 - A2N53WU - A2N63-50 A2N63W - A2N73-75 A2N73W - A2N83-100 A2N83U - A2N93 125 - A2T33 90 - A3 7 - A213-10 A213U - A223 - A223U - A233 See Description N/A - A233U - A233W - A253 - A253U 30 - A263W - N.O. (1) = PUMP DOWN N.C. (2) = PUMP UP PAGE 5

WIDE ANGLE 1 VOLT PIGGYBACK FLOAT SWITCHES TO DIRECTLY CONTROL PUMPS Order Number Maximum Amps Start Amps 1 V Plug A2D11 Cord Length (Feet) A2D11B 10 (1) (2) Mounting N.0. N.C. Strap A2D11C A2D31 A2D31B 13 A2D31C A2D31U A2D51 85 30 A2D51C A2D61 50 A2E21 A2E31 A2E31C A2E31U A2E51 30 A2E61 50 A2H11 A2H11B 10 A2H11C 60 A2H21 A2H31 A2HTL11 13 10 A2HTL31 A2HTL51 30 A2HT11 10 A2HT31 A2HT51 30 A2J11 10 A2J21 A2J31 A2R11 10 60 10 A2R11B A2R31 A2R31B A2T21 A2T31 90 A2T51 30 N.O. (1) = PUMP DOWN N.C. (2) = PUMP UP PAGE 6

WIDE ANGLE 230 VOLT PIGGYBACK FLOAT SWITCHES TO DIRECTLY CONTROL PUMPS Order Number Maximum Amps Start Amps 230 V Plug A2D12 Cord Length (Feet) A2D12B 10 (1) (2) Mounting N.0. N.C. Strap A2D12C A2D32 A2D32B 13 A2D32C A2D32U A2D52 85 30 A2D52C A2D62 50 A2E22 A2E32 A2E32C A2E32U A2E52 30 A2E62 50 A2H12 A2H12B 10 A2H12C 60 A2H22 A2H32 A2HTL12 13 10 A2HTL32 A2HTL52 30 A2HT12 10 A2HT32 A2HT52 30 A2J12 10 A2J22 A2J32 A2R12 10 60 10 A2R12B A2R32 A2R32B A2T22 A2T32 90 A2T52 30 N.O. (1) = PUMP DOWN N.C. (2) = PUMP UP PAGE 7

NOMENCLATURE A2 HTL 3 3 OPTIONS OPTIONS U = Pump Up or Normally Closed (NC) W = A2WT Cable Weight B = Bulk Packed (internal only) Style of Cord 1 = 1 V piggyback 3 = Bare lead 2 = 230 V piggyback 4 = Single pole double throw (SPDT) Length of Cord 1 = 10' 6 = 50' 2 = ' ➀ 7 = 75' 3 = ' 8 = 100' 4 = 25' ➀ 9 = 125' 5 = 30' Only available on select control switches. Type of Switch D = PumpMaster SJE P = MicroMaster Plus SJE ➁ E = PumpMaster Plus SJE R = MicroMaster SJE ➁ G = AmpMaster SJE T = Double Float Master SJE H = VerticalMaster SJE = MilliAmpMaster J = VerticalMaster II SJE ➁ HT = High Temperature MDI - 221º N = SignalMaster SJE HTL = High Temperature MDI - 185º Float Switch ylem Inc. 2881 East Bayard Street Ext., Suite A Seneca Falls, NY 13148 Phone: (866) 325-4210 Fax: (888) 322-5877 www.centripro.com is a trademark of ylem Inc. or one of its subsidiaries. Junior Super Single, Super Single, PumpMaster, PumpMaster Plus, AmpMaster, MilliAmpMaster, VerticalMaster, VerticalMaster II, Sensor Float, Sensor Float Mini, SignalMaster, MicroMaster, and MicroMaster Plus are registered trademarks and tradenames of SJ Electro Systems, Inc. Double Float Master is a registered trademark of SJE-Rhombus Controls. ylem Inc. BCPFS R10 June